AD565AKD/+ - 12-Bit Mono DAC, 24-CDIP | Analog Devices
料号: AD565AKD/+ ✗ 停产AD565AKD/+ 概述
A digital-to-analog converter is a data-conversion IC that transforms a digital code into a proportional analog voltage or current. In the broader electronics hierarchy, a DAC belongs to data-converter ICs, interface electronics, and power-management-adjacent signal-chain components. The AD565AKD/+ provides the final analog output stage in systems that also contain digital control logic, a clock interface, reference circuitry, output buffering, and analog signal conditioning.
The headline features of the AD565AKD/+ are its 12-bit conversion resolution, one DAC channel, and 24-CDIP package. Its monolithic implementation consolidates the converter into a single IC, while the buried Zener reference supplies a low-noise internal reference with long-term stability and temperature-drift characteristics designed for precision applications. The manufacturer describes the AD565A as a high-speed 12-bit monolithic DAC family, making it suitable for compact analog-output subsystems where discrete reference and converter stages would otherwise increase component count.
The AD565AKD/+ uses the same AD565A converter family identified on the Analog Devices product page. Exact settling time, differential nonlinearity, integral nonlinearity, DNL monotonicity, reference voltage, output range, supply requirements, and digital-interface timing must be confirmed in the manufacturer datasheet before a new circuit is released. These parameters determine the usable code-to-voltage relationship, allowable update rate, output impedance requirements, and the amount of reconstruction filtering needed after the DAC.
Typical uses include industrial process-control output modules, laboratory instrumentation, programmable test equipment, legacy data-acquisition systems, and embedded analog signal generators. In a process-control design, the DAC can produce a command voltage that is filtered and scaled before driving an actuator or measurement front end. In test equipment, it can synthesize calibration and stimulus levels. Because the AD565A is not recommended for new designs, engineers should also consider whether a currently recommended converter would reduce long-term sourcing and redesign risk.
For implementation, place the output-filter network close to the converter and route analog signals away from high-speed digital transitions. Confirm the package pin assignments, analog and digital ground strategy, reference bypass requirements, and output-loading limits in the manufacturer datasheet. Do not substitute an alternative solely because it has the same resolution; verify pinout, interface logic, reference arrangement, output range, and supply requirements first.
This page combines the manufacturer product information, lifecycle position, sourcing guidance, technical comparisons, and design cautions for engineers supporting AD565AKD/+ systems. It also identifies why a similarly packaged converter may require interface review, and why legacy design decisions should be separated from the requirements of a new, forward-looking analog-output platform.
直接替换替代料: AD565AKD/+ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: AD565AKD/+ (相同外形与封装尺寸) ——差异在于 Resolution.
AD565AJD/+
✅ 直接替换联系询价
查看数据手册 →AD565AKD/+ 最大额定值与电气特性
| Converter Type | 12-bit monolithic digital-to-analog converter |
| 分辨率 | 12 bit |
| Number of Channels | 1 channel |
| Architecture | Monolithic DAC |
| Internal Reference | Buried Zener reference |
| Reference Characteristics | Low-noise, long-term-stable reference with temperature-drift characteristics comparable to discrete reference diodes |
| 封装 | 24-CDIP |
| 引脚数 | 24 pins |
| 安装类型 | Through-hole |
| Product Lifecycle Recommendation | Not recommended for new designs |
AD565AKD/+ 24-cdip 引脚配置指南
AD565AKD/+(24-cdip 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: AD565AKD/+.
请参阅 数据手册 以查看完整引脚配置。
典型应用
AD565AKD/+ 适用于 6 应用s: Industrial Process-Control Output, Laboratory Instrument Signal Source, Programmable Test and Calibration Systems, Legacy Data-Acquisition Analog Output, Precision Analog Signal Generation, Legacy Control-System Spare Part.
Industrial Process-Control Output
The AD565AKD/+ fits legacy process-control modules that require a 12-bit command voltage for actuator, valve, or test-signal interfaces. Its single-channel monolithic DAC output simplifies the analog-generation stage while the buried Zener reference provides an internal reference with low-noise, long-term-stability, and temperature-drift characteristics designed for precision work. In an installed control system, the converter can be driven by existing digital control logic and followed by an analog reconstruction or output-conditioning network. Because the AD565A family is not recommended for new designs, engineers should prefer this device when preserving an existing board is more valuable than starting with a currently supported platform. Verify the exact supply, output range, settling time, and load-driving limits in the manufacturer datasheet before adding it to a new control board.
推荐
Laboratory Instrument Signal Source
The AD565AKD/+ can generate controlled analog levels in laboratory instruments that already use the AD565A interface and 24-CDIP layout. The 12-bit resolution provides 4096 digital code positions, while the single output channel is sufficient for calibration, excitation, offset, or reference-control functions. Its buried Zener reference removes the need for a separate reference arrangement in compatible legacy circuits and supports repeatable output behavior over time. The converter is normally paired with a low-pass or reconstruction filter to remove digital-code transitions before the signal reaches the analog output connector. For new instruments, compare the converter with currently recommended DACs; for established equipment, retaining AD565AKD/+ can minimize mechanical, firmware, and qualification changes. Confirm exact settling and output-buffer requirements before release.
