HUB2200-S - 2200 µF Hold-up Box for VIPAC | Vicor
Артикул: HUB2200-S ✓ Активен| Кол-во | Цена за ед. | Итого |
|---|---|---|
| 1 | $195 | $195,00 |
| 10 | $178.5 | $1.785,00 |
| 25 | $168 | $4.200,00 |
| 50 | $160 | $8.000,00 |
| 100 | $152 | $15.200,00 |
HUB2200-S Обзор
Within the broader VIPAC ecosystem, the HUB2200-S plays the role of an external hold-up (energy storage) module. A VIPAC front-end is a complete AC-DC or DC front-end subsystem; the HUB2200-S bolts onto it and adds capacitance so that, when the input bus sags, the downstream converter modules see a sustained input voltage long enough to maintain regulation. This category of hold-up capacitor belongs to the larger family of bulk energy storage accessories used with modular AC-DC front-ends and DC-DC hold-up circuits. Common synonyms for these modules are "hold-up box," "hold-up capacitor," "bulk storage module," and "DC hold-up accessory."
Key features of the HUB2200-S include a 2200 µF bulk capacitance rating, a hold-up box/arm form factor of 2.858 in, and electrical/mechanical compatibility with all VIPAC-family front-end power supplies. Each module is engineered, tested, and supplied by Vicor, the original manufacturer of the VIPAC platform, ensuring that hold-up time, inrush behavior, and discharge characteristics match the front-end's published specifications. The module connects to the VIPAC via the dedicated hold-up interface on the front-end chassis and is intended to be field-replaceable without desoldering.
Technically, the HUB2200-S is built around low-ESR aluminum electrolytic capacitor technology optimized for high-energy pulse discharge rather than ripple filtering. The 2.858 in package is keyed to the VIPAC hold-up rails, providing both positive and negative polarity protection. It is specified for use across the industrial temperature range typical of VIPAC deployment and is integrated into the front-end's safety/ground scheme. Designers typically select the capacitance value to achieve a target hold-up time at a given minimum input voltage, using Vicor's published hold-up time vs. capacitance curves.
Typical applications include industrial process-control PLCs, factory-automation controllers, railway signaling electronics, military COTS power subsystems, and any VIPAC-powered system that must comply with ride-through specifications such as SEMI F47 or IEC 61000-4-11. The HUB2200-S is also used in medical and test & measurement instrumentation where brief input-voltage sags cannot be allowed to corrupt measurements or reboot processors.
When designing with the HUB2200-S, verify the VIPAC front-end variant it is mating to - different VIPAC SKUs accept different hold-up box sizes, and pairing the wrong value can either under-size hold-up time or cause the front-end's inrush limiter to interpret the capacitance as a fault. Always consult the VIPAC datasheet and the HUB2200-S installation guide before substitution.
This page synthesizes distributor pricing, alternatives sourcing notes, and practical VIPAC integration guidance not found in a single manufacturer datasheet.
Аналоги без доработки для HUB2200-S — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:
HUB1800-S
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
HUB2700-S
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
HUB3300-S
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
HUB820-S
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
HUB2200-S Максимальные параметры и электрические характеристики
| Product Type | Hold-up capacitor module (accessory) |
| Capacitance | 2200 µF |
| Compatible Platform | Vicor VIPAC family front-end systems |
| Form Factor | Hold-up box / arm |
| Body Length | 2.858 in |
| Способ монтажа | Bolts onto VIPAC front-end hold-up interface |
| Manufacturer | Vicor |
| Manufacturer Part Number | HUB2200-S |
| Accessory Type | Bulk energy storage (DC hold-up) |
| Capacitor Technology | Aluminum electrolytic, low-ESR |
| Функция | Provides input dropout ride-through for VIPAC front-ends |
| Connection to Host | Dedicated keyed hold-up rails on VIPAC chassis |
| Field Replaceable | Yes (no desoldering required) |
| Compliance | Designed for use with EN55022 Class B EMI-filtering VIPAC front-ends |
| Mounting Kit | Use Vicor 21393 / 21394 / 21395 hold-up box mounting kit |
Руководство по цоколевке HUB2200-S в корпусе standard
Цоколевка для HUB2200-S (корпус standard). Этот силовой прибор имеет выводы затвора, стока и истока. Для неполяризованных корпусов обратитесь к техническому описанию производителя для точной ориентации вывода 1 и деталей посадочного места. Типичные применения включают проектирование источников питания, управление двигателями и коммутацию нагрузки.
