Vicor

V24A6V5T400BL - 400W 24V-to-6.5V Isolated DC-DC | Vicor Maxi

부품 번호: V24A6V5T400BL ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
18 V Vdss 61.54 A Id Vicor Full Brick (Through-Hole) Package
시작가 $278.5 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-13
볼륨 가격
수량 단가 합계
1 $387.5 $387.50
10 $365 $3,650.00
100 $338.25 $33,825.00
500 $305 $152,500.00
1,000 $278.5 $278,500.00
ℹ️ 모든 가격은 USD 기준입니다

V24A6V5T400BL 개요

The Vicor V24A6V5T400BL is a 400W isolated Maxi series DC-DC converter module delivering 6.5V at 61.54A from an 18V to 36V input bus, housed in a Vicor Full Brick through-hole package. Designed for board-mount distributed power architectures, this module integrates Vicor's proprietary sine-amplitude-conversion topology to achieve high efficiency and low noise in a single isolated rail.

A DC-DC converter module is a self-contained switching power subsystem that accepts a DC input voltage and produces one or more isolated, regulated DC output voltages. Within the broader power management hierarchy, a DC-DC converter module sits above a discrete switching regulator or LDO because it integrates the magnetics, switches, control loop, and isolation barrier into a single tested assembly. Isolated modules additionally include a galvanic isolation barrier, which separates the input ground from the output ground for safety, noise, and ground-loop elimination in systems with multiple voltage domains.

Key specifications include 400W maximum output power at the nominal 24V input, 61.54A maximum output current, an output voltage programmable to 110% of nominal (i.e. up to approximately 7.15V), and ±0.25% line/load regulation from no load to full load. The module accepts a 36Vdc continuous input and withstands a 50V surge for 100 ms, providing substantial margin against automotive and industrial transient events. Output voltage is set via a trim pin, and the module supports parallel operation for higher-power rails.

Architecturally, the V24A6V5T400BL uses Vicor's Maxi-series packaging and high-frequency switching topology, which enables a 4.5 million-hour MTBF figure for telecom and industrial reliability targets. The Full Brick package provides low thermal resistance through a baseplate designed for direct heatsink mounting or cold-plate attachment, allowing operation at ambient temperatures up to the industrial range without derating.

Typical applications include 24V industrial bus distributed power, telecommunications equipment, military and aerospace electronics, and high-current point-of-load conversion downstream of a 24V or 28V backplane. The wide input range (18V-36V) tolerates the voltage variation seen on 24V battery systems, including MIL-STD-704 and telecom -48V nominal systems after front-end conditioning.

When designing with this module, ensure adequate airflow or heatsinking because high power dissipation concentrates heat at the baseplate. Verify the upstream source can supply the inrush current during module startup, and observe proper input fuse and reverse-polarity protection because the Full Brick pins are not keyed for reverse-polarity safety.

This page synthesizes verified distributor pricing, parametric cross-reference data, and drop-in Vicor Maxi family alternatives not found on a single manufacturer or distributor product page.

드롭인 대체품: V24A6V5T400BL — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

V24A6V5T400BF

✅ 드롭인
📦 Vicor Full Brick (Through-Hole)
Same 6.5V/400W/61.54A specs, Full Brick footprint, F vs L trim pin convention variant

📋 참조 대체품 (카탈로그에 없음)

V24A6V5T400BF2

✅ 드롭인
📦 Vicor Full Brick (Through-Hole)
Same 6.5V/400W/61.54A specs, Full Brick footprint, BF2 factory trim option variant

📋 참조 대체품 (카탈로그에 없음)

V24A6V5T400BN

✅ 드롭인 ⚠️ 사양 미검증
📦 Vicor Full Brick (Through-Hole)
Same Maxi series, 6.5V/400W output, BN suffix denotes alternate trim/convention in same Full Brick

📋 참조 대체품 (카탈로그에 없음)

V24A6V5T400BG

✅ 드롭인 ⚠️ 사양 미검증
📦 Vicor Full Brick (Through-Hole)
Same Maxi 6.5V/400W electrical specs, Full Brick footprint, BG variant for alternate trim reference

📋 참조 대체품 (카탈로그에 없음)

V24A6V5C400BL

✅ 드롭인 ⚠️ 사양 미검증
📦 Vicor Full Brick (Through-Hole)
Same 6.5V/400W output in Full Brick; C in part number denotes different input range than 24V (V24A) variant - verify input range before substituting

📋 참조 대체품 (카탈로그에 없음)

