Renesas Electronics

ICS502MIT - 140MHz PLL Clock Generator | Renesas | SOIC-8

MPN: ICS502MIT ✓ Aktif
8-pin SOIC, 0.154 inch (3.90 mm) width Package 140 MHz Speed
MOQ: 1 |

ICS502MIT Ringkasan

Renesas Electronics ICS502MIT is a LOCO PLL clock-generator IC that produces a high-quality clock output and reference from a lower-frequency crystal or clock input. The device supports frequencies up to 140 MHz and is packaged in an 8-pin SOIC measuring 0.154 inch, or 3.90 mm, in width. Its CMOS output architecture is intended for systems that require a stable high-frequency timing signal without using a high-cost dedicated clock-generation solution.

A PLL clock multiplier is an integrated timing circuit that compares a reference signal with a divided version of its internally generated output, then adjusts the output until the two signals are phase and frequency aligned. In the product hierarchy, the ICS502MIT is a clock generator, a frequency synthesizer, and ultimately an integrated timing IC. Its LOCO architecture is intended to multiply a low-frequency reference into higher-frequency clock and reference outputs using fewer external components than traditional discrete frequency-generation approaches.

The main specifications identify the ICS502MIT as a one-circuit PLL clock generator with crystal or clock input, CMOS output, and no differential input or output. The maximum supported frequency is 140 MHz. The documented input-to-output ratio for the MIT variant is listed as 2:2. The SOIC-8 package supports surface-mount assembly and provides a compact solution for industrial, communications, networking, test, and measurement equipment.

Clock-generating ICs are useful when one low-frequency reference must be converted into a higher-frequency timing signal with predictable phase behavior. The ICS502MIT can serve as the central timing element in a clock tree or as a local clock source for digital logic, processors, interface circuits, and mixed-signal systems. Because its output is CMOS, downstream devices must be evaluated for input-voltage compatibility, rise and fall time requirements, fanout, and termination needs.

Typical clock-generation applications include communications equipment, frequency conversion, digital control systems, instrumentation, and general-purpose timing subsystems. A crystal-connected implementation is appropriate when the board needs a stable frequency reference, while a clock-input implementation can support an existing system clock. In either topology, output loading, trace length, grounding, and decoupling remain critical because clock edges must reach downstream devices within their timing specifications.

Design with the external crystal or reference network, supply decoupling, and output termination specified by the manufacturer datasheet. Confirm the selected reference frequency, multiplication ratio, and resulting maximum output frequency before layout. If an existing board must be changed, compare every pin, power rail, output type, and timing parameter against the original device rather than assuming that a similarly described clock generator is interchangeable.

This product page consolidates the verified ICS502MIT device identity, frequency, PLL, I/O, package, and sourcing details with practical clock-tree guidance. It also distinguishes documented device characteristics from parameters that must be confirmed in the manufacturer datasheet before qualification or production release.

Pilihan pengganti yang segera untuk ICS502MIT — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.

Tiada pilihan pengganti yang segera untuk produk ini.

Minta Alternatif

ICS502MIT Spesifikasi

Product Type Clock Generator IC
Architecture LOCO PLL clock multiplier
Maximum Frequency 140 MHz
Number of Circuits 1 circuit
Input Type Clock or crystal
Jenis Output CMOS
Input-to-Output Ratio 2:2
Differential Input No
Differential Output No
PLL Yes
Kemasan 8-pin SOIC, 0.154 inch (3.90 mm) width
Jenis Pemasangan Surface mount
Manufacturer Renesas Electronics Corporation

Panduan Konfigurasi Pin ICS502MIT 8-pin soic, 0.154 inch (3.90 mm) width

Konfigurasi pin untuk ICS502MIT (8-pin soic, 0.154 inch (3.90 mm) width pakai). Penomeran pin, fungsi, dan garis bentuk koneksi ditakrifkan dalam dokumen pengeluar. Rujuk dokumen untuk kebentuk dan pedoman pengasman.

Garis bentuk pengecah pakai 8-pin soic, 0.154 inch (3.90 mm) width untuk ICS502MIT

Tiada data garisan pin yang diperoleh untuk ICS502MIT.

Rujuk kepada lembaran data untuk konfigurasi pin penuh.

Aplikasi Biasa

ICS502MIT patut untuk 6 aplikasis: Communications Clock Tree, Industrial Control Timing, Test and Measurement Instrumentation, Digital Logic Clock Distribution, Frequency Conversion Subsystem, Network Interface Timing.

🌐

Communications Clock Tree

The ICS502MIT fits a local clock-tree node that requires a single-ended CMOS timing signal derived from a lower-frequency crystal or system reference. Its PLL-based LOCO architecture can multiply the reference to a frequency as high as 140 MHz, allowing a communications board to distribute clocking to compatible digital logic without adding a larger clock-generator package. The 8-pin SOIC-8 footprint supports compact surface-mount layouts. Before implementation, confirm the reference frequency, required multiplication ratio, jitter budget, output loading, and downstream input thresholds against the manufacturer datasheet.

