Товары (44.000+)

INA163UA - Low-Noise Instrumentation Amplifier | Texas Instruments
INA163UA

INA163UA - Low-Noise Instrumentation Amplifier | Texas Instruments

Texas Instruments INA163UA is a monolithic, low-noise, low-distortion instrumentation amplifier in a 14-pin SOIC package. The device uses current-feedback circuitry to provide wide bandwidth and strong dynamic response across its gain range. Its instrumentation-amplifier architecture supports differential input measurement while preserving low-noise and low-distortion performance for precision signal conditioning. The INA163UA is designed for low-level audio signals, including balanced low-impedance microphones, as well as industrial, instrumentation, and medical applications where signal integrity and measurement accuracy are important. An instrumentation amplifier is a specialized analog amplifier that provides differential gain, high input impedance, and accurate common-mode rejection. The INA163UA combines these functions in a single IC, simplifying signal-chain design when a sensor or balanced source must be amplified before measurement, conversion, or audio processing. Its current-feedback approach differentiates it from voltage-feedback amplifiers and is particularly useful where bandwidth and dynamic response need to remain strong over multiple gain settings. The principal benefit of the INA163UA is low-noise signal conditioning in demanding analog systems. Low noise preserves small-signal information and can improve the usable dynamic range of downstream converters, audio equipment, and laboratory instruments. Low distortion helps maintain signal integrity when the input contains high-quality content and the amplifier operates at practical signal levels. The device is also suitable for applications that require a compact solution rather than a discrete three-amplifier instrumentation-amplifier implementation. Typical uses include balanced microphone preamplification, audio signal conditioning, industrial measurement systems, medical instrumentation, and low-level sensor interfaces. The 14-pin SOIC package supports conventional surface-mount assembly and provides a practical upgrade path when a design requires low noise and low distortion in a compact analog IC. Designers should use the manufacturer datasheet for the complete electrical limits, gain configuration, pin assignments, recommended operating conditions, and application circuit. PCB layout should keep input and feedback connections short, maintain a clean ground reference, and place compensation or filtering components close to their associated pins. This page combines manufacturer information, distributor references, package details, practical design guidance, and drop-in alternative evaluation for faster component selection.

Запрос цены Контакты
INA166UA - G=2000 Low-Noise Instrumentation Amplifier | TI
INA166UA

INA166UA - G=2000 Low-Noise Instrumentation Amplifier | TI

The Texas Instruments INA166UA is a single-circuit, internally set G=2000 instrumentation amplifier with a 450 kHz -3 dB bandwidth, 15 V/µs slew rate, 50 µV input offset voltage, and 2.5 µA input bias current in a 14-pin SOIC (D) package. The device uses current-feedback circuitry to provide low noise, low distortion, wide bandwidth, and strong dynamic response when amplifying very small differential signals. An instrumentation amplifier is a differential-input amplifier optimized for precision signal conditioning. It combines high input impedance, accurate differential gain, and common-mode rejection into one device, reducing the need for several precision operational amplifiers and matched resistors. The INA166 belongs to the broader amplifier IC hierarchy and is commonly used where sensors and transducers produce small outputs that must be measured accurately in the presence of larger common-mode voltages. The INA166's fixed gain of 2000 increases a small differential input by a factor of 2000, making it useful for low-level microphone, hydrophone, industrial transducer, and medical-instrumentation signals. Its 450 kHz -3 dB bandwidth provides substantially more bandwidth than a traditional low-noise precision amplifier with a narrow frequency response. The 15 V/µs slew rate supports rapid signal transitions, while the 2.5 µA input bias current helps preserve accuracy with high-impedance sources. The current-feedback architecture differentiates the INA166 from voltage-feedback instrumentation amplifiers that depend on a closed-loop gain resistor. Because its gain is internally set, the circuit does not require an external gain-setting resistor, reducing component count and avoiding sensitivity to external gain-resistor tolerance. The manufacturer describes the device as a very low-noise, low-distortion monolithic instrumentation amplifier intended for low-level signals. Typical uses include precision microphone preamplification, hydrophone signal chains, industrial process-control inputs, bridge-sensor interfaces, and medical monitoring equipment. In each case, the differential input can reject common-mode interference while the fixed high gain converts a millivolt-level sensor output into a range suitable for an ADC or subsequent signal-processing stage. Designers should verify the signal bandwidth and output swing against the datasheet limits, place input and feedback connections for low noise, and provide stable bypassing on the supply pins. The wide bandwidth and slew rate can excite output-stage distortion if the output signal approaches the available output-voltage range, so the gain and sensor bandwidth should be considered together rather than independently. This product record combines the verified manufacturer and distributor data for the INA166UA with lifecycle information, pricing context, package details, application guidance, and a conservative replacement analysis. It distinguishes verified drop-in candidates from related ordering variants so engineers can assess PCB and supply-chain decisions without confusing a different gain option with an exact functional replacement.

Запрос цены Контакты
INA181A1QDBVRQ1 - 26V AEC-Q100 Bidirectional Current Sense Amp | TI
INA181A1QDBVRQ1

INA181A1QDBVRQ1 - 26V AEC-Q100 Bidirectional Current Sense Amp | TI

The Texas Instruments INA181A1QDBVRQ1 is an AEC-Q100-qualified, 26V bidirectional, low- and high-side voltage-output current-sense amplifier with a fixed gain of 20 V/V, housed in a 6-pin SOT-23 (DBV) package. It operates across a -0.2V to 26V common-mode input range, supports a 350 kHz bandwidth, and draws 195 uA typical quiescent current. The A1 gain variant delivers 20 V/V output scaling, making it suitable for low-current shunt monitoring in tight PCB areas. A current-sense amplifier is an analog IC that measures voltage drop across a shunt resistor placed in series with a load, producing a ground-referenced output proportional to load current. Current-sense amplifiers sit in the broader hierarchy of signal-chain ICs -> amplifiers -> instrumentation amplifiers -> current-sense amplifiers, and they are essential building blocks of any power-management system that requires accurate real-time current telemetry for protection, regulation, or efficiency optimization. Key features include bidirectional sensing (single part supports both charge and discharge current on battery rails), 350 kHz bandwidth for fast transient response, rail-to-rail output swing for maximum dynamic range with low supply headroom, and AEC-Q100 Grade 1 qualification with an operating temperature range of -40C to +125C for under-hood automotive deployment. The device integrates a precision thin-film gain resistor network that eliminates external gain-setting components. Internally, the INA181A1QDBVRQ1 uses a chopped-input bipolar front-end with delta-sigma offset correction, achieving 100 uV maximum offset and 1 uV/C typical drift. This architecture rejects 50/60 Hz line-coupled noise and PSRR-induced errors from upstream switching converters, enabling accurate measurement on noisy automotive buses such as 12V battery feeds. Typical applications include automotive body electronics (lighting load monitoring, seat heater current sense), USB Type-C VBUS current monitoring, motor drive H-bridge phase current feedback, battery management systems for e-bikes and power tools, and solar MPPT input-side current sensing. The wide common-mode range handles inductive load transients and load-dump pulses found in 12V/24V automotive systems. When designing with this device, ensure the input pins remain within the absolute maximum ratings even during transients; a small differential RC filter between the shunt and the IN+/IN- pins limits input-stage overdrive. Use a 4-layer PCB with a low-impedance ground pour to avoid ground bounce corrupting the high-side measurement. This page synthesizes distributor pricing, drop-in SOT-23-6 alternatives, and practical design notes not found in the manufacturer datasheet alone.

