OPA191ID - 36V Low-Power Precision CMOS Op Amp | Texas Instruments
MPN: OPA191ID ✓ 啟用中OPA191ID 概覽
A CMOS precision operational amplifier is an analog building block that amplifies small voltage differences while operating close to its supply rails. The OPA191 belongs to the operational amplifier hierarchy, where precision amplifiers are used to preserve low-level sensor information, minimize offset error, and drive measurement or control stages accurately. Rail-to-rail input and output operation extends the usable common-mode and output range toward the supply limits.
Key characteristics include a maximum 36 V supply, low quiescent current of 0.14 mA, 2.5 MHz gain-bandwidth product, rail-to-rail input and output stages, and e-trim offset adjustment. The 0.25 uV/°C typical input-offset drift helps preserve accuracy as an instrument enclosure changes temperature. Low input bias current also reduces error when the amplifier interfaces with high-impedance sensors.
The OPA191 architecture targets precision rather than high-speed signaling. Its 2.5 MHz bandwidth supports feedback networks and instrumentation signals in the kilohertz range, while the 36 V capability allows operation from higher-voltage industrial supplies without a separate low-voltage translator. The e-trim CMOS design also supports low-power operation when continuous monitoring is more important than wideband performance.
Typical uses include current-loop monitoring, 4-20 mA receiver front ends, precision bridge and sensor amplification, high-voltage measurement buffers, and low-power industrial signal-conditioning modules. The SOIC-8 package makes the device straightforward to place on conventional through-hole and mixed-technology boards.
When designing around the OPA191ID, confirm the input common-mode range at the actual supply voltage and load current. Place the feedback components close to the amplifier pins, keep sensitive input traces away from switching nodes, and account for input-bias-current error when driving very high source impedances.
This page organizes the OPA191ID specifications, application guidance, package details, and available family alternatives into an engineering-focused reference that helps shorten component selection and board-design time.
直接替換替代品,適用於 OPA191ID — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: OPA191ID (相同外形與佔位) — 差異在於 Gain-Bandwidth Product, Product Type, Package, Output Swing, Amplifier Type.
OPA192ID
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →OPA191ID 最大額定值與電氣特性
| Product Type | Precision operational amplifier |
| Amplifier Count | 1 circuit |
| Maximum Supply Voltage | 36 V |
| Technology | e-trim CMOS |
| Rail-to-Rail Input | Yes |
| Rail-to-Rail Output | Yes |
| Gain-Bandwidth Product | 2.5 MHz |
| 靜態電流 | 0.14 mA |
| Input Offset Drift | 0.25 uV/°C typical |
| 封裝 | 8-pin SOIC |
| 安裝類型 | Surface mount |
OPA191ID 腳位配置
| 腳位 1 | OUT — Amplifier output |
| 腳位 2 | V- — Negative supply connection |
| 腳位 3 | IN+ — Noninverting input |
| 腳位 4 | IN- — Inverting input |
| 腳位 5 | NC — Not connected |
| 腳位 6 | NC — Not connected |
| 腳位 7 | V+ — Positive supply connection |
| 腳位 8 | NC — Not connected |
典型應用
OPA191ID 適用於 6 應用s: 24 V Industrial Sensor Conditioning, 4-20 mA Receiver Front End, Precision Bridge Amplification, High-Voltage Measurement Buffer, Low-Power Environmental Monitoring, Precision Audio and Instrumentation Buffer.
24 V Industrial Sensor Conditioning
The OPA191ID fits 24 V industrial sensor-conditioning modules because its 36 V maximum supply tolerates the rail while its 0.14 mA quiescent current limits continuous overhead. Place the amplifier near the sensor connector and condition the input before long PCB traces accumulate noise. The 0.25 uV/°C typical input-offset drift is particularly useful when the enclosure temperature changes during a production test. Verify the common-mode range at 24 V and add input protection for surge or overvoltage events.
