MORNSUN Guangzhou Science & Technology

TDA51S485HC - Isolated RS-485 Transceiver 500kbps | MORNSUN

부품 번호: TDA51S485HC ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
SOIC-16 (300 mil) Package
시작가 $1.42 USD / 개
MOQ: 1 |
가격 업데이트: 2026-09-02
볼륨 가격
수량 단가 합계
1 $1.82 $1.82
10 $1.74 $17.40
100 $1.65 $165.00
500 $1.5 $750.00
1,000 $1.42 $1,420.00
ℹ️ 모든 가격은 USD 기준입니다

TDA51S485HC 개요

The MORNSUN TDA51S485HC is an isolated, half-duplex enhanced RS-485/RS-422 transceiver with integrated signal isolation, fully compliant with the TIA/EIA-485-A standard, supporting data rates up to 500 kbps in a 16-pin SOIC-16 (300 mil) package.

An isolated RS-485 transceiver is a communication interface IC that combines a differential line driver and receiver with galvanic isolation between the logic side and the bus side. Isolation is a critical layer in industrial system hierarchy: within power management and interface electronics, it breaks ground loops, blocks common-mode transients, and protects low-voltage controllers from high-voltage faults on long cable runs in factories and buildings.

Key features of the TDA51S485HC include full TIA/EIA-485-A compliance, half-duplex operation on a single twisted pair, data transmission up to 500 kbps, and an integrated fail-safe circuit. The fail-safe function guarantees a defined receiver output state when the bus is idle, shorted, or open, eliminating false characters caused by undriven bus conditions - a common problem in legacy RS-485 networks that otherwise requires external bias resistors.

The enhanced transceiver architecture integrates the isolation barrier in a compact SOIC-16-300mil body, reducing board area compared to discrete optocoupler-plus-transceiver designs. It is engineered for harsh industrial environments where robust differential signaling, noise immunity, and long-distance communication over twisted-pair cable are required.

Typical applications include industrial automation and PLC networks, building control and HVAC systems, motor control and inverter communication buses, energy metering, and security or access-control systems that communicate over RS-485 fieldbus segments.

A key design consideration is bus termination and biasing: even with the internal fail-safe circuit, verify that your network topology, node count, and cable length remain within RS-485 loading and 500 kbps timing budgets; add 120-ohm termination at both cable ends for long runs.

This page synthesizes distributor pricing, stock data, drop-in alternative information, and practical design notes not found in the manufacturer datasheet alone.

드롭인 대체품: TDA51S485HC — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: TDA51S485HC (동일 폼 팩터 및 풋프린트) — 차이점: Data Rate, Package, RoHS Status, Isolation Voltage, Product Type.

MORNSUN Guangzhou Science & Technology
Data Rate: 150 Mbps
Package: SOIC-16-300mil (wide body)
RoHS Status: Compliant
비교 대상: TDA51S485HC →
MORNSUN Guangzhou Science & Technology
Data Rate: Up to 1 Mbps
Package: SOIC-16-300mil (16-SOIC Module, 0.295 in / 7.50 mm width)
RoHS Status: RoHS compliant
비교 대상: TDA51S485HC →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

TDA51SCANHC

✅ 드롭인 ⚠️ 사양 미검증
MORNSUN Guangzhou Science & Technology
📦 SOIC-16 (300 mil)
Isolated CAN bus transceiver with integrated 5 V isolated power · CANbus (ISO11898-2 compliant) · Up to 1 Mbps · 5000 VDC · 150 kV/us · 4.5 V to 5.5 V · 5 V isolated power · -40C to +125C

✓ 재고 있음

$1.45 / 개

데이터시트 보기 →

TDA51S485HC 사양

Product Type Isolated RS-485/RS-422 Transceiver (with power)
Communication Standard TIA/EIA-485-A compliant
데이터 속도 Up to 500 kbps
Duplex Mode Half-duplex
Fail-Safe Circuit Yes (integrated)
패키지 SOIC-16 (300 mil)
실장 유형 Surface Mount
Isolation Type Galvanic isolation (integrated)
Number of Transceivers 1
Protocol Support RS-485, RS-422
RoHS 상태 RoHS compliant (per distributor listing)
Typical Applications Industrial automation, building control

TDA51S485HC soic-16 (300 mil) 핀 구성 가이드

TDA51S485HC(soic-16 (300 mil) 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.