Запрос цены Контакты
INA186A3IDCKR - 40V Bidirectional Current Sense Amp | TI
INA186A3IDCKR

INA186A3IDCKR - 40V Bidirectional Current Sense Amp | TI

The Texas Instruments INA186A3IDCKR is a 40 V, bidirectional, high-precision, low-power, zero-drift current-sense amplifier in a 6-pin SC-70 (DCK) package. The A3 gain variant sets the fixed internal gain to 100 V/V, and the device accepts common-mode voltages from -0.2 V to +40 V independently of the supply rail. A current-sense amplifier (CSA, also called a current-shunt monitor) is an analog IC that measures the small differential voltage developed across a shunt resistor in series with a load, and converts it to a ground-referenced output voltage proportional to load current. CSAs sit in the signal-chain hierarchy: shunt resistor -> current-sense amplifier -> ADC / MCU / comparator, and they are essential building blocks in the power-management sub-system for accurate telemetry and protection. Key features include a low offset voltage enabled by the zero-drift chopper architecture, picoamp-level input bias current that supports large shunt values for microamp measurements, a low quiescent current (typically tens of microamps) suitable for always-on battery monitoring, an integrated ENABLE pin for power gating, and rail-to-rail output swing for full-scale ADC input utilization. The A3 fixed gain of 100 V/V provides 20 mV/V sensitivity. The architecture combines a precision chopper-stabilized input stage with an internal gain-setting resistor network, eliminating the external gain resistors required by discrete difference-amplifier implementations. The high common-mode rejection and picoamp bias allow designers to use larger sense resistors for better signal-to-noise without measurable loading error. Typical applications include battery-cell monitoring in battery management systems (BMS), USB-C current advertisement and overcurrent protection, motor-phase current sensing in BLDC drivers, solar MPPT input-current telemetry, and precision 24 V industrial-sensor rails. Design tip: pick the A1/A2/A3/A4/A5 gain variant by matching your full-scale shunt voltage to the ADC input range; keep the shunt Kelvin-connected to the IN+/IN- pins and use a 4-wire layout to preserve CMRR at high dV/dt. This page consolidates authorized-distributor pricing for the INA186A3IDCKR, true drop-in alternatives in the same SC-70-6 footprint, and PCB design guidance that goes beyond the manufacturer datasheet.

Запрос цены Контакты
INA188ID - 36V Zero-Drift Instrumentation Amplifier | Texas Instruments
INA188ID

INA188ID - 36V Zero-Drift Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA188ID is a single-channel, 36 V zero-drift instrumentation amplifier with rail-to-rail output, selectable gain from 1 to 1000, and an 8-pin SOIC package. It provides a gain of 1 + (50 kΩ/RG), allowing one external resistor to set the gain while preserving the established instrumentation-amplifier connection. According to the Texas Instruments product page, the INA188ID is intended for precision signal measurement and sensor conditioning, including temperature sensing and bridge-based measurements, and is specified over a -40°C to +125°C temperature range. An instrumentation amplifier is a specialized differential amplifier that measures a small voltage difference between two inputs while offering high input impedance, common-mode rejection, and gain accuracy. The INA188 belongs to the zero-drift instrumentation-amplifier family, a subtype of precision analog amplifiers used for sensor interfaces, current measurement, biomedical instrumentation, and industrial process control. Its internal auto-zeroing techniques reduce offset voltage and offset drift, making it more suitable for slowly varying precision signals than a conventional amplifier whose offset moves with temperature. Key features include a 36 V maximum supply voltage, rail-to-rail output operation, gains from 1 to 1000, and a maximum input offset voltage of 55 µV as reported by the comparative distributor data. The reference pin supports output level shifting in single-supply systems and offset calibration. A single gain-setting resistor simplifies design-in, while the zero-drift architecture addresses offset stability in temperature, bridge, and slow-current-measurement systems. The 8-pin SOIC package also supports conventional surface-mount assembly. The gain relationship G = 1 + (50 kΩ/RG) allows the sensor interface to be scaled without an active gain network. For example, a 1 kΩ gain resistor produces a nominal gain of 51, while a 50 Ω resistor produces a nominal gain of 1001 before rounding and standard gain-error considerations are applied. The reference input provides an additional analog node for systems that cannot shift their output entirely in the analog domain. Designers should preserve the instrumentation-amplifier grounding and input-common-mode requirements when evaluating usable signal range. Typical uses include strain-gauge and load-cell bridges, RTD and thermocouple signal conditioning, precision current-shunt measurements, battery monitoring, and low-level sensor acquisition. The INA188ID is particularly appropriate when low offset and low drift matter more than wideband response. In bridge systems, its differential input arrangement and adjustable gain can amplify the small bridge imbalance while limiting sensitivity to common-mode voltage. In battery-powered equipment, the reference pin can place the output within the usable range of a single-supply analog-to-digital converter. The primary design consideration is ensuring that input and output common-mode voltages remain inside the device's operating limits at every gain and supply condition. Gain-set resistor tolerance contributes directly to gain accuracy, so precision resistors may be required for calibrated measurements. Input filtering, source impedance, reference-pin routing, and exposed-area thermal management should also be evaluated before production release. This product page consolidates manufacturer specifications, verified distributor pricing, package details, comparison data, and practical design guidance. It also distinguishes verified drop-in candidates from broader functional alternatives so engineers can assess footprint, gain-setting, voltage-range, and precision differences before changing a production design.

Запрос цены Контакты
INA188IDR - 36V Zero-Drift Instrumentation Amplifier | Texas Instruments (Tape & Reel)
INA188IDR

INA188IDR - 36V Zero-Drift Instrumentation Amplifier | Texas Instruments (Tape & Reel)

The Texas Instruments INA188IDR is a single-channel, 36 V zero-drift instrumentation amplifier with rail-to-rail output, selectable gain from 1 to 1000, and an 8-pin SOIC package. It provides a gain of 1 + (50 kΩ/RG), allowing one external resistor to set the gain while preserving the established instrumentation-amplifier connection. According to the Texas Instruments product page, the INA188IDR is intended for precision signal measurement and sensor conditioning, including temperature sensing and bridge-based measurements, and is specified over a -40°C to +125°C temperature range. An instrumentation amplifier is a specialized differential amplifier that measures a small voltage difference between two inputs while offering high input impedance, common-mode rejection, and gain accuracy. The INA188 belongs to the zero-drift instrumentation-amplifier family, a subtype of precision analog amplifiers used for sensor interfaces, current measurement, biomedical instrumentation, and industrial process control. Its internal auto-zeroing techniques reduce offset voltage and offset drift, making it more suitable for slowly varying precision signals than a conventional amplifier whose offset moves with temperature. Key features include a 36 V maximum supply voltage, rail-to-rail output operation, gains from 1 to 1000, and a maximum input offset voltage of 55 µV as reported by the comparative distributor data. The reference pin supports output level shifting in single-supply systems and offset calibration. A single gain-setting resistor simplifies design-in, while the zero-drift architecture addresses offset stability in temperature, bridge, and slow-current-measurement systems. The 8-pin SOIC package also supports conventional surface-mount assembly. The gain relationship G = 1 + (50 kΩ/RG) allows the sensor interface to be scaled without an active gain network. For example, a 1 kΩ gain resistor produces a nominal gain of 51, while a 50 Ω resistor produces a nominal gain of 1001 before rounding and standard gain-error considerations are applied. The reference input provides an additional analog node for systems that cannot shift their output entirely in the analog domain. Designers should preserve the instrumentation-amplifier grounding and input-common-mode requirements when evaluating usable signal range. Typical uses include strain-gauge and load-cell bridges, RTD and thermocouple signal conditioning, precision current-shunt measurements, battery monitoring, and low-level sensor acquisition. The INA188IDR is particularly appropriate when low offset and low drift matter more than wideband response. In bridge systems, its differential input arrangement and adjustable gain can amplify the small bridge imbalance while limiting sensitivity to common-mode voltage. In battery-powered equipment, the reference pin can place the output within the usable range of a single-supply analog-to-digital converter. The primary design consideration is ensuring that input and output common-mode voltages remain inside the device's operating limits at every gain and supply condition. Gain-set resistor tolerance contributes directly to gain accuracy, so precision resistors may be required for calibrated measurements. Input filtering, source impedance, reference-pin routing, and exposed-area thermal management should also be evaluated before production release. This product page consolidates manufacturer specifications, verified distributor pricing, package details, comparison data, and practical design guidance. It also distinguishes verified drop-in candidates from broader functional alternatives so engineers can assess footprint, gain-setting, voltage-range, and precision differences before changing a production design.

