DS90CR561MTD - LVDS Flat Panel Interface | Texas Instruments
N.º da peça: DS90CR561MTD ✗ Fim de vidaDS90CR561MTD Visão geral
An LVDS flat-panel interface IC is a semiconductor device used to connect digital video or control logic to display-related circuitry through low-voltage differential signaling. Within the broader hierarchy, an LVDS interface IC belongs to interface ICs, data converters and communication devices, and ultimately to integrated circuits. Differential signaling can reduce susceptibility to common-mode interference compared with single-ended interconnects, provided the transmitter, receiver, connector, and printed-circuit-board geometry are designed together.
The DS90CR561MTD provides a defined integration point for flat-panel display equipment. Its 48-pin TSSOP package supports conventional surface-mount assembly and external decoupling, power, ground, and differential-signal routing. Because this page does not reproduce the complete manufacturer datasheet, detailed electrical limits should be confirmed in the manufacturer documentation before finalizing a PCB, selecting termination networks, or calculating signal-integrity margins.
Potential uses include digital flat-panel display controllers, industrial HMI panels, test and measurement equipment, medical display interfaces, and embedded human-machine-interface systems. The part is most relevant when the system architecture already uses an LVDS display link and the designer can confirm compatibility with the DS90CR561 interface requirements.
When designing a PCB around the DS90CR561MTD, preserve the manufacturer's recommended pin assignments, component placement, and differential-pair geometry. Validate power sequencing, input thresholds, output timing, and termination values against the official datasheet. Do not infer missing electrical ratings from the distributor category label or the abbreviated package description.
This page combines the confirmed 48-TSSOP LVDS flat-panel interface identification with engineering-oriented selection guidance, application analysis, package-aware alternatives, and design cautions. It is intended to accelerate engineering triage while keeping unconfirmed electrical details separate from verified product facts.
Alternativas drop-in para DS90CR561MTD — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com DS90CR561MTD (mesmo formato e footprint) — diferindo em Package, Product Type.
DS90CF561MTD
✅ Drop-In ⚠️ Especificações não verificadas📋 Alternativa de referência (fora do catálogo)
DS90CF562MTD
✅ Drop-In ⚠️ Especificações não verificadasConsulte o preço
Ver ficha técnica →DS90CR213MTD
✅ Drop-In ⚠️ Especificações não verificadasConsulte o preço
Ver ficha técnica →DS90CR561MTD Especificações
| Product Type | Interface IC |
| Interface Application | LVDS Flat Panel Display |
| Manufacturer | Texas Instruments |
| Legacy Manufacturer | National Semiconductor |
| Encapsulamento | 48-pin TSSOP |
| Contagem de pinos | 48 pins |
| Tipo de montagem | Surface mount |
| Nominal Interface Voltage | 0.45 V |
Guia de Configuração de Pinos do DS90CR561MTD 48-pin tssop
Configuração de pinos para DS90CR561MTD (pacote 48-pin tssop). A numeração dos pinos, funções e diagramas de conexão estão definidos no datasheet do fabricante. Consulte-o para o footprint exato e diretrizes de soldagem.
Nenhum dado detalhado de pinagem disponível para DS90CR561MTD.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
DS90CR561MTD é adequado para 6 aplicaçãos: Digital Flat-Panel Display Interface, Industrial HMI Panel, Medical Display Interface, Test and Measurement Display, Embedded Human-Machine Interface, Video Processor Display Output.
Digital Flat-Panel Display Interface
The Texas Instruments DS90CR561MTD is explicitly identified for LVDS flat-panel display interfaces, making it relevant when a controller must link digital display data through a low-voltage differential interface. The confirmed 48-pin TSSOP package provides a defined surface-mount footprint, while the listed 0.45 V value identifies an interface-related electrical characteristic that must be mapped to the correct manufacturer specification. In a display board, the device would occupy the interface layer between source logic and panel-side circuitry. Designers should preserve the recommended differential-pair geometry, provide local supply bypassing, and validate lane timing, termination, and connector mapping against the exact datasheet before release.
Recomendado
Industrial HMI Panel
The DS90CR561MTD can be evaluated for an industrial human-machine-interface panel that uses an LVDS display connection and requires a dedicated interface IC rather than a general-purpose digital transceiver. The 48-pin TSSOP package is suitable for compact surface-mount assembly, and the family's flat-panel display positioning aligns with controller-to-panel signal routing. For industrial use, the design must verify supply tolerance, temperature range, ESD requirements, ground architecture, and display timing against the official documentation. The confirmed 0.45 V interface value should not be assigned a functional meaning until the associated parameter and test conditions are identified in the datasheet.
