Rockwell Automation

1734-4IOL - POINT I/O 4-Channel IO-Link Master Module

MPN: 1734-4IOL ✓ Active
In Stock Ships in 1-3 business days
From $985 USD / Unit
MOQ: 1 |
Price updated: 2026-10-20
Volume Pricing
Qty Unit Price Extended
1 $1100 $1,100.00
10 $1075 $10,750.00
100 $1040 $104,000.00
500 $1010 $505,000.00
1,000 $985 $985,000.00
ℹ️ All prices are in USD

1734-4IOL Overview

The Allen-Bradley 1734-4IOL is a POINT I/O 4-channel IO-Link master module designed to bridge intelligent IO-Link sensors and actuators to an EtherNet/IP-based Logix control system. As a Series B POINT I/O module, the 1734-4IOL installs on a standard 1734 terminal base and connects upstream through a 1734-AENT or 1734-AENTR Ethernet adapter, exposing four independent IO-Link ports that conform to the IO-Link v1.0/1.1 specification. Each channel supports standard digital input, standard digital output, IO-Link, Fallback, or Disabled modes, allowing a mix of conventional discrete I/O and full bidirectional IO-Link communication on the same module.

An IO-Link master is a fieldbus gateway that provides a point-to-point digital communication channel between a controller and a single IO-Link device (sensor or actuator), serving as the IO-Link backbone in the industrial sensor-to-cloud hierarchy (IO-Link device -> IO-Link master -> fieldbus/industrial Ethernet -> PLC/DCS). IO-Link sits below traditional fieldbus layers, replacing analog and discrete wiring with a standardized 3-wire (or 4-wire for high-power actuators) point-to-point link that delivers process data, diagnostic data, and parameter data on demand. The 1734-4IOL brings this standard into the Allen-Bradley POINT I/O distributed-I/O platform, enabling Logix controllers to read and write IODD-described parameters, configure devices via IODD, and react to real-time diagnostic events.

Key features include four Class A IO-Link ports, per-port short-circuit and overload protection, automatic IODD file storage with revision tracking, and a configurable process-data length per channel. The module draws field power (24V DC) from the POINT I/O backplane through its terminal base, separating it from the backplane communication power so that field-side faults do not affect network connectivity. Configuration is performed in Studio 5000 Logix Designer using the supplied Add-On Profile (AOP), which exposes every port mode, device identity, IODD revision, process-data size, validation policy, and field-power calculation in a structured tree view, simplifying replacement and reuse.

Typical applications include factory-floor sensor aggregation on packaging machinery, robot end-effector tooling identification on assembly cells, condition-monitoring vibration sensor networks, and vision-system lighting controller integration. The compact 12.7 mm-wide housing allows high-density I/O in control cabinets where panel space is limited, and the conformal-coated 1734-4IOLK variant extends operation into harsh-environment applications such as food and beverage washdown areas.

When designing with this module, ensure that the terminal base matches the wiring requirements (1734-TB, 1734-TBS, 1734-TB3, or 1734-TB3S) and that the upstream 1734-AENT(R) adapter firmware revision is compatible with the desired Logix Designer version. Field power budgeting must account for the sum of attached IO-Link device currents, and IODD files must be loaded into the AOP before commissioning to unlock vendor-specific parameters.

Drop-in alternatives for 1734-4IOL — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

1734-4IOLK

✅ Drop-In
📦 POINT I/O 12.7 mm module
same die and footprint as 1734-4IOL, adds conformal coating for harsh environments

📋 Reference alternative (not in catalog)

1734-4IOL Series A

✅ Drop-In
📦 POINT I/O 12.7 mm module
previous Series A hardware revision, same footprint and IO-Link functionality but older firmware feature set

📋 Reference alternative (not in catalog)

1734 POINT I/O 4ch IO-Link

✅ Drop-In
📦 POINT I/O 12.7 mm module
current production Series B with firmware 4.011, identical hardware to 1734-4IOL, refreshed firmware revision

📋 Reference alternative (not in catalog)

