УВЕДОМЛЕНИЕ О ПОСЛЕДНЕЙ ЗАКУПКЕ: MAX232IDW приближается к снятию с производства. Последняя дата заказа: Свяжитесь с нами. Смотреть доступные аналоги →
Texas Instruments

MAX232IDW - 120kbps Dual RS-232 Transceiver | Texas Instruments

Артикул: MAX232IDW ⚠ Последняя закупка
5 V Vdss 8 mA typical Id 16-pin SOIC Package
MOQ: 1 |

MAX232IDW Обзор

Texas Instruments MAX232IDW is a dual RS-232 line-driver and receiver transceiver with two transmit channels and two receive channels, a maximum data rate of 120 kbps, and a 16-pin SOIC package. It operates from a single 5 V supply and uses an on-chip capacitive voltage generator to produce RS-232-level output voltages from approximately ±9 V.

An RS-232 transceiver is an interface IC that converts logic-level signals between TTL/CMOS equipment and the voltage-defined RS-232 interface. The MAX232 belongs to the RS-232 interface transceiver family, which sits within interface ICs and broader semiconductor communication components. Its integrated charge pump reduces the external component count compared with discrete RS-232 implementations.

The device supports data rates up to 120 kbps and includes two drivers plus two receivers for bidirectional serial links. Its receiver can accept input levels up to ±30 V, which provides margin for ±15 V RS-232 signaling and transient conditions. The stated receiver threshold is typically 1.3 V with 0.5 V hysteresis. Texas Instruments identifies ±9 V outputs and ±2 kV ESD protection as principal product features.

Because MAX232IDW accepts a 4.5 V to 5.5 V supply, downstream circuitry must already have a compatible 5 V rail. It cannot directly operate from a 3.3 V system supply. The on-chip voltage converter requires external charge-pump capacitors, while normal system design also needs connection protection, grounding, and cable-routing consideration. Its typical supply current is 8 mA, making it suitable for established 5 V industrial, instrumentation, and embedded-control interfaces.

Typical uses include legacy RS-232 ports on test equipment, industrial controllers, serial adapters, service interfaces, and embedded systems that communicate with older peripherals. Two driver/receiver pairs support one or more duplex channels without adding separate line-driver ICs. The device is also suited to legacy industrial equipment where RS-232 remains the established service or configuration interface.

For a new design, verify that the connector and cable carry RS-232 bipolar voltage rather than RS-485 differential signaling. Place the charge-pump capacitors close to their designated pins and use a low-impedance ground return for reliable receiver operation. If the system supply is 3.3 V, choose a specifically rated 3.3 V-compatible transceiver instead of adding an unnecessary regulator solely for MAX232IDW.

This product data combines manufacturer specifications, lifecycle information, and cross-reference results with practical interface-design guidance. The comparison and drop-in guidance distinguish package compatibility from functional similarity, helping engineers avoid substitutions that require PCB changes or revised power-supply and protection schemes.

Аналоги без доработки для MAX232IDW — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с MAX232IDW (тот же форм-фактор и посадочное место) — отличается по ESD Protection, Product Type, Maximum Data Rate, Interface Standard, Package.

Texas Instruments
ESD Protection: ±15 kV
Product Type: Dual RS-232 line driver and receiver
Maximum Data Rate: 120 kbit/s
Сравнить с MAX232IDW →
Texas Instruments
ESD Protection: 8 mA typical; protection specification shown in retrieved data
Сравнить с MAX232IDW →
Texas Instruments
Product Type: Dual RS-232 driver/receiver transceiver
Maximum Data Rate: 120 kbit/s
Сравнить с MAX232IDW →
Texas Instruments
Product Type: Dual RS-232 driver/receiver transceiver
Maximum Data Rate: 250 kbps
Interface Standard: RS-232
Сравнить с MAX232IDW →
Texas Instruments
ESD Protection: ±15 kV IEC 61000-4-2
Product Type: Dual RS-232 driver/receiver
Maximum Data Rate: 250 kbps
Сравнить с MAX232IDW →
Analog Devices
Product Type: RS-232 transceiver interface IC
Interface Standard: EIA/TIA-232E and CCITT V.28
Сравнить с MAX232IDW →