TDA51S485HC의 soic-16 (300 mil) 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: TDA51S485HC.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

TDA51S485HC 적합 용도: 6 애플리케이션s: Industrial Automation and PLC Networks, Building Control and HVAC Systems, Motor Drives and Inverter Communication, Energy Metering and Smart Grid Nodes, Security and Access Control Systems, Battery Management and Energy Storage Communication.

🏭

Industrial Automation and PLC Networks

The TDA51S485HC fits industrial automation fieldbus segments because its 500 kbps data rate matches common Profibus DP and Modbus RTU speeds, and its TIA/EIA-485-A compliance guarantees interoperability with standard PLC serial ports. The integrated galvanic isolation separates the noisy factory floor bus from sensitive controller logic, breaking ground loops that arise when machines on different power panels share one RS-485 trunk. The fail-safe circuit keeps receiver outputs defined when a node drops offline or the bus is idle, preventing spurious framing errors in polling-based protocols. Deployed between the MCU UART and the twisted-pair trunk with 120-ohm end-of-line termination, it delivers robust multi-drop communication across long cable runs typical of plant-floor installations.

🧩

Building Control and HVAC Systems

Building management systems frequently use RS-485 (BACnet MS/TP, Modbus RTU) to link thermostats, dampers, energy meters, and air-handling units across multiple floors. The TDA51S485HC suits this environment because half-duplex 500 kbps operation matches MS/TP and Modbus timing budgets, while the integrated isolation protects controllers from ground-potential differences between riser cable segments and locally powered equipment. Its fail-safe circuit eliminates the external bias resistors that would otherwise be required at the ends of unterminated or lightly loaded trunk lines, simplifying commissioning of large daisy chains. The SOIC-16 footprint allows compact integration into thermostat and controller boards where panel space is limited and long-distance differential signaling reliability is essential.

⚡

Motor Drives and Inverter Communication

Variable-frequency drives and servo inverters generate large common-mode transients and high dv/dt switching noise that readily destroy non-isolated RS-485 ports. The TDA51S485HC addresses this with its integrated isolation barrier and differential bus signaling compliant with TIA/EIA-485-A, transmitting commands and status at up to 500 kbps between the drive controller and higher-level automation networks. Placed between the drive MCU UART and the fieldbus terminals, it galvanically separates the control electronics ground from the motor-side power stage ground, preventing ground-loop currents from corrupting data or damaging ports. Its industrial-grade construction and fail-safe receiver make it appropriate for the electrically harsh environment surrounding PWM power electronics.

🔌

Energy Metering and Smart Grid Nodes

Electricity meters, RTUs, and distribution monitoring nodes commonly report over RS-485 trunks running Modbus RTU at 9.6 to 115.2 kbps, comfortably within the TDA51S485HC's 500 kbps capability. The isolation barrier is essential here: metering electronics sit near mains potential, and the isolated transceiver keeps the fieldbus side galvanically separate from the measurement front end, protecting both data integrity and downstream equipment. The fail-safe function is valuable on multi-drop meter buses where meters are periodically powered down for maintenance, keeping the receiver output stable instead of generating error frames. Its SOIC-16 package suits the compact, cost-sensitive PCBs typical of polyphase meter designs, while differential signaling ensures reliable communication over long meter-to-concentrator cable runs.

🎥

Security and Access Control Systems

Access-control panels, card readers, and CCTV controllers frequently network over RS-485 runs spanning buildings, where cable crossings with power lines introduce common-mode noise. The TDA51S485HC provides the required isolation between distributed reader electronics and the central controller, and its 500 kbps rate covers typical Wiegand-over-RS-485 and proprietary security bus protocols. The fail-safe circuit ensures that a disconnected or powered-off reader does not inject random bytes into the shared bus, which could trigger false alarm events. Half-duplex operation matches the polling/response traffic pattern used by most security controllers, and the SOIC-16 footprint integrates neatly into reader and door-controller boards built for long-distance differential communication.

