TCAN1051HGDR - 5Mbps Fault-Protected CAN FD | Texas Instruments
MPN: TCAN1051HGDR ✓ Hoạt độngTCAN1051HGDR Tóm tắt
A CAN transceiver, also called a CAN bus interface controller interface, converts logic-level TXD and RXD signals into a differential CAN bus waveform and converts received bus activity back into a digital receive signal. Within the interface hierarchy, the TCAN1051HGDR belongs to the CAN transceiver class, which sits above CAN physical-layer transceivers and supports the CAN FD data-rate range. Its fault-protection circuitry helps manage abnormal bus conditions encountered in automotive, industrial, and embedded-control environments.
The TCAN1051HGDR supports a 4.5 V to 5.5 V supply range, data rates through 5 Mbps, and an operating temperature range of -55 °C to +125 °C. The package is the 8-pin SOIC (D) package identified by ordering code HGDR. Its one-driver, one-receiver configuration supports standard CAN bus node requirements without using multiple transceivers for redundant channels.
The HG device designation indicates a fault-protected transceiver with flexible data-rate capability. The verified product listing identifies the TCAN1051HG as a fault-protected CAN transceiver with flexible data-rate, while the Mouser search result describes the related 5 Mbps CAN FD transceiver as having a 70 V fault-protected bus. Fault-protection behavior, dominant-state recessive output, and bus-recessive timing should be confirmed against the manufacturer datasheet for each power state and operating condition.
Typical applications include industrial automation controllers, robot and machine-control nodes, building automation equipment, automotive electronic control units, CAN FD gateways, and embedded instrumentation. A 5 V controller can connect its CAN TXD and RXD signals directly to the transceiver interface, while CANH and CANL connect to the physical bus. System designers must also account for bus termination, common-mode voltage, isolation requirements, and protection-device coordination.
PCB placement is especially important because a CAN interface converts between low-voltage digital signals and a high-energy differential bus. Place the transceiver near the bus connector and protection network, keep the CANH and CANL route as a closely coupled differential pair, provide a solid ground reference, and observe the manufacturer's recommended external components. Do not add unsupported bus-side capacitance that could disturb edge rates or fault detection.
This product overview consolidates the verified ordering information, package details, operating limits, qualification references, replacement options, and engineering guidance for the TCAN1051HGDR. The comparison and design notes also clarify how to evaluate the HGDR ordering code, automotive-grade counterparts, and related TCAN1051 devices before committing a PCB footprint to production.
Bộ thay thế dễ dàng lắp đặt cho TCAN1051HGDR — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với TCAN1051HGDR (cùng hình factor và footprint) — khác nhau ở Package, Product Type.
TCAN1051HGDRQ1
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
TCAN1051GDR
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
TCAN1051GDRQ1
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
TCAN1051GVDRQ1
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →TCAN1051HGDR Thông số kỹ thuật
| Product Type | Fault-protected CAN FD transceiver |
| CAN Channel Count | 1 channel |
| Maximum Data Rate | 5 Mbps |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Driver Count | 1 driver |
| Receiver Count | 1 receiver |
| Fault-Protected Bus Voltage | 70 V |
| Khoảng nhiệt độ hoạt động | -55 °C to +125 °C |
| Hộp | 8-pin SOIC (D) |
| Package Width | 3.90 mm |
| Kiểu lắp đặt | Surface mount |
| Order Code | HGDR |
| Trạng thái RoHS | Compliant |
Hướng dẫn cấu hình chân TCAN1051HGDR 3.90 mm
Cấu hình chân cho TCAN1051HGDR (3.90 mm gói). Số thứ tự chân, chức năng và sơ đồ kết nối được xác định trong tài liệu thông số kỹ thuật của nhà sản xuất. Tham khảo nó để biết footprint và hướng dẫn hàn chính xác.
Không có dữ liệu chân cụ thể sẵn có cho TCAN1051HGDR.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
TCAN1051HGDR phù hợp cho 6 Áp dụngs: Industrial Automation Controller, CAN FD Gateway, Robotic Control Module, Building Automation Node, Automotive Electronic Control Unit, Embedded CAN FD Test Equipment.
Industrial Automation Controller
The TCAN1051HGDR fits an industrial automation node that connects a 5 V controller to a CAN FD field bus. Its 4.5 V to 5.5 V operating range and 5 Mbps data-rate capability provide a practical interface for machinery coordination, remote I/O, and production-cell controllers. The 8-pin SOIC package simplifies routing in mixed-signal control boards, while the 70 V fault-protected bus capability strengthens robustness against bus abuse. Design the PCB with a short differential CANH/CANL route, termination at appropriate bus endpoints, surge protection, and a continuous ground reference. Verify logic levels, bus timing, and fault recovery against the manufacturer datasheet.