MAX232ESE+T

✅ Прямая замена
Analog Devices
📦 SOIC-16
RS-232 transceiver interface IC · 2 drivers and 2 receivers · 4.5 V to 5.5 V · 120 kbps · EIA/TIA-232E and CCITT V.28 · V.28 and V.24 · On-chip capacitive voltage generator · 16 pins

Уточнить цену

Открыть даташит →

MAX232EWE

✅ Прямая замена
📦 SOIC-16
0% measurable primary-parameter difference reported for the compared MAX232EWE variant; order-code terms require confirmation

📋 Справочный аналог (нет в каталоге)

MAX232DG4

✅ Прямая замена
Texas Instruments
📦 SOIC-16
Dual EIA-232 driver and receiver · 2 · 2 · Full duplex · 120 kbit/s · 4.5 V to 5.5 V · 1.0 µF integrated · ±30 V

Уточнить цену

Открыть даташит →

MAX232ECDW

✅ Прямая замена
Texas Instruments
📦 SOIC-16
Dual RS-232 driver/receiver transceiver · 2 drivers · 2 receivers · RS-232 · 4.5 V to 5.5 V · 250 kbps · 1.3 V typical · IEC 61000-4-2

Уточнить цену

Открыть даташит →

MAX202CDWR

✅ Прямая замена
Texas Instruments
📦 SOIC-16
Dual RS-232 line driver and receiver · 2 · 2 · 5 V · 120 kbit/s · ±9 V · ±15 kV · Serial-port connection pins, including GND

Уточнить цену

Открыть даташит →

MAX232IDW Характеристики

Transceiver Configuration 2/2 dual driver and receiver
Number of Drivers 2
Number of Receivers 2
Maximum Data Rate 120 kbps
Nominal Supply Voltage 5 V
Supply Voltage Range 4.5 V to 5.5 V
Выходное напряжение ±9 V
Receiver Maximum Input Voltage ±30 V
Receiver Threshold 1.3 V typical
Receiver Hysteresis 0.5 V typical
ESD Protection ±2 kV
Ток потребления 8 mA typical
Диапазон рабочих температур -40°C to +85°C
Корпус 16-pin SOIC
Тип монтажа Surface mount
Interface Standard TIA/EIA-232-F
Recommendation ITU Recommendation V.28
RoHS Classification RoHS3
Статус жизненного цикла Last time buy

Руководство по цоколевке MAX232IDW в корпусе 16-pin soic

Цоколевка для MAX232IDW (корпус 16-pin soic). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.

Схема цоколевки корпуса 16-pin soic для MAX232IDW

Нет подробных данных о распиновке для MAX232IDW.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

MAX232IDW подходит для 6 применениеs: Legacy Industrial Control Interfaces, Test and Measurement Equipment, Embedded Serial Adapters, Instrumentation and Control Panels, Serial Communication Test Equipment, Appliance and Service Communications.

🏭

Legacy Industrial Control Interfaces

The MAX232IDW fits legacy industrial controllers that expose a service or configuration port using conventional RS-232. Its two drivers and two receivers support bidirectional communication from one 16-pin SOIC device, while the 120 kbps maximum data rate is appropriate for parameter uploads, diagnostic commands, and configuration exchanges. The 4.5 V to 5.5 V supply requirement means the controller must already provide a stable 5 V rail. For long field cables, retain the device’s specified ±2 kV ESD protection but add application-appropriate surge and overvoltage protection. Use a low-impedance signal-ground return to keep receiver thresholds reliable.

