AD7874BN - 4-Channel 12-Bit 116 kSPS DAS | Analog Devices
N.º da peça: AD7874BN ✗ Fim de vidaAD7874BN Visão geral
A data acquisition system, or DAS, combines analog sampling, conversion, timing, and digital output functions in one device. The AD7874 belongs to the ADC hierarchy: data acquisition system > analog-to-digital converter > data-conversion IC. Its four-channel simultaneous sampling makes it useful when engineers need synchronized measurements rather than four independent sequential conversions. The parallel output architecture transfers each 12-bit conversion result as digital data lines rather than relying on a serial protocol.
The principal features of the AD7874BN are four simultaneous input channels, 12-bit conversion resolution, a 116 kSPS throughput rate, and an integrated reference and clock. Four track-and-hold amplifiers acquire the inputs simultaneously, while the on-chip reference supports repeatable conversion operation and the reference input/output facility permits several AD7874 devices to use a common reference source. The manufacturer also specifies dynamic performance characteristics such as distortion and signal-to-noise ratio in addition to conventional DC accuracy.
Operationally, the device combines sampling and conversion into a compact data-acquisition block. The track-and-hold stage captures each input before conversion, allowing the four channels to represent the same system state. The 12-bit result provides 4096 quantization intervals across the selected analog input range, while the 116 kSPS figure defines the maximum aggregate conversion rate stated for the device. Because the interface is parallel, system designers must allocate suitable connector and digital-bus resources while ensuring that acquisition timing remains synchronized.
Typical uses include multi-phase power monitoring, industrial instrumentation, vibration and motion analysis, laboratory measurement systems, and acquisition backplanes where several channels must be measured together. Simultaneous sampling is especially valuable when comparing related signals, since it reduces the time offset that would otherwise appear between sequential channel measurements.
A key implementation consideration is signal conditioning. Each source should present an input voltage compatible with the selected input range, remain within the device's analog limits, and have low source impedance where required. Decoupling, grounding, digital-bus timing, and acquisition-trigger implementation should be reviewed against the manufacturer datasheet before a new board is released.
This product record combines the manufacturer functional description with distributor package identification, replacement analysis, application guidance, and design-focused implementation notes. It helps engineers identify the AD7874BN quickly, evaluate whether its simultaneous four-channel architecture matches a measurement task, and verify package and sourcing constraints before committing to a layout or production BOM.
Alternativas drop-in para AD7874BN — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
AD7874BNZ
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
AD7874BN Classificações máximas e características elétricas
| Product Type | 4-channel simultaneous-sampling data acquisition system |
| ADC Resolution | 12 bit |
| Number of Input Channels | 4 channels |
| Sampling Throughput | 116 kSPS |
| Sampling Method | Simultaneous sampling |
| Data Interface | Parallel |
| Integrated ADC | 1 high-speed 12-bit ADC |
| Track-and-Hold Amplifiers | 4 integrated track-and-hold amplifiers |
| Reference | On-chip reference with reference input/output facility |
| Clock | On-chip clock |
| Encapsulamento | 28-pin plastic DIP |
| Package Type | PDIP |
| Tipo de montagem | Through-hole |
| Número de pinos | 28 pins |
| Temperature Grade | Industrial |
Guia de Configuração de Pinos do AD7874BN pdip
Configuração de pinos para AD7874BN (pacote pdip). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.
Nenhum dado detalhado de pinagem disponível para AD7874BN.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
AD7874BN é adequado para 6 aplicaçãos: Multiphase Power Monitoring, Industrial Process Instrumentation, Vibration and Motion Analysis, Laboratory Data-Acquisition Systems, Data Acquisition Backplanes, Medical and Test Instrumentation.
Multiphase Power Monitoring
The AD7874BN fits multichannel power-system measurement because it samples four analog inputs simultaneously rather than sequentially. A designer can assign the channels to phase voltages, phase currents, bus voltage, or a reference signal, and the 116 kSPS throughput provides a shared acquisition cadence for the group. The 12-bit converter provides 4096 quantization levels, while simultaneous track-and-hold acquisition preserves the relationship between phase-related waveforms. Signal scaling, anti-alias filtering, isolation, and common-mode limits remain external design tasks because the AD7874BN does not provide galvanic isolation or programmable gain in the identified specifications.
Industrial Process Instrumentation
The AD7874BN is appropriate for industrial acquisition boards that monitor several related process variables at the same instant, such as pressure, temperature bridge outputs, valve position, and a shared process reference. Four simultaneous channels avoid the timing separation that sequential multiplexing can introduce, which is useful when calculating phase, ratio, or correlation relationships. The 116 kSPS throughput and 12-bit resolution support general-purpose process monitoring, while the on-chip reference and clock reduce external timing complexity. Factory deployments should still account for sensor excitation, grounding, isolation, calibration, and environmental qualification.
