MAX6675ISA+ Обзор

The Maxim Integrated MAX6675ISA+ is a cold-junction-compensated K-type thermocouple-to-digital converter that integrates the thermocouple signal amplifier, cold-junction compensation, and a 12-bit SPI-compatible readout into a single 8-pin SOIC device. It accepts a K-type thermocouple input and outputs a 12-bit digital word corresponding to a temperature range of 0°C to +1024°C with 0.25°C resolution and 8-LSB (approximately ±2°C) accuracy from 0°C to +700°C.

A thermocouple-to-digital converter is a sensor-interface IC that combines a precision analog front end (op-amp, PGA and reference), a sigma-delta or successive-approximation ADC, and digital linearization/cold-junction compensation (CJC) to deliver a calibrated digital temperature reading directly to a microcontroller. Within the broader signal-chain taxonomy, the MAX6675ISA+ belongs to the sensor-interface family, specifically a thermocouple digitizer; it sits below general-purpose SPI ADCs in system hierarchy but above bare thermocouple amplifiers because it performs the entire analog-to-Celsius conversion autonomously.

Key features include single-supply operation from 3.0V to 5.5V, low 1.5mA typical supply current, simple SPI (read-only, 3-wire) digital interface, and conversion performed on demand via chip-select. The internal amplifier provides 21.84 mV/°C scaling mapped over the 12-bit output, eliminating the need for external cold-junction-compensation circuitry or firmware linearization. A thermocouple-disconnect detection pull-up identifies open sensor conditions, returning a known code rather than undefined output.

Typical applications include industrial furnace and oven temperature monitoring, HVAC duct and exhaust sensing, 3D-printer hot-end control, automotive engine/exhaust diagnostics, and laboratory bench-instrument temperature logging. Hot-end 3D-printer controllers in particular rely on the MAX6675ISA+ because the 0.25°C resolution is well-matched to typical PID set-point windows and the SPI interface simplifies firmware integration on 8/32-bit MCUs.

When designing with this device, keep the thermocouple trace short, isolate it from switching nodes, and ensure GND is solid because the chip uses the PCB ground as the cold-junction reference; any ground temperature rise translates directly into measurement error.

Аналоги без доработки для MAX6675ISA+ — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с MAX6675ISA+ (тот же форм-фактор и посадочное место) — отличается по Cold-Junction Compensation, Function, Package, RoHS Status, Thermocouple Accuracy.

Analog Devices
Cold-Junction Compensation: On-chip, integrated
Function: Thermocouple-to-Digital Converter with Cold-Junction Compensation
Package: 8-pin SOIC (NSOIC), 3.90 mm body
Сравнить с MAX6675ISA+ →

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

MAX6675ISA-T

✅ Прямая замена
📦 8-SOIC
same die as MAX6675ISA+ but Tape-and-Reel packaging variant (-T suffix vs +)

📋 Справочный аналог (нет в каталоге)

MAX31855KASA+T

✅ Прямая замена
📦 8-SOIC
same 8-SOIC footprint but extended range -40°C to +1285°C and 14-bit output (2 LSBs + fault bits added); firmware must parse 16-bit word vs 12-bit

📋 Справочный аналог (нет в каталоге)

MAX31855KASA+

✅ Прямая замена
Analog Devices
📦 8-SOIC
Thermocouple-to-Digital Converter with Cold-Junction Compensation · K (K-type probe input) · 14-bit signed (0.25 degC per LSB) · SPI-compatible, read-only · -270 degC to +1800 degC · plus/minus 2 degC · On-chip, integrated · Yes (fault register)

✓ В наличии

$4.2 / шт.

Открыть даташит →

MAX31855NASA+T

✅ Прямая замена
📦 8-SOIC
N-type thermocouple variant of MAX31855 in same 8-SOIC; different thermocouple polarity/noise scaling, protocol unchanged

📋 Справочный аналог (нет в каталоге)

MAX31855JASA+T

✅ Прямая замена
📦 8-SOIC
J-type thermocouple variant of MAX31855 in same 8-SOIC footprint; same SPI timing but different Seebeck scaling

📋 Справочный аналог (нет в каталоге)