🔧

Test and Measurement Equipment

The MAX232IDW is suitable for RS-232 service ports on oscilloscopes, analyzers, programmable instruments, and laboratory equipment. Its receiver input capability extends to ±30 V, providing margin for bipolar RS-232 signaling, while the 120 kbps rate supports command and measurement-data links that do not require high-speed serial protocols. The device converts bipolar line signals into 5 V TTL/CMOS levels for embedded control logic and uses its integrated voltage generator to produce approximately ±9 V driver outputs. Verify connector pin assignments, grounding, and any external cable protection against the manufacturer data before connecting equipment to long or electrically noisy environments.

🖥️

Embedded Serial Adapters

MAX232IDW can provide the RS-232 physical layer in embedded systems that must connect a 5 V controller or microcontroller UART to a legacy PC, peripheral, or service interface. Two transmit and two receive channels allow a duplex link and spare serial lines without multiple single-channel transceivers. The 8 mA typical supply current is reasonable for a 5 V industrial or appliance platform, but the part is not a direct fit for a 3.3 V-only system. Confirm the UART logic levels, use the manufacturer charge-pump capacitor values, and place protection components close to the connector so electrostatic-discharge currents do not traverse sensitive board areas.

📟

Instrumentation and Control Panels

The MAX232IDW fits instrumentation panels and controller boards that retain an RS-232 commissioning interface alongside more modern communications. The 16-pin SOIC package supports compact surface-mount layouts, and the -40°C to +85°C range covers many industrial environments. Its ±9 V driver output and ±30 V receiver input capability provide compatibility with standard bipolar RS-232 signaling. Because the device requires a 5 V rail and external charge-pump capacitors, reserve the correct board area and follow the recommended layout. For exposed installations, supplement the specified ±2 kV ESD protection with properly selected surge and overvoltage components.

📡

Serial Communication Test Equipment

The MAX232IDW can be used in bench fixtures and communication test adapters that translate between 5 V logic and RS-232. Its 120 kbps operating rate is sufficient for many legacy configuration and diagnostic protocols, while two transmitter and two receiver channels simplify multi-signal test access. Use a receiver threshold of 1.3 V typical and 0.5 V typical hysteresis as part of interface-margin assessment, while recognizing that actual noise immunity also depends on cabling and grounding. Place interface protection at the connector boundary, and avoid substituting a 3.3 V-only transceiver without verifying receiver and driver compatibility with the equipment under test.

🔌

Appliance and Service Communications

MAX232IDW is appropriate for appliances, printers, scanners, and service equipment that expose an RS-232 diagnostic port. The two-channel transceiver arrangement supports a bidirectional service link and allows one channel to be reserved for hardware-handshake signals when required. Its single 5 V supply and integrated capacitive voltage generator simplify the interface compared with a discrete driver implementation, although the charge-pump capacitors remain mandatory. The last-time-buy lifecycle status makes replacement planning important for new production designs; engineers should evaluate a documented same-family alternative or a 3.3 V-compatible transceiver where the broader system architecture permits it.

