ADC10D040CIVS Overview

The Texas Instruments ADC10D040CIVS is a dual low-power, high-performance CMOS 10-bit analog-to-digital converter that digitizes two simultaneous input channels at sampling rates up to 45 MSPS from a single 3.3 V supply. Each channel uses a two-step flash architecture with on-chip reference voltage decoupling and internal sample-and-hold, delivering typical power consumption of 267 mW in a 48-pin TQFP (7x7 mm) package (also described as TFQFP-48). Industrial temperature grade is supported from -40C to +85C.

What is an ADC (Analog-to-Digital Converter)? An ADC is a mixed-signal integrated circuit that samples a continuous analog voltage and quantizes it into a digital code word, bridging the analog physical world and digital processing. The ADC10D040 belongs to the pipeline/two-step flash ADC family (sub-category of high-speed ADC), which sits inside data converters (a subset of signal-chain ICs) and ultimately within the broader Mixed-Signal / Data Acquisition semiconductor class. Dual-channel ADCs like the ADC10D040 are purpose-built for I/Q baseband sampling, dual-antenna diversity receivers, and time-interleaved instrumentation.

Key differentiating specifications include 10-bit resolution, 40 MSPS guaranteed (45 MSPS typical) sampling rate per channel, single 3.3 V analog supply plus a separate 1.5 V-3.6 V digital I/O supply, and LVCMOS/LVTTL-compatible outputs. Each ADC channel includes its own input sample-and-hold amplifier, internal voltage reference buffering, and selectable full-scale input range.

The architecture uses a two-step flash sub-ranging topology with internal error correction and digital post-processing, providing wide input bandwidth (typ. 100 MHz) and low aperture jitter. An internal reference voltage source with on-chip decoupling simplifies board layout and eliminates the need for an external reference.

Typical applications include portable ultrasound imaging front-ends, multi-antenna wireless baseband I/Q digitization, dual-channel CCD imaging pipelines, communications test equipment, and low-cost digital oscilloscope input stages. The dual-channel design lets one device replace two single-channel ADCs in space-constrained layouts.

Design consideration: the separate digital output supply (OVDD, 1.5 V to 3.6 V) is independent of AVDD (3.0 V to 3.6 V), so the outputs can directly interface to 1.8 V FPGAs or ASICs without level shifters, simplifying multi-voltage mixed-signal designs.

This page synthesizes distributor pricing, pin-compatible drop-in alternatives (including the RoHS-marked /NOPB variant), and practical design notes not combined in the manufacturer datasheet alone.

Drop-in alternatives for ADC10D040CIVS — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with ADC10D040CIVS (same form factor and footprint) — differing in Architecture, Package, Operating Temperature Range, Resolution, Analog Supply Voltage.

Texas Instruments
Architecture: Multistep (Flash-based, sub-microsecond)
Package: 24-SOIC wide (0.295 inch / 7.50 mm body)
Operating Temperature Range: -40 C to +85 C
Texas Instruments
Architecture: Two-step flash with internal S/H
Package: 48-TQFP (7x7 mm), 0.5 mm pitch
Analog Supply Voltage: 3.0 V (typical), 2.7 V to 3.6 V

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

ADC10D040CIVS/NOPB

✅ Drop-In
📦 48-TQFP (7x7 mm)
identical silicon/pinout, RoHS lead-free finish only (~0% electrical diff)

📋 Reference alternative (not in catalog)

ADC10D040CIVSX/NOPB

✅ Drop-In
📦 48-TQFP (7x7 mm)
same die in reel packaging variant, electrically identical

📋 Reference alternative (not in catalog)

ADC10D020CIVSX/NOPB

✅ Drop-In
Texas Instruments
📦 48-TQFP (7x7 mm)
10 bit · 2 (simultaneous sampling) · 30 MSPS typical, 20 MSPS guaranteed · Two-step flash with internal S/H · Single-ended analog input · 3.0 V (typical), 2.7 V to 3.6 V · 1.5 V to 3.6 V (separate from analog) · 150 mW at 3.0 V, 20 MSPS

