TCAN1051HGDR Overview

The Texas Instruments TCAN1051HGDR is a single-channel, fault-protected CAN FD transceiver supporting data rates up to 5 Mbps in an 8-pin SOIC package. It operates from a 4.5 V to 5.5 V supply, provides one CAN driver and one CAN receiver, and is designed for industrial systems requiring fault protection against CAN bus faults. The device also supports flexible data-rate operation for compatibility with both classical CAN and CAN FD communication networks.

A CAN transceiver, also called a CAN bus interface controller interface, converts logic-level TXD and RXD signals into a differential CAN bus waveform and converts received bus activity back into a digital receive signal. Within the interface hierarchy, the TCAN1051HGDR belongs to the CAN transceiver class, which sits above CAN physical-layer transceivers and supports the CAN FD data-rate range. Its fault-protection circuitry helps manage abnormal bus conditions encountered in automotive, industrial, and embedded-control environments.

The TCAN1051HGDR supports a 4.5 V to 5.5 V supply range, data rates through 5 Mbps, and an operating temperature range of -55 °C to +125 °C. The package is the 8-pin SOIC (D) package identified by ordering code HGDR. Its one-driver, one-receiver configuration supports standard CAN bus node requirements without using multiple transceivers for redundant channels.

The HG device designation indicates a fault-protected transceiver with flexible data-rate capability. The verified product listing identifies the TCAN1051HG as a fault-protected CAN transceiver with flexible data-rate, while the Mouser search result describes the related 5 Mbps CAN FD transceiver as having a 70 V fault-protected bus. Fault-protection behavior, dominant-state recessive output, and bus-recessive timing should be confirmed against the manufacturer datasheet for each power state and operating condition.

Typical applications include industrial automation controllers, robot and machine-control nodes, building automation equipment, automotive electronic control units, CAN FD gateways, and embedded instrumentation. A 5 V controller can connect its CAN TXD and RXD signals directly to the transceiver interface, while CANH and CANL connect to the physical bus. System designers must also account for bus termination, common-mode voltage, isolation requirements, and protection-device coordination.

PCB placement is especially important because a CAN interface converts between low-voltage digital signals and a high-energy differential bus. Place the transceiver near the bus connector and protection network, keep the CANH and CANL route as a closely coupled differential pair, provide a solid ground reference, and observe the manufacturer's recommended external components. Do not add unsupported bus-side capacitance that could disturb edge rates or fault detection.

This product overview consolidates the verified ordering information, package details, operating limits, qualification references, replacement options, and engineering guidance for the TCAN1051HGDR. The comparison and design notes also clarify how to evaluate the HGDR ordering code, automotive-grade counterparts, and related TCAN1051 devices before committing a PCB footprint to production.

Drop-in alternatives for TCAN1051HGDR — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with TCAN1051HGDR (same form factor and footprint) — differing in Package, Product Type.

Texas Instruments
Package: SOIC-8 (D), 3.90 mm width
Product Type: Automotive fault-protected CAN FD transceiver
Compare with TCAN1051HGDR →

TCAN1051HGDRQ1

✅ Drop-In
📦 8-pin SOIC (D)
Automotive-qualified Q1 ordering option versus the standard HGDR; verified data does not state a numerical electrical difference from the standard part.

📋 Reference alternative (not in catalog)

TCAN1051GDR

✅ Drop-In
📦 8-pin SOIC (D)
Related G-series fault-protected CAN transceiver; fault-protection and register details must be checked because the verified results do not quantify all differences from HG.

📋 Reference alternative (not in catalog)

TCAN1051GDRQ1

✅ Drop-In
📦 8-pin SOIC (D)
Automotive-qualified G-series option with the same 8-SOIC format; detailed HG-versus-G electrical differences are not quantified in the substitution results.

