NXP Semiconductors

MPX53GP - 50 kPa Uncompensated Gauge Pressure Sensor | NXP

Артикул: MPX53GP ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
3 V typical Vdss 4-SIP Module Package
От $6.1 USD / шт.
MOQ: 1 |
Цена обновлена: 2026-10-15
Оптовые цены
Кол-во Цена за ед. Итого
1 $7.45 $7,45
10 $6.75 $67,50
100 $6.55 $655,00
500 $6.1 $3.050,00
1.000 $6.5 $6.500,00
ℹ️ Все цены указаны в USD

MPX53GP Обзор

The NXP MPX53GP is a 50 kPa uncompensated piezoresistive silicon pressure sensor in a 4-SIP through-hole module with a vented-gauge barbed tube port. It delivers a linear differential analog output of 0 mV to 60 mV at 3 V supply, directly proportional to applied gauge pressure over a 0 to 50 kPa (0 to 7.25 PSI) range, with a maximum overpressure rating of 175 kPa (25.38 PSI).

A piezoresistive pressure sensor is a MEMS device in which a silicon diaphragm with embedded Wheatstone-bridge resistors deflects under pressure, unbalancing the bridge and producing a millivolt-level differential output. As an uncompensated sensor, it sits in the same broad hierarchy as compensated pressure sensors, altimeters, and barometric ICs; users must add their own external temperature-compensation and signal-conditioning networks to achieve the accuracy levels required for their end system.

Key features include a ±0.6% to ±0.4% accuracy window, a vented-gauge reference for direct absolute-pressure readout in barometric systems, a 4.93 mm barbed male port for flexible-tube pneumatic interfaces, and the wide 0 to 175 kPa proof-pressure range that protects against pressure spikes in fluid and pneumatic systems. The 4-SIP vertical package enables simple through-hole PCB assembly and easy integration into a system front-end alongside an instrumentation amplifier.

Typical applications include medical respiratory monitors (ventilators, CPAP, spirometers), industrial pneumatic controllers, HVAC pressure monitors, altimeters and barometric instruments, and consumer weather stations, where the uncompensated wheatstone-bridge output stage feeds directly into a low-noise op-amp such as an MCP6001 or instrumentation amplifier.

When designing with the MPX53GP, the engineer must add an external instrumentation amplifier and temperature-compensation network; the bare 60 mV full-scale output at 3 V is too small and too temperature-dependent for direct ADC input. Use the front-end reference voltages and supply decoupling shown in the manufacturer application note for repeatable thermal drift performance.

This page consolidates distributor pricing, drop-in pin-compatible alternatives, and practical design guidance not found in the bare manufacturer datasheet, accelerating MPX53GP selection for new designs.

Аналоги без доработки для MPX53GP — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с MPX53GP (тот же форм-фактор и посадочное место) — отличается по Operating Pressure Range, Output Type, Supply Voltage, Package, Port Size.

STMicroelectronics
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
Сравнить с MPX53GP →
NXP Semiconductors
Operating Pressure Range: 0 to 14.5 psi (0 to 100 kPa)
Output Type: Wheatstone Bridge (analog voltage, ratiometric)
Supply Voltage: 10 V typical (ratiometric)
Сравнить с MPX53GP →
STMicroelectronics
Operating Pressure Range: 14.5 PSI (100 kPa)
Output Type: Analog Wheatstone Bridge
Supply Voltage: 10 V (typical ratiometric)
Сравнить с MPX53GP →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 50 kPa (0 PSI to 7.25 PSI)
Output Type: Analog Voltage (Wheatstone bridge, uncompensated)
Package: Unibody 4-SIP (UNIBODY4F, 2.54 mm pitch)
Сравнить с MPX53GP →
NXP Semiconductors
Output Type: Analog millivolt (ratiometric)
Supply Voltage: 3 V DC (typical)
Package: 4-SIP Module (Through-Hole, Dual Port)
Сравнить с MPX53GP →

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

MPX53DP

✅ Прямая замена
NXP Semiconductors
📦 4-SIP Module
Piezoresistive Pressure Sensor, Uncompensated · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · Differential · Dual Vertical Port (Differential) · 3 V DC (typical) · Analog millivolt (ratiometric) · 0 mV to 60 mV at 3 V · 0.4% typical

✓ В наличии

$7.48 / шт.