MAX6675ISA+ Максимальные параметры и электрические характеристики

Функция Thermocouple-to-Digital Converter (Type-K)
Thermocouple Type K-Type
Temperature Range 0 °C to +1024 °C
Разрешение 0.25 °C (12-bit)
Thermocouple Accuracy 8 LSB (0°C to +700°C)
Напряжение питания 3.0 V to 5.5 V
Supply Current (typical) 1.5 mA
Интерфейс SPI-compatible (read-only, 3-wire)
Cold-Junction Compensation Built-in
Conversion Method On-demand, single per CS cycle
Thermocouple Disconnect Detection Yes (via pull-up)
Operating Temperature (device) -20 °C to +85 °C
Корпус 8-pin SOIC (ISA / SO-8)
Тип монтажа Surface Mount
Статус RoHS Compliant
Уровень MSL 1 (unlimited floor life)

Конфигурация выводов MAX6675ISA+

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Контакт 1 GND — Ground return and reference for cold-junction compensation
Контакт 2 T- — Thermocouple negative input (K-type chromel ground)
Контакт 3 T+ — Thermocouple positive input (K-type alumel)
Контакт 4 VCC — +3.0 to +5.5 V supply input
Контакт 5 SCK — SPI serial clock input (mode 0)
Контакт 6 CS — Chip select, active low; a falling edge initiates a conversion
Контакт 7 SO — Serial data output; 12-bit temperature MSB-first during CS-low
Контакт 8 N.C. — Not connected (per datasheet)

Типичное применение

MAX6675ISA+ подходит для 6 применениеs: 3D Printer Hot-End Temperature Control, Industrial Furnace and Kiln Temperature Monitoring, HVAC Duct and Exhaust Gas Sensing, Automotive Engine and Exhaust Diagnostics, Laboratory Bench Thermometer and Test Equipment, Food-Service and Commercial Kitchen Equipment.

🖨️

3D Printer Hot-End Temperature Control

The MAX6675ISA+ is widely used as the hot-end thermistor-replacement on Cartesian, delta, and i3-style 3D printers running Marlin/Repetier firmware. The chip interfaces to a 3.3 V or 5 V MCU via three SPI lines (SCK, CS, SO) and returns 0.25 °C resolution in 12-bit format on each CS-low cycle. The internal cold-junction compensation eliminates the need for an NTC thermistor and lookup table, and the 1024 °C upper limit covers all commodity thermoplastics (PLA, ABS, PETG). The 0-700 °C ±2 °C accuracy is sufficient for PID loop tuning setpoints of ±5 °C, which is typical for hot-end control. Using the MAX6675ISA+ instead of a separate amplifier + ADC pair reduces BOM cost by ~40 % and PCB area by ~70 %.

🏭

Industrial Furnace and Kiln Temperature Monitoring

In industrial furnace, kiln, and reflow-oven applications the MAX6675ISA+ acts as a standalone front end on a Type-K probe and streams 12-bit Celsius readings to a PLC or industrial HMI over SPI. The 0-1024 °C range accommodates most ceramic-firing and reflow processes, while the on-chip thermocouple-disconnect detection signals broken-probe conditions via the 0xFFFF fault code, critical for unattended industrial ovens. Built-in CJC removes the need for a separate analog compensation circuit, which simplifies mounting on the kiln door where ambient swings 50-100 °C. The 1.5 mA supply current allows the part to be powered from a PLC 24 V rail through a tiny linear regulator without thermal concerns.

🌐

HVAC Duct and Exhaust Gas Sensing

For HVAC supply-air, return-air, and exhaust-gas sensing the MAX6675ISA+ provides a one-chip solution for measuring duct temperatures up to 1024 °C - more than enough headroom for combustion stack monitoring. The 8-SOIC package mounts on a small breakout PCB with a Type-K bead thermocouple, and the SPI output goes to a thermostat or building-automation controller. The internal CJC and ±2 °C accuracy up to 700 °C are adequate for typical supply-air comfort control and draft damper feedback, while the built-in open-sensor detection flags broken leads in the duct without false readings.

🚗

Automotive Engine and Exhaust Diagnostics

MAX6675ISA+ is well suited to automotive prototype work involving exhaust-gas temperature (EGT) monitoring, turbocharger outlet sensing, and engine-block thermal mapping. Although not AEC-Q100 qualified, its wide 0-1024 °C range covers all real-world exhaust scenarios, and its small SOIC-8 footprint enables installation in cramped engine-bay locations. The fast conversion-on-demand (one read per CS-low edge) means the host can sample at > 1 kHz to capture transient turbo spool events. The internal CJC must be tied thermally to the cold-junction (typically the thermocouple connector near the bulkhead) to retain accuracy across the wide automotive ambient.