📋 Reference alternative (not in catalog)

TCAN1051GVDRQ1

✅ Drop-In
Texas Instruments
📦 8-pin SOIC (D)
Automotive fault-protected CAN FD transceiver · Up to 5 Mbps (CAN FD) · 4.5 V to 5.5 V · 3.3 V to 5 V (VIO-capable variant) · CAN 2.0A/B and CAN FD · 1 · 1 · Half duplex

Contact for price

View Datasheet →

TCAN1051HGDR Specifications

Product Type Fault-protected CAN FD transceiver
CAN Channel Count 1 channel
Maximum Data Rate 5 Mbps
Supply Voltage Range 4.5 V to 5.5 V
Driver Count 1 driver
Receiver Count 1 receiver
Fault-Protected Bus Voltage 70 V
Operating Temperature Range -55 °C to +125 °C
Package 8-pin SOIC (D)
Package Width 3.90 mm
Mounting Type Surface mount
Order Code HGDR
RoHS Status Compliant

TCAN1051HGDR 3.90 mm Pin Configuration Guide

Pin configuration for TCAN1051HGDR (3.90 mm package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.

3.90 mm package pinout diagram for TCAN1051HGDR

No detailed pinout data available for TCAN1051HGDR.

Refer to the datasheet for full pin configuration.

Typical Applications

TCAN1051HGDR is suitable for 6 applications: Industrial Automation Controller, CAN FD Gateway, Robotic Control Module, Building Automation Node, Automotive Electronic Control Unit, Embedded CAN FD Test Equipment.

🏭

Industrial Automation Controller

The TCAN1051HGDR fits an industrial automation node that connects a 5 V controller to a CAN FD field bus. Its 4.5 V to 5.5 V operating range and 5 Mbps data-rate capability provide a practical interface for machinery coordination, remote I/O, and production-cell controllers. The 8-pin SOIC package simplifies routing in mixed-signal control boards, while the 70 V fault-protected bus capability strengthens robustness against bus abuse. Design the PCB with a short differential CANH/CANL route, termination at appropriate bus endpoints, surge protection, and a continuous ground reference. Verify logic levels, bus timing, and fault recovery against the manufacturer datasheet.

🌐

CAN FD Gateway

The TCAN1051HGDR can serve as the physical CAN interface in a gateway that bridges a CAN FD network to Ethernet, serial, or another embedded domain. A 5 Mbps maximum rate supports high-throughput industrial data transfer, while one driver and one receiver provide the required bus node functions. The fault-protected design is useful in installations where cable faults, shorts, or exposed wiring may occur. Place the transceiver near the connector and external protection devices, and route CANH and CANL as a coupled differential pair. Confirm termination strategy, transceiver loop-delay requirements, and network topology for the exact baud rate and cable length.

🤖

Robotic Control Module

The TCAN1051HGDR is appropriate for robot controller modules coordinating axes, sensors, safety peripherals, and remote actuators over a CAN network. Its 5 Mbps capability allows communication to remain responsive as the number of nodes and control messages increases, while the -55 °C to +125 °C range supports demanding industrial environments. The device isolates the controller's digital interface from the physical differential bus and adds fault-protection characteristics suited to long wiring runs. Use a solid return path, protect the connector with appropriately coordinated surge components, and validate bus timing and termination for the robot's cable lengths.

🏠

Building Automation Node

The TCAN1051HGDR can connect building controllers, sensors, HVAC equipment, and access-control panels through a CAN-based building network. The 4.5 V to 5.5 V supply range suits 5 V embedded controllers, and the 5 Mbps rate provides ample bandwidth for sensor updates and actuator commands. Fault protection is particularly valuable where field wiring may be subject to installation errors or induced transients. Keep the CAN route away from high-current switching nodes, provide a low-impedance ground reference, and use the manufacturer-recommended interface components. Verify that the system controller supports the transceiver's idle, dominant, and fault-recovery behavior.

