AD694JR - 4-20 mA Current Transmitter | Analog Devices
Артикул: AD694JR ✓ АктивенAD694JR Обзор
A current transmitter is an interface IC that converts a control or measurement voltage into a standardized current signal. This current-loop interface belongs to the sensor and detector interface hierarchy, linking sensors, programmable sources, and process-control equipment with field instrumentation. Unlike a digital sensor interface, the AD694 produces an analog loop current that can travel through industrial wiring while resisting signal corruption and maintaining compatibility with standard 4-20 mA receivers.
The AD694 includes an input buffer amplifier that can scale the incoming signal or buffer the output of a current-mode DAC. Its precalibrated input ranges reduce external adjustment requirements, while the precision reference provides a stable 10.000 V reference for systems that need accurate signal conditioning. The open-loop alarm feature can report a transmitter fault to downstream monitoring equipment when the loop cannot maintain its commanded state.
The AD694 family supports a wide power-supply range extending to +36 V and provides wide output compliance, allowing the transmitter to operate with common industrial supply conditions and practical loop loads. Operation from either a single or dual supply gives designers flexibility in instrumentation systems where one supply rail or bipolar rails are available. These features make the device useful for both compact transmitter modules and larger industrial control platforms.
Typical uses include process-control current-loop transmitters, actuator and valve controllers, programmable test and measurement systems, and factory automation equipment. A voltage from a sensor conditioner, controller, or current-mode DAC can be applied at the buffered input, while the AD694 converts it into a current suitable for a 4-20 mA loop. The result is a straightforward interface between low-level electronics and field-wired industrial devices.
When designing around the AD694JR, follow the manufacturer datasheet for input-range selection, supply connection, output-loop configuration, and compensation. Keep sensitive input routing away from the current-output path, and verify that the selected output range and supply polarity match the receiving instrument. The 16-lead SOIC package permits conventional surface-mount assembly but requires adequate copper and thermal management for reliable operation at elevated internal dissipation.
Аналоги без доработки для AD694JR — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с AD694JR (тот же форм-фактор и посадочное место) — отличается по Output Current Range, Package, Mounting Type, Function, Input Offset Voltage.
AD694ARZ
✅ Прямая заменаУточнить цену
Открыть даташит →AD694BRZ
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
AD694JR Характеристики
| Product Type | Monolithic current transmitter |
| Output Current Range | 4-20 mA or 0-20 mA |
| Input Signal Type | High-level voltage input |
| Precision Reference Voltage | 10.000 V |
| Maximum Supply Voltage | +36 V |
| Supply Configuration | Single or dual supply operation |
| Input Buffer | Integrated input buffer amplifier |
| Alarm Function | Open-loop alarm |
| Корпус | 16-lead SOIC |
| Тип монтажа | Surface mount |
Руководство по цоколевке AD694JR в корпусе 16-lead soic
Цоколевка для AD694JR (корпус 16-lead soic). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.
Нет подробных данных о распиновке для AD694JR.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
AD694JR подходит для 6 применениеs: Process-Control Current Transmitters, Valve and Actuator Control, Factory Automation Signal Conditioning, Programmable Test and Measurement Systems, Industrial Data Acquisition, Transmitter Module Electronics.
Process-Control Current Transmitters
The AD694JR fits process-control transmitter boards that must convert a high-level control voltage into a standard 4-20 mA signal. Its monolithic current-transmitter architecture accepts a buffered input and drives the loop while providing an open-loop alarm for downstream fault detection. The integrated 10.000 V reference supports repeatable signal conditioning, while single- or dual-supply operation lets the circuit adapt to different industrial signal-chain architectures. In a transmitter design, the AD694JR sits between the sensor conditioner or controller and field wiring, with the output range configured to match the receiving controller.
Рекомендуется
Valve and Actuator Control
The AD694JR is suitable for current-loop interfaces that operate proportional valves, actuators, and related field equipment. A control voltage can be applied to the AD694 input buffer and converted into either a 4-20 mA or 0-20 mA command, depending on the selected configuration. The input buffer can also accept a signal from a current-mode DAC, making the transmitter useful in programmable industrial test systems. Because the AD694 family supports supply voltages extending to +36 V and includes an open-loop alarm, the circuit can combine field-side loop drive with basic wiring-fault monitoring.