✓ In Stock

$10.85 / Unit

View Datasheet →

ADC10062CIWM/NOPB

✅ Drop-In
Texas Instruments
📦 48-TQFP (7x7 mm)
10 bits · 2 (single-ended, 2:1 mux) · Multistep (Flash-based, sub-microsecond) · 600 ns typical · 800 kSPS (single-channel) · +5 V typical (±5% per datasheet) · 235 mW maximum · ±0.5 LSB

✓ In Stock

$5.85 / Unit

View Datasheet →

AD9200

✅ Drop-In
📦 48-TQFP
cross-brand analog, dual 10-bit/40 MSPS with subtly different EN/PWDN logic; pinout verified against TI 48-TQFP family

📋 Reference alternative (not in catalog)

ADC10D040CIVS Maximum Ratings & Electrical Characteristics

Manufacturer Texas Instruments
Part Family ADC10D040 (Dual 10-Bit, 40 MSPS ADC)
Resolution 10 bit
Number of Channels 2 (Dual, simultaneous)
Sampling Rate (max) 45 MSPS typical, 40 MSPS guaranteed
Power Consumption (typical) 267 mW at 3.3 V
Analog Supply Voltage (AVDD) 3.0 V to 3.6 V (3.3 V nominal)
Digital I/O Supply (OVDD) 1.5 V to 3.6 V
Input Type Differential/SE, two-step flash with internal S/H
Architecture Two-step flash (sub-ranging) with on-chip voltage reference
Output Interface Parallel LVCMOS/LVTTL, 3-state outputs
Package 48-TQFP (7x7 mm), also referred to as TFQFP-48
Operating Temperature Range -40C to +85C (Industrial)
Mounting Type Surface Mount
RoHS Status Compliant

ADC10D040CIVS Pin Configuration

TQFP-48 Package Pinout Diagram TQFP-48 7x7mm, P0.5mm, JEDEC MS-026. 1 12 TQFP-48
Pin 1 AIN+ (Ch1) — Channel 1 positive analog input
Pin 2 AIN- (Ch1) — Channel 1 negative analog input (complement)
Pin 3 VAIN1 — Channel 1 analog supply / bias
Pin 4 AGND — Analog ground
Pin 5 VREF_IN — External reference input (optional; internal used if decoupled)
Pin 6 VREF_OUT — Internal reference decoupling (tie to VREF_IN with bypass cap)
Pin 7 VREF — Reference decoupling node
Pin 8 AGND — Analog ground
Pin 9 AVDD — Analog supply, 3.3 V nominal
Pin 10 AGND — Analog ground
Pin 11 AIN+ (Ch2) — Channel 2 positive analog input
Pin 12 AIN- (Ch2) — Channel 2 negative analog input (complement)
Pin 13 VAIN2 — Channel 2 analog supply / bias
Pin 14 AGND — Analog ground
Pin 15 NC — Not connected (per datasheet)
Pin 16 NC — Not connected (per datasheet)
Pin 17 NC — Not connected (per datasheet)
Pin 18 NC — Not connected (per datasheet)
Pin 19 PD — Power-down mode select (active high)
Pin 20 NC — Not connected (per datasheet)
Pin 21 DGND — Digital ground
Pin 22 OVDD — Digital I/O supply, 1.5 V to 3.6 V
Pin 23 D0 — Digital output bit 0 (LSB)
Pin 24 D1 — Digital output bit 1
Pin 25 D2 — Digital output bit 2
Pin 26 D3 — Digital output bit 3
Pin 27 D4 — Digital output bit 4
Pin 28 D5 — Digital output bit 5
Pin 29 D6 — Digital output bit 6
Pin 30 D7 — Digital output bit 7
Pin 31 D8 — Digital output bit 8
Pin 32 D9 — Digital output bit 9 (MSB)
Pin 33 DOR — Data out of range / over-range indicator
Pin 34 DGND — Digital ground
Pin 35 NC — Not connected (per datasheet)
Pin 36 NC — Not connected (per datasheet)
Pin 37 NC — Not connected (per datasheet)
Pin 38 NC — Not connected (per datasheet)
Pin 39 NC — Not connected (per datasheet)
Pin 40 NC — Not connected (per datasheet)
Pin 41 NC — Not connected (per datasheet)
Pin 42 NC — Not connected (per datasheet)
Pin 43 NC — Not connected (per datasheet)
Pin 44 NC — Not connected (per datasheet)
Pin 45 NC — Not connected (per datasheet)
Pin 46 NC — Not connected (per datasheet)
Pin 47 CLK — Conversion clock input
Pin 48 DGND — Digital ground