1734-4IOL Specifications

Catalog Number 1734-4IOL
Series B
Module Type POINT I/O 4-Channel IO-Link Master
Number of Channels 4
IO-Link Specification v1.0 / v1.1 compliant
Port Modes Standard DI, Standard DO, IO-Link, Fallback, Disabled
Upstream Communication POINT I/O backplane via 1734-AENT or 1734-AENTR adapter
Configuration Software Studio 5000 Logix Designer with Add-On Profile (AOP)
Mounting DIN rail via 1734 terminal base (TB/TBS/TB3/TB3S)
Required Adapter 1734-AENT or 1734-AENTR
Conformal Coated Variant 1734-4IOLK (same specs, conformal coated)
Housing Width 12.7 mm
Application Environment In-cabinet (1734-4IOL), harsh-environment (1734-4IOLK)
Accessories 1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S, 1734-TOP, 1734-TOPS, 1734-TOP3, 1734-TOP3S

1734-4IOL standard Pin Configuration Guide

Pin configuration for 1734-4IOL (standard package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.

standard package pinout diagram for 1734-4IOL

No detailed pinout data available for 1734-4IOL.

Refer to the datasheet for full pin configuration.

Typical Applications

1734-4IOL is suitable for 7 applications: Packaging Machinery Sensor Aggregation, Robotic End-Effector Tool Identification, Condition Monitoring Vibration Sensor Network, Vision-System Lighting Controller Integration, Food and Beverage Washdown Skid, Automotive Body Shop IO-Link Network, Pharmaceutical Cleanroom Distributed I/O.

🏭

Packaging Machinery Sensor Aggregation

The 1734-4IOL aggregates up to four smart packaging-line sensors - such as label-presence, cap-detection, fill-level, and vision-system lighting - on a single POINT I/O node, eliminating parallel discrete wiring harnesses. Each IO-Link channel carries process data, diagnostic data, and parameter data from a vendor-supplied IODD file into Logix Designer, so engineers can read and write parameters without manual HMI screens. The module's 12.7 mm housing width allows high-density placement next to conveyor motors in compact packaging cells, and the per-channel fallback mode provides graceful degradation when an IO-Link device is disconnected or replaced.

🤖

Robotic End-Effector Tool Identification

On robotic assembly cells, the 1734-4IOL reads tool-ID and condition-monitoring data from IO-Link-tagged grippers, vacuum generators, and torque tools over a single 3-wire M12 cable per channel. The IO-Link master's deterministic cycle time lets the controller validate the tool before each pick, while diagnostic data flags worn gripper pads before they cause scrap. Because the module sits on the POINT I/O backplane next to the robot controller, the same Studio 5000 project handles both motion and IO-Link configuration, simplifying commissioning.

📡

Condition Monitoring Vibration Sensor Network

Vibration and temperature sensors with IO-Link interfaces stream high-resolution FFT data and RMS trends into a 1734-4IOL, enabling predictive-maintenance logic inside the Logix controller. The four-channel density allows grouping sensors by machine (motor, pump, gearbox, bearing housing) on a single module, simplifying cabling to the field and reducing the number of POINT I/O nodes in the cabinet. With per-channel IODD management, the AOP tracks firmware revisions of attached sensors and warns when a device's IODD is out of date.

📺

Vision-System Lighting Controller Integration

IO-Link-controlled LED lights expose brightness, color temperature, and strobe-timing parameters over a single 3-wire cable, and the 1734-4IOL can manage up to four lighting zones per module. The studio-5000 AOP lets vision engineers tune lighting recipes from the Logix program rather than from vendor-specific configurators, which simplifies recipe-changeover for SKUs in mixed-model production lines. Field-power budgeting through the AOP ensures the total lighting current does not exceed the 24V backplane budget.

💧

Food and Beverage Washdown Skid

On washdown-rated food-and-beverage skids, the conformal-coated 1734-4IOLK variant provides the same four IO-Link master channels as the standard module while withstanding caustic cleaning agents, humidity, and condensation. Hygienic IO-Link sensors for temperature, conductivity, level, and flow all run from IODD files managed by the AOP, allowing batch traceability data to flow directly into the Logix recipe. The 12.7 mm housing width keeps the cabinet footprint small, which is critical on compact skid packages.

🚗

Automotive Body Shop IO-Link Network

In automotive body shops, the 1734-4IOL serves as a four-channel IO-Link master for clamp pressure sensors, weld-current monitors, and RFID tool-ID readers distributed across robotic weld cells. The EtherNet/IP backplane through the 1734-AENT(R) adapter supports deterministic multicast IO, allowing weld-quality data to be aggregated in real time for SPC dashboards. The per-channel validation policy in the AOP prevents unauthorized IO-Link device swaps from silently changing process behavior on safety-relevant weld cells.

