TCAN1051HGDR - 5Mbps Fault-Protected CAN FD | Texas Instruments
MPN: TCAN1051HGDR ✓ সক্রিয়TCAN1051HGDR সারাংশ
A CAN transceiver, also called a CAN bus interface controller interface, converts logic-level TXD and RXD signals into a differential CAN bus waveform and converts received bus activity back into a digital receive signal. Within the interface hierarchy, the TCAN1051HGDR belongs to the CAN transceiver class, which sits above CAN physical-layer transceivers and supports the CAN FD data-rate range. Its fault-protection circuitry helps manage abnormal bus conditions encountered in automotive, industrial, and embedded-control environments.
The TCAN1051HGDR supports a 4.5 V to 5.5 V supply range, data rates through 5 Mbps, and an operating temperature range of -55 °C to +125 °C. The package is the 8-pin SOIC (D) package identified by ordering code HGDR. Its one-driver, one-receiver configuration supports standard CAN bus node requirements without using multiple transceivers for redundant channels.
The HG device designation indicates a fault-protected transceiver with flexible data-rate capability. The verified product listing identifies the TCAN1051HG as a fault-protected CAN transceiver with flexible data-rate, while the Mouser search result describes the related 5 Mbps CAN FD transceiver as having a 70 V fault-protected bus. Fault-protection behavior, dominant-state recessive output, and bus-recessive timing should be confirmed against the manufacturer datasheet for each power state and operating condition.
Typical applications include industrial automation controllers, robot and machine-control nodes, building automation equipment, automotive electronic control units, CAN FD gateways, and embedded instrumentation. A 5 V controller can connect its CAN TXD and RXD signals directly to the transceiver interface, while CANH and CANL connect to the physical bus. System designers must also account for bus termination, common-mode voltage, isolation requirements, and protection-device coordination.
PCB placement is especially important because a CAN interface converts between low-voltage digital signals and a high-energy differential bus. Place the transceiver near the bus connector and protection network, keep the CANH and CANL route as a closely coupled differential pair, provide a solid ground reference, and observe the manufacturer's recommended external components. Do not add unsupported bus-side capacitance that could disturb edge rates or fault detection.
This product overview consolidates the verified ordering information, package details, operating limits, qualification references, replacement options, and engineering guidance for the TCAN1051HGDR. The comparison and design notes also clarify how to evaluate the HGDR ordering code, automotive-grade counterparts, and related TCAN1051 devices before committing a PCB footprint to production.
এর জন্য ড্রপ-ইন বিকল্প TCAN1051HGDR — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
এই সিরিজের ভ্যারিয়েন্ট
একই সিরিজের মডেল যেগুলো drop-in compatible TCAN1051HGDR (একই form factor এবং footprint) — পার্থক্য রয়েছে Package, Product Type.
TCAN1051HGDRQ1
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
TCAN1051GDR
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
TCAN1051GDRQ1
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
TCAN1051GVDRQ1
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →TCAN1051HGDR বিশেষণ
| Product Type | Fault-protected CAN FD transceiver |
| CAN Channel Count | 1 channel |
| Maximum Data Rate | 5 Mbps |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Driver Count | 1 driver |
| Receiver Count | 1 receiver |
| Fault-Protected Bus Voltage | 70 V |
| অপারেটিং তাপমাত্রার পরিসর | -55 °C to +125 °C |
| প্যাকেজ | 8-pin SOIC (D) |
| Package Width | 3.90 mm |
| মাউন্টিং টাইপ | Surface mount |
| Order Code | HGDR |
| RoHS স্ট্যাটাস | Compliant |
TCAN1051HGDR 3.90 mm পিন কনফিগারেশন গাইড
TCAN1051HGDR (3.90 mm প্যাকেজ)-এর পিন কনফিগারেশন। পিন নম্বরিং, ফাংশন এবং সংযোগ ডায়াগ্রাম প্রস্তুতকারকের ডেটাশিটে সংজ্ঞায়িত করা আছে। সঠিক ফুটপ্রিন্ট এবং সোল্ডারিং নির্দেশিকার জন্য এটি দেখুন।
এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি TCAN1051HGDR.
দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।
সাধারণ ব্যবহার
TCAN1051HGDR এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Industrial Automation Controller, CAN FD Gateway, Robotic Control Module, Building Automation Node, Automotive Electronic Control Unit, Embedded CAN FD Test Equipment.
Industrial Automation Controller
The TCAN1051HGDR fits an industrial automation node that connects a 5 V controller to a CAN FD field bus. Its 4.5 V to 5.5 V operating range and 5 Mbps data-rate capability provide a practical interface for machinery coordination, remote I/O, and production-cell controllers. The 8-pin SOIC package simplifies routing in mixed-signal control boards, while the 70 V fault-protected bus capability strengthens robustness against bus abuse. Design the PCB with a short differential CANH/CANL route, termination at appropriate bus endpoints, surge protection, and a continuous ground reference. Verify logic levels, bus timing, and fault recovery against the manufacturer datasheet.
