TJA1042T/3 - 5Mbit/s CAN Transceiver, SOIC-8 | NXP
부품 번호: TJA1042T/3 ✗ 단종TJA1042T/3 개요
A CAN transceiver is an interface IC that converts logic-level signals from a CAN controller into the dominant and recessive voltage states used on a differential CAN bus. It also converts bus levels into receive data for the controller. The TJA1042 belongs to the high-speed CAN transceiver category within the broader network-interface IC and automotive communication hierarchy.
The TJA1042T/3 provides differential transmit and receive capability, a low-power Standby mode, and bus wake-up capability. It can remain passive when unpowered, helping the connected CAN network enter a low-current state. The VIO interface allows direct connection to microcontrollers operating from 3V to 5V, while the main transceiver supply operates from 4.5V to 5.5V.
The TJA1042 implements the CAN physical layer defined by ISO 11898-2:2016 and the SAE J2284-1 through J2284-5 specifications identified in the NXP documentation. These standards establish the electrical behavior expected of high-speed CAN nodes, including bus signaling, termination, timing, and fault behavior.
Typical uses include automotive body and comfort modules, industrial CAN gateways, engine controllers, battery-management systems, and embedded control units that communicate over a two-wire CAN network. Its 5Mbit/s capability makes it appropriate for systems that combine conventional CAN traffic with the faster data phase of CAN FD.
Designers should connect the CANH and CANL pins to the protected bus network, provide the bus-side termination specified by the system architecture, and use a suitable common-mode choke or ESD protection where required. VIO should be connected to the microcontroller interface supply, while VCC must satisfy the 4.5V to 5.5V operating range.
This page combines the manufacturer specifications, package information, interface standards, drop-in candidates, and application guidance needed to evaluate the TJA1042T/3 as a high-speed CAN physical-layer interface for automotive and industrial control systems.
드롭인 대체품: TJA1042T/3 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: TJA1042T/3 (동일 폼 팩터 및 풋프린트) — 차이점: Package, Product Type, Bus Interface, Operating Temperature, CAN Protocol Support.
TJA1051T/3/1J
✅ 드롭인가격 문의
데이터시트 보기 →TCAN1042HD
✅ 드롭인가격 문의
데이터시트 보기 →TCAN1042VDRQ1
✅ 드롭인✗ 재고 없음
$0.33923 / 개
데이터시트 보기 →TJA1042T/3 사양
| Product Type | High-speed CAN transceiver with Standby mode |
| Supported Protocol | CAN and CAN FD fast phase |
| Maximum CAN Data Rate | 5 Mbit/s |
| Main Supply Voltage Range | 4.5V to 5.5V |
| VIO Supply Voltage Range | 3V to 5V |
| Bus Interface | Differential two-wire CAN bus |
| Transmit and Receive Capability | Differential |
| Low-Power Mode | Standby mode with CAN bus wake-up |
| Unpowered Behavior | Passive behavior |
| CAN Physical-Layer Standard | ISO 11898-2:2016 |
| Automotive Interface Standards | SAE J2284-1 through SAE J2284-5 |
| Microcontroller Interface | VIO interface for 3V to 5V microcontrollers |
| 패키지 | 8-pin SOIC, 3.0 mm x 3.0 mm body |
| 실장 유형 | Surface mount |
TJA1042T/3 8-pin soic, 3.0 mm x 3.0 mm body 핀 구성 가이드
TJA1042T/3(8-pin soic, 3.0 mm x 3.0 mm body 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: TJA1042T/3.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
TJA1042T/3 적합 용도: 6 애플리케이션s: Automotive Body Control Modules, Industrial CAN Gateways, Battery Management Systems, Engine and Powertrain Controllers, Embedded CAN Sensor Nodes, Test and Measurement Equipment.
Automotive Body Control Modules
The TJA1042T/3 fits body-control and comfort modules that exchange commands and sensor status over a two-wire CAN network. Its differential CAN interface supports CAN FD fast-phase rates up to 5Mbit/s, while the 4.5V-to-5.5V VCC range and separate 3V-to-5V VIO interface allow connection to controllers operating at different logic levels. The 8-pin SOIC package simplifies placement in compact automotive controller boards. Standby mode and CAN-bus wake-up are useful when the module must reduce current consumption without becoming isolated from the vehicle network. The /3 variant should be selected specifically when the controller interface uses VIO, because related TJA1042 variants may provide SPLIT on pin 5 instead.
추천
Industrial CAN Gateways
The TJA1042T/3 is appropriate for industrial gateways that connect embedded controllers to two-wire CAN equipment. Its documented capability of 5Mbit/s in the CAN FD fast phase supports gateways handling high-volume status and control traffic while remaining compatible with conventional CAN nodes. The separate VIO supply permits direct interfacing with 3V or 5V microcontrollers, reducing level-shifting circuitry when the logic supply already matches. Low-power Standby operation and wake-up through the CAN bus support equipment that normally sleeps but must respond when another node initiates communication. PCB implementation still requires controlled bus routing, appropriate termination, protection appropriate to the installation environment, and validation of common-mode levels.
