TJA1050T/VM - 1 Mbaud High-Speed CAN Transceiver | NXP
부품 번호: TJA1050T/VM ✗ 단종TJA1050T/VM 개요
A CAN transceiver, also called a CAN physical-layer interface, converts logic-level signals from a CAN controller into differential bus signals and converts received bus levels back into controller-compatible receive data. In the signal-chain hierarchy, the TJA1050 belongs to the CAN transceiver class, within interface ICs and broader semiconductor communications components. It supports the classic high-speed CAN physical layer used in automotive, industrial, and embedded control networks.
The principal device characteristics are a maximum signaling rate of 1 Mbaud, a 4.75 V to 5.25 V operating supply range, differential CANH and CANL bus connections, and an 8-pin SOIC package. The interface also includes a receive output, a transmit-data input, a silent-mode control input, and a VREF output for external bus-receiver biasing. These functions allow a CAN controller and physical bus to share a compact, application-specific interface.
In operation, the transmitter drives the CANH and CANL conductors differentially, while the receiver detects the dominant and recessive states presented on the bus. The silent-mode input can inhibit the transmitter when the controller is not actively participating in communication. The VREF pin provides a reference voltage for an optional split termination network, while CANH and CANL require the termination strategy appropriate for the complete CAN topology.
Typical applications include automotive body and powertrain control modules, industrial automation equipment, elevator controllers, building-control systems, robotics, and embedded CAN gateways. The TJA1050T/VM is especially suitable for legacy high-speed CAN systems requiring a conventional 5 V transceiver rather than a 3.3 V or CAN FD interface.
PCB implementation requires careful attention to the CAN bus pair, termination, grounding, and decoupling. Place the supply capacitor close to VCC, route CANH and CANL as a closely coupled differential pair, avoid discontinuities between transceiver and bus connector, and follow the termination guidance in the NXP TJA1050 datasheet for the selected topology.
This product page consolidates the TJA1050T/VM operating identity, lifecycle information, same-package alternatives, pin assignment, and practical interface-design guidance. It is intended to support legacy-product maintenance and informed migration planning while distinguishing genuine drop-in options from newer CAN transceivers that require different logic levels or pin assignments.
드롭인 대체품: TJA1050T/VM — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
TJA1050T/H/V,118
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
TJA1050T/CM,118
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
TJA1057T,118
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
TJA1021T/3
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
TJA1050T/VM 사양
| Product Type | High-speed CAN transceiver |
| Maximum Data Rate | 1 Mbaud |
| Supply Voltage Range | 4.75 V to 5.25 V |
| 핀 수 | 8 pins |
| 패키지 | 8-pin SOIC |
| 실장 유형 | Surface mount |
| CAN Interface | Differential CANH and CANL |
| Transmitter Input | TXD logic input |
| Receiver Output | RXD logic output |
| Silent-Mode Control | S input |
| Reference Output | VREF output |
| RoHS 상태 | Unknown |
| REACH Status | Unknown |
| AEC-Q100 Qualification | Unknown |
TJA1050T/VM 핀 구성
| 핀 1 | TXD — Transmit data input from the CAN controller |
| 핀 2 | GND — Ground connection |
| 핀 3 | S — Silent-mode input used to control transmitter operation |
| 핀 4 | RXD — Receive data output to the CAN controller |
| 핀 5 | VREF — Reference voltage output for the applicable termination arrangement |
| 핀 6 | CANH — CAN high-side bus connection |
| 핀 7 | CANL — CAN low-side bus connection |
| 핀 8 | VCC — Positive supply connection |
일반적인 애플리케이션
TJA1050T/VM 적합 용도: 6 애플리케이션s: Automotive Body Control Modules, Industrial Automation Equipment, Elevator and Building Control, Robotics and Embedded Control, CAN Bus Test and Measurement Equipment, Legacy Equipment Maintenance.
Automotive Body Control Modules
The TJA1050T/VM provides the physical layer between a CAN controller and vehicle body networks, with differential CANH and CANL signaling up to 1 Mbaud. Its 8-pin SOIC format supports compact control-module layouts, while TXD, RXD, and S provide the basic controller interface and transmitter-inhibit control. The 4.75 V to 5.25 V operating range suits established 5 V automotive electronics. For an existing module, the legacy footprint can simplify repair and stock-continuity work. The PCB must preserve the bus pair, provide suitable termination, and decouple VCC close to the device.
추천
Industrial Automation Equipment
The TJA1050T/VM suits industrial controllers, motor-control modules, remote I/O, and production equipment that use classic high-speed CAN. Its differential CAN interface reduces susceptibility to common-mode industrial noise, while the 1 Mbaud capability supports demanding control traffic. The interface uses TXD and RXD to connect to a protocol controller and provides S for silent operation during controller resets or maintenance. The small 8-pin SOIC package fits densely populated control boards. Layout should keep CANH and CANL tightly coupled, route them away from switching nodes, and follow the bus termination guidance in the NXP datasheet.
