ICS601G-21 - 220MHz Low Phase Noise Clock Multiplier | Renesas
Артикул: ICS601G-21 ✓ АктивенICS601G-21 Обзор
A clock multiplier is a clock-and-timing IC that generates one or more related output clocks from an input reference. It sits within the broader clock generation and frequency synthesis hierarchy, where clock generator ICs, phase-locked loops, and multipliers provide stable timing references for digital logic, serial links, converters, and communication transceivers. The ICS601G-21 is positioned as a low-cost, low-phase-noise, high-performance multiplier for designs where timing quality is important.
The primary performance benefit is clock multiplication with low phase noise. Lower phase noise can reduce timing uncertainty in high-speed digital paths, while low jitter is valuable for clocking oscillators, converters, communication interfaces, and sampling systems. The 220 MHz maximum frequency also allows the multiplier to support demanding clock trees where the input reference operates below the final required output frequency. The 16-TSSOP surface-mount package supports compact PCB layouts and automated manufacturing.
The device uses CMOS-compatible signals and a 3.0 V to 3.6 V supply range. These characteristics make it straightforward to pair with modern 3.3 V logic when signal levels, timing margins, and output-drive requirements are compatible. Designers should confirm the input and output frequency ranges, output configuration, clock-edge relationship, and load requirements from the manufacturer datasheet before finalizing a circuit.
Typical uses include low-skew clock distribution for embedded processors, frequency generation for communication equipment, clocking in industrial automation systems, and reference-clock multiplication in test and measurement designs. In a fanout arrangement, the multiplier can create related clock outputs that are easier to distribute than attempting to fan out a high-frequency source directly. This approach helps preserve clock quality across multiple loads when the board layout is designed carefully.
PCB layout is critical for any low-noise timing circuit. Keep the reference input, multiplier output, supply connections, and decoupling capacitors short, and route clock traces away from high-current switching nodes and noisy digital signals. Provide local supply bypassing and use a controlled ground return path to reduce power-supply noise and crosstalk. The device can be considered for industrial or communications designs, but qualification requirements for automotive, aerospace, or other specialized environments must be confirmed separately.
The ICS601G-21 is a compact clock-and-timing solution for designs that need a multiplier with a 220 MHz maximum frequency, CMOS interfaces, and a 16-TSSOP package. Its low phase-noise positioning is useful when the clock source must be multiplied before distribution or when a system requires cleaner timing than a simple divider or general-purpose clock source provides. Final selection should account for the required multiplication ratio, output frequency, jitter, load capacitance, supply voltage, and clock-tree topology.
Аналоги без доработки для ICS601G-21 — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
ICS601G-21T
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
601G-21LF
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
ICS601G-01T
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
ICS601G-21 Характеристики
| Device Type | Clock/Frequency Synthesizer, Clock Generator IC |
| Функция | Clock multiplier |
| Maximum Frequency | 220 MHz |
| Multiplication Ratio | 1 to 5 |
| Supply Voltage Range | 3.0 V to 3.6 V |
| Logic Type | CMOS |
| Корпус | 16-TSSOP, 0.173 inch width, 4.40 mm width |
| Тип монтажа | Surface Mount |
Руководство по цоколевке ICS601G-21 в корпусе 16-tssop, 0.173 inch width, 4.40 mm width
Цоколевка для ICS601G-21 (корпус 16-tssop, 0.173 inch width, 4.40 mm width). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.
Нет подробных данных о распиновке для ICS601G-21.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
ICS601G-21 подходит для 6 применениеs: Processor Clock Fanout, Communication Interface Clocking, Industrial Control Timing, Sampling and Data Acquisition, Test and Measurement Equipment, Low-Skew Clock Distribution.
Processor Clock Fanout
The ICS601G-21 is appropriate for distributing related processor clocks when the design needs multiplication rather than independent frequency generation. Its 1-to-5 multiplier range and listed 220 MHz maximum frequency allow a lower-frequency reference to be multiplied before it reaches multiple digital loads. The 16-TSSOP package keeps the device compact, while CMOS signaling supports integration with 3.3 V logic. Place the reference and clock outputs close to their destinations, use short traces, and maintain a continuous return path to limit skew and supply noise.
Рекомендуется
Communication Interface Clocking
The ICS601G-21 can support communication systems that require a multiplied reference clock with low phase noise and low jitter. The verified description specifically identifies low phase noise, low jitter, and low-skew fanout as target characteristics, making the part relevant to serial links, transceivers, and clock-recovery blocks. Its 220 MHz maximum frequency and 1-to-5 ratio provide a straightforward way to derive a higher clock from an established reference. Validate output drive, load capacitance, and interface timing before integrating it with a specific communications device.
