PD-9506GC - 6-Port 60W BT PoE Midspan | Microchip Technology
料号: PD-9506GC ⚠ 最后一次采购| 数量 | 单价 | 小计 |
|---|---|---|
| 1 | $695 | $695.00 |
| 10 | $660.25 | $6,602.50 |
| 25 | $625.5 | $15,637.50 |
| 50 | $590.75 | $29,537.50 |
| 100 | $556 | $55,600.00 |
PD-9506GC 概述
A PoE midspan is a network appliance that sits between a non-PoE Ethernet switch and PoE-powered end terminals, injecting DC power onto the spare or data pairs of standard TIA/EIA-568 cabling without requiring replacement of the existing switch. Within the broader power-management taxonomy, the PD-9506GC belongs to the Power Sourcing Equipment (PSE) category of midspans, which itself sits above simple PoE splitters and below full PoE-enabled switches in Ethernet-power deployment hierarchies.
Key features include support for all four 802.3bt power classes (up to Class 8, 71 W minimum at PD), 55 V output voltage at the load, Gigabit data-rate transparency, and built-in Network Management System (NMS) capability. The unit performs full 2-event and 4-event physical-layer classification, ensuring backward compatibility with legacy 802.3af (15.4 W) and 802.3at (30 W) PDs while enabling new high-power installations.
Architecturally, the PD-9506GC uses an internal high-efficiency AC/DC power supply coupled with per-port detection, classification, and current-limiting circuitry. The chassis implements over-current, over-voltage, and thermal protection, and LED indicators provide visual port status and fault diagnostics. All six ports feed power over both the spare pairs and the data pairs (mode A + mode B), ensuring interoperability with the widest range of PD implementations.
Typical applications include ceiling-mounted Wi-Fi 6E/7 access points in enterprise offices, pan-tilt-zoom surveillance cameras in logistics and parking facilities, IP intercoms and access-control readers at building entrances, and digital signage kiosks. The 60 W per-port headroom also supports emerging USB-C-over-Ethernet thin clients and small-form-factor PCs powered solely through structured cabling.
When integrating the PD-9506GC, place the unit in a ventilated 19-inch rack or shelf-mount location because the power supply dissipates up to ~480 W at full 60 W x 6 load. Use only Cat5e or higher cabling, and budget an additional ~0.5 A per port for inrush spikes during PD classification. Microchip recommends pairing with their PD-9606GC for new deployments as the product replacement path.
This page synthesizes distributor pricing tiers, verified drop-in alternatives from the same PD-95xxGC family, side-by-side comparisons, and practical design notes that are not found in the manufacturer datasheet alone.
直接替换替代料: PD-9506GC ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: PD-9506GC (相同外形与封装尺寸) ——差异在于 Compliance, Mounting, Network Management, Output Voltage, PoE Standard.
快速对比工具——选择替代料号进行并排对比:
PD-9606GC/AC-US
✅ 直接替换✓ 有现货
$665.3 / 个
查看数据手册 →PD-9512GC
✅ 直接替换📋 参考替代料(不在目录中)
PD-9524GC
✅ 直接替换📋 参考替代料(不在目录中)
PD-9506GC/AC-US
✅ 直接替换📋 参考替代料(不在目录中)
PD-9506GC/AC-UK
✅ 直接替换📋 参考替代料(不在目录中)
PD-9506-10GC
✅ 直接替换📋 参考替代料(不在目录中)
PD-9506GC 最大额定值与电气特性
| Product Type | PoE Midspan Injector |
| Number of Ports | 6 |
| Output Power per Port | 60 W |
| Total Max Output Power | 360 W |
| 输出电压 | 55 V DC |
| PoE Standard | IEEE 802.3bt Type 3 / Type 4 |
| Backward Compatibility | IEEE 802.3af / 802.3at |
| 数据速率 | 10/100/1000 Mbps |
| Data Pass-through | Yes (transparent) |
| Input Power | 100-240 V AC, 50/60 Hz |
| Network Management | Yes (NMS) |
| 工作温度 | 0 C to 40 C |
| AC Power Cord Options | US / UK / EU / AC variants |
| Mounting | 1U rack / shelf-mount |
| Compliance | IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt |
PD-9506GC standard 引脚配置指南
PD-9506GC(standard 封装)的引脚配置。 该功率器件具有栅极、漏极和源极端子。对于无极性封装,请参阅制造商数据手册以了解确切的引脚 1 方向和封装尺寸细节。常见应用包括电源设计、电机驱动和负载开关。
暂无详细引脚数据: PD-9506GC.
请参阅 数据手册 以查看完整引脚配置。
典型应用
PD-9506GC 适用于 6 应用s: Enterprise Wi-Fi 6/6E Access Point Power, PTZ and Dome Surveillance Cameras, IP Intercoms and Access Control Readers, Digital Signage and Kiosks, Thin Clients and Small-Form-Factor PCs, Conference Room AV-over-IP Endpoints.
Enterprise Wi-Fi 6/6E Access Point Power
The PD-9506GC's 60 W per-port budget delivers the headroom required by tri-radio IEEE 802.11ax Wi-Fi 6 and 6E access points, which draw 35-51 W under full 4x4 MIMO operation. By injecting 55 V DC on each port, the midspan eliminates the need for ceiling-mounted AC outlets, reducing Wi-Fi deployment cost by approximately 30 percent according to industry cabling studies. Each of the six ports powers a separate AP with full mode A + mode B 802.3bt negotiation, ensuring compatibility with Cisco, Aruba, Ruckus, and Juniper Mist APs.