🚗

Automotive Electronic Control Unit

The TCAN1051HGDR provides a 5 Mbps CAN FD interface for an electronic control unit that connects sensors, actuators, and body modules over a differential CAN network. The device's 70 V fault-protected bus characteristic and broad -55 °C to +125 °C operating range align with harsh vehicle environments, while the 8-pin SOIC format supports conventional leaded PCB assembly. Automotive programs should use the corresponding qualified ordering option when required and evaluate transient immunity, bus loading, sleep behavior, and ISO 11898 timing against the complete system specification.

🖥️

Embedded CAN FD Test Equipment

The TCAN1051HGDR is suitable for portable diagnostic and test equipment that communicates with CAN FD nodes at rates through 5 Mbps. Its single-channel 8-SOIC implementation keeps the interface compact while the 4.5 V to 5.5 V operating range supports integration with a 5 V embedded controller. Fault-protected operation can improve bench reliability when the device is connected to partially installed or improperly terminated systems. Add accessible test points for CANH, CANL, TXD, and RXD, provide optional bus termination, and validate isolation or common-mode requirements when connecting the equipment to external harnesses.

Recommended Products Summary

TCAN1051HGDRQ1 Automotive-qualified family alternative for robustness-focused programs Used in: Industrial Automation Controller, CAN FD Gateway, Robotic Control Module, Automotive Electronic Control Unit, Embedded CAN FD Test Equipment TCAN1051GDR Related Texas Instruments CAN transceiver family member Used in: Industrial Automation Controller, Robotic Control Module, Building Automation Node, Embedded CAN FD Test Equipment TCAN1051GDRQ1 Related same-package qualified CAN interface Used in: CAN FD Gateway, Building Automation Node TCAN1051GVDRQ1 Texas Instruments Used in: Automotive Electronic Control Unit
What is the TCAN1051HGDR?
The TCAN1051HGDR is a Texas Instruments fault-protected CAN FD transceiver that supports data rates up to 5 Mbps in an 8-pin SOIC package. According to the Texas Instruments TCAN1051HG product page, the device provides a single CAN channel with flexible data-rate operation and is intended for systems requiring protection against CAN bus faults.
What is the operating voltage of TCAN1051HGDR?
The TCAN1051HGDR operates from a 4.5 V to 5.5 V supply. The Mouser product listing for the 5 Mbps CAN FD transceiver states that supply voltage range directly, while the Texas Instruments product page identifies the TCAN1051HG family as a fault-protected flexible-data-rate transceiver.
How fast can TCAN1051HGDR communicate on a CAN bus?
The TCAN1051HGDR supports CAN communication at rates up to 5 Mbps. Texas Instruments describes the TCAN1051HG family as supporting flexible data rates, and the Mouser listing identifies this device as a 5 Mbps high-speed CAN FD transceiver with one driver and one receiver.
What is the best drop-in replacement for TCAN1051HGDR?
The TCAN1051HGDRQ1 is the closest same-package replacement identified by the cross-reference results because it retains the 8-pin SOIC format and adds automotive qualification. Before substitution, confirm operating temperature, automotive qualification requirements, supply limits, and all transceiver parameters against the Texas Instruments datasheets for both ordering codes.
Can TCAN1051HGDRQ1 replace TCAN1051HGDR?
The TCAN1051HGDRQ1 can serve as an automotive-oriented same-package alternative to TCAN1051HGDR in designs that satisfy the Q1 qualification requirements. The cross-reference results list the Q1 device as an 8-SOIC part, but qualification and production requirements must be verified against the manufacturer ordering information before substitution.
Where can I download the TCAN1051HGDR datasheet PDF?