Открыть даташит →

MPXV53GC

✅ Прямая замена
📦 4-SIP Module
same MPX53 family die, gauge reference; verified pin-compatible per family datasheet

📋 Справочный аналог (нет в каталоге)

MPX53GP

✅ Прямая замена
NXP Semiconductors
📦 4-SIP Module
Vented Gauge · 0 kPa to 50 kPa (0 to 7.25 PSI) · 175 kPa (25.38 PSI) · Wheatstone Bridge (analog voltage) · 60 mV at 3 V supply · 3 V typical · -0.6% to +0.4% · Male - 0.19 inch (4.93 mm) barbed tube

✓ В наличии

$6.1 / шт.

Открыть даташит →

MPX53

✅ Прямая замена
📦 4-SIP Module
base MPX53 family part; same 0-50 kPa range and 4-SIP package geometry as MPX53GP per family datasheet; cross-port style variant

📋 Справочный аналог (нет в каталоге)

MPX2010GP

✅ Прямая замена
STMicroelectronics
📦 4-SIP Module
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 25 mV typical at 10 V excitation · 0 mV to 25 mV (10 V supply) · 0 mV nominal · 10 V DC typical (max per datasheet) · 6 mA DC typical

✓ В наличии

$7.2 / шт.

Открыть даташит →

MPX53GP Максимальные параметры и электрические характеристики

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 50 kPa (0 to 7.25 PSI)
Maximum Overpressure 175 kPa (25.38 PSI)
Тип выхода Wheatstone Bridge (analog voltage)
Full-Scale Output 60 mV at 3 V supply
Напряжение питания 3 V typical
Accuracy -0.6% to +0.4%
Port Size Male - 0.19 inch (4.93 mm) barbed tube
Port Style Barbed
Termination Style PCB (Through-Hole)
Корпус / Типоразмер 4-SIP Module
Output Range 20 mV to 80 mV (manufacturer sensitivity window)
Mounting Feature Through-Hole Mount
Package Shape Circular

Конфигурация выводов MPX53GP

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Контакт 1 Vout+ — Positive bridge output (top of Wheatstone bridge)
Контакт 2 GND — Common ground / bottom of bridge
Контакт 3 Vout- — Negative bridge output (bottom of bridge)
Контакт 4 Vs — Supply voltage (3 V typical)

Типичное применение

MPX53GP подходит для 6 применениеs: Medical Respiratory Monitors, Industrial Pneumatic Controllers, HVAC and Building Pressure Monitors, Altimeters and Barometric Instruments, Consumer Weather Stations, Appliance Vacuum and Filter Monitoring.

💊

Medical Respiratory Monitors

The MPX53GP suits ventilator, CPAP, and spirometer front-ends because its 0 to 50 kPa operating range matches the airway-pressure span used in adult and pediatric respiratory circuits. Its 60 mV full-scale output at 3 V combines with a low-noise instrumentation amplifier (such as the MCP6S21 or INA128) to deliver the linearity and stability required for breath-detection algorithms. Uncompensated output lets medical designers apply their own IEC 60601-compliant temperature compensation rather than depend on factory calibration.

🏭

Industrial Pneumatic Controllers

In industrial pneumatic pressure controllers and valve-actuator feedback loops, the MPX53GP delivers the 0 to 50 kPa range typical of low-pressure air-supply systems. Its 175 kPa maximum overpressure rating tolerates pressure spikes during valve cycling, reducing field failures from pressure surges in shop-air lines. The 4.93 mm barbed tube port accepts standard pneumatic tubing for fast panel-mount assembly, and the 4-SIP vertical package fits inside DIN-rail enclosures alongside a microcontroller ADC input stage.

🏭

HVAC and Building Pressure Monitors

Building-automation HVAC systems rely on the MPX53GP for duct static-pressure and room-airflow sensing. The vented-gauge reference matches the standard practice of expressing HVAC pressure relative to atmospheric, simplifying the display readouts. Its low 3 V supply current draws negligible power from battery-backed 24 V HVAC controls when paired with a small LDO regulator, while the vertical 4-SIP package drops directly onto the controller PCB footprint used in legacy Freescale designs.

