MAX211IDBG4 - 5V Multichannel RS-232 Transceiver | Texas Instruments
N.º da peça: MAX211IDBG4 ✓ AtivoMAX211IDBG4 Visão geral
An RS-232 transceiver is an interface integrated circuit that combines logic-level driver and receiver functions with the voltage conversion required by the RS-232 standard. Within the signal-chain hierarchy, the MAX211IDBG4 belongs to the RS-232 interface IC class, connecting low-voltage digital systems to external serial ports. It is designed for equipment requiring multiple serial channels while conserving board space through a narrow surface-mount package.
The MAX211IDBG4 operates from a 5 V supply and contains four RS-232 drivers and five receivers. Its maximum signaling rate is 120 kbit/s, making it appropriate for legacy serial-console, industrial-control, point-of-sale, and embedded-system connections. The listed ±15 kV HBM ESD protection applies to the serial-port connection pins, including ground, while shutdown operation reduces supply current to a typical 1 µA.
Its dual charge-pump circuit generates the bipolar voltage levels used by RS-232 drivers from the 5 V supply. The device is specified to meet or exceed TIA/EIA-232-F and ITU V.28 requirements. This combination of integrated level translation, four transmit channels, five receive channels, and low-power shutdown makes the part useful where multiple serial interfaces must coexist on one board.
Typical applications include multiport serial adapters, industrial controller interfaces, test equipment, POS terminals, and embedded debug systems. The five receivers also permit one incoming line to be monitored while four other channels are active. Designers should account for the charge-pump capacitors and ensure that signal routing, grounding, and connector protection preserve the specified ESD and communication performance.
For a robust layout, place the charge-pump capacitors and interface bypass capacitor close to their associated pins, route transceiver outputs directly toward the connector, and maintain a low-impedance ground return. The 28-pin SSOP footprint reduces board area, but careful fan-out and signal-return management remain important because RS-232 uses single-ended signaling over relatively slow, long cable links.
This page combines the device's principal electrical characteristics, verified source links, interface-design guidance, and selection criteria for engineers evaluating the MAX211IDBG4 in multichannel RS-232 systems.
Alternativas drop-in para MAX211IDBG4 — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com MAX211IDBG4 (mesmo formato e footprint) — diferindo em Product Type, Number of Drivers, Number of Receivers, Operating Temperature Range, Package.
MAX211IDBRG4
✅ Drop-InConsulte o preço
Ver ficha técnica →MAX211IDBG4 Especificações
| Product Type | 1 multichannel RS-232 line driver/receiver |
| Tensão de alimentação | 5 V |
| Number of Drivers | 4 channels |
| Number of Receivers | 5 channels |
| Maximum Data Rate | 120 kbit/s |
| ESD Protection | ±15 kV using the Human-Body Model |
| ESD Protected Connections | 9 serial-port pins including ground |
| RS-232 Compliance | Meets or exceeds TIA/EIA-232-F |
| ITU Standard | Meets or exceeds ITU V.28 |
| Charge-Pump Circuit | 1 dual charge-pump circuit |
| Shutdown Supply Current | 1 µA typical |
| Package Type | 28-pin SSOP |
| Package Width | 5.30 mm |
| Terminal Count | 28 terminals |
| Estilo de montagem | Surface mount |
| Temperature Grade | Industrial |
Guia de Configuração de Pinos do MAX211IDBG4 5.30 mm
Configuração de pinos para MAX211IDBG4 (pacote 5.30 mm). A numeração dos pinos, funções e diagramas de conexão estão definidos no datasheet do fabricante. Consulte-o para o footprint exato e diretrizes de soldagem.
Nenhum dado detalhado de pinagem disponível para MAX211IDBG4.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
MAX211IDBG4 é adequado para 6 aplicaçãos: Industrial Multiport Serial Interface, POS Terminal and Peripheral Hub, Embedded Serial Console, Test and Measurement Equipment, Multiport Communication Adapter, RS-232 Port Expansion.
Industrial Multiport Serial Interface
The MAX211IDBG4 fits industrial controller and data-acquisition equipment that must expose several RS-232 ports from a limited board area. Its four drivers and five receivers support four outbound channels plus five incoming or monitoring lines, while the 28-pin SSOP package preserves routing space around dense control electronics. Operation from a 5 V supply and rates up to 120 kbit/s suit legacy equipment, service consoles, and programmable controllers. The ±15 kV HBM protection on serial-port connections improves robustness at exposed interfaces, although the final enclosure, cable routing, ground reference, and surge strategy must also be engineered for the installation environment.
Recomendado
POS Terminal and Peripheral Hub
The MAX211IDBG4 can support point-of-sale terminals, receipt printers, scanners, and service interfaces that use several RS-232 connections. Four transmitter channels allow the host to command multiple peripherals, while five receivers permit acknowledgement, status, or incoming-data lines to be monitored simultaneously. The 5 V architecture integrates the charge-pump needed for RS-232 voltage levels, and the 120 kbit/s maximum rate covers common legacy peripheral baud rates. Designers should keep each cable route away from fast digital signals, provide a continuous ground reference, and place the required charge-pump capacitors close to the device for dependable driver operation.