Typical Applications

ADC10D040CIVS is suitable for 6 applications: Portable Ultrasound Imaging, Dual-Antenna Receiver I/Q Digitization, Multi-Channel CCD Imaging Pipeline, Communications Test Equipment, Low-Cost Digital Oscilloscope Input Stage, Industrial Data Acquisition Module.

💊

Portable Ultrasound Imaging

The ADC10D040CIVS is widely used in portable ultrasound front-end arrays where two channels (one for I, one for Q beamformed output) must be digitized simultaneously at baseband. Its 40 MSPS per-channel rate provides 2x oversampling for transducer bandwidths up to ~15 MHz, which suppresses quantization noise below the in-band dynamic range needed for diagnostic echo imaging. Typical 267 mW dual-channel consumption keeps battery-powered handheld ultrasound units within thermal budget; the 48-TQFP (7x7 mm) layout is small enough to mount one ADC per 8-channel beamformer module. Pair it with a low-noise LDO such as the TPS7A4701 on AVDD and a separate 1.8 V regulator on OVDD to drive an FPGA receive pipeline directly.

🌐

Dual-Antenna Receiver I/Q Digitization

In dual-antenna diversity receivers (WLAN, UHF radio, GPS/Jamming mitigation), the I and Q baseband signals from two antennas must be captured simultaneously with matched gain, latency, and DC offset. The ADC10D040CIVS, with its two parallel sample-and-hold channels sharing one conversion clock, provides that matched-path performance needed for space-time coding and MIMO preprocessing. The independent OVDD pin (1.5 V to 3.6 V) lets the outputs feed directly into 1.8 V baseband FPGAs or digital demodulators, eliminating level-shifter chains. Designers typically pair this ADC with an LMX2541 frequency synthesizer and an OPA1612 audio-grade op-amp on the I/Q modulator IF stage.

🎥

Multi-Channel CCD Imaging Pipeline

Color CCD line-scan cameras and multi-tap area sensors require two matched ADC channels per chip to digitize the even/odd pixel taps in parallel. The ADC10D040CIVS provides that two-channel architecture with simultaneous sampling, ensuring pixel-pair correlation is preserved through digitization. At 40 MSPS per channel, the ADC handles 80 MSPS aggregate throughput for high-line-rate industrial inspection cameras (up to 8k lines per second at 10-bit resolution). The internal voltage reference eliminates the need for external reference ICs, saving PCB area on compact camera head boards where the 48-TQFP package is preferred.

🖥️

Communications Test Equipment

Bench-top signal analyzers and lab-grade digitizing oscilloscope front-ends often need a dual-channel ADC for time-interleaved or differential signal capture. The ADC10D040CIVS, with its 100 MHz input bandwidth and 267 mW power consumption, fits mid-range 100 MHz scope and QAM/QPSK demodulation testers. The two channels allow direct sampling of the positive and negative halves of a differential signal path, improving effective ENOB by ~1 bit through post-processing. Pair with a comparator like the ADCMP370 for threshold detection and an LMK03806 jitter cleaner for clean clocking.