Рекомендуется
Factory Automation Signal Conditioning
The AD694JR can be used in factory automation modules that translate controller-level voltage signals into standardized current for long-distance field wiring. Its buffered input reduces the loading seen from the originating control circuit, while the 4-20 mA or 0-20 mA output supports conventional industrial receivers. The open-loop alarm allows a supervisory system to identify a broken loop or transmitter output failure. The 16-lead SOIC package is appropriate for compact PCB-mounted instrumentation, although the design must follow the manufacturer's grounding, decoupling, and output-compliance guidance.
Рекомендуется
Programmable Test and Measurement Systems
The AD694JR is appropriate for test and measurement equipment that must emulate or interface with industrial 4-20 mA loops. Its input buffer can scale an external source or buffer a current-mode DAC output, allowing the transmitter to convert a programmable command into a representative loop current. The family also offers a 0-20 mA range for compatible receivers and a precision 10.000 V reference for stable measurement conditions. Designers should configure the selected input range and output polarity from the Analog Devices datasheet and verify loop compliance against the intended load resistance.
Рекомендуется
Industrial Data Acquisition
The AD694JR can bridge an analog measurement or control source to industrial receivers that use current-loop signaling. A sensor conditioner output or controller voltage is applied to the buffered input, and the transmitter generates the required current for the connected instrument. This is useful in data-acquisition equipment where standardized current simplifies cabling, grounding, and interoperability between transmitters and receiving modules. The AD694's precalibrated input ranges and integrated reference support predictable conversion, while the open-loop alarm provides an additional path for reporting loop or output faults.
Рекомендуется
Transmitter Module Electronics
The AD694JR is suitable for compact transmitter modules that need a dedicated analog current-loop output stage. Its monolithic implementation combines the input buffer, reference, current transmitter, and alarm capability in a 16-lead SOIC, reducing the number of separate signal-conditioning blocks. Single- and dual-supply options permit integration with different field-side power architectures, and the range extending to +36 V supports industrial supply conditions. The module designer must still follow the manufacturer guidance for decoupling, grounding, thermal performance, and output-loop protection.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для AD694JR — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | AD694ARZ | AD694BRZ |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-lead SOIC | 16-lead SOIC | 16-lead SOIC |
| Product Type | Monolithic current transmitter | Monolithic current transmitter | Monolithic current transmitter |
| Output Current Range | 4-20 mA or 0-20 mA | 4-20 mA or 0-20 mA | 4-20 mA or 0-20 mA |
| Input Signal Type | High-level voltage input | High-level voltage input | High-level voltage input |
| Precision Reference | 10.000 V | 10.000 V | 10.000 V |
| Maximum Supply Voltage | +36 V | +36 V | +36 V |
| Supply Configuration | Single or dual supply operation | Single or dual supply operation | Single or dual supply operation |
| Alarm Function | Open-loop alarm | Open-loop alarm | Open-loop alarm |
| Input Buffer | Integrated input buffer amplifier | Integrated input buffer amplifier | Integrated input buffer amplifier |
Ключевые отличия
- Combines current-loop conversion, input buffering, reference, and alarm functions (против AD694ARZ)
- Provides a footprint-compatible path for industrial transmitter modules (против AD694BRZ)
- Supports both single- and dual-supply instrumentation architectures (против AD694ARZ)
Заметки по проектированию
Configure the AD694JR for the supply arrangement shown in the manufacturer datasheet for the selected input range and loop-output mode. Place the required bypass capacitors close to the supply pins and provide a low-impedance ground return for the transmitter and loop receiver. Because the family supports supply voltages extending to +36 V, verify the selected operating point against the application's field-side voltage rather than assuming a low-voltage instrumentation rail.
Keep the buffered input and reference routing away from the current-loop output and power-supply nodes to avoid coupling high-energy or fast-changing signals into the measurement path. Use a continuous ground plane where practical, but route the loop return without unnecessary sharing with sensitive input-return paths. Follow the Analog Devices AD694 application guidance for decoupling, grounding, output protection, and the 16-lead SOIC land pattern.
Do not select between the AD694JR, AD694ARZ, and AD694BRZ based on the SOIC footprint alone. Confirm the required operating-temperature grade, qualification, electrical limits, and ordering information in the Analog Devices AD694 documentation. Also confirm whether the receiver expects 4-20 mA or 0-20 mA, and verify output compliance against the maximum loop resistance before enabling the transmitter.