추천
Battery Management Systems
The TJA1042T/3 can serve as the physical-layer interface between a battery-management controller and a vehicle or industrial CAN network. Differential transmit and receive operation provides noise-resistant communication for pack state, balancing commands, fault information, and system diagnostics. The device supports data rates up to 5Mbit/s in the CAN FD fast phase, which is useful when the controller uses segmented CAN FD frames. Its 3V-to-5V VIO interface can connect to suitable low-voltage controllers while the transceiver's main supply remains within 4.5V to 5.5V. Standby mode and CAN-bus wake-up help a management unit remain responsive while controlling quiescent consumption during inactive periods. The exact electrical and qualification requirements of the battery platform must be verified before production use.
추천
Engine and Powertrain Controllers
The TJA1042T/3 is suitable for CAN-connected engine and powertrain control units requiring a robust physical-layer interface. Differential signaling supports communication over the two-wire CAN network, and operation up to 5Mbit/s accommodates CAN FD fast-phase traffic used for control data. The VIO interface lets the transceiver connect with a 3V-to-5V controller without imposing the controller's lower supply voltage on the main transceiver rail. Low-power Standby mode can reduce activity in appropriate operating states, while bus wake-up helps the controller recognize an addressed network request. Because these systems impose strict EMC, transient, fault-containment, and qualification requirements, engineers should validate the complete module against its automotive specification rather than relying on generic transceiver functionality.
추천
Embedded CAN Sensor Nodes
The TJA1042T/3 can connect a compact sensor or actuator node to a CAN-based monitoring network. The 3V-to-5V VIO interface is useful for low-power microcontrollers, while the main transceiver supply remains independently constrained to 4.5V to 5.5V. At data rates up to 5Mbit/s, the interface can support CAN FD fast-phase messages carrying richer sensor payloads or diagnostic data. Standby mode and CAN-bus wake-up allow remote nodes to reduce consumption and still become active when bus activity occurs. Designers should minimize CANH and CANL trace separation changes, preserve the intended termination topology, and place protection close to the external connector so transient energy does not propagate into the controller.
추천
Test and Measurement Equipment
The TJA1042T/3 can provide a CAN interface for test equipment, diagnostic programmers, and communication analyzers that need to participate in an operating vehicle or industrial CAN network. Differential receive and transmit functions allow the instrument to exchange command, diagnostic, and logging traffic, while operation up to 5Mbit/s supports CAN FD fast-phase analysis. The VIO interface accommodates compatible controller logic levels and the separate main supply helps organize analog and digital power domains. Standby mode is useful in portable instruments that should reduce consumption between test sequences, and CAN-bus wake-up can provide network-directed activation. External protection and isolation requirements depend on the distance, environment, and ground-potential difference of the equipment under test.
추천
추천 제품 요약
엔지니어링 참조 데이터: TJA1042T/3 — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | TJA1051T/3/1J | TCAN1042H | TCAN1042 |
|---|---|---|---|---|
| Manufacturer | NXP Semiconductors | NXP Semiconductors | Texas Instruments | Texas Instruments |
| Package | SOIC-8 | SOIC-8 | SOIC-8 | SOIC-8 |
주요 차별점
- Supports 3V-to-5V microcontroller interfacing through VIO (vs TJA1042T)
- Documented low-power network behavior (vs TCAN1042H)
- Lower reported undervoltage threshold (vs TCAN1042H)
- 5Mbit/s CAN FD fast-phase operation with NXP low-power features (vs TJA1051T/3/1J)
설계 노트
Route CANH and CANL as a tightly coupled differential pair with continuous reference to a common ground plane, avoiding plane splits, test pads, and unnecessary stubs. Keep the transceiver close to the protection components and external connector to minimize trace area exposed to radiated and conducted disturbances. Follow the NXP package drawing and pin-description table when assigning the 8-pin SOIC nets, and do not substitute the SPLIT function of a non-/3 TJA1042 variant for the VIO function required by the /3 device.
Provide separate, stable VCC and VIO rails according to the device requirements: VCC must remain within 4.5V to 5.5V, while VIO supports 3V to 5V microcontroller interfacing. Place the VCC and VIO decoupling capacitors close to their corresponding pins and keep return-current paths short. Account for rail sequencing, startup transients, and the possibility that VIO or VCC may be removed before the CAN bus. The passive unpowered behavior helps bus integrity, but external protection and supply design still determine fault tolerance.
Do not treat a shared SOIC-8 footprint as proof that every related transceiver is interchangeable. The TJA1042T/3 uses the VIO interface arrangement, whereas the TJA1042T uses SPLIT on pin 5; related pin-function changes can make an apparently identical package electrically incompatible. Before substituting TCAN1042, TCAN1042H, or TJA1051T/3, compare TXD polarity, RXD behavior, STB polarity, supply thresholds, wake-up logic, and transceiver sleep states. Also verify the exact NXP ordering suffix and lifecycle position before committing the PCB to production.
규정 준수 정보
The NXP documentation identifies ISO 11898-2:2016 and SAE J2284-1 through SAE J2284-5 interface behavior, but explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals statements were not identified for the exact ordering code.