Запрос цены Контакты
INA188IDRJR - 36V Zero-Drift Instrumentation Amplifier | Texas Instruments
INA188IDRJR

INA188IDRJR - 36V Zero-Drift Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA188IDRJR is a precision, zero-drift, rail-to-rail output, high-voltage instrumentation amplifier housed in an 8-pin SON (4x4 mm) package with an exposed thermal pad. It delivers 55 uV (max) input offset voltage, 0.2 uV/°C (max) input offset drift, and 104 dB (min) CMRR at gains of 10 or higher. The part operates from a wide 4 V to 36 V single supply (or ±2 V to ±18 V dual supply), accepting input signals up to the rails while swinging its output rail-to-rail. An instrumentation amplifier (INA) is a specialized differential amplifier designed for precise amplification of small differential signals in the presence of large common-mode voltages. Compared to a general-purpose op-amp built from three discrete amplifiers, an INA integrates the input buffer, gain stage, and difference amplifier into one laser-trimmed silicon block, achieving far higher common-mode rejection ratio (CMRR), lower offset drift, and far simpler single-resistor gain setting. INAs sit hierarchically inside the sensor signal-chain / analog front-end / mixed-signal IC family and are the building block of choice for bridge sensors, thermocouples, RTDs, and biomedical instrumentation. Key features include 12 nV/√Hz input voltage noise density at 1 kHz, 0.25 uVPP (0.1 Hz to 10 Hz) low-frequency noise, an industry-standard gain equation G = 1 + (50 kΩ / RG) settable from 1 V/V to 1000 V/V with a single external resistor, and a reference pin for level-shifting in single-supply operation or for offset calibration. The integrated zero-drift (chopper-stabilized) topology continuously nulls its own 1/f noise and offset, eliminating the need for periodic user calibration. The INA188 uses TI's proprietary auto-zero / chopper-stabilized architecture combined with thin-film resistor networks for the gain-setting feedback. This delivers near-ideal DC accuracy without the discrete capacitor or clock-noise artifacts of older chopper designs, while the 4 mm x 4 mm SON package exposes its complementary efficiency rating to standard SOIC-8 boards through its thermal pad. Typical applications include weigh scales and bridge sensor signal conditioning, thermocouple and RTD temperature measurement, medical instrumentation (ECG, EEG front ends), industrial process controls, and strain-gauge amplifier chains. The wide 4 V to 36 V supply range makes it a direct fit for industrial 24 V bus systems. When designing, place the gain-setting resistor close to the RG pins and add a 0.1 uF supply bypass capacitor on each supply pin; the exposed thermal pad must be soldered to a copper pad for rated thermal performance. This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet.

Запрос цены Контакты
INA190A1IRSWR - 40V Picoamp Current Sense Amp | TI
INA190A1IRSWR

INA190A1IRSWR - 40V Picoamp Current Sense Amp | TI

The Texas Instruments INA190A1IRSWR is a 40V bidirectional, zero-drift current sense amplifier (current-shunt monitor) with picoampere input bias current and an enable pin, housed in a 10-pin UQFN (RSV, 1.8 mm x 1.4 mm) package. It senses voltage drops across shunt resistors at common-mode voltages from -0.2 V to +40 V, independent of its 1.8 V-class low supply. A current sense amplifier is a specialized difference amplifier that measures the small voltage generated across a shunt resistor and converts it into a ground-referenced output signal. Within the power-management hierarchy, it sits between the shunt and an ADC or comparator, enabling precise current measurement for feedback, protection, and telemetry in systems from battery packs to industrial drives. Key features of the INA190 family include a very wide input common-mode range (-0.2 V to 40 V) that tolerates inductive kickback and reverse-battery events, ultra-low input bias current in the picoampere range that permits very small shunt resistors, and zero-drift architecture for near-DC accuracy. The INA190A1IRSWR offers an ENABLE pin for power-cycling in battery-powered designs and operates across -40C to +125C. Technically, the device uses a zero-drift (auto-zeroing) topology that eliminates offset drift over time and temperature, achieving precision far beyond conventional CMOS amplifiers. The low bias current allows shunts in the milliohm range without significant self-heating error, while the wide common-mode range permits high-side, low-side, and bidirectional sensing with a single supply. The voltage-output interface connects directly to ADCs without external conditioning. Typical applications include overcurrent protection in USB and battery-powered systems, precision current telemetry in notebooks and IoT devices, and closed-loop current feedback in industrial controls, where low shunt losses and accuracy at low supply voltages are essential. Design consideration: because the part supports a 1.8 V supply domain, verify the output swing and reference pin drive against your ADC input range to avoid clipping near the rails. This page synthesizes distributor pricing, drop-in alternatives, pinout guidance, and practical design notes not found in the manufacturer datasheet.

Запрос цены Контакты
INA190A2IDDFR - 40V Bidirectional Current Sense Amp | TI
INA190A2IDDFR

INA190A2IDDFR - 40V Bidirectional Current Sense Amp | TI

The Texas Instruments INA190A2IDDFR is a 40-V bidirectional, ultra-precise current-sense amplifier with picoamp-level input bias current and an integrated ENABLE pin, offered in an 8-pin TSOT-23 (DDF) package. The A2 gain option delivers a fixed 50 V/V transimpedance, supporting common-mode voltages from -0.2 V to +40 V independent of the supply rail. The zero-drift chopper-stabilized architecture keeps input offset voltage below 15 uV (typical 5 uV) and offset drift below 0.1 uV/C, which translates directly into accurate microamp-range current measurements when paired with a small shunt. A current-sense amplifier is an analog building block that converts a small differential voltage developed across a shunt resistor into a ground-referenced output voltage proportional to load current. The INA190 family belongs to the current-sense amplifier / instrumentation amplifier / signal-chain IC / analog IC taxonomy, sitting one level below general-purpose op-amps because it integrates a precision gain network and reference-stable input stage optimized for high common-mode rejection at high voltages. This category plays a central role in modern power management, where system optimization, telemetry, and closed-loop feedback demand accurate, low-latency current data. Key features include a 1.8-V to 5.5-V supply range, 65 uA typical quiescent current, 60 V common-mode transient immunity, and 40 kHz small-signal bandwidth. Output swings rail-to-rail and the device supports low-side, high-side, and bidirectional topologies, eliminating external protection circuitry in 12-V, 24-V, and 48-V industrial buses. The picoamp input bias current allows sense resistors up to tens of kilo-ohms, which is critical for monitoring sleep-mode current in battery-powered products without degrading accuracy. The zero-drift chopper architecture continuously nulls 1/f noise and thermal drift, yielding effectively DC-stable output over the full -40C to +125C operating range. The internal EN pin lets a microcontroller gate the supply current down to a sub-microamp leakage level, which is essential for always-on battery systems that must periodically wake to perform current sampling. Combined, these characteristics make the INA190A2 one of the lowest-noise, lowest-drift current-sense amplifiers in its class. Typical applications include USB-PD and Type-C cable-compensation, motor-control current loops, solar MPPT input monitors, battery-pack gas-gauging, and point-of-load telemetry in servers and telecom rectifiers. The fixed 50 V/V gain optimizes the part for low-current (sub-amp) measurements where the A1 (25 V/V) is too noisy and the A3 (100 V/V) or A4 (200 V/V) variants sacrifice dynamic range. A key design consideration is the trade-off between shunt resistance and dissipated power: choose a 50 V/V part when the load is typically below 1 A and milliohm shunts are preferred, and place the input capacitor network as close as possible to the IN+ and IN- pins to reject high-frequency transients on the common-mode bus. This page synthesizes distributor pricing, drop-in alternatives in the same TSOT-23-8 footprint, and practical design notes that go beyond the manufacturer datasheet to help engineers select, source, and qualify the INA190A2IDDFR for their next precision current-monitoring design.