Recomendado
Embedded Serial Console
The MAX211IDBG4 is useful in embedded systems that retain an RS-232 service or diagnostics interface alongside several other serial connections. The four drivers and five receivers provide flexibility for command, response, reset, and status lines without requiring a separate transceiver for every channel. Its typical shutdown current of 1 µA helps conserve power when the interface is inactive, although system shutdown sequencing must keep the 5 V rail valid while the device is operating. The narrow 28-pin SSOP package is practical for compact controller boards, but careful fan-out, capacitor placement, and return-path design are necessary to prevent transient noise from coupling into adjacent digital or analog circuits.
Recomendado
Test and Measurement Equipment
The MAX211IDBG4 can serve as the host-side RS-232 interface in programmable test equipment, fixture controllers, and laboratory adapters. Multiple transmit channels support separate commands or control signals, and the five receivers can monitor equipment responses, interlocks, and status lines. The 120 kbit/s rate is appropriate for many legacy RS-232 instruments, while the integrated ESD protection strengthens the connector-facing portion of the design. Instrument engineers should still evaluate common-mode voltage, ground offsets, cable capacitance, and isolation needs; the transceiver regulates RS-232 levels but does not itself provide galvanic isolation or protection for every externally applied condition.
Recomendado
Multiport Communication Adapter
The MAX211IDBG4 is appropriate for compact adapters that translate a host connector into several RS-232 ports. Four drivers can feed four downstream devices, and five receivers can accept commands or status signals from multiple sources. Its 5 V-only supply arrangement simplifies power design, and the SSOP-28 package enables a narrow adapter board. For reliable operation, route driver outputs and receiver inputs away from switching nodes, preserve the RS-232 ground return, and install the charge-pump and bypass capacitors according to the manufacturer layout guidance. If a new design requires data rates above 120 kbit/s, longer unrepeated cable runs, or modern high-speed differential links, a different interface technology should be evaluated.
Recomendado
RS-232 Port Expansion
The MAX211IDBG4 can expand a controller's limited serial resources by adding four RS-232 transmit channels and five receive channels in one package. This is useful in peripheral controllers, maintenance equipment, and legacy automation platforms where several devices must be connected or monitored. The 120 kbit/s operating limit and TIA/EIA-232-F and ITU V.28 compatibility make it suited to established RS-232 ecosystems, while ±15 kV HBM protection helps reduce ESD risk at connected ports. The extra receiver channel supports handshake or status monitoring, but software must map each signal correctly because sharing compatible functions does not make every implementation automatically protocol-compatible.
Recomendado
Dados de referência de engenharia para MAX211IDBG4 — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
MAX213IDBR appears in comparison listings, but it should not be treated as a drop-in replacement without comparing its receiver count, pin functions, package geometry, electrical limits, and supply requirements. No other candidate is established as pin-to-pin compatible in the verified cross-reference information, so PCB reuse cannot be promised. Consider a different interface family when the system requires operation above 120 kbit/s, galvanic isolation, modern differential signaling, or protection against severe industrial surge events.
Comparação com alternativas
| Parâmetro | Este produto |
|---|---|
| Package | 28-pin SSOP |
| Brand | Texas Instruments |
| Product Type | Multichannel RS-232 line driver/receiver |
| Supply Voltage | 5 V |
| Number of Drivers | 4 channels |
| Number of Receivers | 5 channels |
| Maximum Data Rate | 120 kbit/s |
| ESD Protection | ±15 kV HBM |
| Shutdown Supply Current | 1 µA typical |
| RS-232 Standards | TIA/EIA-232-F and ITU V.28 |
Principais diferenciais
- Five receivers provide more inbound channel capacity (vs MAX213IDBR)
- Five-volt integration simplifies dual-rail interface design (vs MAX213IDBR)
- Specified connector-side ESD protection (vs MAX213IDBR)
Notas de projeto
Place the charge-pump capacitors and supply bypass capacitor close to their designated MAX211IDBG4 pins, and minimize loop area around the switching charge-pump nodes. Route each charge-pump connection directly to its capacitor without detours through protected or sensitive areas. Keep the interface ground and cable-return path continuous to the connector, because an interrupted ground reference can degrade RS-232 noise immunity even when the data and control wiring are correct.
Separate RS-232 driver outputs from receiver inputs and nearby sensitive circuitry wherever the board area permits. Driver outputs undergo high-voltage transitions generated by the charge pump, so their routing can couple noise into adjacent signals. Use a continuous ground plane, avoid splitting the ground beneath the transceiver, and maintain practical clearance between external cable-side nets and low-level digital or analog traces.
Do not treat the ±15 kV HBM rating as protection for every industrial surge or cable condition. External cable transients, long ground offsets, and improper connector grounding may exceed the intended application environment. Evaluate the complete signal path, add appropriate surge protection where required, and confirm that the 5 V supply remains within its operating limits during startup, shutdown, and load transients.
RS-232 signaling is single-ended, so receiver inputs depend on a stable reference to the interface ground. Avoid routing a receiver input beside a driver output or switching regulator node, and terminate unused inputs in the manner specified by the manufacturer. For long cables or high baud rates, evaluate capacitance, attenuation, reflections, and common-mode noise; the IC's 120 kbit/s limit does not guarantee reliable communication over every cable length.
Informações de conformidade
The device is identified as an industrial-grade RS-232 interface IC. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations are not stated in the verified source excerpts.