🔋

Battery Management and Energy Storage Communication

Battery management systems in energy storage racks often daisy-chain over isolated RS-485 links connecting stack monitors to the master controller, since the bus must cross large voltage domains between series-connected battery modules. The TDA51S485HC's integrated isolation allows each module's BMS electronics to communicate at up to 500 kbps without sharing ground references with adjacent modules or the master, preventing circulating currents through the communication cable. The fail-safe receiver keeps the bus state defined during module power-up sequences, when nodes join the trunk asynchronously. Its industrial qualification philosophy and robust differential interface make it suitable for the electrically noisy environment created by switching converters and contactor switching in storage systems.

What is the TDA51S485HC and what does it do?
The TDA51S485HC is an isolated half-duplex enhanced RS-485/RS-422 transceiver from MORNSUN, designed for RS-485 data bus networks. According to the MORNSUN datasheet, it is fully compliant with the TIA/EIA-485-A standard and supports data transmission of up to 500 kbps. It integrates a fail-safe circuit and comes in a SOIC-16 (300 mil) package, making it suitable for industrial communication over long twisted-pair cable runs in noisy environments.
What is the maximum data rate of the TDA51S485HC?
The TDA51S485HC supports data transmission of up to 500 kbps. According to the MORNSUN datasheet, the device is designed for RS-485 data bus networks and is fully compliant with TIA/EIA-485-A. This data rate matches the classic Profibus DP speed and is well suited for industrial fieldbus applications where moderate speed, long cable length, and high noise immunity are more important than bandwidth.
What is the price of TDA51S485HC?
As of 2026-09-03, the TDA51S485HC is priced from approximately $1.8158 per unit at LCSC, and from about $1.4206 at Weyland. JLCPCB also lists the part with volume pricing tiers. Prices vary with quantity and distributor; typical volume pricing at 1000 pieces falls in the $1.40 to $1.80 range. Always confirm current pricing at your distributor, as isolated transceiver pricing can fluctuate with stock levels.
Where can I buy TDA51S485HC online and is it in stock?
The TDA51S485HC can be purchased online from LCSC (listed as C49242252, with in stock as of the last verified date), JLCPCB, Weyland, Avaq, Wolfchip, and JAK Electronics. icDirectory reported in stock as of February 2025. Availability is strong across multiple distributors, so lead times are generally short; confirm current stock before ordering for production quantities.
What is the difference between TDA51S485HC and TDA51SCANHC?
Both parts belong to MORNSUN's isolated transceiver family and share the isolated, fail-safe design approach, but they target different bus types. The TDA51S485HC is an isolated RS-485/RS-422 transceiver for differential fieldbus networks, whereas the TDA51SCANHC is oriented toward isolated CAN bus communication. They are not pin-for-pin interchangeable because CAN and RS-485 transceivers have different bus signaling requirements; select the part matching your physical bus standard.
Can TDA51S485HC replace ADM2483 or ADM2582E from Analog Devices?
The TDA51S485HC can functionally replace isolated RS-485 transceivers such as the ADM2483/ADM2582E in new designs, but it is not a verified pin-to-pin drop-in replacement per the cross-reference data available here. No authoritative cross-reference listing was found for these parts. Before substitution, compare supply voltage, isolation rating, data rate (500 kbps), package footprint (SOIC-16-300mil), and pinout, and expect possible PCB layout changes.
When should I choose the TDA51S485HC over a non-isolated RS-485 transceiver?
Choose the TDA51S485HC whenever the RS-485 bus connects equipment with separate ground references, long cable runs, or exposure to surge and common-mode transients - for example factory automation, building HVAC control, or inverter communication. The integrated isolation breaks ground loops and protects the controller side, whereas non-isolated transceivers require external optocouplers and isolated supplies to achieve the same protection, increasing board area and BOM complexity.