What are the key specifications of MAX232IDW that engineers should know?
The MAX232IDW is a dual RS-232 transceiver with two drivers, two receivers, a 120 kbps maximum data rate, and a 16-pin SOIC package. According to the Texas Instruments MAX232 product page, it operates from a 4.5 V to 5.5 V supply, provides ±9 V outputs, and includes ±2 kV ESD protection. The device also uses an on-chip capacitive voltage generator, allowing bipolar RS-232 levels to be produced from one 5 V supply. Typical supply current is 8 mA, and the specified operating-temperature range is -40°C to +85°C.
Where can I download the MAX232IDW datasheet PDF?
The official MAX232IDW documentation is available through the Texas Instruments MAX232 product page, with the manufacturer product page listed as the authoritative source. The device is also described as a dual EIA-232 driver and receiver, so the MAX232 datasheet applies to MAX232IDW. Engineers should use the manufacturer's pin-description and electrical-characteristics tables when assigning PCB tracks or calculating interface margins. The MAX232IDW data-sheet PDF mirror is also listed on the page, but the Texas Instruments source should be preferred for revisions and lifecycle notices.
Where can I find the MAX232IDW pinout?
The MAX232IDW uses a 16-pin SOIC package, and its numbered pin assignments and standard counterclockwise numbering are shown in the Texas Instruments MAX232 datasheet. Use that pin-description table to identify the supply pins, charge-pump capacitor terminals, driver outputs, and receiver inputs before routing the PCB. The MAX232IDW search result specifically identifies a 16-SOIC package, while the package diagram on this page uses the soic-16 outline. Pin-level net names should therefore be checked against the manufacturer datasheet rather than inferred from another interface IC.
Is the MAX232IDW compatible with 3.3 V logic and supply?
The MAX232IDW is intended for a 4.5 V to 5.5 V supply and does not directly support a 3.3 V supply. Its receivers convert bipolar RS-232 signals to 5 V TTL/CMOS levels, so a system powered from 3.3 V should use a transceiver explicitly designed for 3.3 V operation. Adding a 5 V regulator solely for MAX232IDW can increase board area, power consumption, and heat dissipation. The device remains appropriate when the equipment already includes a stable 5 V rail and the connected equipment uses a conventional RS-232 interface.
What RS-232 standards does the MAX232IDW meet?
The MAX232IDW is described as meeting or exceeding TIA/EIA-232-F and ITU Recommendation V.28. According to the Texas Instruments MAX232 documentation, each receiver converts TIA/EIA-232-F inputs into 5 V TTL/CMOS levels, while the capacitive voltage generator supplies bipolar line voltages from a single 5 V supply. Compliance with the interface specification does not remove the need for correct connector wiring, a shared ground reference, suitable cable routing, and application-level protection against electrostatic discharge.
How much current does the MAX232IDW consume?
The MAX232IDW has a typical supply current of 8 mA. This figure applies to the 5 V-powered RS-232 transceiver function and should be considered alongside the charge-pump capacitor requirements and the load presented by connected logic circuitry. The manufacturer documentation identifies operation from a single 5 V supply as a principal feature. For battery-powered or energy-limited equipment, the 8 mA operating demand and the need for a 5 V rail can make a native 3.3 V interface device a better architectural choice.
What can replace the MAX232IDW on the same 16-pin SOIC footprint?
Several MAX232-family devices appear as close replacement candidates for the MAX232IDW, including MAX232ESE+T, MAX232EWE, MAX232DG4, MAX232ECDW, and MAX202CDWR in the cited comparison material. The MAX232ESE+T and MAX232EWE comparisons report no measurable differences in their principal technical parameters, while MAX202CDWR has the same two-driver and two-receiver arrangement. Before replacing the device, confirm supply range, temperature grade, electrical limits, shutdown behavior, and every pin connection in the manufacturer datasheet. A similar function does not automatically guarantee complete drop-in equivalence.
What is the best drop-in replacement for MAX232IDW?
The MAX232ESE+T is the closest cited drop-in candidate for MAX232IDW because its comparison reports no measurable difference in the principal technical parameters. MAX232EWE is another close match, while MAX232DG4 and MAX232ECDW are same-family candidates that require parameter review. MAX202CDWR shares the 16-pin SOIC format and 2/2 transceiver organization but may differ in electrical characteristics. The final choice should be based on the manufacturer datasheet rather than the package name alone, especially for industrial temperature, ESD, supply-current, and receiver-threshold requirements.