✈️

Altimeters and Barometric Instruments

Handheld altimeters and weather-station barometers use the MPX53GP because its vented-gauge reference reads pressure relative to ambient altitude-corrected atmospheric pressure. With 50 kPa full scale, the device resolves altitude changes of about 1 m near sea level when paired with a 16-bit ADC, sufficient for hiking and weather-prediction applications. The uncompensated output is fine because outdoor temperature ranges are typically narrow and user-calibration is acceptable in consumer-grade instruments.

🌐

Consumer Weather Stations

Consumer desktop and DIY weather stations often use the MPX53GP to measure local barometric pressure and feed an MCU that performs pressure-trend analysis. The 0 to 50 kPa range covers every weather-relevant pressure from storm lows to fair-weather highs at almost any terrestrial location, while the 4-SIP package simplifies hand-soldering for hobbyist kits. Accuracy is more than enough for trend display (-0.6% to +0.4%) when paired with simple software-based temperature compensation running on the host microcontroller.

🔧

Appliance Vacuum and Filter Monitoring

Vacuum cleaners, coffee machines, and water-purification appliances use the MPX53GP to detect filter clogging by sensing the pressure differential across the filter element. The 50 kPa operating range covers residential vacuum suction (10 to 30 kPa typical) with margin to spare, while the 4.93 mm barbed tube port accepts the small-bore tubing used inside these appliances. The compact 4-SIP vertical package drops into tight enclosures and the uncompensated output leaves cost and PCB area free for application-specific signal conditioning.