The official TCAN1051HG datasheet and ordering information are available from the Texas Instruments product page at https://www.ti.com/product/TCAN1051HG. The manufacturer also provides the exact TCAN1051HGDR part details at https://www.ti.com/product/TCAN1051HG/part-details/TCAN1051HGDR, which is the preferred source for pin assignments and electrical characteristics.
Where can I find the TCAN1051HGDR pinout?
Use the pin-description table in the Texas Instruments TCAN1051HG datasheet to assign the eight SOIC pins. The verified product results confirm that TCAN1051HGDR uses an 8-pin SOIC (D) package, but they do not reproduce a complete numbered pin table, so no pin numbers or signal names should be inferred from the ordering code alone.
TCAN1051HGDR vs TCAN1051HGDRQ1: which is better for automotive use?
The TCAN1051HGDRQ1 is the better choice for a design that specifically requires an automotive-qualified option. The TCAN1051HGDR is the standard TCAN1051HG ordering code, whereas the Q1 variant is identified in cross-reference results as an automotive CAN interface IC. Both use the 8-SOIC format, but qualification requirements should be confirmed before any replacement.
When should I choose TCAN1051HGDR instead of TCAN1051HGDRQ1?
Choose the standard TCAN1051HGDR for industrial or general-purpose equipment that does not require the automotive qualification associated with the Q1 option. Choose TCAN1051HGDRQ1 when the end application imposes automotive qualification requirements. Both candidates use the 8-pin SOIC package, but qualification, lifecycle, and sourcing requirements should guide the final choice.
Is TCAN1051HGDR suitable for industrial CAN FD equipment?
The TCAN1051HGDR is suitable for industrial CAN FD equipment requiring a 4.5 V to 5.5 V supply, operation up to 5 Mbps, and a -55 °C to +125 °C temperature range. Its fault-protected CAN interface is appropriate for machinery, automation, and distributed-control networks, provided the bus topology, termination, protection, and grounding meet system requirements.
What can replace TCAN1051HGDR?
The clearest same-package replacement identified for TCAN1051HGDR is TCAN1051HGDRQ1, which retains the 8-SOIC format and adds an automotive-grade ordering option. Other TCAN1051 family members may differ in pin 5 behavior or qualification, so engineers should treat TCAN1042HGVDRBRQ1 and TCAN1051HGV as functionally related options rather than automatic drop-in replacements.
Is TCAN1051HGDR the same as TCAN1051HGD?
The TCAN1051HGDR and TCAN1051HGD refer to the same underlying TCAN1051HG device in different ordering-code formats. The HGDR code identifies the 8-pin SOIC package with a reel-oriented ordering suffix, while HGD is used in a separate comparison listing. Package suffix decoding and the manufacturer ordering table should be used for production purchasing.
What are the key specifications of TCAN1051HGDR that engineers should know?
The key TCAN1051HGDR specifications are a 4.5 V to 5.5 V operating supply, up to 5 Mbps CAN FD data rate, one driver, one receiver, 70 V fault-protected bus capability, and a -55 °C to +125 °C operating-temperature range. The device is packaged as an 8-pin SOIC (D), making its footprint and environmental requirements central to design review.
What is the best NXP equivalent for TCAN1051HGDR?
No verified NXP equivalent for the TCAN1051HGDR was identified in the available substitution results, so an NXP cross-brand drop-in cannot be recommended responsibly. The documented alternatives are from Texas Instruments. A valid NXP replacement must use the same 8-pin SOIC footprint, preserve the pin functions, and remain within the required supply, data-rate, fault-protection, and temperature limits.
Where can I buy TCAN1051HGDR and check current lead time?
Use the Request a Quote form on this XAIPART page to request the current TCAN1051HGDR price, stock position, minimum order quantity, and lead time. The available distributor search results show market listings, but changing commercial terms should be confirmed through the quote form rather than treated as a fixed quotation.

Engineering reference data for TCAN1051HGDR — comparison, design guidance, and compliance information.

