NXP Semiconductors

MPXV5010DP - 10kPa Differential Pressure Sensor | NXP

N.º da peça: MPXV5010DP ✓ Ativo
Em estoque Enviado em 1 a 3 dias úteis
0.2 V to 4.7 V Vdss 8-BSOP (0.475 in / 12.06 mm width), Dual Ports Package
A partir de $8.1 USD / unidade
MOQ: 1 |
Preço atualizado: 2026-10-15
Preços por volume
Qtd. Preço unitário Total
1 $13.5 $13,50
10 $12.1 $121,00
100 $10.5 $1.050,00
500 $9.2 $4.600,00
1.000 $8.1 $8.100,00
ℹ️ Todos os preços estão em USD

MPXV5010DP Visão geral

The NXP MPXV5010DP is an integrated piezoresistive pressure sensor delivering a 0 to 10 kPa (0 to 1.45 PSI) differential measurement range with on-chip signal conditioning, temperature compensation and calibration. Housed in an 8-BSOP surface-mount package (12.06 mm width) with dual pneumatic ports on the same side, the device provides a ratiometric analog output of 0.2 V to 4.7 V proportional to applied differential pressure at 5 V excitation.

A pressure transducer is a sensor that converts a physical pressure input into an electrical signal, typically using a piezoresistive strain gauge arrangement embedded in a silicon diaphragm. Within the broader sensor hierarchy, the MPXV5010DP sits under differential pressure sensors, which belong to MEMS sensors, which in turn belong to integrated semiconductor sensors. By integrating the sense element, amplifier, calibration and temperature compensation into one monolithic die, this category of devices eliminates the need for external signal chains and delivers a calibrated, linear analog output ready for direct connection to a microcontroller ADC.

Key specifications include a 5 V nominal supply (maximum 5.25 V), a typical full-scale output of 4.7 V, a stated accuracy of 5% over 0 to 85 degrees Celsius, and a 1 ms response time. The combination of integrated temperature compensation (from 0 to 85 C) and factory calibration provides a stable transfer function without user-side trimming. Ratiometric output ensures that output voltage scales linearly with supply voltage, simplifying ADC interface design.

Architecturally, the MPXV5010DP uses a monolithic silicon die combining a micromachined diaphragm, bipolar signal conditioning and laser-trimmed thin-film resistors. The on-chip amplification and temperature compensation deliver a nominal 5% accuracy across the commercial temperature range. Total Error Band (TEB) is specified over the compensated range, enabling direct ADC conversion without external linearization.

Typical applications include medical respiratory monitoring and airflow measurement, HVAC variable-air-volume (VAV) systems, industrial process control, and consumer appliance pressure sensing. The 0-10 kPa range also maps well to spirometer flow heads and cleanroom pressure differentials.

When designing with the MPXV5010DP, decouple the supply with a 100 nF ceramic bypass capacitor placed within 5 mm of the VCC and GND pins. The differential pneumatic lines should be sized to minimize windage errors at the intended flow bandwidth, and the dual-port configuration requires careful port-plumbing orientation to avoid cross-port pressure leakage.

This page consolidates verified distributor pricing, drop-in alternatives and practical design considerations for the MPXV5010DP that go beyond the manufacturer datasheet alone.

Alternativas drop-in para MPXV5010DP — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com MPXV5010DP (mesmo formato e footprint) — diferindo em Package, Port Style, Operating Temperature, Supply Voltage, Operating Pressure Range.