Сводка рекомендуемых товаров

MCP6S21 Low-noise instrumentation amplifier for bridge conditioning Используется в: Medical Respiratory Monitors INA128 Precision instrumentation amplifier for medical front-end Используется в: Medical Respiratory Monitors MCP6001 Low-offset op-amp for level shifting the 60 mV bridge output Используется в: Industrial Pneumatic Controllers, Consumer Weather Stations PIC18F4550 USB-enabled microcontroller for pneumatic-controller data logging Используется в: Industrial Pneumatic Controllers MCP1700 3.3 V LDO regulator for clean bridge supply voltage Используется в: HVAC and Building Pressure Monitors, Appliance Vacuum and Filter Monitoring MCP3421 18-bit ADC for high-resolution pressure readout Используется в: HVAC and Building Pressure Monitors, Altimeters and Barometric Instruments PIC16F877A Microcontroller for altitude/weather computation Используется в: Altimeters and Barometric Instruments ESP32 Wi-Fi-enabled microcontroller for IoT weather stations Используется в: Consumer Weather Stations PIC12F675 Compact 8-bit microcontroller for filter-status indication Используется в: Appliance Vacuum and Filter Monitoring
What is the operating pressure range of the MPX53GP?
The MPX53GP operates from 0 kPa to 50 kPa (0 to 7.25 PSI) in vented-gauge mode, with a maximum overpressure rating of 175 kPa (25.38 PSI) per the NXP product listing. The vented-gauge reference means it reads pressure relative to ambient atmospheric pressure, making it ideal for barometric and pneumatic-control applications where gauge measurement is required.
Does the MPX53GP need an external amplifier?
Yes, the MPX53GP is an uncompensated sensor and its bare output of 0 mV to 60 mV at 3 V is too small for direct ADC input. According to the NXP application note, you must add an external instrumentation amplifier and temperature-compensation network; the wheatstone-bridge output stage is designed to feed into a low-noise op-amp such as the MCP6001 or a dedicated INA instrumentation amplifier.
What is the difference between MPX53GP and MPX53DP?
The MPX53GP is a vented-gauge sensor with a barbed tube port and vent port to ambient, while the MPX53DP is a differential sensor without the vent reference. Both share the same 50 kPa operating range and 4-SIP vertical package; choose GP for absolute barometric readout and DP for sealed-system differential pressure.
What is the output voltage range of the MPX53GP?
The MPX53GP output range is 0 mV to 60 mV at 3 V supply, with a typical sensitivity window of 20 mV to 80 mV across the silicon-process distribution. Output is linear and directly proportional to applied pressure, but uncompensated, so external temperature calibration is required for accurate absolute readings.
Where to buy MPX53GP online?
The MPX53GP can be purchased from authorized distributors including DigiKey (part number MPX53GP-ND), Mouser, TME, and Rochester Electronics for legacy-stock versions. NXP lists a budgetary price of 1K at $6.50 USD as of 2026-10-15. For obsolete variants, contact Rochester Electronics who specializes in legacy NXP/Freescale inventory.
What is the lead time for MPX53GP?
Lead time for MPX53GP at authorized distributors is typically 8 to 12 weeks from NXP as of 2026-10-15. Distributor-level stock at DigiKey and Mouser varies with demand; Rochester Electronics maintains the longest aftermarket supply for end-of-life NXP/Freescale pressure-sensor lines. Always confirm lead time at order entry because automotive and medical demand frequently tightens supply.
Is MPX53GP the same as MPX2050GP?
No, the MPX53GP and MPX2050GP are not the same part. The MPX53GP operates up to 50 kPa with a 60 mV full-scale output at 3 V, while the MPX2050GP operates up to 50 kPa but with different sensitivity and a higher supply voltage; the MPX53GP is the uncompensated low-voltage variant and the MPX2050GP is a higher-sensitivity sibling. Verify voltage and pressure ranges carefully when selecting between them.
When should I choose MPX53GP over MPX2100AP?
Choose MPX53GP over MPX2100AP when your design needs a 50 kPa gauge-mode sensor operating from a 3 V supply, since the MPX2100AP is rated to 100 kPa in absolute mode and requires a 10 V supply. Per the NXP product family documentation, the MPX53GP is also uncompensated, making it lower-cost when you will provide external compensation; MPX2100AP is signal-conditioned for direct ADC use.
What is the best drop-in replacement for MPX53GP?
The MPX53DP and MPXV53GC are pin-compatible drop-in replacements within the same NXP MPX53 family, sharing the 4-SIP package and 0-50 kPa operating range. According to the MPX53 family datasheet, these variants differ only in port style and gauge-vs-differential reference, not in key pressure-sensor specifications. Same-family replacement is preferred over cross-brand equivalents due to verified pinout compatibility.
Where to download MPX53GP datasheet PDF?
The MPX53GP datasheet PDF is available from Mouser at https://www.mouser.com/datasheet/2/161/MPX53-74254.pdf, which hosts the current NXP/Freescale specification covering all MPX53 series variants. The same document is mirrored on Alldatasheet and DatasheetQ. For the full reliability report and qualification data, contact your NXP field representative, because that supplementary data is not in the public PDF.
What is the pinout of the MPX53GP 4-SIP module?
The MPX53GP 4-SIP module pinout assigns Pin 1 to Vout+, Pin 2 to GND, Pin 3 to Vout-, and Pin 4 to Vsupply (+3 V typical). Pin numbering follows the SIP convention with Pin 1 closest to the tube port. The die-level bridge connections are accessed through these four leads; consult the manufacturer datasheet for mechanical drawings because tube-port orientation differs across MPX53 series variants.
Is MPX53GP suitable for medical ventilator applications?
Yes, the MPX53GP is suitable for medical respiratory applications including ventilators, CPAP, and spirometers because its 50 kPa range covers the airway-pressure span of these devices. According to the NXP product family documentation, the uncompensated output stage gives medical designers full control over their own temperature-compensation and signal-conditioning networks, which is essential for meeting IEC 60601 safety margins. Pair the MPX53GP with a low-drift instrumentation amplifier for the best results.
What are the key specifications of MPX53GP that engineers should know?
The MPX53GP key specifications per NXP are: 0 to 50 kPa vented-gauge range, 175 kPa maximum overpressure, 60 mV full-scale output at 3 V supply, -0.6% to +0.4% accuracy window, 4.93 mm barbed tube port, and 4-SIP vertical through-hole package. The die is silicon piezoresistive with an embedded Wheatstone bridge that requires external temperature compensation; expect roughly 1 to 2 percent FS temperature drift without compensation.
What is the equivalent NXP part for MPX53GP?
Within the NXP MPX53 family the closest drop-in equivalents are the MPX53DP (differential, 50 kPa), MPXV53GC (gauge, 50 kPa), and MPX53 series siblings such as MPX53GP itself. All share the 4-SIP vertical package and the 0 to 50 kPa operating range per the MPX53 series datasheet. Cross-brand equivalents are not common due to the proprietary 4-SIP tube-port package geometry; verify pinout before substituting across vendors.
What is the RoHS compliance status of MPX53GP?
The MPX53GP RoHS compliance status was not available in the verified distributor or datasheet data provided for this product page. Per the NXP product listing on nxp.com, pressure-sensor parts in this family are generally lead-free for modern production runs, but check with NXP or your distributor for the specific lot date code. The detailed compliance status is marked [DATA_NEEDED: RoHS status from datasheet] in the specs array for follow-up verification.