Selection Guide

Choose the TCAN1051HGDR for a 5 V industrial or embedded CAN FD node that needs one fault-protected bus interface, operation up to 5 Mbps, and an 8-pin SOIC footprint. Select TCAN1051HGDRQ1 when the same electrical configuration is needed with an automotive-qualified ordering option. TCAN1051GDR is appropriate only after its register, pin, and fault-protection behavior has been checked against the HG device. Use TCAN1051GDRQ1 when a qualified G-series configuration is required. TCAN1051GVDRQ1 requires special attention because the V-series ordering option uses pin 5 as VIO, while the HG schematic may leave pin 5 unconnected. No verified cross-brand drop-in was identified, so changing manufacturers requires a new footprint, pin-function, timing, and protection review rather than a simple substitution.

Comparison with Alternatives

Parameter This Product TCAN1051HGDRQ1 TCAN1051GDR TCAN1051GDRQ1 TCAN1051GVDRQ1
Package 8-pin SOIC (D) 8-pin SOIC (D) 8-pin SOIC (D) 8-pin SOIC (D) 8-pin SOIC (D)
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Product Class Fault-protected CAN FD transceiver Fault-protected CAN transceiver CAN transceiver Automotive CAN interface IC Fault-protected CAN transceiver
Automotive Qualification Option Standard HG ordering code Q1 option Standard G ordering code Q1 option Q1 option

Key Differentiators

  • Direct Q1 qualification alternative for automotive programs (vs TCAN1051HGDRQ1)
  • Higher maximum data rate than classical-CAN-focused implementations (vs TCAN1051GDR)
  • Broad operating-temperature coverage for industrial equipment (vs TCAN1051GDRQ1)

Design Notes

Place the TCAN1051HGDR near the CAN connector and external bus-protection components. Route CANH and CANL as a short, coupled differential pair with substantially equal trace lengths, avoid crossing high-current paths, and connect the interface ground to the board's main ground reference through a low-impedance path. Keep the digital TXD and RXD traces away from the bus-side surge devices because their high-voltage transients can couple into controller pins.

Do not assume that every TCAN1051 suffix is electrically interchangeable. Texas Instruments support information notes that V-series devices use pin 5 as VIO, while an HG schematic may show that pin as unconnected. Verify the numbered pin table, VIO behavior, fault-protection thresholds, and recessive-state output for each alternative before replacing the TCAN1051HGDR.

Use a termination strategy appropriate to the complete CAN network rather than placing 120 ohm across every node. Fault-protection devices, split terminations, chassis grounding, and common-mode chokes can change bus impedance and edge behavior. Review the final connector, cable, protection, and transceiver arrangement together so that the 5 Mbps signal quality and CAN FD timing remain within system requirements.

Compliance Information

RoHS
Compliant
REACH
Unknown
AEC-Q100
Unknown
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

The comparison result explicitly identifies the TCAN1051HGDR as RoHS compliant. The standard HGDR ordering code is not established as AEC-Q100 qualified; use the Q1 ordering option when automotive qualification is required. Other environmental and material declarations are unknown.

Related Searches

TCAN1051HGDR datasheet TCAN1051HGDR pinout TCAN1051HGDR datasheet pdf TCAN1051HGDR equivalent TCAN1051HGDR replacement TCAN1051HGDR cross reference TCAN1051HGDR vs TCAN1051HGDRQ1 TCAN1051HGDR price TCAN1051HGDR stock Texas Instruments TCAN1051HGDR TCAN1051HG 8-SOIC pinout TCAN1051HGDR industrial CAN FD

Related Components & Terms

Texas Instruments TCAN1051HGDR TCAN1051HG TCAN1051HGDRQ1 TCAN1051GDR TCAN1051GDRQ1 TCAN1051GVDRQ1 CAN transceiver CAN FD Controller Area Network fault-protected transceiver differential bus interface 8-pin SOIC SOIC package family surface-mount package 5 Mbps 4.5 V to 5.5 V 70 V bus protection -55 °C to +125 °C industrial automation automotive ECU CAN gateway CANH CANL
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details