Рекомендуется
Industrial Control Timing
Industrial controllers often need a dependable reference clock distributed across processing, conversion, and communications subsystems. The ICS601G-21's CMOS interface, 3.0 V to 3.6 V supply range, 1-to-5 multiplication capability, and 220 MHz maximum frequency make it a candidate for compact 3.3 V control boards. The low-phase-noise description can help preserve timing quality in demanding digital systems. Keep the clock network isolated from switching power stages and motor-control nodes, and verify operating-temperature requirements against the specific system enclosure.
Рекомендуется
Sampling and Data Acquisition
The ICS601G-21 can be used where a stable, multiplied clock is needed by sampling or data-conversion systems. Low phase noise and low jitter are useful when the clock contributes directly to sampling timing, while the 1-to-5 ratio allows a common reference to produce several derived timing domains. The listed 220 MHz ceiling provides useful design headroom for moderate-speed conversion systems. The engineer should confirm output frequency limits, jitter, and load capacitance in the manufacturer datasheet and account for trace and connector delay in the sampling architecture.
Рекомендуется
Test and Measurement Equipment
The ICS601G-21 is suitable for test and measurement equipment that needs a low-noise reference multiplied into a higher-rate clock. The compact 16-TSSOP package supports dense instrument layouts, and the device's stated low-phase-noise, low-jitter characteristics are valuable for coherent signal generation, digitizers, and calibration systems. A 3.3 V supply operation simplifies interface with modern CMOS logic. Keep sensitive clock routing away from relay drivers, power-converter switches, and display circuitry, and validate the final timing margin across temperature and supply tolerance.
Рекомендуется
Low-Skew Clock Distribution
The ICS601G-21 is designed with low-skew fanout as a target use case, allowing a multiplied clock to feed several destinations more effectively than direct high-frequency fanout. This makes it relevant to digital backplanes, control logic, and multi-channel clock trees where timing alignment affects system behavior. The 16-TSSOP package provides a small footprint, while the 220 MHz maximum frequency supports common digital clocking rates. Preserve matching topology and ground references between outputs, and use controlled impedance routing when the clock edges have high significance.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для ICS601G-21 — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | ICS601G-21T | 601G-21LF | ICS601G-01T |
|---|---|---|---|---|
| Brand | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics |
| Package | 16-TSSOP, 0.173 inch width, 4.40 mm width | 16-TSSOP, 0.173 inch width, 4.40 mm width | 16-TSSOP, 0.173 inch width, 4.40 mm width | 16-TSSOP |
| Device Type | Clock/Frequency Synthesizer, Clock Generator IC | Clock Multiplier | Clock/Frequency Synthesizer, Clock Generator IC | Clock Multiplier |
| Surface Mount Package | Yes | Yes | Yes | Yes |
Ключевые отличия
- Directly identified as a low-phase-noise 1-to-5 clock multiplier (против ICS601G-01T)
- Confirmed 220 MHz maximum frequency in the same 16-TSSOP footprint (против 601G-21LF)
- Exact catalog identity with a 16-TSSOP clock-generator listing (против ICS601G-21T)
Заметки по проектированию
Keep the reference input, multiplier outputs, supply pins, and decoupling capacitors close to the ICS601G-21. Route clock traces as controlled-impedance paths where edge rate matters, maintain a continuous ground reference beneath the clock network, and avoid crossings with switching-regulator, motor-drive, and high-speed data paths. For multiple outputs, preserve symmetrical routing where skew is critical.
Do not assume that two devices with the same 16-TSSOP outline are automatically interchangeable. Confirm the manufacturer pinout, input and output frequency limits, multiplication ratio, supply range, output-drive capability, and load capacitance for ICS601G-21T, 601G-21LF, or ICS601G-01T before replacing the target. Validate the complete clock tree at the intended input frequency, load, and operating temperature.
Place the local bypass capacitor at the supply pins with a short, low-inductance connection and provide adequate ground return. Although the listed operating range is 3.0 V to 3.6 V, clock noise and supply ripple can affect phase noise and jitter. Review the manufacturer recommendations for bypass capacitance and use a quiet reference source when the downstream circuit has demanding timing requirements.
Информация о соответствии
Compliance information is not stated in the verified manufacturer or distributor material.