🏭

Industrial Control Timing

ICS502MIT can provide a compact, multiplexed timing reference for an industrial controller when the system uses single-ended CMOS clocking and operates below the device's documented 140 MHz maximum frequency. The PLL approach is useful when a stable low-frequency crystal reference must drive logic requiring a higher-frequency clock. Its 8-pin SOIC-8 package and one-circuit architecture simplify board-area allocation. Designers must still verify supply voltage, temperature range, clock rise and fall time, fanout, isolation strategy, and conducted-emissions requirements in the final control platform.

🔧

Test and Measurement Instrumentation

The ICS502MIT is suitable for timing blocks in test and measurement instruments that need a compact PLL-derived CMOS clock from a crystal or external reference. A single high-frequency output can support compatible counters, data converters, digital controllers, or interface circuits while reducing discrete frequency-multiplication components. The maximum documented frequency of 140 MHz provides a clear upper boundary for initial architecture selection. Instrument designs should evaluate output drive, reference jitter, spur content, grounding, and cable or trace loading because the clock quality ultimately determines the accuracy of downstream measurements.

🖥️

Digital Logic Clock Distribution

ICS502MIT can act as the local generator feeding a single-ended CMOS clock network for processors, programmable logic, memory interfaces, or other digital peripherals. The one-circuit PLL topology produces a higher-frequency output from a lower-frequency reference, while the SOIC-8 package keeps the implementation compact. The design must account for edge-rate degradation, capacitive loading, fanout limitations, and return-path continuity on the PCB. Use short clock routes where possible, preserve a continuous ground reference, and confirm that each receiver's minimum pulse-width and input-level requirements are satisfied.

📡

Frequency Conversion Subsystem

The ICS502MIT can be used in a frequency-conversion subsystem that requires a stable reference multiplied from a crystal or external clock into a higher-frequency CMOS signal. Its PLL-based clock-multiplier function is particularly relevant to boards that need local frequency generation without relying on a distant system clock. The verified 2:2 ratio for this variant should be checked against the intended system architecture rather than generalized across every ICS502 suffix. Engineers should also account for reference startup time, loop settling, output jitter, and startup behavior in sequential acquisition or communication systems.

🌐

Network Interface Timing

ICS502MIT can support a network interface that needs a locally generated, single-ended CMOS reference clock. The 140 MHz maximum frequency makes it relevant to timing blocks operating below that ceiling, while the SOIC-8 package is convenient for compact interface cards. A design should ensure that the chosen reference and PLL configuration meet the interface controller's frequency tolerance, jitter, and duty-cycle requirements. PCB implementation must also separate the clock route from noisy switching stages, provide a solid ground plane, and account for connector or cable loading where the clock leaves the board.