NXP Semiconductors
Port Style: Dual Ports, Same Side
Operating Pressure Range: ±3.63 PSI (±25 kPa)
Comparar com MPXV5010DP →
NXP Semiconductors
Package: 6-SIP Module
Operating Temperature: 0 C to +85 C (compensated)
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Comparar com MPXV5010DP →
NXP Semiconductors
Package: 8-BSOP (CASE 1351-01), 12.06 mm width
Operating Temperature: 0°C to +85°C
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Comparar com MPXV5010DP →
NXP Semiconductors
Package: 8-SO (Small Outline), Gull-Wing SMD
Operating Temperature: 0 C to +85 C
Operating Pressure Range: 0 kPa to 10 kPa (0 PSI to 1.45 PSI)
Comparar com MPXV5010DP →
NXP Semiconductors
Package: 8-pin SOP (Small Outline Package), SMD Gull Wing
Port Style: Top port, male 0.13 inch (3.17 mm) tube
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Comparar com MPXV5010DP →
STMicroelectronics
Package: 8-SMD, Gull Wing, Side Port
Port Style: Male - 3.17 mm (0.13 in) Tube, Side Port
Operating Temperature: 0 C to +85 C
Comparar com MPXV5010DP →
NXP Semiconductors
Operating Temperature: 0 C to +85 C
Operating Pressure Range: 0 kPa to 50 kPa (0 psi to 7.25 psi)
Comparar com MPXV5010DP →
NXP Semiconductors
Package: 8-BSOP (0.475 inch, 12.06 mm width), dual ports same side
Port Style: Dual horizontal ports, same side
Supply Voltage: 4.75 V to 5.25 V (nominal 5 V)
Comparar com MPXV5010DP →
NXP Semiconductors
Package: 8-BSOP (SOP-8, 12.06 mm width), surface mount
Port Style: Dual ports, same side, male 0.13" (3.3 mm) tube
Operating Temperature: 0 °C to +85 °C
Comparar com MPXV5010DP →
NXP Semiconductors
Port Style: Single side port with barbed stem
Operating Temperature: -40C to +125C
Supply Voltage: 5 V typical (ratiometric output)
Comparar com MPXV5010DP →

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

MPXV5010GP

✅ Drop-In
STMicroelectronics
📦 8-BSOP (single port)
Vented Gauge · 0 kPa to 10 kPa (0 PSI to 1.45 PSI) · 10 kPa · Analog Voltage · 0.2 V to 4.7 V · 5 V · 5 mA typical · 450 mV/kPa (approx, 0.2-4.7 V span)

✓ Em estoque

$9.95 / unidade

Ver ficha técnica →

MPXV5004DP

✅ Drop-In
NXP Semiconductors
📦 8-BSOP (dual ports, same side)
Differential (Dual Port, Same Side) · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · Male Tube, 3.3 mm O.D., Dual Same-Side · 4.75 V to 5.25 V (5 V typical) · 10 mA typical · 1.0 V to 4.9 V at 5 V supply · Analog, Ratiometric to VCC · ±1.5% Vfss typical (after auto-zero)

✓ Em estoque

$7.4 / unidade

Ver ficha técnica →

MPXV5050DP

✅ Drop-In
NXP Semiconductors
📦 8-BSOP (dual ports, same side)
Differential · 0 kPa to 50 kPa (0 psi to 7.25 psi) · 200 kPa · 4.75 V to 5.25 V (5 V typical, max 6.0 V) · Analog ratiometric voltage · 0.2 V to 4.7 V at Vdd = 5 V · Vout = 5 V x (0.009 x P_kPa - 0.045)

✓ Em estoque

$5.95 / unidade

Ver ficha técnica →

MPXV5100DP

✅ Drop-In
NXP Semiconductors
📦 8-BSOP (dual ports, same side)
Differential · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · Analog, Ratiometric Voltage · 0.2 V to 4.7 V · 4.75 V to 5.25 V (nominal 5 V) · 45 mV/kPa (nominal) · +/- 5% (max, over compensated range)

✓ Em estoque

$9.1 / unidade

Ver ficha técnica →

MPX5010DP

✅ Drop-In
NXP Semiconductors
📦 Unibody (TO-3 style through-hole)
Differential · 0 kPa to 10 kPa (0 to 1.45 PSI) · 450 mV/kPa (typical) · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · ±1.5% VFSS (typical, 0-85 C)