Recomendado
Medical Display Interface
The DS90CR561MTD is a candidate for medical display systems that already standardize on an LVDS link compatible with the DS90CR561 interface. Its defined role as a flat-panel display interface IC can simplify the signal-chain partitioning between imaging or control electronics and the display subsystem. Medical applications still require a complete system risk review covering electrical isolation, leakage, ESD immunity, fault behavior, and applicable equipment standards. Use the exact DS90CR561MTD datasheet to confirm supply levels, data timing, pin assignments, and operating temperature before selecting it for a medical-grade design.
Recomendado
Test and Measurement Display
A bench instrument or automated test system can use the DS90CR561MTD when its display subsystem requires the specific LVDS flat-panel interface behavior associated with the DS90CR561 family. The 48-pin TSSOP package makes the device practical for a compact interface section beside a controller or FPGA. However, measurement accuracy is not guaranteed merely by using a differential interface; display timing, source synchronization, grounding, and cable or connector behavior must meet the instrument's display-performance requirements. Confirm all timing and electrical limits in the manufacturer documentation and review conducted and radiated emissions for the finished enclosure.
Recomendado
Embedded Human-Machine Interface
The DS90CR561MTD fits an embedded HMI concept in which a processor or programmable logic device drives a high-resolution panel through an LVDS display link. Its confirmed 48-pin TSSOP package supports conventional PCB assembly and allows the interface circuitry to be placed near the panel connector or logic device. The implementation must account for signal-pair impedance, return-path continuity, connector pin mapping, and power sequencing. Because the available product information does not publish lane count, maximum data rate, or timing tolerances, engineers should select it only after matching those parameters to the panel and host-controller specifications.
Recomendado
Video Processor Display Output
The DS90CR561MTD may be used in a display-output stage that connects a video-processing or graphics subsystem to an LVDS panel. Its DS90CR561 family identity aligns with flat-panel interface duties, while the 48-pin TSSOP package provides enough interconnect capacity for power, configuration, and differential signaling. A successful design depends on exact compatibility with the processor's output format and the panel's timing. Review the data sheet for differential voltage limits, timing tolerances, serial configuration, and power requirements, and validate the complete link with representative source and display equipment before production.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para DS90CR561MTD — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | DS90CF561MTD | DS90CF562MTD | DS90CR213MTD |
|---|---|---|---|---|
| Package | 48-pin TSSOP | 48-pin TSSOP | 48-pin TSSOP | 48-pin TSSOP |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
Principais diferenciais
- Exact DS90CR561 family positioning (vs DS90CF561MTD)
- Confirmed package format (vs DS90CF562MTD)
- Target-specific application identification (vs DS90CR213MTD)
Notas de projeto
Route all LVDS differential pairs as tightly coupled pairs with continuous reference planes and matched termination provisions. Keep the DS90CR561MTD close to the panel connector or LVDS transceiver boundary, and avoid routing display signals beneath switching supplies, clock-generating circuitry, or high-current switching nodes. Verify pair spacing and length matching against the exact interface timing and connector requirements rather than relying on a generic rule.
Use the manufacturer-recommended supply topology, decoupling values, and placement for the DS90CR561MTD. Locate low-ESR bypass capacitors at the device power pins with very short ground returns, and keep analog or differential-signal returns away from noisy power-current paths. The confirmed 0.45 V value cannot be used to select a regulator without identifying its associated specification, so confirm supply rails, tolerances, and sequencing in the official datasheet.
Do not substitute a similarly named DS90CR, DS90CF, or DS90CR213 device based only on package size and interface classification. Confirm all 48 pin names, power polarity, configuration pins, LVDS lane mapping, data-rate limit, timing tolerance, and control logic for the exact MPN. A footprint match is necessary for drop-in consideration but does not establish electrical or functional equivalence.
Validate the complete display link with source-device, DS90CR561MTD, cable or connector, and panel models. Review edge rate, differential voltage, lane skew, clock or data timing, and termination behavior under worst-case panel traffic. If reflections, data errors, or horizontal-position instability appear, investigate reference-plane discontinuities, connector transitions, and pair-length mismatch before changing the interface device.
Informações de conformidade
Compliance declarations were not identified in the available product results. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification status using the exact manufacturer documentation.