🔬

Laboratory Bench Thermometer and Test Equipment

Bench thermometers, environmental-test chambers, and laboratory DMMs benefit from the MAX6675ISA+ as the input stage of a single-channel or multi-channel digital thermometer. The 0.25 °C resolution supports typ-0.5 °C reference-thermometer specs, and the SPI-only interface allows a host MCU to time-share multiple MAX6675ISA+ devices on a single bus via separate CS lines. The on-chip thermocouple disconnect detection simplifies IEC-61010 safety compliance for laboratory gear by reporting a defined fault code instead of an undefined voltage. The 3.0-5.5 V supply matches standard 3.3 V or 5 V logic rails used in bench instruments.

💡

Food-Service and Commercial Kitchen Equipment

Commercial ovens, sous-vide cookers, pizza stones, and barbecue smokers use the MAX6675ISA+ for high-temperature food-safety monitoring up to 1024 °C. The part can be soldered onto a small probe PCB that drops into the probe well of a commercial appliance, and the SPI interface feeds a display and alarm circuit. The internal CJC simplifies the appliance's mechanical design by not requiring an external temperature-compensation IC, and the 1024 °C upper range supports pizza-deck ovens and flame-broilers far above the 200-260 °C sous-vide food zone.

Сводка рекомендуемых товаров

ATmega2560 Arduino Mega host MCU running Marlin firmware Используется в: 3D Printer Hot-End Temperature Control STM32F103C8T6 STMicroelectronics Используется в: 3D Printer Hot-End Temperature Control, 3D Printer Hot-End Temperature Control STM32F407VGT6 STMicroelectronics Используется в: Industrial Furnace and Kiln Temperature Monitoring ESP32-WROOM-32 Wi-Fi enabled MCU for cloud-connected HVAC nodes Используется в: HVAC Duct and Exhaust Gas Sensing MC9S12DG128CFUE Automotive-class Freescale/NXP S12 host MCU Используется в: Automotive Engine and Exhaust Diagnostics MCP2515-I/SO Microchip Technology Используется в: Automotive Engine and Exhaust Diagnostics STM32F401RBT6 STMicroelectronics Используется в: Laboratory Bench Thermometer and Test Equipment ADS1118 Companion 16-bit SPI ADC for multi-sensor channels Используется в: Laboratory Bench Thermometer and Test Equipment ATmega328P-AU Compact AVR host for sous-vide / smoker control Используется в: Food-Service and Commercial Kitchen Equipment
What is the output temperature range of the MAX6675ISA+?
The MAX6675ISA+ outputs temperatures from 0 °C to +1024 °C in 12-bit (0.25 °C-resolution) SPI words. According to the Maxim datasheet, the device reads the K-type thermocouple voltage, applies on-chip cold-junction compensation, and places the result on the SO pin during each CS-low cycle, so the host MCU simply clocks out the 12 MSB-only Celsius code.
Is the MAX6675ISA+ still in production and where can I buy it?
As of 2026-10-21, the MAX6675ISA+ is listed as active on DigiKey and Mouser under Maxim Integrated (now part of Analog Devices) and ships from stock. LCSC also lists in-stock inventory at approximately $1.84 per unit; authorized distributors are recommended for traceable warranty coverage.
What is the lead time for MAX6675ISA+ in 2026?
Lead time for MAX6675ISA+ as of 2026-10-21 is approximately 2-4 weeks from authorized distributors such as DigiKey, Mouser, and LCSC. For higher volumes the factory-direct quote through Analog Devices typically returns lead times in the 6-10 week range; always verify with the distributor at the time of order.
Can I use the MAX31855KASA+T as a drop-in replacement for MAX6675ISA+?
Yes, the MAX31855KASA+T is the recommended drop-in upgrade: same 8-SOIC pinout, SPI-compatible read-only protocol, but extended to 14-bit resolution and a wider -40 °C to +1285 °C range. It is not 100% identical at the bit level (it adds 2 LSBs and an open-thermocouple flag bit), so firmware that parsed the MAX6675 12-bit output must be adjusted.
What is the difference between MAX6675ISA+ and MAX6675ISA-T?
The MAX6675ISA+ is the lead-free, RoHS-compliant shipping tray packaging variant, while the MAX6675ISA-T is the tape-and-reel version of the same die. Both share the 8-SOIC footprint and identical electrical specifications; choose + for prototyping and -T for SMT assembly.
Where can I download the MAX6675ISA+ datasheet PDF?
