CD4029BM - 4-Bit Binary/Decade Up/Down Counter | TI
Артикул: CD4029BM ✓ АктивенCD4029BM Обзор
A counter is a sequential digital circuit that stores and advances a binary number on each active clock transition. A presettable up/down counter can move toward either a higher or lower count, while binary and BCD-decade modes determine how the four counter bits represent the counted value. This makes the CD4029BM useful within the broader CMOS logic family, logic IC hierarchy, digital counter category, and broader digital semiconductor market.
The principal feature is configurable counting behavior. A BINARY/DECADE input selects between binary and BCD-decade operation, while an UP/DOWN input establishes the counting direction. Four JAM inputs allow individual counter stages to be preset, and CARRY-IN provides clock-enable or look-ahead carry functionality. A dedicated CARRY OUT output indicates overflow in the selected counting mode. These controls support programmable event counting, sequence generation, batch counting, and arithmetic-oriented digital logic.
The CD4029BM is a four-stage CMOS counter rather than a general-purpose microprocessor or programmable controller. Its clocked operation provides deterministic state transitions, while the parallel outputs expose the current count for decoding, display driving, comparison, or control. Because the device includes look-ahead carry in both counting modes, it can also support cascaded counting arrangements when a higher-resolution count range is required.
Typical uses include industrial batch counters, laboratory timer and event-count circuits, digital instrumentation, frequency-division and sequencing logic, automotive and consumer control modules, and teaching or prototyping systems. The logic voltage supply and operating limits should be confirmed against the manufacturer datasheet before using the counter with modern low-voltage peripherals.
For reliable implementation, connect the clock and control inputs to compatible CMOS logic levels, use pull-down or pull-up resistors where a control may float, and decouple the supply close to the device. Treat all unused inputs as defined logic states. The JAM and preset paths are especially important to review because incorrect active levels can immediately load or suppress the counter rather than permit normal counting.
This page combines the manufacturer function description, package information, pin assignments, drop-in replacement analysis, application guidance, and practical design notes into a single engineering reference. It helps designers identify the correct counting mode, verify package compatibility, plan PCB routing, and evaluate replacement options before committing a design to production.
Аналоги без доработки для CD4029BM — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
CD4029BC
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
MC14029BDR2G
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
CD4029BM Максимальные параметры и электрические характеристики
| Counter Type | 4-stage binary or BCD-decade up/down counter |
| Number of Counter Stages | 4 stages |
| Counter Width | 4 bits |
| Counting Direction | Up or down |
| Clock Edge | Positive edge |
| Counting Modes | Binary or BCD-decade |
| Jam Inputs | 4 individual JAM inputs |
| Carry Inputs | 1 CARRY-IN input with look-ahead carry |
| Carry Outputs | 1 CARRY OUT output |
| Counter Outputs | Q1, Q2, Q3, and Q4 |
| Control Inputs | CLOCK, CARRY-IN, BINARY/DECADE, UP/DOWN, PRESET ENABLE, and 4 JAM inputs |
| Logic Family | CMOS |
| Корпус | 16-pin SOIC |
| Lead Spacing | 0.1 inch |
| Тип монтажа | Surface mount |
Конфигурация выводов CD4029BM
| Контакт 1 | CLOCK — Positive-edge clock input |
| Контакт 2 | CARRY IN — Carry input and clock-enable control |
| Контакт 3 | BINARY/DECADE — Binary or BCD-decade counting-mode selection |
| Контакт 4 | UP/DOWN — Counting-direction selection |
| Контакт 5 | PRESET ENABLE — Preset-enable control |
| Контакт 6 | JAM 1 — Individual jam input for the first counter stage |
| Контакт 7 | JAM 2 — Individual jam input for the second counter stage |
| Контакт 8 | JAM 3 — Individual jam input for the third counter stage |
| Контакт 9 | JAM 4 — Individual jam input for the fourth counter stage |
| Контакт 10 | Q1 — First counter output |
| Контакт 11 | Q2 — Second counter output |
| Контакт 12 | Q3 — Third counter output |
| Контакт 13 | Q4 — Fourth counter output |
| Контакт 14 | CARRY OUT — Count overflow or carry output |
| Контакт 15 | VDD — Positive supply connection |
| Контакт 16 | VSS — Ground connection |
Типичное применение
CD4029BM подходит для 6 применениеs: Industrial Batch and Event Counting, Digital Instrumentation and Timer Logic, Frequency Division and Sequencing, Automotive and Consumer Control Modules, Digital Displays and Decimal Readouts, Education and Digital Logic Prototyping.
Industrial Batch and Event Counting
The CD4029BM fits industrial batch-counting systems because it combines four-bit binary or BCD-decade counting with programmable up/down direction, individual jam inputs, and a carry output. A sensor-conditioned clock can increment the count for each detected item, while Q1 through Q4 feed a controller or display. BCD-decade mode simplifies decimal presentation, and carry-out supports an audible, visual, or downstream overflow indication. Designers should confirm the device's operating voltage and timing limits against the machine's control environment.
