OPA191ID - 36V Low-Power Precision CMOS Op Amp | Texas Instruments
N.º da peça: OPA191ID ✓ AtivoOPA191ID Visão geral
A CMOS precision operational amplifier is an analog building block that amplifies small voltage differences while operating close to its supply rails. The OPA191 belongs to the operational amplifier hierarchy, where precision amplifiers are used to preserve low-level sensor information, minimize offset error, and drive measurement or control stages accurately. Rail-to-rail input and output operation extends the usable common-mode and output range toward the supply limits.
Key characteristics include a maximum 36 V supply, low quiescent current of 0.14 mA, 2.5 MHz gain-bandwidth product, rail-to-rail input and output stages, and e-trim offset adjustment. The 0.25 uV/°C typical input-offset drift helps preserve accuracy as an instrument enclosure changes temperature. Low input bias current also reduces error when the amplifier interfaces with high-impedance sensors.
The OPA191 architecture targets precision rather than high-speed signaling. Its 2.5 MHz bandwidth supports feedback networks and instrumentation signals in the kilohertz range, while the 36 V capability allows operation from higher-voltage industrial supplies without a separate low-voltage translator. The e-trim CMOS design also supports low-power operation when continuous monitoring is more important than wideband performance.
Typical uses include current-loop monitoring, 4-20 mA receiver front ends, precision bridge and sensor amplification, high-voltage measurement buffers, and low-power industrial signal-conditioning modules. The SOIC-8 package makes the device straightforward to place on conventional through-hole and mixed-technology boards.
When designing around the OPA191ID, confirm the input common-mode range at the actual supply voltage and load current. Place the feedback components close to the amplifier pins, keep sensitive input traces away from switching nodes, and account for input-bias-current error when driving very high source impedances.
This page organizes the OPA191ID specifications, application guidance, package details, and available family alternatives into an engineering-focused reference that helps shorten component selection and board-design time.
Alternativas drop-in para OPA191ID — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com OPA191ID (mesmo formato e footprint) — diferindo em Gain-Bandwidth Product, Product Type, Package, Output Swing, Amplifier Type.
OPA192ID
✅ Drop-In ⚠️ Especificações não verificadasConsulte o preço
Ver ficha técnica →OPA197ID
✅ Drop-InConsulte o preço
Ver ficha técnica →OPA196ID
✅ Drop-In ⚠️ Especificações não verificadasConsulte o preço
Ver ficha técnica →OPA191ID Classificações máximas e características elétricas
| Product Type | Precision operational amplifier |
| Amplifier Count | 1 circuit |
| Maximum Supply Voltage | 36 V |
| Technology | e-trim CMOS |
| Rail-to-Rail Input | Yes |
| Rail-to-Rail Output | Yes |
| Gain-Bandwidth Product | 2.5 MHz |
| Corrente de repouso | 0.14 mA |
| Input Offset Drift | 0.25 uV/°C typical |
| Encapsulamento | 8-pin SOIC |
| Tipo de montagem | Surface mount |
Configuração de pinos do OPA191ID
| Pino 1 | OUT — Amplifier output |
| Pino 2 | V- — Negative supply connection |
| Pino 3 | IN+ — Noninverting input |
| Pino 4 | IN- — Inverting input |
| Pino 5 | NC — Not connected |
| Pino 6 | NC — Not connected |
| Pino 7 | V+ — Positive supply connection |
| Pino 8 | NC — Not connected |
Aplicações típicas
OPA191ID é adequado para 6 aplicaçãos: 24 V Industrial Sensor Conditioning, 4-20 mA Receiver Front End, Precision Bridge Amplification, High-Voltage Measurement Buffer, Low-Power Environmental Monitoring, Precision Audio and Instrumentation Buffer.
24 V Industrial Sensor Conditioning
The OPA191ID fits 24 V industrial sensor-conditioning modules because its 36 V maximum supply tolerates the rail while its 0.14 mA quiescent current limits continuous overhead. Place the amplifier near the sensor connector and condition the input before long PCB traces accumulate noise. The 0.25 uV/°C typical input-offset drift is particularly useful when the enclosure temperature changes during a production test. Verify the common-mode range at 24 V and add input protection for surge or overvoltage events.