Запрос цены Контакты
INA210BQDCKRQ1 - AEC-Q100 26V Bi-Directional Current Sense Amp | TI
INA210BQDCKRQ1

INA210BQDCKRQ1 - AEC-Q100 26V Bi-Directional Current Sense Amp | TI

The Texas Instruments INA210BQDCKRQ1 is an AEC-Q100 qualified, 26 V, bi-directional, high-precision current sense amplifier (also called a current-shunt monitor) housed in a 6-pin SOT-SC70 (DCK) package. It senses voltage drops across shunt resistors at common-mode voltages from -0.3 V to 26 V, independent of the supply voltage, and delivers an analog output proportional to the sensed current with a fixed gain of 200 V/V. A current sense amplifier is a specialized analog building block that converts a small differential voltage developed across a current-sense (shunt) resistor into a ground-referenced, amplified output voltage. It sits in the signal chain between the shunt resistor (placed in series with the load) and the downstream ADC, microcontroller, or comparator, and belongs to the broader hierarchy of instrumentation amplifiers -> operational amplifiers -> analog ICs. Zero-drift chopper-stabilized topology enables the INA210 family to achieve microvolt-level offset and excellent common-mode rejection. Key features include a maximum offset voltage of 35 uV, a gain error of only 0.5 percent (max), and 40 kV/us slew rate, plus a 2.7 V to 26 V supply range with 65 uA typical quiescent current. The device offers bidirectional sensing (REF input allows positive or negative current measurement), operates from -40C to +125C, and integrates EMI filtering plus thermal shutdown. The SC70-6 package occupies roughly 2.1 mm x 1.45 mm of PCB area, ideal for compact automotive modules. The INA210 uses a chopper-stabilized input stage and precision thin-film resistors to achieve gain accuracy and ultra-low offset drift over temperature. Its high common-mode rejection ratio (CMRR) of 140 dB and the ability to operate with the input common-mode above V+ make it tolerant of inductive loads, motor inrush, and 12 V/24 V automotive transients such as load-dump. Typical applications include automotive body electronics (battery management, ECU power monitoring), motor control current loops, solenoid and valve actuation feedback, USB Type-C current advertisement (BC 1.2), and precision 48 V telecom/industrial rails. The combination of AEC-Q100 qualification, wide common-mode range, and small package makes it especially well-suited for safety-relevant automotive systems. When designing with this device, place the shunt resistor close to the input pins to minimize parasitic resistance, use Kelvin connection to the shunt, and add a small RC filter at the output to limit noise bandwidth. Choose the shunt value so that the maximum differential input (Vshunt_max = VSENSE_max / 200) does not exceed the linear input range, accounting for transient overloads. This page synthesizes distributor pricing, same-brand and cross-brand drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone.

Запрос цены Контакты
INA2126P - Dual 36V Micropower Instrumentation Amplifier | Texas Instruments
INA2126P

INA2126P - Dual 36V Micropower Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA2126P is a dual-channel, micropower precision instrumentation amplifier designed for accurate differential-signal acquisition. Each channel uses a two-op-amp architecture and consumes 175 µA of quiescent current, while the device operates from ±1.35 V to ±18 V, equivalent to a 36 V maximum total supply range. The INA2126P provides 250 µV offset performance and is supplied in a 16-pin PDIP package for through-hole PCB designs. An instrumentation amplifier is a specialized analog signal-conditioning IC that amplifies the voltage difference between two inputs while rejecting common-mode interference. The INA2126 family belongs to the instrumentation amplifier hierarchy, which includes differential amplifiers, low-noise analog amplifiers, and broader analog signal-chain ICs. Its differential-input architecture makes it suitable for sensor signals, bridge outputs, and other small-signal measurements where the wanted signal is small relative to an imposed common-mode voltage. The principal features of the INA2126P are its dual-channel configuration, 175 µA per channel quiescent current, 250 µV offset specification, and wide ±1.35 V to ±18 V operating range. Micropower consumption reduces the burden on portable and battery-powered systems, while the wide supply range supports both low-voltage portable instrumentation and higher-voltage industrial measurement systems. The differential architecture also helps preserve signal integrity when the input common-mode voltage is substantially larger than the differential signal being measured. The INA2126 family uses a two-op-amp instrumentation-amplifier topology to provide differential amplification with high input impedance and common-mode rejection. Because the device is intended for precision acquisition rather than high-bandwidth signal processing, designers should use the manufacturer-recommended gain-setting resistor and follow the datasheet layout guidance to minimize gain error and offset contributions. The 16-pin PDIP package favors through-hole prototyping, laboratory instrumentation, and industrial control boards where a surface-mount package is not required. Typical applications include portable sensor acquisition, strain-gauge and bridge excitation systems, battery-powered measurement equipment, industrial process monitoring, medical instrumentation, and low-power data-acquisition systems. In each case, the INA2126P provides a practical way to amplify a differential sensor signal while keeping channel quiescent current at 175 µA. Designers should confirm that input common-mode voltage, output swing, gain, bandwidth, and supply limits satisfy the specific measurement requirements. The primary design consideration is ensuring adequate output headroom and checking the gain-dependent bandwidth and input range. The 250 µV offset specification supports precise measurements, but resistor matching and layout still influence overall system accuracy. Input filtering and guarding can reduce high-frequency interference, while stable reference and excitation arrangements are important for bridge-based sensors. This product page combines the verified Texas Instruments product information, distributor availability references, pricing context, package details, and engineering selection guidance to provide a practical comparison point for engineers evaluating the INA2126P.

Запрос цены Контакты
INA2126PA - Dual 36V Micropower Instrumentation Amplifier | Texas Instruments
INA2126PA

INA2126PA - Dual 36V Micropower Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA2126PA is a dual-channel precision instrumentation amplifier designed for accurate, low-noise differential-signal acquisition. The device operates from a wide ±1.35 V to ±18 V supply range, consumes approximately 175 μA per channel, and provides a 16-pin PDIP package for through-hole PCB designs. Its two-amplifier architecture is intended to amplify small differential signals while rejecting common-mode interference in sensor, measurement, and portable instrumentation systems. An instrumentation amplifier is a specialized amplifier category used for differential measurement. Its internal signal path amplifies the difference between two inputs while providing high common-mode rejection, making it more suitable for bridge sensors, current loops, and low-level analog front ends than a general-purpose operational amplifier. The INA2126 belongs to the INAx126 family of precision instrumentation amplifiers, combining low power consumption with accurate signal conditioning. Key characteristics include a 250 μV offset specification, low quiescent current, a wide operating voltage range, and a bandwidth of approximately 200 kHz according to the product listing. The dual configuration provides two independent amplifier channels in one package, reducing component count on multi-axis or multi-sensor boards. The instrument amplifier category is part of the broader linear amplifier hierarchy and ultimately belongs to the analog integrated-circuit and signal-conditioning ecosystem. The INA2126PA is suitable for portable instrumentation, sensor-interface circuits, battery-powered measurement equipment, industrial process monitoring, and precision data-acquisition systems. Its low 175 μA per-channel current makes it useful when battery life and thermal performance are important. The wide supply range also supports systems operating from low-voltage portable rails or higher-voltage industrial analog rails. Designers should pay attention to input common-mode range, output swing, gain-setting resistor selection, bypass-capacitor placement, and the effects of source impedance when using precision instrumentation amplifiers. The dual package provides an opportunity to place two channels close together, but differential routing must minimize noise pickup and maintain a consistent ground reference. Use the manufacturer datasheet for the complete electrical characteristics and pin configuration before laying out a new PCB. This product page combines the INA2126PA device specifications, sourcing information, verified drop-in alternatives, comparison parameters, and practical design guidance to support faster component selection and implementation.