Can MAX202CDWR replace MAX232IDW without changing the PCB?
MAX202CDWR is a possible 16-pin SOIC drop-in candidate because the comparison material presents it alongside MAX232IDW and both devices provide a dual-driver and dual-receiver arrangement. However, its detailed electrical differences are not stated in the comparison snippets, so the MAX202CDWR datasheet must be checked for supply voltage, data rate, receiver thresholds, ESD rating, and pin-level behavior. Do not assume interchangeability solely from the shared package and line count. The match should be rated at approximately 80% until those manufacturer specifications are verified.
Is MAX232IDW the same as MAX232ESE+T?
MAX232ESE+T is reported as having no measurable primary-parameter difference from MAX232IDW, making it the strongest same-family replacement candidate in the cited comparisons. Both occupy the 16-pin SOIC format and implement a dual RS-232 driver/receiver interface. The order-code suffixes can still indicate temperature, packaging, or qualification differences, so confirm the complete ordering information and environmental requirements before approving a substitution. A final cross-check against both Texas Instruments datasheets remains necessary for production use.
MAX232IDW vs MAX232DG4: which is better for an industrial control port?
Choose MAX232IDW when you specifically require its documented 120 kbps rate, ±2 kV ESD rating, and -40°C to +85°C operating range. MAX232DG4 is a same-family 16-pin SOIC comparison candidate, but the cited material does not quantify every operating parameter difference. For an industrial control port, review supply current, receiver threshold, ESD level, temperature grade, and shutdown or fault behavior in both manufacturer datasheets. The available comparison does not justify claiming that one part is universally superior, so application requirements should determine the final selection.
When should I choose MAX232IDW over MAX232ESE+T?
Choose MAX232IDW when the order code, temperature grade, qualification status, and lifecycle commitment are already validated for the design. Choose MAX232ESE+T when its orderable package and qualification fit the assembly process and the cross-reference comparison shows no meaningful primary-parameter change. Both use the 16-pin SOIC format and provide the same fundamental dual-driver, dual-receiver RS-232 function. Before exchanging them, verify lifecycle status because MAX232IDW is identified as last time buy, making a documented transition path important for ongoing production.
Is MAX232IDW suitable for legacy industrial equipment interfaces?
The MAX232IDW is suitable for legacy equipment that uses a conventional 5 V RS-232 service port. Its two drivers and two receivers, 120 kbps data rate, ±30 V receiver input capability, and -40°C to +85°C range fit many industrial controller and instrument interfaces. The external RS-232 connector still needs correct signal and ground wiring, and the system must provide a 4.5 V to 5.5 V rail. Use the manufacturer application guidance when adding surge, surge-current, or longer-cable protection beyond the device's specified ±2 kV ESD capability.
Where can I buy MAX232IDW and check its current lead time?
Use the Request a Quote form on this page to request MAX232IDW availability, current lead time, and a shipment quote. Because the device is identified as last time buy, buyers should also ask about remaining supply, authorized channel traceability, and lot consistency. The structured pricing area on this page provides current purchasing information without presenting a static price that may quickly become obsolete. For production planning, request a written lead-time statement and confirm whether the order will be fulfilled as a standard 16-pin SOIC tube package.
How should the MAX232IDW charge-pump capacitors be placed?
Place the MAX232IDW charge-pump capacitors close to the pins identified in the Texas Instruments pin-description table and keep their return paths short. The manufacturer specifies the use of a capacitive voltage generator, but the exact capacitor values, voltage rating, tolerance, and layout example should be taken from the MAX232 datasheet rather than copied from a generic RS-232 circuit. Keep the interface connector and protection network away from sensitive logic routing, provide a low-impedance ground reference, and verify the capacitor placement against the recommended PCB layout.