Нет подробных данных о распиновке для HUB2200-S.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
HUB2200-S подходит для 7 применениеs: Industrial Process Control PLC Power, Factory Automation Controller Ride-Through, Railway Signaling Electronics, Military COTS Power Subsystems, Medical Instrumentation Power, Test & Measurement Instrumentation, AC-DC Front-End with EN55022 Class B Compliance.
Industrial Process Control PLC Power
The HUB2200-S bolts onto a Vicor VIPAC front-end powering industrial PLCs in process-control cabinets, where brief input-voltage sags on the AC mains must not reset the controller. The 2200 µF module provides enough bulk energy storage to ride through SEMI F47-style sags of a few line cycles, while the VIPAC front-end handles harmonic attenuation, autoranging rectification, inrush limiting, and EN55022 Class B EMI filtering. Designers select the 2200 µF value when 1800 µF is too short and 2700 µF is unnecessary, keeping cabinet temperature rise and inrush within the VIPAC's published envelope.
Рекомендуется
Factory Automation Controller Ride-Through
In factory-automation cells - robotic lines, conveyor controllers, machine-tool CNCs - a momentary mains dip can corrupt a position register or stop a production batch. The HUB2200-S provides the bulk ride-through energy at the VIPAC front-end while the downstream DC-DC converter modules continue regulating their logic rails. The 2200 µF value is engineered by Vicor to give enough hold-up time at the typical 24V-28V VIPAC bus to keep 5V/12V logic rails within regulation for the duration of common industrial sags. Mounting kits 21393/21394/21395 secure the box to the VIPAC chassis.
Рекомендуется
Railway Signaling Electronics
Railway signaling subsystems run on notoriously dirty DC bus voltages with frequent transients and brief dropouts as trains pass through substation segments. A HUB2200-S-equipped VIPAC front-end provides the surge immunity, EMI filtering to EN55022 Class B, and bulk hold-up energy required for cab signaling, interlocking, and track-circuit monitoring electronics. The 2200 µF module is sized to ride through typical 10-100 ms catenary sags without rebooting downstream processors, and its mechanical keying prevents reverse polarity installation in the field - critical for serviceability in wayside cabinets.
Рекомендуется
Military COTS Power Subsystems
Defense programs increasingly use COTS (Commercial-Off-The-Shelf) power front-ends, and the VIPAC + HUB2200-S combination is a known COTS building block for vehicle and shelter electronics. The HUB2200-S extends hold-up against MIL-STD-704 and MIL-STD-1275 transient and dropout conditions on the 28V DC bus, while the VIPAC handles EMI, inrush limiting, and converter enable signaling for downstream DC-DC modules. The 2.858 in hold-up box size is standardized across the HUB family, allowing procurement flexibility between HUB1800-S, HUB2200-S, HUB2700-S, and HUB3300-S without redesigning the chassis cutout.
Рекомендуется
Medical Instrumentation Power
Patient-monitoring and diagnostic-imaging equipment cannot tolerate mains sags that reset microprocessors or interrupt data acquisition. The HUB2200-S on a VIPAC front-end gives the bulk energy needed to bridge typical hospital-grade mains events, while the VIPAC's EN55022 Class B EMI filtering and overvoltage protection keep the input bus clean. The 2200 µF value is appropriate for monitoring-station power budgets; medical-imaging modalities that need longer hold-up should step up to HUB2700-S or HUB3300-S on the same VIPAC chassis.
Рекомендуется
Test & Measurement Instrumentation
Bench and ATE (Automatic Test Equipment) power subsystems built on VIPAC front-ends need clean hold-up behavior so that a brief mains event does not corrupt a long-running measurement. The HUB2200-S delivers the bulk storage sized for typical ATE hold-up targets, and the VIPAC's converter enable/status signaling lets the system signal 'input loss imminent' to the host controller via the HUB discharge curve. Because the HUB2200-S shares its form factor with the rest of Vicor's hold-up box family (HUB1800-S / HUB2200-S / HUB2700-S / HUB3300-S), engineers can standardize on a single chassis cutout and slot in different capacitance values for different product variants.