Recomendado
4-20 mA Receiver Front End
A 4-20 mA receiver can use the OPA191ID to amplify the voltage produced by a current-sense resistor when the available supply supports the input range. Its low input bias current reduces measurement error with high-value sense resistors, and the 2.5 MHz gain-bandwidth product is more than adequate for the slow industrial current loop. Keep the sense resistor close to the amplifier input and place the feedback resistor directly at the output pin to minimize parasitic pickup.
Recomendado
Precision Bridge Amplification
The OPA191ID is suitable as the amplifier in a resistance bridge or strain-gauge front end where offset drift directly affects the result. The 0.25 uV/°C typical input-offset drift and low bias current preserve accuracy as temperature and source impedance change. Operate it with balanced resistive networks and keep input traces short, guarded, and away from regulators and digital switching nodes. Confirm the bridge excitation voltage against the amplifier input common-mode limits.
Recomendado
High-Voltage Measurement Buffer
The OPA191ID can buffer divider outputs in high-voltage measurement equipment because its 36 V supply rating accommodates 24 V industrial buses and larger headroom. Rail-to-rail input and output stages help preserve signal range near the usable supply limits. Divider impedance should be low enough that input bias current produces less error than the measurement budget. Verify both common-mode range and output swing, since absolute supply capability does not guarantee full rail-to-rail operation at every load.
Recomendado
Low-Power Environmental Monitoring
Battery-operated or solar-powered environmental monitors benefit from the OPA191ID because its 0.14 mA typical quiescent current is low for a precision amplifier with a 36 V supply rating. The device can condition slow temperature, humidity, or gas-sensor outputs continuously without dominating the standby budget. Use a regulator with low quiescent current, provide local bypass capacitance, and disable unused analog stages through their own supply domains when possible. The 2.5 MHz bandwidth is more than sufficient for sensor signals below the kilohertz range.
Recomendado
Precision Audio and Instrumentation Buffer
The OPA191ID can serve as a stable DC buffer in instrumentation and low-frequency audio paths where offset drift matters more than wideband slew performance. Its rail-to-rail input and output operation supports single-supply designs, while the 2.5 MHz gain-bandwidth product provides useful margin for audio-band and measurement signals. Keep the gain at unity or low closed-loop gain where stability matters, and place output-load and feedback components close to the device to reduce parasitic oscillation risk.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para OPA191ID — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | OPA192ID | OPA197ID | OPA196ID |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Amplifier Count | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
Principais diferenciais
- Lower-bandwidth precision option suited to slow instrumentation signals (vs OPA192ID)
- High-voltage precision capability with low standby current (vs OPA197ID)
- Same-package family alternatives simplify board evaluation (vs OPA196ID)
Notas de projeto
A 36 V maximum supply rating does not mean that every input may swing to 36 V under all conditions. Check the operating common-mode range at the actual supply voltage, load current, and junction temperature before connecting the input to a high-voltage source. For industrial inputs, place series resistance and appropriately rated clamp protection ahead of pins 3 and 4, and connect the amplifier ground directly to the analog return path.
Route the noninverting and inverting inputs as short, matched traces and place the feedback network close to pins 3, 4, and 1. Keep the amplifier ground connection free of switching-return currents, and place local supply bypass capacitance adjacent to pins 2 and 7. These steps reduce thermally induced offset errors, parasitic feedback, and coupling from adjacent digital or power-converter circuitry.
Estimated quiescent dissipation at a 36 V supply and 0.14 mA quiescent current is 5.04 mW before output-load current is added. This is an arithmetic estimate using the published supply limit and typical quiescent current, not a maximum-power rating. Actual dissipation, junction temperature, and supply-current limits must be evaluated at the real supply voltage, load, and ambient temperature.
The 2.5 MHz gain-bandwidth product is appropriate for slow instrumentation and feedback-control signals, but it does not imply high-speed transient performance. Check the gain-bandwidth product against the closed-loop gain, and add local compensation or isolation when driving capacitive loads. For precision measurements, favor low-noise reference networks and avoid placing resistive dividers directly at high-impedance inputs when bias-current error dominates the budget.
Informações de conformidade