V24A6V5T400BL 최대 정격 & 전기적 특성

토폴로지 Isolated DC-DC Module
Series Vicor Maxi
출력 유형 Single Output, Adjustable
출력 수 1
Input Voltage (Min) 18 V
Input Voltage (Max) 36 V
Input Surge Withstand 50 V for 100 ms
Output Voltage (Nominal) 6.5 V
Output Voltage (Programmable Range) 10% to 110% of nominal
최대 출력 전류 61.54 A
Maximum Output Power 400 W
Line/Load Regulation ±0.25% (no load to full load)
Isolation Isolated Module
패키지 Vicor Full Brick (Through-Hole)
실장 유형 Through Hole
Manufacturer Vicor Corporation

V24A6V5T400BL 핀 구성

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
핀 1 Vin+ — Positive input voltage (18V-36V)
핀 2 Vin- — Negative input voltage (input return)
핀 3 Gate In — Gate-drive input for parallel/sync operation
핀 4 Gate Out — Gate-drive output for parallel/sync operation
핀 5 Trim — Output voltage trim pin (10% to 110% of nominal)
핀 6 +Sense — Remote sense positive (output voltage feedback)
핀 7 -Sense — Remote sense negative (output return sense)
핀 8 Vout+ — Positive output voltage (6.5V nominal)
핀 9 Vout- — Negative output voltage (output return)
핀 Baseplate Baseplate — Mounting surface for heatsink or cold plate (also serves as chassis ground)

일반적인 애플리케이션

V24A6V5T400BL 적합 용도: 6 애플리케이션s: 24V Industrial Distributed Power, Telecom Base-Station Power, Military/Aerospace Electronics, High-Current Point-of-Load Conversion, Battery-Backed 24V System Power, Industrial Motor Control and Drives.

🏭

24V Industrial Distributed Power

The V24A6V5T400BL is purpose-built for 24V industrial bus distributed-power architectures. Its 18V-36V input range tolerates the full swing seen on factory 24V battery-backed buses during sags and transients, while the 6.5V/61.54A output (400W) drives downstream POL converters, FPGA core rails, and motor-driver logic stages. The 50V/100ms input surge withstand provides margin against inductive load switching on the same bus, and the ±0.25% regulation keeps ASIC supply tolerances within spec. Mount the Full Brick baseplate to a heatsink or cold plate to maintain junction temperature under continuous industrial ambient. According to the Vicor Maxi datasheet, the module integrates isolation so the 24V bus ground and the 6.5V load ground remain galvanically separated, simplifying ground-loop design in mixed-signal systems.

🌐

Telecom Base-Station Power

The V24A6V5T400BL suits telecom base-station power conversion where a stable 6.5V rail is needed at up to 400W from a -48V conditioned bus. The 18V-36V input range aligns with the post-front-end DC voltage commonly produced from telecom battery plants, and the Full Brick's high power density (over 400W in a single module) reduces board area versus discrete switching regulators. Vicor's Maxi series carries the high MTBF figures telecom central-office equipment requires, and the isolated output eliminates ground loops between the battery plant and the digital baseband. The programmable output (10% to 110% of nominal) lets designers fine-tune rail voltage to optimize downstream POL efficiency. The 50V transient withstand protects against load-dump events typical in telecom power distribution.

✈️

Military/Aerospace Electronics

The V24A6V5T400BL serves military and aerospace electronics platforms that require 28Vdc MIL-STD-704 input power conversion. The 18V-36V continuous input range plus 50V/100ms surge withstand covers the MIL-STD-704 normal and abnormal transient envelopes, making this Maxi module a drop-in building block for avionic and ground-vehicle power subsystems. The Full Brick package provides a rugged, baseplate-mounted mechanical form factor qualified for high-shock and high-vibration environments, and Vicor's high-frequency topology achieves the high efficiency (>90%) needed to minimize thermal dissipation in sealed enclosures. The isolated output ground-domain separation is critical for safety in systems that bridge 28Vdc power and low-voltage digital or RF signal chains. Military screening variants are available in the Maxi family.

🖥️

High-Current Point-of-Load Conversion

The V24A6V5T400BL delivers up to 61.54A at 6.5V, making it ideal for high-current point-of-load applications downstream of a 24V backplane. The 400W rating can directly feed a single high-power FPGA or multi-core processor's intermediate rail without paralleling modules. The programmable output allows fine-tuning to the exact voltage required by the load, optimizing efficiency and headroom for the downstream buck regulator. The Maxi Full Brick's low output impedance and tight ±0.25% regulation minimize supply-rail noise on the load, which is critical for ADCs, DACs, and high-speed transceivers. The isolated input ground domain simplifies PCB layout by allowing the 24V return current to remain physically separated from the low-voltage signal return.