সুপারিশকৃত
CAN FD Gateway
The TCAN1051HGDR can serve as the physical CAN interface in a gateway that bridges a CAN FD network to Ethernet, serial, or another embedded domain. A 5 Mbps maximum rate supports high-throughput industrial data transfer, while one driver and one receiver provide the required bus node functions. The fault-protected design is useful in installations where cable faults, shorts, or exposed wiring may occur. Place the transceiver near the connector and external protection devices, and route CANH and CANL as a coupled differential pair. Confirm termination strategy, transceiver loop-delay requirements, and network topology for the exact baud rate and cable length.
সুপারিশকৃত
Robotic Control Module
The TCAN1051HGDR is appropriate for robot controller modules coordinating axes, sensors, safety peripherals, and remote actuators over a CAN network. Its 5 Mbps capability allows communication to remain responsive as the number of nodes and control messages increases, while the -55 °C to +125 °C range supports demanding industrial environments. The device isolates the controller's digital interface from the physical differential bus and adds fault-protection characteristics suited to long wiring runs. Use a solid return path, protect the connector with appropriately coordinated surge components, and validate bus timing and termination for the robot's cable lengths.
সুপারিশকৃত
Building Automation Node
The TCAN1051HGDR can connect building controllers, sensors, HVAC equipment, and access-control panels through a CAN-based building network. The 4.5 V to 5.5 V supply range suits 5 V embedded controllers, and the 5 Mbps rate provides ample bandwidth for sensor updates and actuator commands. Fault protection is particularly valuable where field wiring may be subject to installation errors or induced transients. Keep the CAN route away from high-current switching nodes, provide a low-impedance ground reference, and use the manufacturer-recommended interface components. Verify that the system controller supports the transceiver's idle, dominant, and fault-recovery behavior.
সুপারিশকৃত
Automotive Electronic Control Unit
The TCAN1051HGDR provides a 5 Mbps CAN FD interface for an electronic control unit that connects sensors, actuators, and body modules over a differential CAN network. The device's 70 V fault-protected bus characteristic and broad -55 °C to +125 °C operating range align with harsh vehicle environments, while the 8-pin SOIC format supports conventional leaded PCB assembly. Automotive programs should use the corresponding qualified ordering option when required and evaluate transient immunity, bus loading, sleep behavior, and ISO 11898 timing against the complete system specification.
সুপারিশকৃত
Embedded CAN FD Test Equipment
The TCAN1051HGDR is suitable for portable diagnostic and test equipment that communicates with CAN FD nodes at rates through 5 Mbps. Its single-channel 8-SOIC implementation keeps the interface compact while the 4.5 V to 5.5 V operating range supports integration with a 5 V embedded controller. Fault-protected operation can improve bench reliability when the device is connected to partially installed or improperly terminated systems. Add accessible test points for CANH, CANL, TXD, and RXD, provide optional bus termination, and validate isolation or common-mode requirements when connecting the equipment to external harnesses.
সুপারিশকৃত
সুপারিশকৃত পণ্যের সারসংক্ষেপ
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা TCAN1051HGDR — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য | TCAN1051HGDRQ1 | TCAN1051GDR | TCAN1051GDRQ1 | TCAN1051GVDRQ1 |
|---|---|---|---|---|---|
| Package | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Class | Fault-protected CAN FD transceiver | Fault-protected CAN transceiver | CAN transceiver | Automotive CAN interface IC | Fault-protected CAN transceiver |
| Automotive Qualification Option | Standard HG ordering code | Q1 option | Standard G ordering code | Q1 option | Q1 option |
মূল পার্থক্যসমূহ
- Direct Q1 qualification alternative for automotive programs (বনামTCAN1051HGDRQ1)
- Higher maximum data rate than classical-CAN-focused implementations (বনামTCAN1051GDR)
- Broad operating-temperature coverage for industrial equipment (বনামTCAN1051GDRQ1)
ডিজাইন নোট
Place the TCAN1051HGDR near the CAN connector and external bus-protection components. Route CANH and CANL as a short, coupled differential pair with substantially equal trace lengths, avoid crossing high-current paths, and connect the interface ground to the board's main ground reference through a low-impedance path. Keep the digital TXD and RXD traces away from the bus-side surge devices because their high-voltage transients can couple into controller pins.
Do not assume that every TCAN1051 suffix is electrically interchangeable. Texas Instruments support information notes that V-series devices use pin 5 as VIO, while an HG schematic may show that pin as unconnected. Verify the numbered pin table, VIO behavior, fault-protection thresholds, and recessive-state output for each alternative before replacing the TCAN1051HGDR.
Use a termination strategy appropriate to the complete CAN network rather than placing 120 ohm across every node. Fault-protection devices, split terminations, chassis grounding, and common-mode chokes can change bus impedance and edge behavior. Review the final connector, cable, protection, and transceiver arrangement together so that the 5 Mbps signal quality and CAN FD timing remain within system requirements.
কমপ্লায়েন্স তথ্য
The comparison result explicitly identifies the TCAN1051HGDR as RoHS compliant. The standard HGDR ordering code is not established as AEC-Q100 qualified; use the Q1 ordering option when automotive qualification is required. Other environmental and material declarations are unknown.