Справочные инженерные данные для MAX232IDW — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose MAX232IDW when the equipment already has a reliable 5 V rail, the external interface is conventional bipolar RS-232, and the design needs two drivers and two receivers at up to 120 kbps. MAX232ESE+T is the closest cited same-family alternative because its comparison reports no measurable primary-parameter difference, but confirm ordering, qualification, and lifecycle requirements. MAX232EWE is another close match, while MAX232DG4 and MAX232ECDW warrant a detailed datasheet comparison for ESD, receiver threshold, supply current, and temperature grade. Consider MAX202CDWR only after verifying every electrical parameter and pin function. If the board is powered from 3.3 V, a native 3.3 V-compatible transceiver is generally preferable to adding a 5 V regulator. Because MAX232IDW is identified as last time buy, production planning should include a documented alternate and a review of any changes to protection or grounding.

Сравнение с аналогами

Параметр Этот товар MAX232ESE+T MAX232EWE MAX232DG4 MAX232ECDW MAX202CDWR
Package SOIC-16 SOIC-16 SOIC-16 SOIC-16 SOIC-16 SOIC-16
Brand Texas Instruments Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated

Ключевые отличия

  • Documented 120 kbps operation with two transmit and two receive channels (против MAX202CDWR)
  • Strongest reported primary-parameter match (против MAX232ESE+T)
  • Primary ESD and voltage-level protection are explicitly specified (против MAX232DG4)
  • Broad industrial temperature coverage (против MAX232ECDW)

Заметки по проектированию

Use the Texas Instruments MAX232 datasheet layout as the authority for charge-pump capacitor values, voltage rating, and placement. Position those capacitors directly between their designated pins with short traces and a compact ground return. Keep the unprotected logic-side routing away from the connector boundary, and place any selected surge or ESD protection network at the entry point so transient current is shunted before it reaches MAX232IDW. Also maintain a continuous signal-ground path between the transceiver and the connected equipment.

MAX232IDW requires a 4.5 V to 5.5 V supply and is not a native 3.3 V part. If the system already contains a 5 V rail, place a local bypass capacitor near the device supply pins and keep the charge-pump return current compact. If the board is powered only from 3.3 V, adding a regulator solely for this transceiver increases conversion loss and component count; a native 3.3 V RS-232 device is usually the cleaner architecture. Do not treat TTL-level signals as proof that the transceiver can use a 3.3 V supply.

RS-232 and RS-485 use different signaling, connectors, and circuit arrangements. The MAX232IDW requires bipolar RS-232 voltages and a shared ground reference; it cannot connect directly to an RS-485 differential bus. Also do not exceed the documented ±30 V receiver input level or assume the internal ±2 kV ESD rating is a complete lightning, industrial-surge, or cable-fault solution. Confirm connector pin numbering, logic polarity, baud rate, data framing, and grounding before energizing the interface.

For cable-based RS-232 links, minimize common-impedance effects by connecting the interface ground near the connector and using a low-impedance ground plane. Keep long protected traces away from clocks, switching nodes, and ADC inputs. The 1.3 V typical receiver threshold and 0.5 V typical hysteresis describe the nominal decision region, but noise margin still depends on the cable environment and return path. Consider directional or surge protection when the port is user-accessible or connected to equipment outside the controlled enclosure.

Информация о соответствии

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

The product listing identifies RoHS3 compliance. No separate REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was established for MAX232IDW.

Данные проверены: 2026-11-09 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

max232id soic16 MAX232IDW datasheet MAX232IDW datasheet pdf MAX232IDW pinout MAX232IDW specifications Texas Instruments MAX232IDW MAX232IDW 120kbps RS-232 MAX232IDW SOIC-16 replacement MAX232IDW drop-in replacement MAX232IDW equivalent MAX232IDW price MAX232IDW stock MAX232IDW vs MAX232ESE+T MAX232IDW industrial RS-232 interface

Связанные компоненты & термины

Texas Instruments MAX232IDW MAX232 MAX232ESE+T MAX232EWE MAX232DG4 MAX232ECDW MAX202CDWR RS-232 transceiver RS-232 interface IC line driver line receiver dual transceiver TIA/EIA-232-F ITU Recommendation V.28 TTL CMOS capacitive voltage generator charge-pump capacitor SOIC-16 surface-mount package 120 kbps ESD protection industrial control equipment last time buy
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