推荐
Programmable Test and Calibration Systems
The AD565AKD/+ is appropriate for legacy automated test equipment that must synthesize calibration voltages or programmable stimuli. Its 12-bit resolution and one-channel output match common resistor-network or gain-stage architectures in which a digital code commands a precision voltage. The internal buried Zener reference is useful in measurement equipment because it avoids a separate discrete reference stage and preserves the intended AD565A signal-chain behavior. Place the converter output directly into the existing passive or active reconstruction network, and account for settling time whenever a test sequence changes the output rapidly. The device should be selected for maintenance of an existing 24-CDIP board rather than an unqualified new platform. Verify monotonicity, linearity, output compliance, and digital timing against the manufacturer datasheet.
推荐
Legacy Data-Acquisition Analog Output
The AD565AKD/+ can provide the analog-output complement to a legacy data-acquisition system, allowing a digital controller to produce excitation, control, or compensation voltages alongside acquired data. The 12-bit monolithic DAC provides a compact converter function in the 24-CDIP package, and the buried Zener reference supports stable operation in systems designed around the AD565A family. It is particularly useful when the digital interface and board geometry cannot be changed, because retaining the established architecture limits both hardware rework and firmware validation. Ensure the output is reconstructed and buffered according to the original circuit; do not assume a generic 12-bit DAC output can directly drive a high-capacitance or bipolar load. Because this family is not recommended for new designs, use it primarily for continuity and modernization of installed systems.
推荐
Precision Analog Signal Generation
The AD565AKD/+ is suitable for precision analog signal-generation blocks that need a 12-bit command interface, particularly in existing systems designed around Analog Devices AD565A converters. Its buried Zener reference has low-noise and long-term-stability characteristics intended to support accurate output generation without a separate discrete reference implementation. The output code can drive a passive reconstruction network, precision resistor ladder, or an existing output amplifier, depending on the required voltage range and load. Because the converter is single-channel, multi-channel systems require synchronized external multiplexing or separate converters. Verify monotonicity, differential and integral nonlinearity, output impedance, and settling time before selecting compensation or filter values. A currently recommended DAC may be preferable when the design is new rather than a lifecycle-maintenance project.
推荐
Legacy Control-System Spare Part
The AD565AKD/+ is especially relevant as a continuity part for control systems, analyzers, and industrial instruments already designed around the K-grade AD565A 24-CDIP converter. Retaining the same family and package can reduce risk when repairing an operating machine because analog calibration, control timing, and board layout remain unchanged. The single-channel 12-bit DAC can continue to generate the system command signal while the buried Zener reference maintains the intended reference behavior. When screening incoming stock, compare device markings, revision handling, and the exact suffix because a grade change may alter commercial-temperature suitability. Use the Request a Quote form for availability and include the original equipment part number when possible. Any substitute must pass a complete interface, temperature, and output-accuracy review before installation.
推荐
推荐产品汇总
工程参考数据: AD565AKD/+ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AD565AJD/+ |
|---|---|---|
| Brand | Analog Devices | Analog Devices |
| Package | 24-CDIP | 24-CDIP |
| Resolution | 12 bit | 12 bit |
| Number of Channels | 1 channel | 1 channel |
| Internal Reference | Buried Zener reference | Buried Zener reference |
| Temperature-Grade Suffix | K grade | J grade |
| Product Lifecycle Recommendation | Not recommended for new designs | Not recommended for new designs |
关键差异点
- Uses the K-grade ordering suffix within the legacy AD565A family (对比 AD565AJD/+)
- Combines a 12-bit single-channel monolithic DAC with a buried Zener reference (对比 AD565AJD/+)
- Supports direct continuation of an existing 24-CDIP AD565A design (对比 AD565AJD/+)
设计说明
Do not treat the J and K ordering suffixes as interchangeable without checking temperature requirements. The AD565AKD/+ and AD565AJD/+ share the AD565A converter family and 24-CDIP format, but the grade designation changes commercial-temperature suitability. For equipment operating outside the J-grade limits, retain the K-grade device or complete a formal thermal qualification. Also verify the complete pinout, digital timing, supply arrangement, and reference requirements rather than relying on resolution alone.
Preserve the established AD565A reference and analog-output layout when replacing the device in a working board. Keep the output reconstruction or smoothing network close to the converter, route the analog output away from switching-node and digital-clock traces, and maintain the original grounding strategy. Confirm whether the output requires passive loading, an active buffer, or DC offset correction. Unauthorized changes to reference or filtering networks can alter settling behavior and accuracy even when the converter code remains unchanged.
Check the converter's supply rails and reference bypass requirements directly from the manufacturer datasheet before inserting the AD565AKD/+. Ensure every supply remains within its specified operating range under startup, full-scale code transitions, and temperature extremes. Do not infer the reference voltage or output compliance from the internal buried Zener description alone. For a board already designed for AD565AKD/+, reproduce the original decoupling and grounding arrangement to avoid introducing supply transients that appear as analog-output errors.
合规信息