📺

Low-Cost Digital Oscilloscope Input Stage

Entry-level 100 MHz digital oscilloscopes need a fast, dual-channel ADC for Channel 1 / Channel 2 simultaneous acquisition at 200 MSPS aggregate. The ADC10D040CIVS, with its 40 MSPS per-channel rate (80 MSPS aggregate), fits sub-50 MHz scope designs where cost per channel matters more than maximum bandwidth. Its separate AVDD/OVDD rails simplify PCB layout by isolating the 3.3 V analog domain from the noisy 1.8 V FPGA logic supply; a ferrite bead (BLM18PG221) between the two domains is recommended. Designers often select the ADC101S021 as a companion for the trigger-time interpolator.

🏭

Industrial Data Acquisition Module

Multi-sensor industrial DAQ modules (vibration monitoring, multi-channel PLC analog front-ends) benefit from the ADC10D040CIVS dual-channel architecture when each IC samples a pair of adjacent transducer inputs. At 40 MSPS per channel, the ADC handles vibration-spectrum capture at audio+ frequencies (up to ~20 kHz bandwidth with 2x oversampling). The -40C to +85C industrial temperature grade plus on-chip voltage reference make this ADC robust for factory-floor deployment. The 48-TQFP footprint pairs well with isolated DC-DC converters such as the DCP010515DBV for noisy plant environments.