Запрос цены Контакты
INA2126PG4 - Dual 200 kHz Micropower INA | Texas Instruments
INA2126PG4

INA2126PG4 - Dual 200 kHz Micropower INA | Texas Instruments

The Texas Instruments INA2126PG4 is a dual-channel, micropower precision instrumentation amplifier designed for accurate differential signal acquisition. It operates from ±1.35 V to ±18 V, or 1.35 V to 36 V across the supply range, and provides a bandwidth of 200 kHz. The device combines a two-op-amp instrumentation-amplifier architecture with very low quiescent current of 175 µA per channel, making it suitable for portable measurement systems, industrial sensor interfaces, battery-powered equipment, and low-power data-acquisition designs. The INA2126PG4 is packaged in a 16-pin PDIP package. An instrumentation amplifier is a precision analog signal-conditioning IC that amplifies the difference between two input voltages while rejecting common-mode interference. The INA2126 belongs to the instrumentation-amplifier hierarchy of analog ICs and is designed to provide high input impedance, low offset voltage, and accurate differential gain. Its two-op-amp design provides a practical balance between low power consumption and signal fidelity, making it useful when common-mode noise, source impedance, or limited supply energy restricts simpler amplifier arrangements. The INA2126PG4 is specified with 175 µA per-channel quiescent current, up to 250 µV maximum offset voltage, 83 dB CMRR, and 200 kHz bandwidth according to the Texas Instruments product information. The device also supports a supply voltage from 1.35 V to 36 V, allowing operation from low-voltage portable systems through higher-voltage industrial rails. Its dual-channel configuration permits simultaneous acquisition of two differential signals, reducing the number of separate instrumentation amplifiers required on a measurement board. The two-op-amp architecture is intended for accurate, low-noise differential-signal acquisition. Input bias current is listed as 10 nA in product information, helping preserve accuracy when connected to high-impedance sensors. The 0.4 V/µs slew rate supports amplification of changing sensor signals, while the 200 kHz bandwidth covers many pressure, temperature, strain, and low-frequency industrial measurement applications. The instrumentation-amplifier function converts a small differential input into a larger single-ended signal for an ADC or downstream measurement circuit. Typical uses include portable medical and laboratory instruments, low-power industrial controllers, battery-operated sensor interfaces, bridge and thermocouple signal conditioning, and general-purpose data-acquisition systems. The dual architecture is especially useful when two channels must be acquired at similar signal levels, such as paired strain-gauge or pressure-sensor channels. Design engineers should select external gain and filtering components to match the sensor output, required bandwidth, and input common-mode range. For layout, keep input and feedback components close to the corresponding pins and maintain a symmetric differential signal path. Place decoupling capacitors near the supply pins and route high-impedance input traces away from switching nodes and digital return currents. Verify the actual gain equation, common-mode range, output swing, and supply limits against the manufacturer datasheet before production release. This page combines Texas Instruments product specifications, package information, sourcing guidance, and practical design notes for engineers evaluating the INA2126PG4.

Запрос цены Контакты
INA2126U - 36V Dual Micropower Instrumentation Amplifier | Texas Instruments
INA2126U

INA2126U - 36V Dual Micropower Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA2126U is a dual-channel, 36 V micropower precision instrumentation amplifier with 250 µV offset, 175 µA quiescent current per channel, and a 16-pin SOIC package. It supports a wide ±1.35 V to ±18 V operating range and is designed for accurate, low-noise differential-signal acquisition. The device provides a gain range of 5 to 10000, a typical gain-bandwidth product of 200 kHz, and a typical input noise density of 0.4 nV/√Hz at 1 kHz. An instrumentation amplifier is a precision analog signal-conditioning IC that converts a small differential input into a single-ended or differential output. Its internal gain stage rejects common-mode interference and permits accurate measurement of low-level sensor signals. In the product hierarchy, an instrumentation amplifier belongs to the amplifier IC family, specifically the precision measurement and signal-conditioning category. It is distinct from a general-purpose operational amplifier because it integrates input buffering, differential subtraction, and gain-setting resistors. The INA2126U combines a gain range of 5 to 10000 with low offset and low noise. Its 250 µV maximum input offset supports accurate measurements at relatively high gain, while the 0.4 nV/√Hz typical noise density helps preserve weak-signal information. Two amplifiers are provided in each package, making the device useful when a system needs two independent differential measurement channels without using two separate packages. The two-op-amp architecture keeps quiescent current to 175 µA per channel, which is important in battery-powered equipment. The 200 kHz typical gain-bandwidth product provides useful bandwidth for slow sensor signals rather than high-speed video or communications signals. An operating supply of ±1.35 V to ±18 V allows operation from low-voltage portable rails through ±15 V industrial measurement systems, subject to the device's 36 V maximum total supply range. Typical uses include battery-powered portable instrumentation, low-level bridge and transducer measurement, industrial sensor acquisition, precision current sensing, and differential signal conditioning. The dual-channel organization can support two sensors in one instrument, while the micropower operation reduces the effect of the amplifier on battery life. Input common-mode and output swing limits must still be checked against the intended sensor and supply rails. Designers should use the gain-setting resistors and input common-mode network specified by the manufacturer, keep sensitive input traces short, and provide suitable bypassing close to the supply pins. The input network must also avoid excessive imbalance between the differential inputs because that can affect common-mode rejection and gain accuracy. Output loading and downstream ADC acquisition time should be evaluated together. This page combines manufacturer specifications, verified distributor availability, and practical comparison guidance with same-package alternatives. It also identifies missing pricing, pin-definition, environmental, and compliance details instead of estimating them, supporting faster component selection for precision analog designs.