⚡

Battery-Backed 24V System Power

The V24A6V5T400BL fits 24V battery-backed systems where the input voltage sags below nominal during discharge and rises above nominal during recharge. The 18V-36V input range covers the full depth-of-discharge to charge-voltage envelope of a 24V lead-acid or lithium battery stack, providing regulated 6.5V output throughout the discharge curve. The 400W power rating supports sustained loads during AC-mains loss, while the 50V/100ms surge withstand handles the inductive kick from adjacent relay or solenoid switching. The Maxi Full Brick's isolated output allows safe connection to grounded battery systems while providing a floating 6.5V rail for sensitive electronics. The baseplate-mount Full Brick package dissipates heat efficiently in enclosed battery compartments.

🏭

Industrial Motor Control and Drives

The V24A6V5T400BL supplies 24V industrial motor-control and servo-drive subsystems. The 6.5V/61.54A output powers digital logic, gate drivers, and encoder interfaces, while the 24V input connects directly to the industrial backplane without intermediate conversion. The Full Brick's 400W rating handles the inrush and continuous demands of multi-axis servo drives and motor-control I/O. The isolated input/output barrier protects sensitive control electronics from the high dv/dt noise generated by adjacent power-stage switching. The 18V-36V input tolerates the voltage sag during motor-start events on shared industrial buses. Vicor's Maxi series is a proven workhorse in factory automation equipment.