💊

Pharmaceutical Cleanroom Distributed I/O

The 1734-4IOL supports cleanroom-grade IO-Link sensors for differential pressure, particle counters, and temperature/humidity probes where discrete analog wiring would be costly and noisy. Each channel's IODD file describes the sensor's full parameter set - including calibration date and last-cleaned timestamp - enabling GMP-compliant audit trails inside the Logix controller. The compact DIN-rail housing minimizes cabinet depth, which is valuable in cleanrooms where wall space is dedicated to HEPA filtration rather than enclosures.

Recommended Products Summary

1734-AENT Upstream EtherNet/IP adapter required for 1734-4IOL Used in: Packaging Machinery Sensor Aggregation, Condition Monitoring Vibration Sensor Network, Pharmaceutical Cleanroom Distributed I/O 1734-TB3 Spring-style wiring base compatible with 1734-4IOL Used in: Packaging Machinery Sensor Aggregation 1734-AENTR Dual-port EtherNet/IP adapter for 1734-4IOL Used in: Robotic End-Effector Tool Identification, Vision-System Lighting Controller Integration, Automotive Body Shop IO-Link Network 1734-TB Screw-style wiring base for 1734-4IOL Used in: Robotic End-Effector Tool Identification, Automotive Body Shop IO-Link Network 1734-TBS Spring-style wiring base compatible with 1734-4IOL Used in: Condition Monitoring Vibration Sensor Network 1734-TB3S Spring-style wiring base compatible with 1734-4IOL Used in: Vision-System Lighting Controller Integration 1734-4IOLK Conformal-coated variant of 1734-4IOL for washdown environments Used in: Food and Beverage Washdown Skid, Pharmaceutical Cleanroom Distributed I/O 1734-TOP3S Spring-style power base compatible with 1734-4IOLK Used in: Food and Beverage Washdown Skid
What is the Allen-Bradley 1734-4IOL used for?
The 1734-4IOL is a POINT I/O 4-channel IO-Link master module that connects up to four IO-Link sensors or actuators to a Logix controller over EtherNet/IP via a 1734-AENT or 1734-AENTR adapter. According to the Rockwell Automation installation instructions, each channel can run in IO-Link, standard digital input, standard digital output, Fallback, or Disabled mode, allowing mixed conventional and smart-device wiring on one module.
Which adapter does the 1734-4IOL require?
The 1734-4IOL requires a 1734-AENT or 1734-AENTR Ethernet adapter as part of the POINT I/O backplane. According to the apter.com datasheet mirror, the module is not a stand-alone device; it communicates upstream through the adapter and is configured in a Logix Designer environment using the supplied AOP.
How many IO-Link ports does the 1734-4IOL have?
The 1734-4IOL provides four independent IO-Link ports, each with its own mode, process-data length, IODD revision, and validation policy. According to the user manual 1734-UM020D-EN-E, the Channel tree in Logix Designer displays each port individually so engineers can configure and monitor all four channels from a single module.
What is the difference between 1734-4IOL and 1734-4IOLK?
The 1734-4IOLK is the conformal-coated variant of the 1734-4IOL and shares identical electrical and functional specifications. According to Rockwell Automation publication 1734-IN043E-EN-E, catalog numbers suffixed with 'K' are conformal coated for harsh-environment applications, while the base specifications remain the same as the non-coated catalogs.
Is the 1734-4IOL still in production?
Yes, the 1734-4IOL is currently active in production as a Series B module. According to the Rockwell Automation Product Compatibility and Download Center, the 1734-4IOL B Series firmware is at revision 4.011 as of the latest entry, with current AOP, EDS, and IODD support files published for Logix Designer environments.
How much does the 1734-4IOL cost?
The 1734-4IOL is priced around $1,100 per unit for single-piece purchases as of 2026-10-20, based on distributor listings such as Precision Electric. Volume discounts from authorized Rockwell distributors typically reduce the price to roughly $985 per unit at 1000-piece quantities.
Where can I download the 1734-4IOL datasheet PDF?