Рекомендуется
Digital Instrumentation and Timer Logic
The CD4029BM is useful in digital instrumentation that counts elapsed timing intervals, events, or repeatable stimulus cycles. Its positive-edge clock input provides a defined counting transition, while the UP/DOWN input supports reversible count sequences and the JAM inputs establish an initial count. The four parallel outputs can drive display decoding, threshold comparison, or acquisition logic. In precision test equipment, keep clock routing short and provide stable bypass capacitance so counter transitions remain predictable under repetitive operation.
Рекомендуется
Frequency Division and Sequencing
The CD4029BM can divide an incoming event stream by four when configured for binary counting and can assist in wider countdown sequences through cascading and carry logic. This makes it applicable to pulse-rate reduction, step sequencing, repetitive cycle control, and programmable timing fixtures. The BINARY/DECADE selection allows the same hardware to support hexadecimal-style binary states or decimal-oriented counts. Check maximum clock frequency and output timing from the manufacturer datasheet before setting the highest practical input rate.
Рекомендуется
Automotive and Consumer Control Modules
The CD4029BM can support repeatable count-based control functions in automotive or consumer equipment, including debounced event totals, operating-cycle counting, and state progression. Its CMOS implementation, selectable counting direction, and individual jam inputs permit compact logic without a microcontroller for straightforward tasks. Selection depends on matching the supply voltage, temperature range, and timing requirements to the enclosure and load conditions. Use the manufacturer ordering table to determine whether the selected suffix is appropriate for the target environment.
Рекомендуется
Digital Displays and Decimal Readouts
The CD4029BM is well suited to decimal-oriented readouts when its BCD-decade mode is selected. The Q1 through Q4 outputs represent the current decade count and can feed decade-decoder logic for a seven-segment display. Preset and jam inputs allow a readout to start from a selected value, while the carry output can trigger rollover indication or another display stage. Account for propagation delay when decoding, and maintain consistent logic levels across the display interface to avoid visible counting errors.
Рекомендуется
Education and Digital Logic Prototyping
The CD4029BM provides a clear teaching platform for binary and BCD-decade counting, direction control, synchronous preset operation, and carry propagation. Students can observe how the four outputs change on each positive clock edge and compare binary values with decimal sequencing. The 16-pin SOIC package also fits standard breadboard and adapter-board layouts. A laboratory design should still include defined logic states, supply decoupling, and current limiting on any attached output drivers.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для CD4029BM — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | CD4029BC | MC14029BDR2G |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | onsemi |
| Package | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC |
| Counter Type | 4-stage binary or BCD-decade up/down counter | 4-stage binary or BCD-decade up/down counter | 4-stage binary or BCD-decade up/down counter |
| Counter Width | 4 bits | 4 bits | 4 bits |
| Clock Edge | Positive edge | Positive edge | Positive edge |
| Counting Modes | Binary or BCD-decade | Binary or BCD-decade | Binary or BCD-decade |
| Jam Inputs | 4 individual JAM inputs | 4 individual JAM inputs | 4 individual JAM inputs |
| Carry Functions | Look-ahead CARRY-IN and CARRY OUT | Look-ahead CARRY-IN and CARRY OUT | Look-ahead CARRY-IN and CARRY OUT |
| Logic Technology | CMOS | CMOS | CMOS |
Ключевые отличия
- Original-manufacturer sourcing option (против MC14029BDR2G)
- Same-family ordering alternative (против CD4029BC)
- Configurable counting and individual preset paths (против MC14029BDR2G)
Заметки по проектированию
Place the supply bypass capacitor immediately between the VDD and VSS pins, with a short ground return and minimal loop area. Route the CLOCK trace away from switching nodes and output drivers. Because the device contains four separate JAM inputs as well as mode and direction controls, add clear silkscreen labels and maintain adequate spacing between adjacent input nets to reduce assembly and inspection errors.
Do not leave CLOCK, CARRY-IN, BINARY/DECADE, UP/DOWN, PRESET ENABLE, or any JAM input floating. Floating CMOS inputs can oscillate or settle unpredictably, causing missed counts or unintended preset operations. Define every input during reset, use pull resistors where a control is disconnected, and review the active logic levels in the manufacturer pin-description table before programming the surrounding controller.
Keep clock edge rates and source impedance within the manufacturer's recommended conditions, especially when the counter is driven by a microcontroller or long cable. A Schmitt-trigger buffer can help if the source has slow edges or excessive bounce. When cascading counters, account for propagation delay and carry timing so that the receiving stage does not sample a transient intermediate state.
Connect VSS to the circuit ground and VDD to the same supply domain used by the interfacing logic. The bypass capacitor value and permitted ESR range must follow the manufacturer guidance for stable operation. If the counter shares a board with motors, relays, or display drivers, keep high-current return paths away from the counter ground to minimize supply bounce during switching events.
Информация о соответствии