An analog multiplexer is a semiconductor switch that routes one of several analog inputs to a shared output. The MAX306/MAX307 family belongs to the analog switch and multiplexer hierarchy within interface ICs and data-conversion systems. Two independent 8:1 sections support simultaneous signal routing, allowing control or measurement systems to share converters, amplifiers, instrumentation amplifiers, and other limited analog resources.
Key electrical characteristics include an on-resistance of less than 100 ohms, channel-to-channel on-resistance matching within 5 ohms, and a maximum on-resistance variation of 7 ohms across the specified analog signal range. Off leakage is less than 2.5 nA at +85 °C, while transition time is less than 250 ns. These characteristics help preserve signal integrity when the multiplexer handles moderate-voltage, low-leakage analog signals.
The monolithic CMOS implementation places matched switching elements on one die, improving resistance matching and keeping channel behavior consistent across the analog operating range. Low off leakage limits unintended coupling through unselected channels, while fast transitions support measurement systems that must settle quickly after changing the selected input. Designers should still allow time for the switched node and following high-impedance circuitry to settle before taking a measurement.
Typical uses include multiplexed data acquisition, sensor and transducer selection, automated test equipment, sample-and-hold systems, and industrial control modules. The device is especially useful where a system must select among multiple analog channels but cannot provide a dedicated front end for every channel. Its 5 V-to-30 V supply range also supports higher-voltage instrumentation than low-voltage-only multiplexers.
For robust PCB design, place the multiplexer close to the analog source or shared converter, keep analog traces short, and provide a low-impedance return path. Check absolute maximum input and output voltages, supply sequencing, and input capacitance against the system limits. Use the manufacturer pin-description table to assign control and enable signals because a complete numbered pinout is not reproduced on this page.
This page consolidates the key electrical characteristics, package details, application guidance, verified lifecycle information, and replacement-search results for engineers evaluating the MAX307EQI+ analog multiplexer.
Drop-in alternatives for MAX307EQI+ — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
No drop-in alternatives available for this product.
Request AlternativesMAX307EQI+ Specifications
| Product Type | Precision CMOS analog multiplexer |
| Multiplexer Configuration | Dual 8:1 / 16 channels |
| Number of Circuits | 2 circuits |
| On-Resistance | Less than 100 ohm |
| On-Resistance Matching Between Channels | Within 5 ohm |
| Maximum On-Resistance Variation | 7 ohm |
| Off Leakage Current | Less than 2.5 nA at +85 °C |
| Transition Time | Less than 250 ns |
| Supply Voltage Range | 5 V to 30 V |
| Package | 28-pin PLCC, 11.5 mm × 11.5 mm |
| Package Pin Count | 28 pins |
| Mounting Type | Surface mount |
| RoHS Status | Compliant |
| Factory Pack Quantity | 39 units |
MAX307EQI+ 28 pins Pin Configuration Guide
Pin configuration for MAX307EQI+ (28 pins package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.
No detailed pinout data available for MAX307EQI+.
Refer to the datasheet for full pin configuration.
Typical Applications
MAX307EQI+ is suitable for 6 applications: Multiplexed Data Acquisition, Industrial Sensor Signal Selection, Automated Test Equipment, Sample-and-Hold Signal Routing, Communication Signal Routing, Precision Measurement Front Ends.
Multiplexed Data Acquisition
The MAX307EQI+ is appropriate for data-acquisition front ends that must select several analog inputs while sharing a converter or instrumentation amplifier. Its two independent 8:1 sections provide 16 selectable channels in one 28-pin PLCC package, while on-resistance below 100 ohms helps limit loading of moderately impedance sources. Transition time below 250 ns supports rapid channel changes, but the acquisition system should still include a settling interval before sampling. Off leakage below 2.5 nA at +85 °C limits coupling through inactive channels, which is valuable when measuring small sensor outputs. Place the mux near the shared converter to minimize trace capacitance and sensitivity to noise.
Recommended
Industrial Sensor Signal Selection
The MAX307EQI+ can route pressure, temperature, position, and other analog sensor outputs into a shared signal-conditioning channel. Its resistance matching within 5 ohms helps reduce gain-dependent channel variation, while maximum on-resistance variation of 7 ohms preserves consistency across the specified analog range. The low off leakage of less than 2.5 nA at +85 °C is particularly useful for high-impedance sensors whose leakage could otherwise create measurement errors. Engineers should calculate the sensor’s effective source impedance, amplifier bias current, and settling time together so that the mux does not determine the accuracy of the final measurement.