The official 1734-4IOL datasheet, installation instructions (1734-IN043E-EN-E), and user manual (1734-UM020D-EN-E) are published on the Rockwell Automation Literature Library at literature.rockwellautomation.com. According to the Rockwell Automation technical documentation page, the Add-On Profile, EDS files, and IODD files are downloadable from the Product Compatibility and Download Center using the catalog number 1734-4IOL.
Can the 1734-4IOL replace an Allen-Bradley 1734 discrete I/O module?
The 1734-4IOL can functionally replace many discrete I/O configurations because each of its four channels supports standard digital input, standard digital output, IO-Link, Fallback, or Disabled modes. According to the apter.com datasheet, engineers should preserve every port mode, device identity, IODD revision, process-data size, validation policy, and field-power calculation when migrating from a pure discrete module.
What is the difference between 1734 POINT I/O and 5034 PointMax I/O?
The 1734 POINT I/O platform, including the 1734-4IOL, has been an industry staple for over 25 years with the broadest third-party support base. According to TW Controls, the newer 5034 PointMax I/O is a higher-performance next-generation platform from Rockwell Automation that is not a drop-in replacement; migrating requires re-engineering the backplane, adapter, and program structure.
What terminal bases work with the 1734-4IOL?
The 1734-4IOL is compatible with 1734-TB, 1734-TBS, 1734-TB3, and 1734-TB3S wiring base assemblies. According to the Allen-Bradley installation manual on ManualsLib, the spring-style and screw-style bases give engineers flexibility for either vibration-resistant spring terminations or traditional screw terminations, and the choice depends on the cabinet wiring preference rather than module functionality.
How do I configure IODD files on the 1734-4IOL?
IODD (IO Device Description) files are loaded into the Add-On Profile for the 1734-4IOL inside Studio 5000 Logix Designer. According to Rockwell Automation publication 1734-UM020D-EN-E, the IODD unlocks vendor-specific parameters and process data layouts that are not visible with generic IO-Link profiles, and the AOP tracks IODD revision per channel for lifecycle management.
Is the 1734-4IOL suitable for harsh-environment applications?
Standard 1734-4IOL modules are intended for in-cabinet use; for harsh environments, the conformal-coated 1734-4IOLK variant is the drop-in solution. According to the Rockwell Automation product page, the K-suffix module carries the same electrical and functional specifications as the base 1734-4IOL but adds a conformal coating that protects against humidity, dust, and corrosive atmospheres common in food and beverage washdown areas.
What is the input voltage of the 1734-4IOL?
The 1734-4IOL draws 24V DC field power from the POINT I/O backplane through its terminal base, with separate power rails for backplane communication and field-side I/O. Specific voltage tolerance and current draw figures should be cross-checked against the official 1734-IN043E-EN-E installation instructions, as the precise minimum and maximum input voltages were not present in the provided web data.
What firmware version does the 1734-4IOL B Series use?
The 1734-4IOL B Series current firmware revision is 4.011 according to the Rockwell Automation Product Compatibility and Download Center. According to the PCDC listing, Series B is the most recent production series; engineers planning a Logix Designer upgrade should confirm that their AOP, EDS, and IODD files match this firmware revision before commissioning.
Is there a Siemens or competitor equivalent for the 1734-4IOL?
There is no true pin-for-pin drop-in equivalent to the 1734-4IOL outside the Allen-Bradley POINT I/O ecosystem, because the module is mechanically keyed to the 1734 terminal-base footprint and integrates with the proprietary 1734-AENT(R) backplane. According to industrial cross-reference listings, third-party alternatives from Siemens SIMATIC ET 200, Phoenix Contact Axioline, or Wago I/O System 750 offer equivalent IO-Link master functionality but require full panel re-engineering rather than a simple module swap.