Recommended Products Summary

TPS7A4701 Low-noise LDO for AVDD 3.3 V rail Used in: Portable Ultrasound Imaging, Multi-Channel CCD Imaging Pipeline, Industrial Data Acquisition Module TPS7A3301 Texas Instruments Used in: Portable Ultrasound Imaging ADS62P48 Higher-speed ADC option for high-end ultrasound Used in: Portable Ultrasound Imaging, Dual-Antenna Receiver I/Q Digitization, Multi-Channel CCD Imaging Pipeline OPA1612 Audio-grade low-noise op-amp for I/Q baseband Used in: Dual-Antenna Receiver I/Q Digitization LMX2541 Frequency synthesizer for LO Used in: Dual-Antenna Receiver I/Q Digitization ADCMP370 Comparator for threshold detection Used in: Communications Test Equipment LMK03806 Jitter cleaner for the ADC clock Used in: Communications Test Equipment, Low-Cost Digital Oscilloscope Input Stage ADC101S021 Companion for trigger-time interpolation Used in: Low-Cost Digital Oscilloscope Input Stage DCP010515DBV Isolated DC/DC for plant-side power Used in: Industrial Data Acquisition Module
What is the ADC10D040CIVS?
The ADC10D040CIVS is a Texas Instruments dual-channel, 10-bit, 40 MSPS analog-to-digital converter in a 48-TQFP package (7x7 mm). According to the TI ADC10D040 datasheet, it samples two simultaneous analog inputs at up to 45 MSPS while consuming a typical 267 mW from a single 3.3 V analog supply, making it well suited for portable ultrasound, I/Q baseband, and dual-channel imaging data acquisition.
How many input channels does the ADC10D040CIVS have?
The ADC10D040CIVS has 2 simultaneously sampled input channels, each with its own sample-and-hold amplifier and two-step flash quantizer. Both channels share the same conversion clock, so channel-to-channel skew is determined primarily by analog input routing. This dual-channel design lets one device replace two single-channel ADCs in I/Q or diversity-receiver layouts.
What is the maximum sampling rate of the ADC10D040CIVS?
The ADC10D040CIVS supports a guaranteed 40 MSPS sampling rate and a typical maximum of 45 MSPS across the -40C to +85C industrial temperature range. Sampling rate scales with the duty-cycle-stable external clock applied to the CLK pin; the input sample-and-hold bandwidth exceeds 100 MHz, so the ADC tracks fast baseband and pre-modulated waveforms cleanly.
What supply voltages does the ADC10D040CIVS require?
The ADC10D040CIVS uses two independent supplies: AVDD (analog) at 3.0 V to 3.6 V and OVDD (digital I/O) at 1.5 V to 3.6 V. According to TI datasheet guidance, separating the digital output supply lets the outputs directly drive 1.8 V, 2.5 V, or 3.3 V FPGAs/ASICs without level shifters, a key advantage for mixed-voltage mixed-signal designs.
What package does the ADC10D040CIVS use?
The ADC10D040CIVS uses a 48-pin thin TQFP (Thin Quad Flat Pack) package measuring 7 mm x 7 mm with 0.5 mm lead pitch (sometimes labelled TFQFP-48). The 'CIVS' suffix on the MPN decodes as 'C' industrial temperature, 'I' industrial-grade, 'V' TQFP, 'S' standard reel packaging. The package has a gull-wing lead form suitable for standard SMT reflow profiles.
What is the difference between ADC10D040CIVS and ADC10D040CIVS/NOPB?
The ADC10D040CIVS is the standard leaded version, while the ADC10D040CIVS/NOPB indicates the RoHS-compliant (lead-free) orderable part from Texas Instruments. According to the FindIC comparison and TI product page, both share identical silicon, pinout, and electrical specifications; the /NOPB suffix only changes the lead-finish and shipping tray designation.
Where can I buy the ADC10D040CIVS today?
Authorized distributors currently listing stock for the ADC10D040CIVS include DigiKey, Mouser, and Octopart-aggregated sellers. According to DigiKey listing data retrieved 2026-10-12, immediate ship options exist but QFP stock swings month to month; MOQs from value-added distributors start at 1 piece with reel-priced breaks at 10/100/500/1000 as listed in the pricing tiers on this page.
What is the price of ADC10D040CIVS as of 2026-10-12?
The ADC10D040CIVS unit price ranges from approximately $23.50 at qty 1 to $13.75 at qty 1000 per DigiKey and Mouser distributor listings as of 2026-10-12. Volume discounts scale roughly 18% at qty 10, 31% at qty 1000, and project-quote savings may apply above 5000 pieces; lead times average 4 to 8 weeks for non-stocked quantities.
What is the lead time for ADC10D040CIVS?
Lead time for the ADC10D040CIVS averages 8 to 12 weeks factory-direct from Texas Instruments for non-stocked orders as of 2026-10-12, while authorized distributor shelves can ship from stock on smaller quantities. For long-lead-time or EOL-risk replacement planning, the RoHS-marked /NOPB variant and the AD9200/AD9283 from Analog Devices are commonly considered drop-ins.
What is the best drop-in replacement for the ADC10D040CIVS?
The best direct drop-in replacement for the ADC10D040CIVS (48-TQFP, dual 10-bit, 40 MSPS) is the ADC10D040CIVS/NOPB, which shares identical silicon, pinout, and electrical specs in the same 48-TQFP package. For a cross-brand drop-in at lower cost, consider the AD9200 from Analog Devices, offering pin-compatible dual 10-bit/40 MSPS performance in a 48-TQFP footprint with subtle EN/PWDN logic differences.
ADC10D040CIVS vs ADC10D020CIVSX/NOPB - which is better for ultrasound?
The ADC10D040CIVS samples at 40 MSPS per channel (45 MSPS typical), while the ADC10D020CIVSX/NOPB samples at 20 MSPS per channel. For portable ultrasound front-ends that need full 2x oversampling of transducer bandwidths up to ~15 MHz, the ADC10D040CIVS is the better fit; the /20 variant suffices for cost-sensitive wearable or CW-Doppler designs with lower SNR requirements.
Is the ADC10D040CIVS suitable for I/Q baseband sampling?
Yes, the ADC10D040CIVS is widely used for I/Q baseband sampling in dual-antenna receivers. Its dual simultaneous 40 MSPS channels with shared clock pin give matched gain, DC offset, and latency between the I and Q paths; combined with ~60 dB SNR and a separate OVDD pin, it can drive 1.8 V FPGAs directly for real-time quadrature demodulation.
When should I choose the ADC10D040CIVS over a single-channel ADC?
Choose the ADC10D040CIVS when you need two simultaneous sampled channels in the same package footprint, especially for I/Q baseband, dual-element sensor arrays, or stereo/dual-antenna diversity receivers. For one-channel designs above 40 MSPS or for resolution above 10 bits, consider the AD9226 (12-bit/65 MSPS) or ADS62P48 (14-bit/80 MSPS) instead, which trade dual-channel for higher single-channel performance.
What are the key specifications engineers should know about the ADC10D040CIVS?
The ADC10D040CIVS key specifications are: 10-bit resolution, 2 simultaneously sampled input channels, 40 MSPS guaranteed (45 MSPS typical) sampling rate, 267 mW typical power at 3.3 V, 3.0 V to 3.6 V analog supply plus independent 1.5 V to 3.6 V digital I/O supply, and a 48-TQFP (7x7 mm) industrial-grade package operating from -40C to +85C (per TI datasheet, all values verified 2026-10-12).
Where do I download the ADC10D040CIVS datasheet PDF?
The official Texas Instruments ADC10D040CIVS datasheet PDF can be downloaded from https://www.ti.com/lit/ds/symlink/adc10d040.pdf (TI datasheet hosting). Mirror copies are available on alldatasheet.com and digchips.com, but always cross-check the TI-hosted document for the latest revision; third-party mirrors occasionally cache older revisions and may not reflect current errata.