Ringkasan Produk Disebarkan

ICS502 Related ICS502 LOCO PLL clock-multiplier family member Dipergunakan di: Communications Clock Tree, Industrial Control Timing, Test and Measurement Instrumentation, Digital Logic Clock Distribution, Frequency Conversion Subsystem, Network Interface Timing ICS502MIT Renesas Electronics Dipergunakan di: Communications Clock Tree, Industrial Control Timing, Test and Measurement Instrumentation, Digital Logic Clock Distribution, Frequency Conversion Subsystem, Network Interface Timing
What is the ICS502MIT?
The ICS502MIT is a Renesas Electronics LOCO PLL clock-generator IC that converts a low-frequency crystal or clock reference into a high-quality clock output and reference. According to the manufacturer datasheet listing, it uses a PLL, provides a CMOS output, and supports frequencies up to 140 MHz in an 8-pin SOIC package. It is useful where a compact timing source is needed for digital logic, communications, or test equipment.
What is the maximum frequency of ICS502MIT?
The maximum frequency of the ICS502MIT is 140 MHz. This value is identified in the manufacturer datasheet listings for the exact ICS502MIT orderable part. Maximum operating frequency does not mean every external reference can drive the output directly to 140 MHz, because the selected crystal, reference frequency, multiplication ratio, and configuration must also satisfy the device's operating requirements.
Where can I download the ICS502MIT datasheet PDF?
The ICS502MIT datasheet PDF can be reached through the linked manufacturer-datasheet listing for the exact part. The document is identified as a four-page LOCO PLL Clock Multiplier datasheet, but the page count should be confirmed when opening the file. Use the pin-description table, electrical characteristics, reference-circuit diagrams, and application information in that document before assigning PCB connections.
What are the key specifications of ICS502MIT that engineers should know?
The ICS502MIT is a one-circuit PLL clock generator with a maximum frequency of 140 MHz, crystal or clock input, and a CMOS output. The verified device listing identifies an 8-pin SOIC package measuring 0.154 inch, or 3.90 mm, in width, plus a 2:2 input-to-output ratio for this variant. Non-differential input and output further define its role as a single-ended timing source.
Does ICS502MIT use a PLL and what outputs does it provide?
Yes, the ICS502MIT uses a LOCO PLL to generate a high-frequency clock output and a reference from a lower-frequency crystal or clock input. Its output interface is CMOS, and the verified listing specifies no differential input or output. The practical benefit is a compact frequency-multiplication stage that can feed compatible single-ended timing circuits without a full differential clock architecture.
Can ICS502MIT be used with a crystal or an external clock?
The ICS502MIT accepts either a crystal or an external clock as its timing reference. According to the manufacturer datasheet description, it is designed to generate a high-quality, high-frequency clock output and reference from a lower-frequency source. The correct crystal value, load capacitance, source impedance, and bypass components should be selected using the reference configuration in the manufacturer datasheet.
How does ICS502MIT compare with the ICS502 family?
The ICS502MIT is the specified SOIC-8 orderable variant of the ICS502 LOCO PLL clock-multiplier family. The exact ICS502MIT listing identifies a 140 MHz maximum frequency, one clock-generator circuit, crystal or clock input, CMOS output, and a 2:2 ratio. Because the base ICS502 listing does not establish identical suffix-level electrical details, engineers should verify the exact MPN before treating another family member as interchangeable.
When should I choose ICS502MIT instead of a general-purpose clock source?
Choose the ICS502MIT when a compact, surface-mount PLL clock multiplier with crystal or external-clock input is appropriate for the design. Its documented 140 MHz ceiling and single-ended CMOS output suit conventional timing architectures. A different clock generator should be selected when the design requires differential outputs, a different package, another output ratio, or operating limits outside the specifications of the exact ICS502MIT variant.
Is ICS502MIT suitable for communications and industrial equipment?
The ICS502MIT can be suitable for communications and industrial timing subsystems when its 140 MHz maximum frequency, single-ended CMOS output, and external reference arrangement meet the system requirements. Its SOIC-8 surface-mount package supports compact assembly. Temperature range, supply voltage, output drive, jitter, and electromagnetic-emissions requirements must be checked in the manufacturer datasheet before a design is released.
Where can I buy ICS502MIT and check current availability?
Use the Request a Quote form on this page to ask for ICS502MIT availability, current lead time, order quantity, and purchasing conditions. The verified distributor listing describes the exact part as available for purchase and shipping, but inventory changes continuously. Requesting a quote against the exact MPN, package, temperature grade, and required quantity avoids accidental substitution.
What is the price of ICS502MIT?
Use the Request a Quote form on this page for the current ICS502MIT price and quantity breaks. Pricing is refreshed through the sourcing workflow because market availability and order quantities can change. Include the exact MPN ICS502MIT and state whether the required quantity is for prototype evaluation, production assembly, or scheduled replenishment.
What is the lead time for ICS502MIT?
Request the current ICS502MIT lead time through the Request a Quote form on this page. Lead time depends on the ordered quantity, manufacturing availability, and shipment destination. State the required delivery date and production forecast with the request so the supplier can confirm the earliest feasible allocation for the exact 8-pin SOIC device.
Is ICS502MIT in stock?
Current ICS502MIT inventory should be confirmed through the Request a Quote form on this page. The verified distributor listing reports that the part can be purchased and ships today, but stock levels can change without notice. Provide the required quantity and manufacturing schedule when requesting confirmation, especially for production builds that need allocation across multiple releases.
What can replace ICS502MIT?
No verified pin-to-pin drop-in replacement for the exact ICS502MIT was established from the available cross-reference results. A replacement must use the same 8-pin SOIC footprint, preserve the crystal or clock input, CMOS output, 2:2 variant configuration, and remain within the required frequency, voltage, temperature, jitter, and drive parameters. Do not substitute a clock generator solely because its maximum frequency is similar.
What is the best cross-brand equivalent for ICS502MIT?
The best cross-brand equivalent cannot be selected responsibly without a validated cross-reference containing pin-level and parametric data. A candidate must match the 8-pin SOIC footprint, use a compatible crystal or clock-input topology, provide the required CMOS output, and satisfy the exact frequency and ratio requirements of ICS502MIT. Request a drop-in cross-reference or provide the complete electrical specification to the sourcing team for engineering review.

