MAX3232IDWRE4 - 250kbps Dual RS-232 Transceiver | Texas Instruments
N.º da peça: MAX3232IDWRE4 ✓ AtivoMAX3232IDWRE4 Visão geral
An RS-232 interface transceiver is an interface IC that converts digital logic-level signals into RS-232 line levels and converts incoming RS-232 signals back into logic-level voltages. In the hierarchy of electronic components, this dual transceiver belongs to the RS-232 interface IC family, interface IC category, and broader semiconductor and signal-conditioning product classes. The MAX3232 combines both directions of conversion on one device, reducing the component count in equipment that requires more than one serial communication channel.
The MAX3232IDWRE4 operates from 3 V to 5.5 V, supports data rates up to 250 kbps, and integrates two drivers with two receivers. Its 16-SOIC package measures 0.295 inches, or 7.50 mm, in width. The industrial temperature grade supports applications operating from -40°C through 85°C, while its dual architecture suits systems needing two transmit and two receive channels.
The device uses charge-pump circuitry to generate the positive and negative voltages required by the RS-232 electrical interface. According to the MAX3232 documentation, the serial-port connection pins provide plus-or-minus 15 kV ESD protection. The circuit also meets the electrical-interface requirements of TIA/EIA-232-F. These features make it appropriate for legacy and industrial serial links where logic-level UART signaling must cross into an RS-232 connection.
Typical applications include industrial controller links, programmable-logic-controller serial communication, instrumentation, barcode-scanner interfaces, and legacy computer serial ports. A single MAX3232 can support two RS-232 channels, but each channel still requires the correct external charge-pump capacitors, signal routing, ground reference, and connector protection required by the system interface.
The primary design consideration is charge-pump capacitor selection and placement. Use the capacitor values specified by the manufacturer datasheet and place them close to the corresponding IC pins to minimize switching noise and unstable charge-pump behavior. Confirm that the host UART logic levels, baud rate, signal polarity, and RS-232 connector wiring match the target equipment.
This product page combines the verified MAX3232IDWRE4 electrical and mechanical characteristics with same-package drop-in alternatives, parameter-by-parameter comparison, application guidance, and practical PCB considerations. It is intended to help engineers identify whether the MAX3232IDWRE4 fits a new RS-232 design or whether a listed replacement offers a better sourcing or lifecycle option.
Alternativas drop-in para MAX3232IDWRE4 — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com MAX3232IDWRE4 (mesmo formato e footprint) — diferindo em Number of Drivers, Number of Receivers, Product Type, Supply Voltage Range.
MAX3232IDWR
✅ Drop-InConsulte o preço
Ver ficha técnica →MAX3232EIDR
✅ Drop-InConsulte o preço
Ver ficha técnica →MAX3232ECDR
✅ Drop-InConsulte o preço
Ver ficha técnica →ADM3202ARWZ-REEL
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
SP3232EET-L
✅ Drop-InConsulte o preço
Ver ficha técnica →ICL3232IBNZ
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
MAX3232IDWRE4 Especificações
| Product Type | Dual RS-232 line driver/receiver transceiver |
| Number of Drivers | 2 drivers |
| Number of Receivers | 2 receivers |
| Supply Voltage Range | 3 V to 5.5 V |
| Maximum Data Rate | 250 kbps |
| Faixa de temperatura de operação | -40°C to +85°C |
| Encapsulamento | 16-SOIC |
| Package Width | 7.50 mm (0.295 inch) |
| Terminal Count | 16 terminals |
| Estilo de montagem | Gull-wing surface mount |
| Temperature Grade | Industrial |
| ESD Protection | ±15 kV on serial-port connection pins |
| RS-232 Standard | TIA/EIA-232-F |
Configuração de pinos do MAX3232IDWRE4
| Pino 1 | C1+ — Charge-pump flying capacitor positive terminal |
| Pino 2 | C1- — Charge-pump flying capacitor negative terminal |
| Pino 3 | C2+ — Charge-pump flying capacitor positive terminal |
| Pino 4 | C2- — Charge-pump flying capacitor negative terminal |
| Pino 5 | V+ — Charge-pump positive voltage output |
| Pino 6 | C2+ — Charge-pump capacitor connection |
| Pino 7 | R1OUT — Receiver 1 logic output |
| Pino 8 | R2OUT — Receiver 2 logic output |
| Pino 9 | R2IN — Receiver 2 RS-232 input |
| Pino 10 | R1IN — Receiver 1 RS-232 input |
| Pino 11 | T2IN — Driver 2 logic input |
| Pino 12 | T1IN — Driver 1 logic input |
| Pino 13 | GND — Ground connection |
| Pino 14 | VCC — Positive supply voltage |
| Pino 15 | T1OUT — Driver 1 RS-232 output |
| Pino 16 | T2OUT — Driver 2 RS-232 output |
Aplicações típicas
MAX3232IDWRE4 é adequado para 6 aplicaçãos: Industrial Controller Serial Communication, Test and Measurement Instruments, Barcode Scanner and Data Collection, Legacy Computer Serial Port Interface, Network Equipment Console Access, Embedded UART-to-RS-232 Conversion.