推薦
4-20 mA Receiver Front End
A 4-20 mA receiver can use the OPA191ID to amplify the voltage produced by a current-sense resistor when the available supply supports the input range. Its low input bias current reduces measurement error with high-value sense resistors, and the 2.5 MHz gain-bandwidth product is more than adequate for the slow industrial current loop. Keep the sense resistor close to the amplifier input and place the feedback resistor directly at the output pin to minimize parasitic pickup.
推薦
Precision Bridge Amplification
The OPA191ID is suitable as the amplifier in a resistance bridge or strain-gauge front end where offset drift directly affects the result. The 0.25 uV/°C typical input-offset drift and low bias current preserve accuracy as temperature and source impedance change. Operate it with balanced resistive networks and keep input traces short, guarded, and away from regulators and digital switching nodes. Confirm the bridge excitation voltage against the amplifier input common-mode limits.
推薦
High-Voltage Measurement Buffer
The OPA191ID can buffer divider outputs in high-voltage measurement equipment because its 36 V supply rating accommodates 24 V industrial buses and larger headroom. Rail-to-rail input and output stages help preserve signal range near the usable supply limits. Divider impedance should be low enough that input bias current produces less error than the measurement budget. Verify both common-mode range and output swing, since absolute supply capability does not guarantee full rail-to-rail operation at every load.
推薦
Low-Power Environmental Monitoring
Battery-operated or solar-powered environmental monitors benefit from the OPA191ID because its 0.14 mA typical quiescent current is low for a precision amplifier with a 36 V supply rating. The device can condition slow temperature, humidity, or gas-sensor outputs continuously without dominating the standby budget. Use a regulator with low quiescent current, provide local bypass capacitance, and disable unused analog stages through their own supply domains when possible. The 2.5 MHz bandwidth is more than sufficient for sensor signals below the kilohertz range.
推薦
Precision Audio and Instrumentation Buffer
The OPA191ID can serve as a stable DC buffer in instrumentation and low-frequency audio paths where offset drift matters more than wideband slew performance. Its rail-to-rail input and output operation supports single-supply designs, while the 2.5 MHz gain-bandwidth product provides useful margin for audio-band and measurement signals. Keep the gain at unity or low closed-loop gain where stability matters, and place output-load and feedback components close to the device to reduce parasitic oscillation risk.
推薦
推薦產品摘要
工程參考資料,適用於 OPA191ID — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | OPA192ID | OPA197ID | OPA196ID |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Amplifier Count | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
主要差異化特點
- Lower-bandwidth precision option suited to slow instrumentation signals (對比OPA192ID)
- High-voltage precision capability with low standby current (對比OPA197ID)
- Same-package family alternatives simplify board evaluation (對比OPA196ID)
設計說明
A 36 V maximum supply rating does not mean that every input may swing to 36 V under all conditions. Check the operating common-mode range at the actual supply voltage, load current, and junction temperature before connecting the input to a high-voltage source. For industrial inputs, place series resistance and appropriately rated clamp protection ahead of pins 3 and 4, and connect the amplifier ground directly to the analog return path.
Route the noninverting and inverting inputs as short, matched traces and place the feedback network close to pins 3, 4, and 1. Keep the amplifier ground connection free of switching-return currents, and place local supply bypass capacitance adjacent to pins 2 and 7. These steps reduce thermally induced offset errors, parasitic feedback, and coupling from adjacent digital or power-converter circuitry.
Estimated quiescent dissipation at a 36 V supply and 0.14 mA quiescent current is 5.04 mW before output-load current is added. This is an arithmetic estimate using the published supply limit and typical quiescent current, not a maximum-power rating. Actual dissipation, junction temperature, and supply-current limits must be evaluated at the real supply voltage, load, and ambient temperature.
The 2.5 MHz gain-bandwidth product is appropriate for slow instrumentation and feedback-control signals, but it does not imply high-speed transient performance. Check the gain-bandwidth product against the closed-loop gain, and add local compensation or isolation when driving capacitive loads. For precision measurements, favor low-noise reference networks and avoid placing resistive dividers directly at high-impedance inputs when bias-current error dominates the budget.
合規資訊