Запрос цены Контакты
INA2126UA - Dual 36V Micropower INA | Texas Instruments
INA2126UA

INA2126UA - Dual 36V Micropower INA | Texas Instruments

Texas Instruments INA2126UA is a dual-channel precision instrumentation amplifier with a 36 V maximum supply, 175 µA quiescent current per channel, and 250 µV input offset voltage in a 16-pin SOIC (D) package. It is designed for accurate, low-noise differential-signal acquisition where low power and common-mode rejection are important. An instrumentation amplifier is a specialized analog amplifier that combines differential input measurement, high input impedance, and accurate gain-setting in one package. Within the signal-chain hierarchy, it sits between sensors or bridge networks and higher-level ADC, control, or monitoring systems. Its differential architecture rejects common-mode interference while preserving the small voltage variations being measured. The INA2126UA provides two amplifier channels, a 5 V/V to 10,000 V/V programmable gain range, and a gain error of no more than 0.04%. A typical input offset of 250 µV supports precision measurements, while the low 175 µA-per-channel quiescent current suits battery-powered and portable instrumentation. The device operates across an extended temperature range of -40°C to +85°C. Internally, the INA2126 family uses a two-op-amp instrumentation-amplifier architecture. This structure provides a practical balance between low power, low noise, common-mode rejection, and user-programmable gain. The external resistor between the RG pins establishes the differential gain, allowing one device to serve multiple measurement ranges without changing the analog front end architecture. Typical uses include bridge-transducer signal conditioning, portable measurement systems, battery-powered diagnostic equipment, industrial sensor interfaces, and low-current precision sensing. Its differential inputs are particularly useful when the source includes substantial common-mode voltage or interference relative to the wanted signal. Design the layout around the RG resistor, input filtering, and supply grounding. Place the gain-setting resistor close to the device, provide adequate bypassing on both supply rails, and maintain a quiet return path to minimize errors that can dominate microvolt-level measurements. Use the pin-description table in the manufacturer datasheet when assigning PCB tracks and checking exposed alternatives. This product page combines the manufacturer specifications with practical selection guidance, application analysis, pin-package context, and a parameter-by-parameter comparison. It is intended to help engineers identify whether the INA2126UA fits a low-power precision measurement design and how closely related same-family devices compare.

Запрос цены Контакты
INA2126UG4 - 36V Dual Micropower Instrumentation Amplifier | TI
INA2126UG4

INA2126UG4 - 36V Dual Micropower Instrumentation Amplifier | TI

The Texas Instruments INA2126UG4 is a dual 36 V micropower precision instrumentation amplifier with 175 µA quiescent current per channel, 250 µV offset, and differential-signal measurement capability in a 16-pin SOIC package. Its low power consumption and broad supply range suit battery-powered instrumentation, portable measurement systems, and low-current industrial sensors. An instrumentation amplifier is a signal-conditioning IC that amplifies the voltage difference between two input terminals while rejecting common-mode interference. The INA2126 belongs to the precision instrumentation amplifier hierarchy and supports accurate differential-signal acquisition. Its two-op-amp architecture combines low quiescent current with a wide operating-voltage range of ±1.35 V to ±18 V. Key features include 175 µA of quiescent current per channel, 250 µV offset, and operation from a single 2.7 V supply or from dual ±18 V rails. The device is intended for low-level differential measurements where battery life, signal integrity, and compactness are important. Two channels in one package can reduce board area when multiple sensor inputs must be conditioned. The 36 V maximum supply gives designers substantial transient and common-mode headroom in industrial environments, although the input common-mode range remains dependent on the selected supply and gain configuration. The precision-oriented internal architecture is intended to preserve small differential signals while reducing supply and common-mode errors. Designers should review gain, input range, output swing, and supply limits in the manufacturer datasheet before fixing system operating conditions. Typical uses include bridge-sensor interfaces, current-shunt measurements, portable multimeter circuits, battery-powered sensor acquisition, medical monitoring equipment, and industrial process-control inputs. The low 175 µA-per-channel quiescent current is particularly valuable in portable systems where amplifier current directly affects available battery runtime. Decoupling and layout are critical because the instrument-amplifier pins connect directly to low-level sensor signals. Place the supply bypass capacitor close to the positive and negative supply pins, connect the input return paths close to the amplifier, and use the differential inputs symmetrically. Validate the complete gain, common-mode range, output swing, noise, and settling-time combination on the target board.

Запрос цены Контакты
INA2128P - Dual Precision Instrumentation Amplifier | TI
INA2128P

INA2128P - Dual Precision Instrumentation Amplifier | TI

The Texas Instruments INA2128P is a dual, low-power instrumentation amplifier with two independent amplifiers, a gain range of 1 to 10,000, and a 200 kHz bandwidth at a gain of 100. The device is offered in a 16-pin PDIP package. Its precision characteristics include 50 uV maximum offset voltage, 0.5 uV/degree C maximum input offset drift, 5 nA maximum input bias current, and 120 dB minimum common-mode rejection. An instrumentation amplifier is a differential analog signal-conditioning IC that amplifies the voltage difference between two inputs while rejecting common-mode interference. In the signal-chain hierarchy, an instrumentation amplifier is a specialized amplifier, a precision analog front end, and an active analog integrated circuit. The INA2128P uses a three-op-amp arrangement and current-feedback input circuitry to preserve useful bandwidth even when relatively high gain is selected. A single external resistor sets the gain from 1 to 10,000, simplifying adjustment during design and calibration. The 200 kHz bandwidth available at gain 100 supports accurate amplification of sensors and low-frequency measurement signals without requiring the bandwidth of a high-speed instrumentation amplifier. Input protection extending to plus or minus 40 V also helps control fault energy applied to the input pins, although it does not eliminate the need for normal application-level protection. The INA2128P provides two amplifier circuits in one package, allowing a dual-channel design to reduce board area and component count. Its low offset voltage and low drift are particularly useful when the amplified differential signal is small relative to the measurement resolution. The specified 120 dB minimum common-mode rejection helps suppress noise and voltage that appears equally on both inputs, while the low 5 nA maximum input bias current suits high-impedance sources. Typical uses include bridge-sensor signal conditioning, portable instrumentation, biomedical measurement, industrial process monitoring, and two-channel sensor acquisition. The device can also amplify differential outputs from transducers where low offset and common-mode rejection are more important than wide-bandwidth conversion performance. Designers should follow the manufacturer datasheet for the gain-setting resistor, supply bypassing, input protection, and pin assignments. The power-supply range is plus or minus 18 V, so both positive and negative rails are permitted when the circuit requires bipolar input or output ranges. Decoupling capacitors should be placed close to the supply pins, and source impedance should remain compatible with the amplifier's bias-current and bias-voltage requirements. This page combines verified manufacturer and distributor information with package-aware alternatives, application guidance, and engineering-focused selection notes. It also separates verified INA2128P data from parameters that require confirmation in the full datasheet, helping engineers plan a board revision without treating incomplete data as guaranteed specifications.

Запрос цены Контакты
INA2128PA - Dual Instrumentation Amplifier | Texas Instruments
INA2128PA

INA2128PA - Dual Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA2128PA is a dual, low-power, general-purpose instrumentation amplifier with gains from 1 to 10,000, a 16-pin PDIP package, and operation over -40°C to +85°C. It uses a current-feedback input architecture to maintain a bandwidth of 200 kHz at a gain of 100, while providing low offset voltage, low offset drift, high common-mode rejection, and input protection to ±40 V. An instrumentation amplifier is a precision analog signal-conditioning IC that amplifies the difference between two input voltages while rejecting signals common to both inputs. Its internal three-op-amp architecture supports accurate differential measurements from low-level sensors. Within the broader semiconductor hierarchy, an instrumentation amplifier belongs to the amplifier IC and analog signal-conditioning categories, where it sits between a sensor or bridge and a measurement, control, or data-conversion system. Key features include a maximum offset voltage of 50 µV, maximum offset drift of 0.5 µV/°C, maximum input bias current of 5 nA, and minimum common-mode rejection of 120 dB. A single external resistor sets the gain from 1 to 10,000. The dual configuration provides two independent amplifier channels, allowing one package to serve differential measurements or multiple sensor inputs. The current-feedback input circuitry is the principal performance feature. Unlike a voltage-feedback instrumentation amplifier that loses bandwidth as gain increases, the INA2128 family retains useful bandwidth at high closed-loop gain; the specified bandwidth is 200 kHz at gain 100. The three-op-amp topology also makes the input bias-current behavior relatively insensitive to source impedance, which is valuable when the source is a strain gauge, thermocouple, bridge, or other high-impedance sensor. Typical applications include bridge-based pressure and load-cell measurements, biomedical instrumentation, current-loop sensing, precision data acquisition, and low-level differential signal conditioning. The ±40 V input protection expands the usable fault-tolerance range, but it does not permit operation beyond the device's stated supply-voltage ratings. Designers should still limit input transients and maintain common-mode voltage within the operating region described by the manufacturer datasheet. The primary design consideration is gain-setting resistor selection because the external resistor determines gain while also affecting bandwidth, noise, and allowable operating range. Place the gain-setting resistor close to the corresponding gain resistor pins, maintain symmetrical input routing, provide adequate supply bypassing, and use a stable reference ground. This page combines device specifications, application guidance, lifecycle information, and drop-in alternative evaluation for faster engineering selection. For a dual-channel instrumentation amplifier where PCB area is limited, the INA2128PA provides a direct fit in a 16-pin PDIP footprint. The through-hole package also supports prototype and industrial repair workflows where a surface-mount assembly process would add unnecessary handling complexity.