推荐
PTZ and Dome Surveillance Cameras
Pan-tilt-zoom (PTZ) and outdoor dome network cameras are among the highest-power PoE loads in surveillance networks, with heater-equipped outdoor PTZ units drawing 30-60 W for heater, motor, and IR illuminator simultaneously. The PD-9506GC's 60 W per-port budget delivers full power even at -40 C ambient on the camera side, including heater warm-up surge. Cabling infrastructure remains Cat5e or Cat6, eliminating the need for outdoor AC conduit runs to camera poles.
推荐
IP Intercoms and Access Control Readers
Modern IP intercoms and access-control readers with LCD displays, RFID readers, and door-strike actuators require 25-45 W sustained, which exceeds legacy 802.3at limits. The PD-9506GC elevates each port to 802.3bt Type 4 headroom of 60 W, future-proofing the deployment against feature additions such as face-recognition cameras integrated into the reader. Six ports support a small commercial building's full intercom-and-access-control subsystem from one closet-mounted midspan.
推荐
Digital Signage and Kiosks
Interactive digital signage kiosks with touchscreen displays, embedded PCs, and barcode scanners typically draw 35-55 W, which the PD-9506GC handles comfortably on any of its six ports. Running power over a single Cat6 cable eliminates the need for an electrician at each kiosk location, slashing deployment cost in retail and transportation-hub rollouts. The midspan's NMS capability allows remote power-cycling of misbehaving kiosks, reducing field-service truck rolls.
推荐
Thin Clients and Small-Form-Factor PCs
USB-C-over-Ethernet thin clients and compact enterprise PCs drawing 45-60 W via PoE are an emerging application enabled by 802.3bt. The PD-9506GC powers up to six such clients per chassis, supporting a small VDI deployment from a single floor-distribution closet. Where Cat6A infrastructure already exists, the PD-9506-10GC variant delivers 10 Gbps data alongside 60 W power, enabling future migration without PoE replacement.
推荐
Conference Room AV-over-IP Endpoints
AV-over-IP encoders and decoders for conference rooms (Dante, SDVoE, NDI) increasingly draw 30-50 W to drive their HDMI I/O and DSP subsystems. The PD-9506GC provides 60 W per port with full Gigabit data pass-through, eliminating separate power supplies at each endpoint and reducing under-table cable clutter. The midspan's NMS integrates with corporate AV management platforms for unified visibility into the AV estate.
推荐
推荐产品汇总
工程参考数据: PD-9506GC ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | PD-9606GC | PD-9512GC | PD-9524GC | PD-9506-10GC |
|---|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package / Form Factor | 1U 19-inch rack chassis | 1U 19-inch rack chassis | 1U 19-inch rack chassis | 1U 19-inch rack chassis | 1U 19-inch rack chassis |
| Port Count | 6 | 6 | 12 | 24 | 6 |
| Output Power per Port | 60 W | 60 W | 60 W | 60 W | 60 W |
| Total Aggregate PoE Budget | 360 W | 360 W | 720 W | 1440 W | 360 W |
| PoE Standard | IEEE 802.3bt Type 3/4 | IEEE 802.3bt Type 3/4 | IEEE 802.3bt Type 3/4 | IEEE 802.3bt Type 3/4 | IEEE 802.3bt Type 3/4 |
| Data Rate | 10/100/1000 Mbps | 10/100/1000 Mbps | 10/100/1000 Mbps | 10/100/1000 Mbps | 2.5/5/10 Gbps |
| Network Management | Yes (NMS) | Yes (NMS) | Yes (NMS) | Yes (NMS) | Yes (NMS) |
| Lifecycle Status | Last-Time-Buy (2025-05-20) | Active | Last-Time-Buy | Last-Time-Buy | Active |
| AC Input | 100-240 V AC, 50/60 Hz | 100-240 V AC, 50/60 Hz | 100-240 V AC, 50/60 Hz | 100-240 V AC, 50/60 Hz | 100-240 V AC, 50/60 Hz |
关键差异点
- True drop-in successor available from same vendor (对比 PD-9606GC)
- 10 Gigabit data pass-through option (对比 PD-9506-10GC)
- Higher port density variants in same family (对比 PD-9512GC)
设计说明
Estimated: at full 60 W load on all six ports (360 W PoE + 30-50 W conversion losses), the PD-9506GC dissipates approximately 410-440 W of heat through its chassis. In a fully populated 19-inch rack, leave at least 1U of empty rack space above and below the midspan for airflow, and confirm the rack's HVAC can remove this load from a confined closet. For sites running the unit at > 80% port loading continuously, plan for active rack ventilation or an ambient operating temperature derating to 35 C.
Place the PD-9506GC within 100 m cable run of the powered devices; this is the IEEE 802.3bt channel-length limit. For sites exceeding 100 m, install a PoE extender or place the midspan in a wiring-closet closer to the load. Avoid routing PoE cables parallel to fluorescent-light ballast wiring or three-phase power feeders to minimize common-mode noise injection; cross at 90 degrees where crossings are unavoidable.
Do not mix the PD-9506GC output with passive PoE injectors or non-standard 24/48 V splitters on the same cable run - the 55 V PoE voltage can damage PDs expecting 802.3af-class voltage. According to the Microchip datasheet, always verify that the attached PDs are 802.3af/at/bt-compliant before energizing. If the green Link LED does not illuminate within 5 seconds of PD connection, the cable run likely has a pair-to-pair short or excessive DC resistance; replace the run before further troubleshooting.
合规信息