Recommended
Automated Test Equipment
The MAX307EQI+ is useful in automated test systems that route a shared excitation or measurement channel among multiple DUT pins. Its dual 8:1 organization reduces the number of separate analog switching sections required, and transition time below 250 ns allows the system to change selections rapidly. The device’s on-resistance below 100 ohms and matching within 5 ohms help maintain channel-to-channel measurement consistency. Test engineers should account for relay or switch capacitance, cable loading, and fixture settling after each selection. Logic thresholds, supply sequencing, and input overvoltage behavior must also be verified against the specific test-board voltage range.
Recommended
Sample-and-Hold Signal Routing
The MAX307EQI+ can select among multiple source signals for a shared sample-and-hold amplifier or downstream converter. Fast transition time below 250 ns reduces the interval during which the acquisition circuit waits for the new channel, while matched on-resistance helps preserve consistent gain between selections. Leakage below 2.5 nA at +85 °C is useful when the held node has high impedance and long acquisition intervals. Layout is critical: keep the selected node short, connect the hold capacitor’s return to a quiet ground path, and use the manufacturer’s recommended bypass arrangement. Designers must also verify that external capacitance does not push settling time beyond the system sampling interval.
Recommended
Communication Signal Routing
The MAX307EQI+ can serve as an analog routing element in communication modules that must select among conditioned signal paths. The dual 8-channel architecture provides flexible routing in a single package, while the 5 V-to-30 V operating range supports industrial interfaces with a higher supply level than typical low-voltage multiplexers. On-resistance matching within 5 ohms limits path-dependent attenuation when the switch is used in series with a high-impedance signal chain. Designers should check bandwidth, charge injection, off-state isolation, and allowed analog input amplitude in the manufacturer data sheet, because the basic multiplexing function alone does not guarantee suitability for high-speed or high-isolation communication paths.
Recommended
Precision Measurement Front Ends
The MAX307EQI+ is suitable for precision measurement front ends that compare multiple low-level analog inputs using shared instrumentation. Its sub-100-ohm on resistance, 5-ohm channel matching, and low off leakage support predictable signal transfer, while the fast transition time permits efficient selection among channels. For highest accuracy, the source impedance must remain low enough for the switch and amplifier combination, and the amplifier input capacitance must be included in settling analysis. Place the device close to the instrumentation amplifier, route control lines away from sensitive analog nodes, and verify that the 5 V-to-30 V supply condition matches the board architecture.
Recommended
Recommended Products Summary
Engineering reference data for MAX307EQI+ — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product |
|---|---|
| Multiplexer Configuration | Dual 8:1 / 16 channels |
| Number of Circuits | 2 circuits |
| On-Resistance | Less than 100 ohm |
| On-Resistance Matching | Within 5 ohm |
| Maximum On-Resistance Variation | 7 ohm |
| Off Leakage | Less than 2.5 nA at +85 °C |
| Transition Time | Less than 250 ns |
| Supply Voltage Range | 5 V to 30 V |
| Package | 28-pin PLCC, 11.5 mm × 11.5 mm |
| Brand | Analog Devices |
Key Differentiators
- Two independent 8:1 analog switching sections in one package (vs MAX306CPI+)
- Low and closely matched channel resistance (vs MAX306CPI+)
- Fast channel transition with low off leakage (vs MAX307EUI+T)
Design Notes
Place the MAX307EQI+ close to the shared analog destination and keep selected and unselected analog nodes short. The manufacturer specifies on-resistance below 100 ohms, but the practical bandwidth also depends on source impedance, load capacitance, connector capacitance, and trace capacitance. Include the external capacitance in settling calculations and allow the acquisition amplifier to recover before the next conversion.
Route digital select and enable traces away from high-impedance analog inputs, and connect the analog ground return directly to the device ground pins with a low-impedance path. Use the manufacturer bypass recommendations and minimize loop area around the supply connections. For long traces or cables between the multiplexer and sensors, add protection and shielding because the 5 V-to-30 V supply rating does not imply that every analog signal may be driven to 30 V.
Do not treat MAX306 or MAX307 versions in DIP or TSSOP packages as direct replacements for the MAX307EQI+ PLCC footprint. Confirm lead numbering, logic levels, supply limits, analog signal limits, and temperature coverage against the manufacturer data sheet before redesigning a board. In measurement systems, also verify that off leakage below 2.5 nA at +85 °C remains acceptable after accounting for sensor bias current, board contamination, and humidity.
Compliance Information