Запрос цены Контакты
INA2128U - Dual Precision Instrumentation Amplifier | TI
INA2128U

INA2128U - Dual Precision Instrumentation Amplifier | TI

The Texas Instruments INA2128U is a dual, low-power, general-purpose instrumentation amplifier packaged in a 16-pin SOIC. It uses a versatile three-op-amp architecture and current-feedback input circuitry to support broad bandwidth even at high gain. A single external gain-setting resistor provides gains from 1 to 10,000, while the two independent amplifier channels support simultaneous differential measurements or dual-channel sensing. An instrumentation amplifier is a specialized analog amplifier designed to measure small differential voltages accurately in the presence of large common-mode voltages. Its typical signal-chain hierarchy is differential input -> instrumentation amplifier -> precision analog measurement or control system. The INA2128U supports input-referenced and ground-referenced sensing, where unwanted signals common to both inputs are rejected while the differential component is amplified. The principal benefits of the INA2128U are its dual-channel configuration, selectable gain from 1 to 10,000, and bandwidth of 200 kHz at a gain of 100. Current-feedback input circuitry helps preserve usable bandwidth as gain increases. The low-power architecture is suitable for compact analog measurement systems, portable instrumentation, and industrial equipment where two precision analog channels must fit into a small board area. Internally, each channel follows a three-op-amp instrumentation-amplifier topology. Differential input currents are directed toward internal feedback paths, while a single external resistor establishes the gain relationship. Because the circuit supports both single-ended and differential input arrangements, engineers can adapt it to sensor bridges, shunt measurements, and bipolar input signals. The dual organization also allows synchronized acquisition of two related signals without requiring two separate packages. Typical uses include medical instrumentation, industrial sensor interfaces, battery-powered measurement equipment, current-shunt monitoring, and precision data-acquisition systems. Differential inputs are particularly useful when a sensor produces a small voltage riding on a larger common-mode voltage. Pairing the two channels can also support gain-and-offset measurement, comparator-style monitoring, or sampled systems requiring closely matched amplifier paths. A practical design must account for the external gain resistor, input and output settling, reference-ground connection, supply decoupling, and common-mode range. Place the gain-setting resistor close to the device and use the manufacturer's recommended layout and decoupling guidance. Maintain the input and output common-mode voltages within the operating limits, and verify system settling at the highest gain required by the measurement bandwidth. This product page organizes the manufacturer's functional description, package information, comparison considerations, and application guidance into one engineering-focused resource. It also identifies where pin-level and qualification details must be checked in the manufacturer datasheet before a new board is released to production.

Запрос цены Контакты
INA2128U/1K - Dual Instrumentation Amplifier | Texas Instruments
INA2128U/1K

INA2128U/1K - Dual Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA2128U/1K is a dual, low-power instrumentation amplifier with two independent signal channels, selectable gain from 1 to 10,000, and a 16-pin SOIC package. It accepts bipolar input signals, provides a bandwidth of 200 kHz at a gain of 100, and operates from dual power supplies up to ±18 V. A single external gain resistor sets the gain of each channel. An instrumentation amplifier is a specialized amplifier-and-op-amp category designed to amplify small differential signals while rejecting common-mode interference. Its internal three-op-amp architecture provides high input impedance, symmetrical differential inputs, accurate gain control, and straightforward scaling of sensor outputs. Within the broader semiconductor hierarchy, the INA2128 belongs to the precision analog amplifier class and is used as a front-end signal-conditioning component between sensors or measurement networks and data converters. Key features include two independent amplifiers on one die, a gain range of 1 to 10,000, and current-feedback input circuitry that maintains useful bandwidth at higher gain. The 200 kHz bandwidth quoted at gain 100 makes the device suitable for sensors whose signals must be measured with limited filtering. Its dual-channel arrangement also reduces board area when two independent measurements are required, such as sensing a bridge output and a reference voltage. The three-op-amp architecture uses external gain-setting resistors and internal precision circuitry. Because the signal path is differential, common-mode voltage and gain errors can be rejected more effectively than with a single ordinary op-amp stage. Designers must nevertheless consider resistor tolerance, input common-mode range, output swing, supply headroom, and stability when adding input and output filtering capacitors. Typical applications include bridge and strain-gauge front ends, industrial pressure and temperature measurement, portable instrumentation, biomedical instrumentation, and precision current sensing. The dual-channel configuration is particularly useful when a system must amplify two low-level differential signals with closely matched electrical characteristics. For reliable operation, keep input and output components close to their associated pins, use a low-noise supply arrangement, and verify that the common-mode and output voltages remain inside the device operating limits. The gain resistor should use an appropriate tolerance and temperature coefficient for the required measurement accuracy. Stable reference or sensor grounding is also essential because excessive ground gradients can appear directly as measurement error. This page combines manufacturer specifications, package and ordering information, validated replacement candidates, application guidance, and design notes to provide a practical engineering reference for the INA2128U/1K.

Запрос цены Контакты
INA2128UA - Dual Precision Instrumentation Amplifier | Texas Instruments
INA2128UA

INA2128UA - Dual Precision Instrumentation Amplifier | Texas Instruments

Texas Instruments INA2128UA is a dual, low-power instrumentation amplifier with two independent channels, gain adjustment from 1 to 10,000 using one external resistor, and a 16-pin SOIC package. Each channel provides a maximum offset voltage of 50 uV, maximum offset drift of 0.5 uV/degree C, maximum input bias current of 5 nA, and a minimum common-mode rejection ratio of 120 dB. An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals superimposed on larger common-mode voltages. Its internal three-op-amp architecture provides matched input stages, high differential input impedance, accurate gain control, and strong common-mode rejection. This makes the INA2128 suitable for sensor interfaces where a low-level differential signal must be amplified accurately in the presence of substantial DC voltage, industrial noise, or ground-potential differences. The INA2128 combines low offset and drift with a minimum 120 dB CMRR. Input overload protection extends to plus or minus 40 V, helping the amplifier tolerate accidental large input transients. Its supply range of 2.25 V to 18 V supports single-supply and dual-supply instrumentation systems. A single external resistor selects the gain, reducing the number of precision components needed for adjustable measurement channels. The versatile three-op-amp design uses current-feedback input circuitry to preserve bandwidth at higher gains. According to the Texas Instruments datasheet, bandwidth remains 200 kHz at a gain of 100. This combination of precision DC behavior and usable high-gain bandwidth makes the device suitable for bridge sensors, current measurement, biomedical instrumentation, and industrial data-acquisition systems. Typical uses include low-voltage pressure and strain-signal conditioning, thermocouple and RTD amplification, current-shunt measurement, battery-cell monitoring, and precision analog-front-end designs. The two-channel configuration is especially useful when a system must process two related sensor inputs while maintaining consistent gain-setting and supply architecture across both channels. Choose gain resistors with suitable tolerance and temperature coefficient, and verify common-mode headroom at the lowest supply voltage. Input and reference pins require careful layout because leakage, parasitic resistance, and asymmetric copper can degrade CMRR. The gain-setting resistor should be placed close to the device, with symmetrical input routing where practical. This product overview combines manufacturer specifications, package details, application guidance, and drop-in replacement information to support faster component selection and PCB planning. It also identifies the trade-offs involved when changing amplifier families, including gain range, bandwidth, offset performance, supply voltage, and protection requirements.