What is the best drop-in replacement for TDA51S485HC?
Within the MORNSUN same-family catalog, the closest candidate is the TDA51SCANHC, but note it serves isolated CAN rather than RS-485 signaling, so it is not a true drop-in for RS-485 networks. The cross-reference search performed on 2026-09-03 found no verified pin-to-pin drop-in replacement from another manufacturer. Designers needing a substitute should perform a parametric comparison of isolated RS-485 transceivers in SOIC-16 packages and verify the pinout against the MORNSUN datasheet.
Where can I download the TDA51S485HC datasheet PDF?
The official TDA51S485HC datasheet PDF is available directly from the manufacturer at https://www.mornsun-power.com/public/uploads/pdf/TDA51S485HC.pdf. Distributor pages at LCSC, JLCPCB, and JAK Electronics also link to the same document. The datasheet describes the device as a half-duplex enhanced transceiver for RS-485 data bus networks, TIA/EIA-485-A compliant, with data rates up to 500 kbps. Always download datasheets from the manufacturer or authorized distributors to avoid outdated revisions.
Where can I find the TDA51S485HC pinout?
The TDA51S485HC pinout is documented in the official MORNSUN datasheet PDF available at mornsun-power.com. The device is packaged in a 16-pin SOIC (300 mil wide body). Because the full pin assignment was not included in the verified data used to build this page, we do not reproduce pin numbers here; consult the datasheet directly for the complete VCC, GND, TXD, RXD, DE/RE, A/B bus pin mapping before laying out your PCB.
Is the TDA51S485HC suitable for industrial automation applications?
Yes, the TDA51S485HC is specifically designed for industrial use. According to icDirectory, it is a highly integrated, compact industrial-grade isolated RS-485 transceiver suitable for industrial automation and building control systems requiring robust data transmission over long distances. Its TIA/EIA-485-A compliance, 500 kbps data rate, integrated fail-safe circuit, and galvanic isolation make it well matched to PLC networks, motor drives, energy metering, and harsh-environment fieldbus segments.
Does the TDA51S485HC have a fail-safe function and why does it matter?
Yes, the TDA51S485HC integrates a fail-safe circuit, as stated in both the LCSC product listing and the MORNSUN datasheet. The fail-safe feature forces the receiver output to a defined logic state when the bus is idle, open, or shorted. Without fail-safe biasing, an undriven RS-485 bus can cause receivers to toggle randomly and generate framing errors. The integrated fail-safe eliminates the need for external pull-up/pull-down bias resistors on the A and B lines.
What are the key specifications of the TDA51S485HC engineers should know?
The TDA51S485HC is a MORNSUN isolated, half-duplex enhanced RS-485/422 transceiver, TIA/EIA-485-A compliant, supporting data rates up to 500 kbps, with an integrated fail-safe circuit, in a SOIC-16 (300 mil) surface-mount package. It includes integrated galvanic isolation for ground-loop rejection and transient protection. RoHS compliance is listed by distributors. Detailed supply voltage, isolation voltage, and temperature range values should be taken from the official MORNSUN datasheet for final designs.
Is TDA51S485HC RoHS compliant?
Yes, the TDA51S485HC is listed as RoHS compliant. Both the LCSC product page and the JLCPCB part detail page describe the part as ROHS-compliant for this SOIC-16 isolated RS-485/422 transceiver. For REACH, halogen-free status, and other environmental declarations, consult the manufacturer's official compliance documentation, as those specific certifications were not stated in the verified distributor data.
What design considerations apply when using the TDA51S485HC?
Key considerations are bus termination, supply decoupling, and isolation-barrier PCB design. Add 120-ohm termination at both ends of long cable runs; the integrated fail-safe removes the need for external bias resistors on idle buses. Decouple both logic-side and bus-side supplies with local ceramic capacitors. Maintain adequate creepage and clearance across the isolation barrier on the PCB per your system's isolation requirements. Confirm supply voltage and isolation ratings from the MORNSUN datasheet, as those values are not reproduced in the data behind this page.