Engineering reference data for 1734-4IOL — comparison, design guidance, and compliance information.

Selection Guide

Choose the Allen-Bradley 1734-4IOL when you need to integrate IO-Link smart sensors and actuators into a Logix-controlled system that already uses the POINT I/O distributed-I/O platform, or when you want a single module that can mix standard digital I/O and IO-Link on the same four channels. Choose the 1734-4IOLK conformal-coated variant for harsh-environment zones such as food-and-beverage washdown, outdoor panels, or corrosive atmospheres, with the same electrical specifications. For new installations that have not standardized on POINT I/O, evaluate the Siemens SIMATIC ET 200, Phoenix Contact Axioline, or Wago 750 IO-Link masters as alternative platforms, noting that none of these are pin-for-pin drop-in replacements for the 1734-4IOL and will require full panel re-engineering. For predictive-maintenance vibration networks, the 1734-4IOL is also the canonical choice because Logix Designer can directly consume the FFT process data and trigger alarms without a third-party middleware layer.

Comparison with Alternatives

Parameter This Product 1734-4IOLK 1734-4IOL Series A
Brand Rockwell Automation (Allen-Bradley) Rockwell Automation (Allen-Bradley) Rockwell Automation (Allen-Bradley)
Package POINT I/O 12.7 mm module POINT I/O 12.7 mm module (conformal coated) POINT I/O 12.7 mm module
Number of Channels 4 IO-Link master channels 4 IO-Link master channels 4 IO-Link master channels
IO-Link Specification v1.0 / v1.1 v1.0 / v1.1 v1.0 / v1.1
Series Series B (firmware 4.011) Series B (firmware 4.011) Series A (legacy firmware)
Conformal Coating No (standard module) Yes (harsh-environment rated) No
Required Adapter 1734-AENT or 1734-AENTR 1734-AENT or 1734-AENTR 1734-AENT or 1734-AENTR

Key Differentiators

  • Only POINT I/O module with both standard digital I/O and IO-Link on every channel (vs Generic 1734 discrete modules)
  • Add-On Profile exposes IODD revision, process-data size, and validation policy per channel (vs Manual IO-Link commissioning via vendor tools)
  • Available with conformal coating for harsh-environment washdown zones (vs Standard 1734-4IOL (in-cabinet only))

Design Notes

Field-power budgeting is critical when designing with the 1734-4IOL: the sum of all attached IO-Link device supply currents (per channel, including actuator high-current pulses) must not exceed the 24V DC field-power budget of the upstream 1734-AENT or 1734-AENTR adapter. The Logix Designer AOP exposes a field-power calculation tool that should be filled in during commissioning; ignoring this calculation is a common cause of intermittent field-power brownouts that falsely look like IO-Link device faults.

Mount the 1734-4IOL only on a 1734 terminal base that matches the wiring style (1734-TB / 1734-TB3 for screw, 1734-TBS / 1734-TB3S for spring). Spring bases are strongly preferred in cabinets subject to vibration - such as those mounted on packaging skids or near stamping presses - because screw terminations can loosen over time and produce intermittent IO-Link faults that mimic sensor failures. Always torque screw bases to the value specified in publication 1734-IN043E-EN-E.

Do not migrate from a 1734 discrete I/O module to the 1734-4IOL without preserving every port mode, device identity, IODD revision, process-data size, validation policy, and field-power calculation in the new Logix program. According to the apter.com datasheet mirror, silent mismatches in IODD revision or process-data size are the most common cause of 'no communication' faults after a swap. Always export and re-import the AOP configuration rather than recreating tags by hand.

Series A and Series B 1734-4IOL modules share the same footprint but differ in firmware features. Mixing series inside a single POINT I/O bank may work mechanically but can produce inconsistent behavior if the AOP expects Series B features (such as enhanced IODD revision tracking). Standardize on a single series per cabinet and document the choice in the program comments for future maintainers.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

RoHS, REACH, and lead-free status for the 1734-4IOL were not explicitly present in the provided web data; consult the official Rockwell Automation product environmental compliance documentation for current declarations. AEC-Q100 is not applicable as this is an industrial automation module rather than an automotive-grade semiconductor.

Data verified on: 2026-10-20 — data verified and curated by XAIPART's component engineering team

Related Searches

1734-4IOL datasheet 1734-4IOL price Allen-Bradley 1734-4IOL manual POINT I/O 4 channel IO-Link master 1734-4IOL vs 1734-4IOLK Rockwell 1734-4IOL buy 1734-4IOL IO-Link version 1.1 1734-4IOL AOP download 1734-4IOL Studio 5000 configuration what adapter does 1734-4IOL require 1734-4IOL replacement for discrete module 1734-4IOL conformal coated washdown

Related Components & Terms

Rockwell Automation Allen-Bradley 1734-4IOL 1734-4IOLK 1734 POINT I/O 1734-AENT 1734-AENTR IO-Link IO-Link v1.0 IO-Link v1.1 EtherNet/IP Logix Designer Studio 5000 Add-On Profile (AOP) IODD 1734-TB 1734-TBS 1734-TB3 1734-TB3S POINT I/O backplane industrial distributed I/O conformal coating Series B firmware 4.011 field-power budgeting Class A IO-Link port
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details