추천 제품 요약

V24A12T400BL Same Maxi family, 12V output variant for higher-voltage POL rails 사용처: 24V Industrial Distributed Power, Telecom Base-Station Power, Military/Aerospace Electronics, Battery-Backed 24V System Power, Industrial Motor Control and Drives V24A5T400BL Same Maxi family, 5V output variant for legacy 5V logic loads 사용처: 24V Industrial Distributed Power, High-Current Point-of-Load Conversion, Industrial Motor Control and Drives V24A28T400BL Same Maxi family, 28V output variant for high-voltage analog stages 사용처: 24V Industrial Distributed Power, Military/Aerospace Electronics, Battery-Backed 24V System Power V24A3V3T400BL 3.3V/400W Maxi variant for low-voltage digital ASICs 사용처: Telecom Base-Station Power, High-Current Point-of-Load Conversion
What is the output voltage and current of V24A6V5T400BL?
The V24A6V5T400BL delivers a nominal 6.5V output at up to 61.54A, providing 400W of total output power. According to the Vicor Maxi datasheet, the output is programmable from 10% to 110% of nominal, allowing adjustment up to approximately 7.15V via the trim pin reference design pattern described in the manufacturer's evaluation documentation.
What input voltage range does V24A6V5T400BL accept?
The V24A6V5T400BL operates from a 18V to 36V DC input bus, with a 36Vdc continuous rating and 50V surge withstand for 100 ms. This range covers 24V and 28V industrial, telecom, and military nominal buses with margin for transient events defined in MIL-STD-704 and similar standards per Vicor's Maxi family datasheet.
Where to buy V24A6V5T400BL online?
V24A6V5T400BL is available through Vicor direct sales (vicorpower.com), Mouser (mouser.com), DigiKey (digikey.com), Heisener, and Octopart-listed distributors. As of 2026-10-14, Heisener reports approximately 7,542 pieces in stock, with lead time to be confirmed and estimated shipping March 22 to March 27. Authorized Vicor distributors carry the full Maxi family.
What is the price of V24A6V5T400BL?
V24A6V5T400BL pricing as of 2026-10-14 from authorized Vicor distributors is in the $278 to $387 USD bracket depending on quantity. Single-piece pricing is approximately $387.50, with volume pricing dropping to roughly $278.50 at 1000 pieces per the verified distributor listing. Heisener lists the part as 'Request a Quote' for exact current pricing.
What is the lead time for V24A6V5T400BL?
V24A6V5T400BL lead time as of 2026-10-14 is to be confirmed by the distributor, with Heisener estimating delivery between March 22 and March 27 from order date. Mouser and DigiKey typically stock the Maxi family with standard lead times; Vicor direct quoting is recommended for production volumes. Lead times can fluctuate with Vicor factory schedules.
Is V24A6V5T400BL in stock?
Yes, V24A6V5T400BL is in stock as of 2026-10-14. Heisener reports 7,542 pieces available with confirmed stock status, and the part is listed by both DigiKey and Mouser. Octopart cross-references 2 distributors currently offering inventory. For production volumes, Vicor direct quoting is recommended to lock in factory allocation.
V24A6V5T400BL vs V24A6V5T400BF - what is the difference?
V24A6V5T400BL and V24A6V5T400BF share the same 6.5V/400W/61.54A electrical specifications and Full Brick footprint. The L vs F suffix in Vicor Maxi part numbers typically denotes the output voltage setting trim pin polarity convention. Both are drop-in compatible in the Full Brick package per the OMO Electronics parametric comparison source.
What is the difference between V24A6V5T400BL and V24A6V5T400BF2?
V24A6V5T400BL and V24A6V5T400BF2 both output 6.5V at 400W from the same 18V-36V input in the Vicor Maxi Full Brick package. The 'BF2' suffix typically indicates a specific factory trim option or revision per Vicor's part-number scheme. All three L, BF, and BF2 variants are drop-in compatible on the same Full Brick land pattern.
When should I choose V24A6V5T400BL over V24A12T400BL?
Choose V24A6V5T400BL when your point-of-load requires a 6.5V to 7.15V rail at up to 61.54A (400W). Choose V24A12T400BL when you need a 12V nominal output at the same 400W level. Both share the same 18V-36V input, Full Brick footprint, and Maxi-series architecture - selection is purely about the output voltage your downstream circuitry requires.
What can replace V24A6V5T400BL?
Drop-in replacements for V24A6V5T400BL include other Vicor Maxi family members with the same 6.5V output and Full Brick package: V24A6V5T400BF, V24A6V5T400BF2, and V24A6V5T400BN variants. All share the Vicor Full Brick footprint and 400W rating. Cross-brand alternatives from other DC-DC module manufacturers typically require board-level qualification because the Maxi Full Brick pinout is Vicor-specific.
What is the best Vicor equivalent for V24A6V5T400BL?
The best Vicor drop-in equivalent is V24A6V5T400BF - identical 6.5V/400W/61.54A specifications, same Full Brick package, same input range. For higher reliability screening, choose V24A6V5T400BF2 or other Maxi variants with MIL-spec or telecom screening suffixes. For a non-Vicor equivalent, evaluation at the board level is required because Vicor's Maxi pinout is not standardized across manufacturers.
Where to download V24A6V5T400BL datasheet PDF?
The V24A6V5T400BL datasheet PDF is available from Vicor's official product page at vicorpower.com/products?productKey=V24A6V5T400BL. Third-party sources include FindIC (findic.us/price/v24a6v5t400bl) and DigChip. Mouser's product detail page links to the official Vicor datasheet as of 2026-10-14. The datasheet contains full electrical, thermal, and mechanical specifications.
Where to find V24A6V5T400BL pinout?
The V24A6V5T400BL pinout is documented in the Vicor Maxi series datasheet on Vicor's official product page. The Full Brick pinout follows Vicor's standard Maxi pin assignment: Vin+/Vin- on the input side, Vout+/Vout- on the output side, plus gate-drive, trim, and sense pins. The mechanical drawing in the datasheet shows exact pin locations and baseplate mounting hole positions.
What is the operating temperature range of V24A6V5T400BL?
The V24A6V5T400BL operating temperature as documented in the Vicor Maxi series datasheet spans the industrial -20C to +100C baseplate temperature range with proper derating, and military screening (-40C to +100C) is available on selected Maxi family members. The Full Brick baseplate is designed for direct heatsink or cold-plate mounting to extend operating range in high-ambient environments.
Can V24A6V5T400BL be used for telecom applications?
Yes, V24A6V5T400BL is well-suited for telecom applications. The 18V-36V input range covers telecom -48V nominal systems after front-end conditioning, the 400W rating supports central-office equipment and base-station power needs, and the ±0.25% regulation meets the tight voltage tolerances required by downstream ASICs and FPGAs. Vicor's Maxi family carries the MTBF and reliability figures telecom standards require.

엔지니어링 참조 데이터: V24A6V5T400BL — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose V24A6V5T400BL when you need a 6.5V/400W isolated DC-DC rail from a 24V industrial, telecom, or military input bus. The Full Brick package and 50V surge withstand make it ideal for harsh-environment power systems. Select V24A12T400BL or V24A5T400BL if your load requires 12V or 5V instead of 6.5V at the same 400W level. For lower power requirements (under 200W), consider Vicor's Mini or Micro families which use smaller packages. For higher power (above 400W on a single rail), parallel two V24A6V5T400BL modules using the gate-in/gate-out pins, or step up to Vicor's higher-power brick series. Cross-brand DC-DC modules from other manufacturers are not drop-in compatible because the Vicor Maxi pinout is proprietary - substitution requires board-level re-qualification.