Vibration and Motion Analysis
The AD7874BN can support coordinated vibration or motion measurement when several axes or auxiliary reference signals must be sampled together. Simultaneous acquisition gives the four track-and-hold amplifiers a common sampling instant, helping preserve amplitude and phase relationships between channels. The 116 kSPS rate can represent vibration signatures within its specified bandwidth, and the 12-bit result provides a practical balance between resolution and conversion throughput. The designer must select sensor amplifiers and anti-alias filters with suitable bandwidth and noise behavior, maintain low-noise grounding, and verify that the complete signal path does not distort the dynamic range being measured.
Laboratory Data-Acquisition Systems
The AD7874BN is well suited to a laboratory instrument requiring four simultaneous channels and a parallel data path. It can capture a stimulus response, bridge signal, reference channel, and monitor channel in one acquisition frame, which reduces inter-channel timing offsets. The integrated ADC, reference, clock, and track-and-hold circuits provide the core conversion function in a single 28-pin DIP device. The parallel interface makes the part most appropriate for systems with adequate board space and digital routing capacity. Calibration, input conditioning, clock-synchronous acquisition logic, and PC or processor interface logic should be developed around the manufacturer timing diagrams.
Data Acquisition Backplanes
The AD7874BN can be used in a modular acquisition backplane where multiple synchronized channels are distributed through a parallel bus. Because the device converts four inputs simultaneously, each card can capture a related measurement group before presenting the 12-bit results to shared digital logic. The on-chip clock and reference help establish repeatable conversion behavior, although system-level clock distribution and reference routing still require careful design. The 28-pin through-hole package simplifies repair and board-level assembly, but obsolete lifecycle status means the complete backplane should be reviewed for long-term maintenance before new deployment.
Medical and Test Instrumentation
The AD7874BN can serve as the acquisition element in specialized test equipment that measures four related analog nodes in one sampling interval. Its 12-bit resolution and 116 kSPS throughput are useful for low-to-moderate-bandwidth instrumentation, while simultaneous sampling improves comparison of stimulus, response, and reference channels. A medical or diagnostic design would require a separate review of applicable electrical-safety, isolation, leakage, and qualification requirements because those requirements are not established by the AD7874 family description. Signal isolation, patient protection, calibration, and diagnostic accuracy must therefore be implemented and validated at the complete-system level.
Dados de referência de engenharia para AD7874BN — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | AD7874BNZ |
|---|---|---|
| Brand | Analog Devices | Analog Devices |
| Package | 28-pin plastic DIP | 28-pin ceramic DIP |
| Mounting Style | Through-hole | Through-hole |
| Number of Channels | 4 channels | 4 channels |
| Sampling Method | Simultaneous sampling | Simultaneous sampling |
| Resolution | 12 bit | 12 bit |
| Throughput | 116 kSPS | 116 kSPS |
| Data Interface | Parallel | Parallel |
| Integrated Reference | Yes | Yes |
| Integrated Clock | Yes | Yes |
Principais diferenciais
- True four-channel simultaneous acquisition (vs AD7874BNZ)
- Integrated acquisition subsystem (vs AD7874BNZ)
- Distinct package construction for procurement selection (vs AD7874BNZ)
Notas de projeto
Route the four analog inputs as short, well-controlled traces and keep them away from the 12-bit parallel output bus and clock distribution network. Place input filtering and conditioning components close to the associated pins, while providing a quiet return path for analog ground. The four track-and-hold amplifiers capture simultaneously, but unequal trace lengths and mismatched source impedances can still create channel-dependent timing and amplitude errors. Validate the complete layout against the manufacturer application guidance before production.
Design the 116 kSPS parallel data path for settling before the next conversion result is sampled. Account for output timing, external bus capacitance, board skew, and the acquisition clock's relationship to enable or conversion-control signals. Series damping may be required when long routes connect the AD7874BN to system logic. Keep clock and data routes away from sensitive analog inputs and use a low-impedance reference return to minimize conversion-dependent noise.
Do not treat simultaneous sampling as a substitute for correct input conditioning. Confirm each channel's allowable voltage range, source impedance, bandwidth, and overvoltage behavior in the manufacturer datasheet. The 12-bit resolution does not guarantee 12-bit system accuracy if the reference, amplifier, filter, or layout introduces noise and nonlinearity. Preserve unused pins according to the datasheet and avoid adding external capacitance to output or control lines unless the timing specification permits it.
The AD7874BN is a legacy, obsolete device, so component substitution must begin with the full pinout, timing, electrical-limit, and environmental-grade comparison. The 28-pin through-hole package makes mechanical replacement straightforward, but package family alone does not prove functional interchangeability. For a service or redesign, verify the selected lot, inspect solder-joint compatibility, and confirm that a common reference and clock arrangement does not introduce loading or sequencing differences.
Informações de conformidade
The industrial-temperature classification is identified by distributor product information, but no explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations were present in the available product information. AEC-Q100 is not applicable to this non-automotive data acquisition IC.