✓ Em estoque

$9.6 / unidade

Ver ficha técnica →

MPXV5010DP Classificações máximas e características elétricas

Pressure Type Differential
Operating Pressure Range 0 to 10 kPa (0 to 1.45 PSI)
Tipo de saída Analog, Ratiometric
Faixa de tensão de saída 0.2 V to 4.7 V
Tensão de alimentação 5 V nominal (4.75 V to 5.25 V)
Accuracy 5 % (over 0 C to 85 C)
Response Time 1 ms typical
Temperatura de operação -40 C to +125 C
Compensated Temperature 0 C to 85 C
Port Style Male, 0.13 in (3.3 mm) tube, Dual, Same Side
Encapsulamento 8-BSOP (0.475 in / 12.06 mm width), Dual Ports
Tipo de montagem Surface Mount
Technology Piezoresistive, MEMS, On-chip Signal Conditioned
Status RoHS Compliant

Configuração de pinos do MPXV5010DP

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pino 1 N/C — Not connected
Pino 2 Vs — Voltage supply (5 V nominal)
Pino 3 GND — Ground
Pino 4 Vout — Analog output (0.2 V to 4.7 V)
Pino 5 N/C — Not connected
Pino 6 N/C — Not connected
Pino 7 N/C — Not connected
Pino 8 N/C — Not connected

Aplicações típicas

MPXV5010DP é adequado para 7 aplicaçãos: Medical Spirometer / Respiratory Flow Sensing, HVAC Variable Air Volume (VAV) Box Sensing, Industrial Process Differential Pressure Monitoring, Cleanroom and Operating-Room Pressure Cascade, Consumer Appliance Airflow and Filter Monitoring, Coffee Machine and Beverage Dispenser Flow Verification, Drone Altitude and Wind-Gust Sensing.

💊

Medical Spirometer / Respiratory Flow Sensing

The MPXV5010DP's 0-10 kPa differential range maps directly onto the pressure drop across a Fleisch-type or Lilly-type flow head used in spirometers. Its 1 ms response time captures fast flow transients during forced expiration, while on-chip temperature compensation (0 to 85 C) keeps calibration stable across patient and ambient temperatures. The ratiometric 0.2 V to 4.7 V output swings nearly the full input range of a typical 5 V ADC, maximizing resolution. Place a 100 nF decoupling cap within 5 mm of the Vs pin and apply a small-leak medical-grade silicone tube to the dual same-side ports. Compared with raw bridge sensors, the integrated amplifier and calibration eliminate the need for an external instrumentation front-end.

🏭

HVAC Variable Air Volume (VAV) Box Sensing

Building-automation VAV controllers sense the differential pressure across an orifice plate to compute airflow in cubic feet per minute. The MPXV5010DP's 0-10 kPa span matches typical 0.05 to 1 inch water column working ranges scaled to the orifice, and its 5 V ratiometric output is compatible with standard 0-5 V building-controller analog inputs. The 8-BSOP SMT form factor enables integration onto compact VAV-blocks controller PCBs alongside microcontroller I/O. Use a particle filter upstream of the dual ports to prevent contamination; both ports can be referenced to room and duct sides of the orifice plate with matched pneumatic lines to avoid windage errors. On-chip calibration removes the need for field trimming.

🏭

Industrial Process Differential Pressure Monitoring

Industrial process plants use differential pressure sensors to monitor filters, strainers and heat-exchanger fouling by measuring pressure drop across them. The MPXV5010DP provides a 4.7 V full-scale output at 5 V supply, giving high signal headroom relative to typical 24-bit plant ADC inputs. Its -40 C to +125 C operating range covers most outdoor panel enclosures, and the dual same-side 3.3 mm tube ports accept industry-standard pneumatic fittings. Mechanically isolate the package from high-vibration environments and route ports through short lengths of silicone tubing to dampen pump-induced pulsations. The integrated calibration simplifies PLC-scale commissioning.

💊

Cleanroom and Operating-Room Pressure Cascade

Hospitals and semiconductor fabs monitor differential pressure between rooms of differing cleanliness classes to maintain airflow direction. The MPXV5010DP's 5 percent accuracy and 1 ms response support the realtime pressure-gradient alarms mandated in cleanroom and OR applications. The dual-port configuration lets one port sense room A and the other room B through wall-mounted pitot tubes or grills. Matched tubing lengths keep both ports at the same pneumatic time-constant for stable readings. On-chip calibration removes the field-trim step used with raw bridge sensors, simplifying wall-mount commissioning.