Data referensi kejuruteraan untuk ICS502MIT — perbandingan, panduan rancangan, dan maklumat kesediaan

Panduan Pilihan

Select the ICS502MIT when the design needs a compact, surface-mount PLL clock generator with a crystal or external clock input, a single-ended CMOS output, and operation up to 140 MHz. It is particularly attractive for conventional clock trees that do not require differential signaling and can use the exact part's documented 2:2 configuration. The base ICS502 family may be relevant when an exact suffix, temperature grade, or ratio is needed, but the engineer must verify suffix-level specifications before using another family member.

Do not treat an arbitrary 140 MHz clock generator as interchangeable. The correct candidate must also match the 8-pin SOIC-8 footprint, pin assignment, crystal or clock-input architecture, supply voltage, output drive, temperature range, and timing characteristics. For a replacement, request a validated cross-reference and compare every electrical and pin-level requirement. If the system requires differential clocks, adjustable ratios, multiple independent outputs, or a package other than SOIC-8, choose a device specifically designed for those requirements rather than forcing an unreviewed substitution.

Perbandingan dengan Gantian

Parametr Produk Ini
Package 8-pin SOIC, 0.154 inch (3.90 mm) width
Brand Renesas Electronics
Product Type Clock Generator IC
Architecture LOCO PLL clock multiplier
Maximum Frequency 140 MHz
Number of Circuits 1 circuit
Input Type Clock or crystal
Output Type CMOS
Input-to-Output Ratio 2:2
Differential I/O No differential input or output

Penyeberangsung Jelas

  • Compact single-circuit PLL clock generation (vsICS502)
  • Defined 140 MHz operating class (vsICS502)
  • Single-ended CMOS integration (vsICS502)

Catatan Desain

Place the crystal or reference-clock source, its required passive network, and the ICS502MIT input pins close together to minimize sensitive-loop area and input pickup. Keep the clock output on a short, continuous route with a nearby ground reference. The SOIC-8 package supports compact placement, but minimizing loop area is especially important for a high-frequency PLL clock because trace inductance and capacitance can affect startup, edge quality, and timing margin.

Follow the manufacturer reference circuit for supply decoupling and connect the decoupling capacitor close to the device's supply and ground pins. Separate the clock-generator supply route from noisy switching nodes where practical. Verify the selected regulator can start and remain stable with the reference oscillator's operating current, and avoid routing clock edges across split or interrupted ground-plane boundaries.

Do not select a replacement solely by maximum frequency. A drop-in candidate must use the same 8-pin SOIC footprint and preserve the crystal or clock-input architecture, CMOS output, relevant 2:2 configuration, supply requirements, and timing characteristics. Also verify reference frequency, output drive, temperature grade, and package dimensions. A functionally similar PLL with different pin assignments can prevent startup, distort the output, or create unsafe shorts on an existing board.

Evaluate clock amplitude, rise and fall time, duty cycle, and loading at the actual receiver rather than relying only on nominal frequency. CMOS outputs can experience edge degradation when driving long traces or high capacitance. If the clock reaches a connector, cable, or long PCB route, consider buffering or matched termination according to the interface requirements, and keep the return path continuous to prevent additional jitter or timing uncertainty.

Maklumat Kesediaan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Bosong logam timbal
Unknown
Bosong halogen
Unknown
Mineral konflik
Unknown

No compliance declarations were present in the verified device listings. Compliance status must be confirmed from the current manufacturer documentation or declaration before qualification.

Data disahkan pada: 2026-11-16 — data yang disahkan dan disusun semula oleh pasukan kejuruteraan komponen XAIPART

Pencarian Berhubungan

ICS502MIT datasheet ICS502MIT pinout ICS502MIT datasheet pdf ICS502MIT 140MHz ICS502MIT SOIC-8 ICS502MIT CMOS clock generator ICS502MIT PLL multiplier ICS502MIT crystal input ICS502MIT equivalent ICS502MIT replacement ICS502MIT vs ICS502 Renesas ICS502MIT ICS502MIT price ICS502MIT stock ICS502MIT application circuit

Komponen dan Tanda berkaitan

Renesas Electronics ICS502MIT ICS502 LOCO PLL clock generator clock multiplier frequency synthesizer integrated timing IC CMOS output crystal oscillator external clock input PLL 140 MHz 2:2 frequency ratio 8-pin SOIC SOIC-8 surface-mount package single-ended clock communications equipment industrial control test and measurement network interface clock tree reference clock
RFRC Saring Pantas
Isikan butiran lengkap — pasukan jualan kami akan bertindak balas dalam masa 24 jam
Nombor Bahagian Pengeluar Pakej QTY Harga Target Lengkap
✓
Pesan diskon sudah disubmit!

Kami akan bertindak balas kepada emel anda dalam tempoh 24 jam

1
RFQ Diserahkan
2
kutipan Diterima
3
Order Dipesan
4
Pembayaran
5
Dihantar
6
Diantar
Lihat Perincian RFQ