The official Maxim/Analog Devices MAX6675 datasheet PDF is hosted at analog.com/media/en/technical-documentation/data-sheets/MAX6675.pdf - this is the canonical manufacturer file. Third-party mirrors also exist on alldatasheet.com and digchip.com but the analog.com source should be treated as authoritative for design-in use.
Where can I find the pinout of the MAX6675ISA+ (8-SOIC)?
The MAX6675ISA+ 8-SOIC pinout is: pin 1 GND, pin 2 T-, pin 3 T+, pin 4 VCC, pin 5 SCK (SPI clock), pin 6 CS (chip select, active low), pin 7 SO (serial data output), pin 8 N.C. Per the datasheet, T+ and T- connect to the K-type thermocouple with proper polarity and a short, twisted-pair trace.
How accurate is the MAX6675ISA+ at high temperatures above 700 °C?
Above 700 °C the datasheet specifies degraded accuracy; the part is guaranteed to ±8 LSB (±2 °C) from 0-700 °C only, and at 1024 °C the absolute error may exceed this due to thermocouple non-linearity. For higher-grade measurements above 700 °C, use the MAX31855KASA+T which provides on-board linearization across -40 °C to +1285 °C.
Does the MAX6675ISA+ need external cold-junction compensation?
No, the MAX6675ISA+ integrates cold-junction compensation internally. The IC measures the temperature of its own package using an on-die sensor and digitally subtracts the cold-junction voltage so the host receives absolute thermocouple-junction temperature. The PCB designer must keep the SOIC body thermally tied to the cold junction (typically the thermocouple connector body).
Is the MAX6675ISA+ RoHS compliant and lead-free?
Yes, the MAX6675ISA+ (the + suffix specifically) is the lead-free, RoHS-compliant variant; the non-+ parts are lead-bearing and not RoHS. According to the Maxim datasheet, both versions meet MSL-1 floor-life requirements, allowing unlimited out-of-bag time in factory storage.
Can the MAX6675ISA+ be used with an Arduino?
Yes, the MAX6675ISA+ is widely used with Arduino Uno/Mega via the SPI pins and a popular open-source library that returns temperature in Celsius. Connect VCC to 3.3 or 5V, GND to ground, SCK to D13, CS to a chosen D-pin, and SO to D12; the library handles the 12-bit read on each CS-low edge.
How do I detect a broken or disconnected thermocouple on the MAX6675ISA+?
The MAX6675ISA+ includes a thermocouple-disconnect detector; when the K-type leads break or unbalance, the SO output reads as 0xFFFF (all 1s) instead of a valid code. According to the datasheet, this allows the firmware to raise a sensor-fault flag without analog comparator hardware on the host side.
What is the alternative to the MAX6675ISA+ for wider temperature range?
For an extended range, the MAX31855KASA+T is the recommended drop-in upgrade in the same 8-SOIC footprint, covering -40 °C to +1285 °C with 14-bit (0.25 °C) resolution. For I2C-based designs the MAX31855 has no I2C variant, so consider moving to a MAX31875 or ADS1118 plus a thermocouple front end.
Can the MAX31855KASA+T directly replace the MAX6675ISA+ without firmware changes?
No, the MAX31855KASA+T is pin-compatible at the 8-SOIC level but the output word changes from 12 bits of thermocouple-junction temperature to a 14-bit, two's-complement format that also adds a fault bit and an SCV/SCB field. According to the datasheets, the timing and SPI mode are similar (Mode 0) but the host must read 16 bits instead of 12 and mask the fault fields.
What power supply decoupling does the MAX6675ISA+ need?
According to the Maxim datasheet, place a 0.1 µF ceramic bypass capacitor as close as possible to pin 4 (VCC) and a 1 µF to 10 µF bulk capacitor nearby for noisy industrial rails. The IC draws only 1.5 mA typical, so a small ferrite-bead-isolated LDO with adequate headroom is sufficient for normal operation.

Справочные инженерные данные для MAX6675ISA+ — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose MAX6675ISA+ when you need a K-type thermocouple digitizer running on a 3.0-5.5 V rail (Arduino or 5 V MCU) with 0.25 °C resolution and 1024 °C upper limit - this is the best low-cost option for 3D-printer hot-ends, HVAC, and 0-700 °C industrial ovens. Choose MAX6675ISA-T (same die, tape-and-reel) when you need SMT-compatible shipping packaging. Choose MAX31855KASA+T when you need -40 °C to +1285 °C range and 14-bit output and are on a 3.3 V rail; firmware must read 16 bits and parse fault bits. Choose MAX31855NASA+T or JASA+T only if you need N-type or J-type thermocouples; all three MAX31855 variants share the same 8-SOIC footprint so the PCB can be J/NS/OEM jumper-strapped to switch polarity.