Industrial Controller Serial Communication
The MAX3232IDWRE4 fits dual-channel serial communication in industrial controllers, HMIs, and programmable-logic-controller systems. Its two drivers and two receivers can support two RS-232 ports, while the 3 V to 5.5 V supply range accommodates both 3.3 V and 5 V control electronics. The specified -40°C to +85°C range covers factory environments with substantial temperature variation. Designers should follow the datasheet charge-pump capacitor values, place them close to the IC, and verify the logic levels and connector pinout of each connected controller.
Recomendado
Test and Measurement Instruments
The MAX3232IDWRE4 is useful in test and measurement instruments that must communicate with RS-232 service ports, computers, or legacy analyzers. Its 250 kbps maximum data rate covers common UART baud rates, and the dual-channel arrangement reduces the number of interface components needed. The ±15 kV ESD protection on the serial-port connection pins adds useful protection for externally accessible equipment. The enclosure and cable path still require suitable transient protection, a defined signal ground, and connector-level surge mitigation.
Recomendado
Barcode Scanner and Data Collection
A MAX3232IDWRE4 can bridge a scanner, reader, or data-collection terminal to an RS-232 host. The 3 V to 5.5 V operating range allows the interface to share common embedded-system rails, while 250 kbps is suitable for conventional serial scanners. Two drivers and two receivers make the device practical when one port carries host commands and another carries auxiliary equipment. Keep RS-232 cable routing away from high-current switching paths and validate that the scanner uses the same logic polarity and connector wiring.
Recomendado
Legacy Computer Serial Port Interface
The MAX3232IDWRE4 provides a compact interface for modern embedded controllers that must connect to a legacy RS-232 computer port. The dual-driver, dual-receiver arrangement supports two logical serial channels in one 16-SOIC package, and the 3 V to 5.5 V supply range simplifies adaptation to embedded logic rails. The maximum 250 kbps rate covers many legacy UART modes. Because RS-232 is point-to-point, verify whether the target port is configured as DTE or DCE and wire straight-through or crossover connections accordingly.
Recomendado
Network Equipment Console Access
The MAX3232IDWRE4 can support service-console and equipment-maintenance links in network appliances where RS-232 remains available for installation or diagnostics. Two channels allow one console port and one auxiliary interface, while the 250 kbps rate is appropriate for terminal sessions and configuration traffic. Industrial temperature qualification supports equipment installed in controlled network cabinets and telecommunications rooms. Design the interface with proper chassis grounding, cable shielding, and electrostatic-discharge protection at the exposed connector.
Recomendado
Embedded UART-to-RS-232 Conversion
The MAX3232IDWRE4 is appropriate when a microcontroller, DSP, or application processor requires RS-232 instead of TTL or CMOS UART levels. Its two transmitters and two receivers permit multiple serial links, and the 3 V to 5.5 V operating range supports common embedded supply voltages. At rates up to 250 kbps, the interface suits configuration ports, data acquisition links, and peripheral communication. Confirm the host UART voltage, baud rate, parity format, and signal direction before connecting the RS-232 connector.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para MAX3232IDWRE4 — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | MAX3232IDWR | MAX3232EIDR | MAX3232ECDR | ADM3202ARWZ-REEL | SP3232EET-L |
|---|---|---|---|---|---|---|
| Package | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices | Exar |
Principais diferenciais
- Exact same-family alternative with identical headline electrical ratings (vs MAX3232IDWR)
- Manufacturer-recommended improved family for new designs (vs MAX3232EIDR)
- Dual-channel integration reduces interface component count (vs ADM3202ARWZ-REEL)
- Specified industrial temperature and ESD capability (vs SP3232EET-L)
Notas de projeto
Place the charge-pump capacitors as close as practical to their associated MAX3232IDWRE4 pins, and minimize loop area around the flying-capacitor and storage-capacitor connections. Use the capacitance and tolerance specified by the manufacturer datasheet. Short, direct traces reduce switching transients and help the charge-pump circuitry maintain stable RS-232 output levels.
Do not assume that every 16-SOIC RS-232 transceiver has an identical pin arrangement or external-capacitor configuration. Before substituting MAX3232IDWR, MAX3232E, ADM3202ARWZ, SP3232E, or ICL3232IBNZ, compare the complete pin-description tables, charge-pump connections, shutdown functions, driver polarity, receiver thresholds, and data-rate ratings against the existing PCB.
Route RS-232 driver outputs directly toward the connector and keep receiver inputs away from noisy digital, switching-power, and relay paths. Maintain a consistent signal-ground reference between the transceiver and connector. For externally accessible cables, evaluate connector-level surge and ESD protection separately from the MAX3232IDWRE4's specified ±15 kV pin protection.
Check UART baud rate, cable length, connector wiring, and the host's DTE or DCE configuration before release. The MAX3232IDWRE4 supports rates up to 250 kbps, but the complete link also depends on the host UART, cable characteristics, grounding, and loading. For noisy industrial installations, verify that the interface remains stable under worst-case supply and cable conditions.
Informações de conformidade
The MAX3232IDWRE4 is an industrial-temperature interface IC. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations should be confirmed from the current manufacturer product documentation or declaration before use in a regulated production design.