🏭

Consumer Appliance Airflow and Filter Monitoring

Vacuum cleaners, range hoods and HVAC registers benefit from filter-load sensing via differential pressure. The MPXV5010DP's 5 V single-supply operation suits appliance-grade electronics, and the ratiometric output is compatible with low-cost MCU ADCs. The 8-BSOP SMT package mounts on the main control PCB inside the appliance housing, with short pneumatic paths routed via tubing to either side of the filter. Low pressure noise and 5% accuracy are sufficient for 'replace filter' indication. Use dust-rated fittings and a coalescing filter to protect the ports in dusty environments.

🏭

Coffee Machine and Beverage Dispenser Flow Verification

In espresso machines and beverage dispensers, the differential pressure across a flow restriction verifies that the pump is delivering rated flow. The MPXV5010DP's 0-10 kPa range covers pump-head pressure drops used in counter-top coffee equipment, and the small 8-BSOP SMT footprint fits alongside the pump-driver board. Ratiometric 5 V output provides good dynamic range when read by the appliance's main MCU ADC. The dual ports allow sensing across an inline restriction without breaking the fluid path. Note that this use case assumes non-corrosive dry gas; for steam or moist airflow, additional moisture protection is required.

✈️

Drone Altitude and Wind-Gust Sensing

Small UAVs use pitot-style differential pressure to estimate airspeed and detect wind gusts. The MPXV5010DP's 1 ms response time resolves turbulence at hover and cruise, and its 4.75 V to 5.25 V supply range is compatible with regulated 5 V drone power rails. The dual same-side ports accept forward-facing and side-facing pitot tubes for differential measurements. On-chip calibration removes in-flight trim routines. Note that for high-speed fixed-wing UAVs a wider-range sensor such as MP3V5050GP may better match forward-velocity dynamic pressure; the MPXV5010DP is best suited to multirotor and slow-cruise profiles.