엔지니어링 참조 데이터: TDA51S485HC — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the TDA51S485HC when you need an isolated, half-duplex RS-485/422 interface that is TIA/EIA-485-A compliant, runs up to 500 kbps, and includes an integrated fail-safe circuit in a compact SOIC-16 package - the classic profile for Modbus RTU, BACnet MS/TP, and Profibus-class fieldbus nodes in industrial automation, building control, metering, and drive communication. Its strong multi-distributor stock (14,500+ units at LCSC as of the last verified date) makes it a low-sourcing-risk choice. Choose the same-family TDA51SCANHC instead when your physical layer is CAN rather than RS-485. If you need a different manufacturer's solution, no verified pin-to-pin drop-in was found; evaluate isolated RS-485 transceivers from TI or Analog Devices as functional (not footprint-compatible) alternatives and verify pinout, supply voltage, and isolation ratings against your PCB before committing.

대체품과의 비교

파라미터 이 제품 TDA51SCANHC
Package SOIC-16 (300 mil) SOIC-16 (300 mil) - same footprint family
Brand MORNSUN MORNSUN
Bus Standard RS-485 / RS-422 (TIA/EIA-485-A) CAN bus
Duplex Mode Half-duplex Half-duplex (CAN)
Fail-Safe Circuit Yes (integrated) Yes (per family datasheet)
Isolation Integrated galvanic isolation Integrated galvanic isolation

주요 차별점

  • Integrated fail-safe circuit eliminates external bias resistors (vs TDA51SCANHC)
  • Single-package isolation solution (vs Non-isolated transceiver + optocoupler discrete solution)
  • Standard-compliant 500 kbps fieldbus operation (vs TDA51SCANHC (CAN-family))

설계 노트

For long RS-485 runs with the TDA51S485HC, terminate the bus with 120-ohm resistors at both physical ends of the twisted pair. Although the integrated fail-safe circuit removes the need for external A/B bias resistors on idle buses, termination is still required at 500 kbps to suppress reflections on cables longer than roughly a few meters. Keep the stub length from each node's transceiver to the trunk as short as possible (ideally under 0.3 m) to minimize reflections.

Layout the TDA51S485HC so that the logic-side and bus-side circuits remain on opposite sides of the isolation barrier, preserving the device's creepage and clearance performance on the PCB. Decouple both supply domains with 100 nF ceramic capacitors placed within a few millimeters of the respective supply pins. Do not route logic signals across the barrier region, and keep high-voltage or noisy switching traces away from the A/B bus pins to protect the differential signaling integrity.

Do not assume pin-for-pin interchangeability with other isolated RS-485 transceivers such as ADM2483 or ISO3082-class parts: the cross-reference search found no verified drop-in equivalent for the TDA51S485HC, so any substitution requires a full pinout and footprint check against the MORNSUN datasheet. Also verify the supply voltage and isolation voltage ratings directly from the datasheet before finalizing designs, since these values were not included in the verified distributor data behind this page.

규정 준수 정보

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

RoHS compliance stated on LCSC and JLCPCB product pages. REACH, lead-free, halogen-free, and conflict-minerals statuses were not stated in the verified data.

데이터 검증일: 2026-09-03 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

TDA51S485HC TDA51S485HC datasheet MORNSUN TDA51S485HC isolated RS-485 transceiver 500kbps SOIC-16 TDA51S485HC pinout SOIC-16 TDA51S485HC Modbus RTU industrial automation TDA51S485HC equivalent substitute TDA51S485HC vs ADM2483 TDA51S485HC price buy in stock what is TDA51S485HC max data rate isolated RS-485 transceiver with fail-safe TDA51S485HC drop-in replacement

관련 부품 & 용어

MORNSUN Guangzhou Science & Technology TDA51S485HC TDA51SCANHC isolated RS-485 transceiver RS-485 RS-422 TIA/EIA-485-A half-duplex transceiver fail-safe circuit galvanic isolation digital isolator SOIC-16 (300 mil) surface mount RoHS Modbus RTU BACnet MS/TP industrial automation building control systems Profibus DP fieldbus 500 kbps data rate Interface IC
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기