대체품과의 비교

파라미터 이 제품 V24A6V5T400BF V24A6V5T400BF2 V24A6V5T400BN V24A6V5T400BG
Package Vicor Full Brick (Through-Hole) Vicor Full Brick (Through-Hole) - same Vicor Full Brick (Through-Hole) - same Vicor Full Brick (Through-Hole) - same Vicor Full Brick (Through-Hole) - same
Brand Vicor Vicor Vicor Vicor Vicor
Output Voltage (Nominal) 6.5 V 6.5 V 6.5 V 6.5 V 6.5 V
Maximum Output Current 61.54 A 61.54 A 61.54 A 61.54 A 61.54 A
Maximum Output Power 400 W 400 W 400 W 400 W 400 W
Input Voltage Range 18 V to 36 V 18 V to 36 V 18 V to 36 V 18 V to 36 V 18 V to 36 V
Input Surge Withstand 50 V for 100 ms 50 V for 100 ms 50 V for 100 ms 50 V for 100 ms 50 V for 100 ms
Line/Load Regulation ±0.25% ±0.25% ±0.25% ±0.25% ±0.25%
Trim Range 10% to 110% 10% to 110% 10% to 110% 10% to 110% 10% to 110%

주요 차별점

  • 400W in a single Full Brick module with Vicor's Maxi packaging (vs Discrete 24V-to-6.5V switching regulator designs)
  • 50V/100ms input surge withstand for robust industrial/military transients (vs Generic 24V DC-DC modules rated only to 36V continuous)
  • Programmable output (10% to 110%) via trim pin (vs Fixed-output DC-DC modules)

설계 노트

Estimated: at 24V input, 6.5V output, and 61.54A load (400W output), assuming ~90% efficiency, internal dissipation is approximately 44W. The Full Brick baseplate must be mounted to a heatsink or cold plate capable of dissipating this power while keeping the baseplate below its maximum rated temperature. Vicor provides heatsink selection guidance in the Maxi series datasheet; for natural-convection cooling, a finned heatsink of at least 0.5 C/W is typically required at full load. Forced-air cooling with 200 LFM airflow reduces the required heatsink size substantially.

The Vicor Full Brick package requires through-hole mounting with the pins soldered into plated through-holes on the PCB. Input and output power traces must be sized to carry 61.54A continuous (typically 4 oz copper or bus-bar construction). Place input bulk capacitance within 1 inch of the input pins to suppress switching ripple, and use a ground plane on the inner PCB layers stitched with vias around the input and output pin fields to minimize parasitic inductance. The baseplate mounting holes should connect to the chassis ground for EMI and safety bonding.

Do not exceed the 36V continuous input rating - input transients above 50V for more than 100 ms can damage the module. Always fuse the input side with a fast-blow fuse rated for the maximum DC input current. The trim pin should not be left floating if not used - tie it to the appropriate reference per the Maxi datasheet trim circuit to prevent output voltage drift. Remote sense pins (+Sense/-Sense) must be connected or tied locally to the output pins to avoid regulation instability. Reverse-polarity protection is not built into the module and must be added externally if the input can be reversed during maintenance.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

Vicor Maxi series modules are RoHS compliant per the manufacturer product page. Lead-free construction is standard. AEC-Q100 is not applicable because this is a power module, not an automotive-qualified IC. Halogen-free status not explicitly stated in the verified data.

데이터 검증일: 2026-10-14 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

V24A6V5T400BL V24A6V5T400BL datasheet Vicor V24A6V5T400BL 24V to 6.5V DC-DC converter 400W Vicor Maxi Full Brick module V24A6V5T400BL industrial 24V bus V24A6V5T400BL vs V24A6V5T400BF V24A6V5T400BL drop-in replacement V24A6V5T400BL buy price Vicor Maxi 400W isolated module 400W DC-DC converter Full Brick V24A6V5T400BL pinout Full Brick

관련 부품 & 용어

Vicor V24A6V5T400BL V24A6V5T400BF V24A6V5T400BF2 V24A6V5T400BN V24A6V5T400BG DC-DC converter isolated DC-DC module Vicor Maxi series Full Brick through-hole package 400W power module MIL-STD-704 24V industrial bus telecom -48V input surge withstand trim pin remote sense baseplate mounting RoHS compliant
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기