추천
Elevator and Building Control
The TJA1050T/VM can connect elevator controllers, door systems, and building-management nodes using a two-wire CAN bus. Its differential transmitter and receiver support communication between distributed nodes over distances typical of industrial building networks. The 1 Mbaud rate provides ample bandwidth for status, commands, and diagnostic traffic, while the compact SOIC-8 package simplifies retrofitting legacy controller boards. RXD and TXD connect to the CAN controller, S can inhibit transmission, and VREF supports the applicable split-termination arrangement. Existing installations benefit from same-package maintenance options, subject to electrical and lifecycle verification.
추천
Robotics and Embedded Control
The TJA1050T/VM is suitable for robot controllers, actuator hubs, sensor gateways, and embedded systems that retain a 5 V classic CAN interface. A 1 Mbaud physical layer allows controllers and distributed I/O to exchange real-time commands and diagnostics without introducing CAN FD hardware. The 8-pin SOIC footprint can be assembled into an existing controller layout without a package conversion. Designers should account for the transceiver's 5 V operating range and verify controller logic levels, bus termination, grounding, and fault behavior. The CANH and CANL tracks should behave as a controlled differential pair from the transceiver to the bus connector.
추천
CAN Bus Test and Measurement Equipment
The TJA1050T/VM can form the bus-facing section of a diagnostic adapter, protocol analyzer, or CAN interface card. Its 1 Mbaud capability covers classic high-speed CAN test traffic, and the differentiated receiver provides the physical-layer signal required by a controller or monitoring logic. The compact package allows multiple channels to be placed on an instrument board, while S offers a way to silence the transmitter when required by the test system. Accurate measurements depend on careful reference-ground design, low-noise supply decoupling, controlled bus-pair geometry, and termination appropriate to the analyzer connection.
추천
Legacy Equipment Maintenance
The TJA1050T/VM is especially useful for repairing or extending equipment whose original CAN controller expects a 5 V, 8-pin high-speed transceiver. The established SOIC-8 footprint can facilitate a maintenance replacement after the original component becomes difficult to procure. Because the NXP product page marks the TJA1050 family as end of life, engineers should verify stock, lifecycle risk, and any suffix-specific temperature or qualification requirements. A replacement should not be selected solely by package shape: TXD, RXD, S, VREF, supply voltage, bus thresholds, and fault behavior must match the original circuit.
추천
추천 제품 요약
엔지니어링 참조 데이터: TJA1050T/VM — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | TJA1050T/H/V,118 | TJA1050T/CM,118 | TJA1057T,118 | TJA1021T/3 |
|---|---|---|---|---|---|
| Package | SOIC-8 (8-SO) | SOIC-8 (8-SO) - same | SOIC-8 (8-SO) - same | SOIC-8 (8-SO) - same | SOIC-8 (8-SO) - same |
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Product Type | High-speed CAN transceiver | High-speed CAN transceiver | High-speed CAN transceiver | High-speed CAN transceiver | High-speed CAN transceiver |
| Maximum Data Rate | 1 Mbaud | 1 Mbaud | 1 Mbaud | 1 Mbaud | 1 Mbaud |
| Number of Pins | 8 pins | 8 pins | 8 pins | 8 pins | 8 pins |
| CAN Interface | Differential CANH/CANL | Differential CANH/CANL | Differential CANH/CANL | Differential CANH/CANL | Differential CANH/CANL |
주요 차별점
- Maintains the established TJA1050 controller and transceiver interface (vs TJA1021T/3)
- Provides a direct same-family path for TJA1050 maintenance designs (vs TJA1057T,118)
- Supports classic 1 Mbaud CAN without a CAN FD interface change (vs TJA1057T,118)
설계 노트
Route CANH and CANL as a continuous differential pair from pins 6 and 7 to the bus connector or termination point. Keep the pair closely coupled, minimize stubs, avoid routing across plane splits, and keep it away from switching regulators, relays, and high-current edges. Place the VCC decoupling capacitor close to pin 8 with a short ground return to pin 2. These layout controls protect differential signaling and reduce radiated emissions.
Do not treat a shared SOIC-8 footprint as sufficient proof of replacement compatibility. Confirm TXD, RXD, S, VREF, VCC, and GND assignments against the candidate datasheet, then compare logic thresholds, receiver hysteresis, bus-fault handling, TXD timeout behavior, and temperature range. Newer CAN FD devices may use different pin functions or logic rails and therefore require schematic or PCB changes rather than a drop-in substitution.
CAN bus nodes should use the termination arrangement specified by NXP for the complete network topology. Avoid placing long branches between a transceiver and the principal bus pair, because excessive stub length can increase reflections and emissions. Connect the transceiver ground to the system reference plane through a low-impedance path, and review the bus split location when VREF is used. Validate final radiated and conducted emissions on the completed assembly rather than relying only on schematic compliance.
Check the controller's TXD and RXD levels against the TJA1050T/VM input and output thresholds before using the device in a mixed-voltage design. The transceiver operates from 4.75 V to 5.25 V, but the digital interface must also meet the device's logic specifications. Provide local supply decoupling and minimize voltage drops between VCC and GND so controller and bus-interface devices see the same stable rail during bus activity.
규정 준수 정보
The NXP product information identifies the TJA1050 family as end of life, but the accessible product information does not state the requested compliance results. Suffix-specific qualification must be confirmed from NXP documentation before automotive use.