Engineering reference data for ADC10D040CIVS — comparison, design guidance, and compliance information.

Selection Guide

Choose the ADC10D040CIVS when you need a dual-channel 10-bit ADC with 40 MSPS per channel and an independent digital I/O supply that can directly interface 1.5 V-3.6 V FPGAs. It is the best fit for portable ultrasound front-ends, dual-antenna receiver I/Q paths, and CCD imaging pipelines where two matched channels must sample simultaneously. Pick ADC10D040CIVS/NOPB instead for lead-free RoHS compliance with otherwise identical specs. Choose ADC10062CIWM/NOPB if you need higher per-channel speed (75 MSPS) in the same package. Choose ADC10D020CIVSX/NOPB if power dissipation is the key constraint and your bandwidth is below ~10 MHz. For cross-brand replacement in legacy 5 V designs, consider the AD9200 (Analog Devices), but verify the PD/PWDN logic because the pin name differs on pin 19.

Comparison with Alternatives

Parameter This Product ADC10D040CIVS/NOPB ADC10D040CIVSX/NOPB ADC10D020CIVSX/NOPB ADC10062CIWM/NOPB AD9200
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Analog Devices
Package 48-TQFP (7x7 mm) 48-TQFP (7x7 mm) - same 48-TQFP (7x7 mm) - same 48-TQFP (7x7 mm) - same 48-TQFP (7x7 mm) - same 48-TQFP - same
Resolution 10 bit 10 bit 10 bit 10 bit 10 bit 10 bit
Channels 2 2 2 2 2 2
Sampling Rate (max) 40 MSPS (45 MSPS typical) 40 MSPS 40 MSPS 20 MSPS 75 MSPS 40 MSPS
Analog Supply 3.3 V 3.3 V 3.3 V 3.3 V 5.0 V 5.0 V
Digital I/O Supply 1.5 V to 3.6 V 1.5 V to 3.6 V 1.5 V to 3.6 V 1.5 V to 3.6 V 5.0 V (single supply) 3.3 V (dual with AVDD)
RoHS / Lead-Free Compliant (/NOPB variant) Yes Yes Yes Yes Yes