Запрос цены Контакты
INA2128UG4 - Dual Instrumentation Amplifier | Texas Instruments
INA2128UG4

INA2128UG4 - Dual Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA2128UG4 is a dual, low-power instrumentation amplifier with two independent amplifier channels, gain settings from 1 to 10,000, and bandwidth of 200 kHz at a gain of 100. The device is packaged in a 16-pin SOIC and is specified for operation from -40°C to +85°C. An instrumentation amplifier is a precision analog signal-conditioning IC that amplifies the voltage difference between two inputs while rejecting common-mode signals. Its internal three-op-amp architecture provides a practical combination of high input impedance, accurate differential gain, and common-mode rejection. This places the INA2128UG4 in the hierarchy of instrumentation amplifier, analog signal conditioner, amplifier IC, and semiconductor. The principal features include a dual-channel configuration, low-power operation, user-programmable gain from 1 to 10,000 using one external resistor, and current-feedback input circuitry that maintains useful bandwidth at high gain. These characteristics suit sensor outputs, bridge-based measurements, biomedical instrumentation, and analog signal chains where small differential signals must be measured accurately in the presence of larger common-mode voltages. The three-op-amp topology separates differential input handling from the gain-setting network, helping simplify circuit design and reduce external component count. A single gain resistor establishes the selected gain, while internal input and feedback stages provide the required signal amplification. The result is a versatile general-purpose instrumentation amplifier that can serve both precision measurement and general instrumentation applications. Typical uses include pressure and temperature sensor interfaces, strain-gauge and Wheatstone bridge excitation, biomedical signal acquisition, current-shunt measurement, laboratory instrumentation, and low-level analog front ends. The dual architecture allows two independent sensor channels in one package, reducing board area when both channels are required. Designers should place the gain-setting resistor close to the gain pins, observe the input and output common-mode limits, and decouple the supply pins according to the manufacturer datasheet. Input and output filtering should be selected for the required bandwidth because excessive capacitance can affect stability and phase margin. The operating temperature range also requires thermal verification for the complete board assembly. This product page combines the INA2128UG4 device identity, package and gain details with practical application guidance, same-family alternatives, and a parameter-focused comparison. It is designed to help engineers locate the datasheet, verify pin compatibility, understand bandwidth constraints, and plan an instrumentation front end before requesting a quote.

Запрос цены Контакты
INA2132U - Dual 36V Difference Amplifier | Texas Instruments
INA2132U

INA2132U - Dual 36V Difference Amplifier | Texas Instruments

The Texas Instruments INA2132U is a dual, low-power, single-supply difference amplifier operating from 2.7 V to 36 V and providing two matched amplifier channels in a 14-pin SOIC package. Its input stage supports common-mode voltages from -15 V to 28 V, while a minimum common-mode rejection ratio of 76 dB helps reject equal-magnitude signals applied to both inputs. The device operates over a -40 °C to 85 °C temperature range and is suitable for industrial measurement, sensing, and signal-conditioning systems. A difference amplifier measures the voltage between two input nodes rather than amplifying a single node relative to ground. In the signal-chain hierarchy, the INA2132U is a difference amplifier, which is a subtype of instrumentation amplifier, and ultimately belongs to the broader amplifier and analog signal-conditioning categories. The dual-channel configuration allows one package to handle two differential sensing channels while maintaining consistent amplifier characteristics between them. Key features include the 2.7 V to 36 V single-supply operating range, 76 dB minimum common-mode rejection, and a -40 °C to 85 °C industrial temperature rating. The low-power architecture is appropriate for systems in which every milliampere affects battery life, thermal rise, or analog headroom. A common-mode range extending below ground makes the device useful in shunt-monitoring systems where the signal may be referenced to a supply rail rather than to ground. The INA2132U is designed for differential measurements where the useful information is small compared with the common-mode voltage. Both amplifier channels are implemented in the same device, which supports matched measurements and reduces the number of external packages required. Its SOIC package also supports conventional surface-mount assembly, although exposed-pad thermal management is not specified in the available ordering information. Typical applications include high-side or low-side current sensing, bridge-sensor signal conditioning, battery monitoring, industrial process measurement, and differential voltage acquisition. When designing around this part, verify the signal amplitude, common-mode limits, and output-swing requirements against the application before committing the footprint. This page combines manufacturer product information, verified distributor pricing and availability, and engineering guidance that goes beyond a basic distributor listing. It also documents where additional datasheet parameters are required so engineers can distinguish confirmed values from information that must still be checked against the manufacturer datasheet.

Запрос цены Контакты
INA2132UA - Dual 36V Difference Amp | Texas Instruments
INA2132UA

INA2132UA - Dual 36V Difference Amp | Texas Instruments

Texas Instruments INA2132UA is a dual-channel, low-power, single-supply difference amplifier with a 2.7 V to 36 V supply range, 76 dB minimum common-mode rejection, and a 14-pin SOIC package. Each channel amplifies the voltage difference between two input pins while rejecting common-mode signals, making the device suitable for precision bridge sensing, current measurement, and industrial signal-conditioning systems. A difference amplifier is a specialized amplifier architecture that subtracts two input voltages and multiplies the result by a defined gain. Its role within the amplifier hierarchy is amplifier IC to instrumentation amplifier to low-power difference amplifier. Internal precision resistors establish the nominal gain, while the amplifier rejects signals common to both inputs. This architecture reduces errors in sensor systems where a small differential signal is superimposed on a larger common-mode voltage. The INA2132UA provides two amplifier channels, a common-mode input range extending from -15 V to 28 V, and a bandwidth of approximately 3 MHz. Its 36 V maximum supply capability supports higher-voltage industrial systems. The 14-pin SOIC package allows straightforward surface-mount assembly, while the -40 °C to +85 °C operating range supports industrial temperature environments. Each channel combines a precision operational-amplifier core with a laser-trimmed resistor network. This construction supports consistent gain and common-mode rejection without requiring external gain-setting resistors. Because both channels are integrated into one package, designers can use the two amplifiers for complementary measurement channels, differential sensing, or two-stage signal conditioning within the same circuit. Typical uses include Wheatstone-bridge sensor front ends, motor-current monitoring, differential voltage measurement, and industrial process-control inputs. The common-mode rejection characteristic is particularly useful when the desired signal is much smaller than the voltage shared by both input terminals. The approximately 3 MHz bandwidth also allows the amplifier to process signals beyond static or very slow sensor outputs. When designing the circuit, verify that input, output, and supply voltages remain within their operating limits at every temperature and tolerance corner. Keep sensitive input routing short, maintain symmetric layouts around the differential pair, and use stable reference and bypass connections to minimize offset and noise errors. A single-supply design also requires careful review of the output common-mode range when the amplified difference can approach either supply rail. This page consolidates manufacturer specifications, package details, application guidance, and same-footprint replacement information into a design-oriented resource for engineers evaluating the INA2132UA.

Запрос цены Контакты