What is the operating pressure range of MPXV5010DP?
The MPXV5010DP measures differential pressure from 0 to 10 kPa (0 to 1.45 PSI). According to the NXP product page, the transducer delivers a ratiometric analog output of 0.2 V to 4.7 V that scales linearly across this range when excited from a 5 V supply. The 10 kPa span aligns with spirometer flow heads and cleanroom pressure-differential sensing.
Where to buy MPXV5010DP online?
The MPXV5010DP is in stock at major distributors including DigiKey, Mouser and Octopart-listed resellers (as of 2026-10-15). DigiKey lists the part under catalog number 531280 with same-day shipping on orders placed by cutoff. Compare pricing across at least 3 distributors to capture the best volume break before placing production orders.
What is the price of MPXV5010DP?
Pricing as of 2026-10-15: MPXV5010DP unit prices start around $13.50 at quantity 1, $10.50 at 100 pieces, and approximately $8.10 at 1000 pieces. Volume discounts apply at 500-piece breaks. Lead times for large reels are typically 6 to 10 weeks from NXP; check distributor stock for in-stock tray or cut-tape options if you need parts sooner.
What is the lead time for MPXV5010DP?
Lead time for MPXV5010DP (as of 2026-10-15) varies by distributor: distributor-tray stock typically ships in 2 to 4 weeks, factory-direct reels carry a 6 to 10 week lead time, and shortages have historically pushed allocation to 20+ weeks. For prototype builds, Octopart cross-listing surfaces smaller distributors with cutoff-delivery schedules.
Is MPXV5010DP in stock?
MPXV5010DP is widely stocked at authorized distributors. As of 2026-10-15, DigiKey shows >500 units available with same-day shipping, while smaller distributors hold varying amounts on allocation. Lifecycle status on the NXP product page is Active, and the part is not on any EOL notice, so designers can specify it without an alternate plan.
MPXV5010DP vs MPXV5004DP - which is better for airflow sensing?
The MPXV5010DP measures 0 to 10 kPa while the MPXV5004DP measures 0 to 4 kPa; choose MPXV5010DP for higher-pressure spirometry or VAV ducts, and choose MPXV5004DP for cleaner low-pressure drop readings where measurement-to-overload ratio matters. Both share the same 8-BSOP package and pinout, enabling drop-in substitution to fine-tune range.
What is the difference between MPXV5010DP and MPXV5010GP?
The MPXV5010DP has dual side-by-side ports of the same side of the package while the MPXV5010GP has a single port. Per the NXP community post, the DP and GP variants are fully pin-to-pin compatible at the electrical interface; the only layout change is the pneumatic port stub. Use the GP variant when only one pressure line is required.
When should I choose MPXV5010DP over MPXV7007DP?
Choose the MPXV5010DP when your maximum differential pressure is below 10 kPa - it offers higher resolution and accuracy in the lower-pressure range. Choose the MPXV7007DP for differential pressures up to 7 kPa where the design can benefit from a higher-overload headroom. Otherwise, both share the same 8-BSOP footprint and pinout.
What is the best drop-in replacement for MPXV5010DP?
The best drop-in replacements for the MPXV5010DP in the same 8-BSOP package are MPXV5010GP (single-port variant, fully pin-to-pin compatible on the electrical interface) and other MPxx5010 family devices such as MPXV5004DP and MPXV5050DP. For cross-brand drop-in, ask the manufacturer apps team for the SSCMRRN series or XGZP6883A after sampling.
Can SSCMRRN100KGAA5 replace MPXV5010DP?
The Honeywell SSCMRRN100KGAA5 is listed as a functional cross by Honeywell application engineers, but it is not a true pin-for-pin drop-in: the SSCMRRN uses a different package and pinout, so PCB rework and schematic changes are required. As a functional alternative it delivers a compatible 0-10 kPa analog output, but budget extra development time for the new footprint.
Where to download MPXV5010DP datasheet PDF?
The official MPXV5010DP product page on NXP.com (nxp.com/part/MPXV5010DP) is the primary source for the latest datasheet revision. Third-party mirrors such as Alldatasheet and DigiChip also host the PDF for convenience, but always cross-check the document number and revision against the NXP page to ensure you are working with the most current specification.
Where to find MPXV5010DP pinout?
MPXV5010DP pinout is documented in the NXP datasheet Style 2 section: pin 1 N/C, pins 2-3 Vs/GND, pin 4 Vout, and the pneumatic ports sit on the same side of the 8-BSOP body. For visual reference the package outline and pin location are also captured in the NXP community thread 'Which set of pin names to use for MPXV5010DP'.
What are the key specifications of MPXV5010DP that engineers should know?
The MPXV5010DP is a 10 kPa differential pressure sensor with 0.2 V to 4.7 V ratiometric output at 5 V supply, 5 percent total error from 0 to 85 C, 1 ms response time, and dual same-side pneumatic ports on an 8-BSOP surface-mount package. Compensation and calibration are on-chip, so the output is ADC-ready.
What can replace MPXV5010DP?
Genuine drop-in parts that share the MPXV5010DP 8-BSOP footprint are limited; MPXV5010GP (single-port), MPXV5004DP (0-4 kPa variant) and MPXV5050DP (0-50 kPa variant) are the closest same-package replacements. Functional alternatives that require PCB rework include the Honeywell SSCMRRN100KGAA5 and the CFSensor XGZP6883A in 10 kPa calibration.
What is the best Honeywell equivalent for MPXV5010DP?
Honeywell application engineers recommend the SSCMRRN100KGAA5 or ABPMRRN100KGAA5 as cross references for the MPXV5010DP. These parts share the 0-10 kPa range and ratiometric analog output but use a different package, so they are functional equivalents rather than drop-in. Plan PCB rework and ADC scaling verification when qualifying either part.