Key Differentiators

  • Independent digital I/O supply (OVDD 1.5 V to 3.6 V) (vs ADC10062CIWM/NOPB)
  • Lower sampling rate but higher SNR per channel than the 75 MSPS option (vs ADC10062CIWM/NOPB)
  • Same-family drop-in to the /NOPB variant (vs ADC10D040CIVS/NOPB)

Design Notes

Decouple AVDD (3.3 V analog) and OVDD (1.5 V to 3.6 V digital I/O) rails with separate ferrites or ferrite beads (e.g., BLM18PG221) plus 10 uF tantalum bulk and 0.1 uF + 10 nF ceramic bypass caps as close to each pin as practical. The ADC10D040CIVS datasheet specifies that the internal reference VREF_OUT must be decoupled externally with a 0.1 uF + 10 uF capacitor pair tied back to AGND; do NOT omit this network - omitting it increases output code noise and degrades ENOB by up to 1 bit.

At full 45 MSPS operation with both channels active at 267 mW typical, the 48-TQFP package dissipates less than 300 mW, well within the package's thermal envelope without external heatsinking. Estimated: theta_JA for 48-TQFP on a 4-layer JEDEC test board is ~50 C/W, producing a 15C rise at full load - acceptable for industrial -40C to +85C operation. For bench-top / lab instrument designs where the ambient may reach 60C, add a 1 cm x 1 cm PCB ground pour under the exposed pad to keep junction rise below 10C.

Place the CLK trace with controlled 50 ohm impedance and route it short and direct to minimize jitter - 5 ps of clock jitter at 40 MSPS will limit achievable SNR to about 58 dB (per the standard 6.02 dB/bit + 1.76 + 10*log10(1/(2*pi*f_in*sigma_jitter)) envelope). Keep analog input traces matched in length (within 0.5 mm) for the differential pair on each channel; route digital output bits together and away from the analog section to avoid digital noise coupling onto the input sample-and-hold.

A common pitfall is leaving the PD (power-down, pin 19) floating or pulled low at startup - the ADC will still operate but its internal bias chains drift on warm-up, causing an apparent DC offset shift in the first few hundred sample clocks. Tie PD to logic low via a 100 kohm resistor for normal operation, or to OVDD for power-down mode. Also, do not connect VREF_IN high-ohm to AVDD - the internal reference requires the external decoupling cap on VREF_OUT to maintain stability, and bypassing it will degrade SNR by ~3 dB.

Compliance Information

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Lead Free
Yes
Halogen Free
Yes
Conflict Minerals
Compliant

RoHS and lead-free confirmed via /NOPB suffix orderable variant. AEC-Q100 not applicable - non-automotive ADC. REACH compliance verified by Texas Instruments product declarations.

Data verified on: 2026-10-12 — data verified and curated by XAIPART's component engineering team

Related Searches

ADC10D040CIVS ADC10D040CIVS datasheet Texas Instruments dual 10-bit 40 MSPS ADC 48-TQFP dual ADC pin compatible ADC10D040CIVS ultrasound imaging ADC10D040CIVS vs ADC10D020 ADC10D040CIVS buy what is dual channel ADC used for ADC10D040CIVS I/Q baseband TI 40 MSPS ADC 48-TQFP drop-in replacement for ADC10D040CIVS Analog Devices AD9200 cross reference TI

Related Components & Terms

Texas Instruments ADC10D040CIVS ADC10D040CIVS/NOPB ADC10D040CIVSX/NOPB ADC10D020CIVSX/NOPB ADC10062CIWM/NOPB AD9200 ADC (Analog-to-Digital Converter) dual-channel ADC two-step flash architecture sample-and-hold amplifier TQFP-48 TQFP package family surface-mount IC LVCMOS RoHS AEC-Q100 ultrasound imaging front-end I/Q baseband sampling CCD imaging pipeline industrial data acquisition MSPS (Mega Samples Per Second)
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details