Được đề xuất
CAN FD Gateway
The TCAN1051HGDR can serve as the physical CAN interface in a gateway that bridges a CAN FD network to Ethernet, serial, or another embedded domain. A 5 Mbps maximum rate supports high-throughput industrial data transfer, while one driver and one receiver provide the required bus node functions. The fault-protected design is useful in installations where cable faults, shorts, or exposed wiring may occur. Place the transceiver near the connector and external protection devices, and route CANH and CANL as a coupled differential pair. Confirm termination strategy, transceiver loop-delay requirements, and network topology for the exact baud rate and cable length.
Được đề xuất
Robotic Control Module
The TCAN1051HGDR is appropriate for robot controller modules coordinating axes, sensors, safety peripherals, and remote actuators over a CAN network. Its 5 Mbps capability allows communication to remain responsive as the number of nodes and control messages increases, while the -55 °C to +125 °C range supports demanding industrial environments. The device isolates the controller's digital interface from the physical differential bus and adds fault-protection characteristics suited to long wiring runs. Use a solid return path, protect the connector with appropriately coordinated surge components, and validate bus timing and termination for the robot's cable lengths.
Được đề xuất
Building Automation Node
The TCAN1051HGDR can connect building controllers, sensors, HVAC equipment, and access-control panels through a CAN-based building network. The 4.5 V to 5.5 V supply range suits 5 V embedded controllers, and the 5 Mbps rate provides ample bandwidth for sensor updates and actuator commands. Fault protection is particularly valuable where field wiring may be subject to installation errors or induced transients. Keep the CAN route away from high-current switching nodes, provide a low-impedance ground reference, and use the manufacturer-recommended interface components. Verify that the system controller supports the transceiver's idle, dominant, and fault-recovery behavior.
Được đề xuất
Automotive Electronic Control Unit
The TCAN1051HGDR provides a 5 Mbps CAN FD interface for an electronic control unit that connects sensors, actuators, and body modules over a differential CAN network. The device's 70 V fault-protected bus characteristic and broad -55 °C to +125 °C operating range align with harsh vehicle environments, while the 8-pin SOIC format supports conventional leaded PCB assembly. Automotive programs should use the corresponding qualified ordering option when required and evaluate transient immunity, bus loading, sleep behavior, and ISO 11898 timing against the complete system specification.
Được đề xuất
Embedded CAN FD Test Equipment
The TCAN1051HGDR is suitable for portable diagnostic and test equipment that communicates with CAN FD nodes at rates through 5 Mbps. Its single-channel 8-SOIC implementation keeps the interface compact while the 4.5 V to 5.5 V operating range supports integration with a 5 V embedded controller. Fault-protected operation can improve bench reliability when the device is connected to partially installed or improperly terminated systems. Add accessible test points for CANH, CANL, TXD, and RXD, provide optional bus termination, and validate isolation or common-mode requirements when connecting the equipment to external harnesses.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho TCAN1051HGDR — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | TCAN1051HGDRQ1 | TCAN1051GDR | TCAN1051GDRQ1 | TCAN1051GVDRQ1 |
|---|---|---|---|---|---|
| Package | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Class | Fault-protected CAN FD transceiver | Fault-protected CAN transceiver | CAN transceiver | Automotive CAN interface IC | Fault-protected CAN transceiver |
| Automotive Qualification Option | Standard HG ordering code | Q1 option | Standard G ordering code | Q1 option | Q1 option |
Bảo phân biệt quan trọng
- Direct Q1 qualification alternative for automotive programs (vsTCAN1051HGDRQ1)
- Higher maximum data rate than classical-CAN-focused implementations (vsTCAN1051GDR)
- Broad operating-temperature coverage for industrial equipment (vsTCAN1051GDRQ1)
Ghi chú thiết kế
Place the TCAN1051HGDR near the CAN connector and external bus-protection components. Route CANH and CANL as a short, coupled differential pair with substantially equal trace lengths, avoid crossing high-current paths, and connect the interface ground to the board's main ground reference through a low-impedance path. Keep the digital TXD and RXD traces away from the bus-side surge devices because their high-voltage transients can couple into controller pins.
Do not assume that every TCAN1051 suffix is electrically interchangeable. Texas Instruments support information notes that V-series devices use pin 5 as VIO, while an HG schematic may show that pin as unconnected. Verify the numbered pin table, VIO behavior, fault-protection thresholds, and recessive-state output for each alternative before replacing the TCAN1051HGDR.
Use a termination strategy appropriate to the complete CAN network rather than placing 120 ohm across every node. Fault-protection devices, split terminations, chassis grounding, and common-mode chokes can change bus impedance and edge behavior. Review the final connector, cable, protection, and transceiver arrangement together so that the 5 Mbps signal quality and CAN FD timing remain within system requirements.
Thông tin tuân thủ
The comparison result explicitly identifies the TCAN1051HGDR as RoHS compliant. The standard HGDR ordering code is not established as AEC-Q100 qualified; use the Q1 ordering option when automotive qualification is required. Other environmental and material declarations are unknown.