Dados de referência de engenharia para MPXV5010DP — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the MPXV5010DP when your design needs a calibrated 0 to 10 kPa differential pressure reading with 5 V single-supply operation and on-chip temperature compensation in a surface-mount 8-BSOP package. The part is well-suited to medical spirometers, HVAC VAV boxes, cleanroom pressure cascades and industrial filter monitoring where dual-port differential sensing simplifies plumbing. Pick the MPXV5010GP when only one pneumatic port is needed and a gauge reading suffices. Pick the MPXV5004DP, MPXV5050DP or MPXV5100DP family members when the working pressure range differs from 10 kPa but you want the same pinout. For cross-brand alternatives you must budget PCB rework because functional equivalents like the Honeywell SSCMRRN series do not share the 8-BSOP footprint.

Comparação com alternativas

Parâmetro Este produto MPXV5010GP MPXV5004DP MPXV5050DP MPXV5100DP MPX5010DP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-BSOP dual-port 8-BSOP single-port - same SMT footprint 8-BSOP dual-port - same 8-BSOP dual-port - same 8-BSOP dual-port - same Unibody TO-3 (through-hole) - not SMT
Pressure Type Differential Gauge (single port) Differential Differential Differential Differential
Operating Pressure Range 0 to 10 kPa 0 to 10 kPa 0 to 4 kPa 0 to 50 kPa 0 to 100 kPa 0 to 10 kPa
Output Voltage Range 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Operating Temperature -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C

Principais diferenciais

  • Dual-port, same-side pneumatic configuration in 8-BSOP (vs MPXV5010GP)
  • 10 kPa range matches spirometer and VAV-box working spans (vs MPXV5004DP)
  • On-chip temperature compensation and calibration (vs Raw bridge sensor)

Notas de projeto

Place a 100 nF X7R ceramic bypass capacitor within 5 mm of the Vs and GND pins to suppress supply-rail noise. The MPXV5010DP output is ratiometric to Vs, so any noise or ripple on the 5 V supply directly couples into Vout. For battery or low-noise applications, source Vs from a low-dropout regulator followed by a ferrite bead rather than a switching converter.

Keep the analog output trace short and routed away from switching nodes and high-current traces to minimize crosstalk. Match the pneumatic tube lengths to both ports so that port-to-port time constants are equal; mismatched tubes cause asymmetric windage and degrade differential readings. Mount the package clear of vibration sources because MEMS diaphragms can exhibit offset shift under sustained mechanical stress.

Do not apply pressure beyond the maximum overload limit - this permanently damages the diaphragm. Avoid condensing moisture or corrosive media contacting the ports; the integrated sensor is rated for non-corrosive dry gas only. Output voltage is referenced to GND at the IC; do not read Vout differentially against Vs because this double-counts the ratiometric excitation.

If reading the analog output with a microcontroller ADC, average 4 to 16 samples to suppress switching regulator noise and improve effective resolution by 2 to 4 bits. The 1 ms response time limits the noise bandwidth, so heavily oversampling adds little benefit. Add an RC low-pass filter on Vout (for example 10 kohm and 100 nF) when sampling rates exceed the mechanical bandwidth of the diaphragm.

Informações de conformidade

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Sem chumbo
Yes
Sem halogênios
Unknown
Minerais de conflito
Unknown

RoHS compliant per NXP product page. Lead-free process per NXP packaging documentation. Halogen-free and conflict-mineral status not stated in the verified data and marked unknown. AEC-Q100 not applicable for this commercial-grade pressure sensor.

Dados verificados em: 2026-10-15 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

MPXV5010DP MPXV5010DP datasheet NXP MPXV5010DP 10 kPa differential pressure sensor 8-BSOP pressure sensor NXP spirometer pressure sensor HVAC VAV pressure sensor MPXV5010DP vs MPXV5004DP MPXV5010DP drop-in replacement MPXV5010DP buy online price what is the pressure range of MPXV5010DP MPXV5010DP pinout 8-BSOP

Componentes & termos relacionados

NXP Semiconductors MPXV5010DP MPXV5010GP MPXV5004DP MPXV5050DP MPXV5100DP MPX5010DP Honeywell SSCMRRN100KGAA5 XGZP6883A pressure sensor differential pressure gauge pressure piezoresistive sensor MEMS sensor BSOP package surface mount RoHS spirometer HVAC VAV cleanroom pressure analog output ratiometric output temperature compensation
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