Рекомендуется
AC-DC Front-End with EN55022 Class B Compliance
Designers who need a complete AC-DC front-end with EN55022 Class B EMI compliance, autoranging rectification, inrush current limiting, overvoltage protection, and converter enable/status signaling often build on a VIPAC. Adding the HUB2200-S bolsters input-voltage ride-through so the downstream DC-DC converter modules continue running during mains sags. The HUB2200-S matches the VIPAC's keyed hold-up interface and is installed using one of Vicor's 21393, 21394, or 21395 mounting kits. This combination is a common COTS building block for telecom, datacom, and process-control OEMs.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для HUB2200-S — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | HUB1800-S | HUB2700-S | HUB3300-S | HUB820-S |
|---|---|---|---|---|---|
| Brand | Vicor | Vicor | Vicor | Vicor | Vicor |
| Package | Vicor VIPAC hold-up box (2.858 in) | Vicor VIPAC hold-up box (2.858 in) - same | Vicor VIPAC hold-up box (2.858 in) - same | Vicor VIPAC hold-up box (2.858 in) - same | Vicor VIPAC hold-up box (2.858 in) - same |
| Capacitance | 2200 µF | 1800 µF (-18%) | 2700 µF (+23%) | 3300 µF (+50%) | 820 µF (-63%) |
| Compatible Platform | Vicor VIPAC family | Vicor VIPAC family | Vicor VIPAC family | Vicor VIPAC family | Vicor VIPAC family |
| Mounting Style | Bolts onto VIPAC front-end hold-up interface | Bolts onto VIPAC front-end hold-up interface - same | Bolts onto VIPAC front-end hold-up interface - same | Bolts onto VIPAC front-end hold-up interface - same | Bolts onto VIPAC front-end hold-up interface - same |
| Field Replaceable | Yes (no desoldering) | Yes | Yes | Yes | Yes |
| Capacitor Technology | Aluminum electrolytic, low-ESR | Aluminum electrolytic, low-ESR | Aluminum electrolytic, low-ESR | Aluminum electrolytic, low-ESR | Aluminum electrolytic, low-ESR |
| Relative Hold-up Time (at fixed Vin_min) | 1.00x (reference) | 0.82x (-18%) | 1.23x (+23%) | 1.50x (+50%) | 0.37x (-63%) |
Ключевые отличия
- Same VIPAC drop-in slot, 22% more ride-through than HUB1800-S (против HUB1800-S)
- Same VIPAC drop-in slot, 23% less inrush stress than HUB2700-S (против HUB2700-S)
- Vicor-validated discharge curve matched to VIPAC front-end (против Generic 2200 µF capacitor (NOT approved))
Заметки по проектированию
Do NOT substitute a generic 2200 µF capacitor for the HUB2200-S. The module is a keyed, chassis-bonded accessory whose discharge curve is matched to the VIPAC front-end's inrush limiter and safety/ground scheme. Substituting an unapproved capacitor can defeat inrush current limiting, change hold-up time in non-obvious ways, and potentially violate the VIPAC's EN55022 Class B and overvoltage-protection certifications. Always use a Vicor-qualified HUB module and one of the 21393/21394/21395 mounting kits.
Estimated: at typical VIPAC bus voltages and a few ride-through events per hour, the HUB2200-S contributes small additional dissipation on top of the front-end's own losses. In a sealed IP65 enclosure without forced airflow, confirm that ambient temperature inside the cabinet does not exceed the VIPAC derating curve. For installations in unventilated wayside railway cabinets or sealed military shelters, consider derating the VIPAC output or specifying an extended-temperature HUB variant from Vicor.
The HUB2200-S is not PCB-mounted - it is a chassis-mounted hold-up box/arm bolted to the VIPAC front-end. Provision chassis cutout per the VIPAC installation guide, use Vicor mounting kit 21393 / 21394 / 21395, and torque to the specified value. Leave service clearance on both rails so the module is field-replaceable without removing the VIPAC from the cabinet. Note that the HUB family shares mechanical keying; verify polarity orientation before tightening the hold-down bolts to avoid reversed-polarity installation.
When sizing hold-up time, use Vicor's published hold-up-time vs capacitance curves for the specific VIPAC front-end variant. As a rule of thumb, hold-up time scales roughly linearly with capacitance at a fixed minimum input voltage. If your design requires a hold-up time that the 2200 µF HUB2200-S cannot meet, step up to HUB2700-S or HUB3300-S on the same VIPAC chassis without changing the cutout. Conversely, if you are over-specifying, step down to HUB1800-S to reduce inrush stress on the VIPAC front-end.
Информация о соответствии
RoHS and REACH compliance inferred from Vicor accessories product page (https://www.vicorpower.com/accessories/capacitors). Halogen-free and conflict-minerals documentation should be requested from Vicor or the franchised distributor for project-critical declarations.