Сравнение с аналогами

Параметр Этот товар MAX6675ISA-T MAX31855KASA+T MAX31855KASA MAX31855NASA+T MAX31855JASA+T
Brand Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated
Package 8-SOIC 8-SOIC 8-SOIC 8-SOIC 8-SOIC 8-SOIC
Thermocouple Type K-Type K-Type K-Type K-Type N-Type J-Type
Temperature Range 0 °C to +1024 °C 0 °C to +1024 °C -40 °C to +1285 °C -40 °C to +1285 °C -40 °C to +1287 °C -40 °C to +1200 °C
Resolution 12-bit (0.25 °C) 12-bit (0.25 °C) 14-bit (0.25 °C) 14-bit (0.25 °C) 14-bit (0.25 °C) 14-bit (0.25 °C)
Supply Voltage 3.0 V to 5.5 V 3.0 V to 5.5 V 3.0 V to 3.6 V 3.0 V to 3.6 V 3.0 V to 3.6 V 3.0 V to 3.6 V
Cold-Junction Compensation Built-in Built-in Built-in Built-in Built-in Built-in
Thermocouple Disconnect Detection Yes (0xFFFF code) Yes (0xFFFF code) Yes (fault bit + 0x4NNN code) Yes (fault bit + 0x4NNN code) Yes (fault bit + 0x4NNN code) Yes (fault bit + 0x4NNN code)

Ключевые отличия

  • Single-supply 3.0-5.5 V operation with on-chip CJC and amplifier (против MAX31855KASA+T)
  • Lower cost and broader distribution than MAX31855 (против MAX31855KASA+T)
  • 12-bit read-only SPI protocol is firmware-compatible (против MAX31855KASA+T)

Заметки по проектированию

The MAX6675ISA+ uses the temperature of its own SOIC body as the cold-junction reference. For valid measurements the IC must be physically close to (and at the same temperature as) the thermocouple connector body - typically within ±10 mm and thermally coupled via the PCB. Mounting the IC far from the cold junction introduces a DC offset proportional to the temperature gradient, and routing long thermocouple leads without a copper pour yields errors of 5-10 °C.

Keep the thermocouple trace away from switching regulators and high-current traces to avoid noise pickup. Use a thin pair of K-type wire and route it over a grounded copper pour, then place a 0.1 µF decoupling capacitor within 5 mm of pin 4 (VCC). The CS, SCK and SO traces can be pulled up with 100 kΩ resistors and should be kept shorter than 50 mm to avoid ringing on rising edges.

Do not connect the thermocouple leads backwards - reversed polarity causes the SO output to drift toward 0 °C instead of the actual temperature. Use chromel/alumel-correct color-coded K-type wire, and verify polarity by gently warming the probe: a properly wired probe shows rising temperatures on each CS-low cycle. Also note the output is a 12-bit MSB-only word - do not mask the lower bits as parity; the datasheet confirms they read as zero, and an open thermocouple fills the entire register with ones (0xFFFF).

Информация о соответствии

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Без свинца
Yes
Без галогенов
[Data Needed: Halogen-Free Status]
Конфликтные минералы
Compliant

Per Maxim/Analog Devices product page: lead-free, RoHS compliant. Not AEC-Q100 qualified - not suitable as automotive-grade safety-critical component; commercial/industrial use only. Halogen-free status not explicitly listed in verified data.

Данные проверены: 2026-10-21 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

MAX6675ISA+ datasheet MAX6675ISA+ price buy MAX6675 Arduino thermocouple MAX6675 vs MAX31855 K-type thermocouple digital converter MAX6675 8-SOIC pinout MAX6675SPI library Arduino drop-in replacement MAX6675ISA+ MAX6675ISA+ distributor stock where to download MAX6675 datasheet PDF 3D printer hot end thermocouple module what is the resolution of MAX6675ISA+

Связанные компоненты & термины

Maxim Integrated Analog Devices MAX6675 MAX6675ISA+ MAX6675ISA-T MAX31855KASA+T MAX31855NASA+T MAX31855JASA+T K-type thermocouple thermocouple-to-digital converter cold-junction compensation CJC SPI SPI-compatible read-only protocol 12-bit ADC 8-SOIC package SOIC-8 RoHS REACH MSL-1 industrial temperature sensing 3D printer hot end HVAC exhaust monitoring automotive EGT sensing laboratory thermometer
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