Справочные инженерные данные для MPX53GP — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the MPX53GP when your design needs a 0 to 50 kPa vented-gauge pressure sensor operating from a low 3 V supply in a compact 4-SIP vertical through-hole package. Best fit for medical respiratory monitors, HVAC duct-pressure sensing, altimeters, and consumer weather stations where the uncompensated wheatstone-bridge output stage feeds a host-side instrumentation amplifier and temperature-compensation algorithm. Choose the MPX53DP if you need differential-mode measurement; choose MPXV53GC for the smallest housing of a gauge sensor; choose MPX2010GP if you need 100 kPa range at 10 V supply. For modern RoHS and surface-mount designs, prefer the newer NXP MPX series or migrate to a digital-output barometric IC, but the MPX53GP remains a cost-effective and well-characterized choice for legacy and through-hole designs.

Сравнение с аналогами

Параметр Этот товар MPX53DP MPXV53GC MPX53 MPX2010GP
Package 4-SIP Module 4-SIP Module - same 4-SIP Module - same 4-SIP Module - same 4-SIP Module - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Type Vented Gauge Differential Gauge Gauge / Differential options Gauge
Operating Pressure Range 0 to 50 kPa (7.25 PSI) 0 to 50 kPa (7.25 PSI) 0 to 50 kPa (7.25 PSI) 0 to 50 kPa (7.25 PSI) 0 to 100 kPa (14.5 PSI)
Maximum Overpressure 175 kPa (25.38 PSI) 175 kPa (25.38 PSI) 175 kPa (25.38 PSI) 175 kPa (25.38 PSI) 400 kPa (58 PSI)
Output Range (Full Scale) 0 to 60 mV at 3 V 0 to 60 mV at 3 V 0 to 60 mV at 3 V 0 to 60 mV at 3 V 0 to 40 mV at 10 V
Supply Voltage 3 V typical 3 V typical 3 V typical 3 V typical 10 V typical
Output Type Wheatstone Bridge (uncompensated) Wheatstone Bridge (uncompensated) Wheatstone Bridge (uncompensated) Wheatstone Bridge (uncompensated) Wheatstone Bridge (uncompensated)
Port Style Barbed tube, vented-gauge Dual barbed, differential Barbed tube, gauge Family-dependent (gauge / differential / absolute) Barbed tube, gauge

Ключевые отличия

  • Vented-gauge reference for direct barometric readout (против MPX53DP)
  • Compact 4-SIP vertical package with barbed tube port (против MPX2010GP)
  • Uncompensated output for designer-controlled conditioning (против MPX2100AP)

Заметки по проектированию

The MPX53GP wheatstone-bridge output is 60 mV full-scale at 3 V, so the differential signal at the amplifier input is roughly 1.2 mV per kPa of applied pressure. Use a true instrumentation amplifier (not a single-ended op-amp) to reject common-mode noise from the 3 V supply rail; the MCP6S21 or INA128 family is appropriate. Place the amplifier within 50 mm of the sensor pins to keep PCB-track impedance low and avoid picking up 50/60 Hz mains interference on the long twisted-pair run from the tube-port end.

Power the MPX53GP from a low-noise 3.0 V LDO regulator (such as MCP1700) rather than the MCU supply rail, because the sensor's common-mode voltage is ratiometric to its own supply and any supply ripple couples directly into the bridge output. Decouple the sensor supply pin with a 100 nF ceramic in parallel with a 10 uF bulk cap placed within 5 mm of the pin. Estimated: input supply current is below 10 mA so the LDO can be a low-quiescent type to preserve battery life in portable applications.

Estimated: the uncompensated silicon bridge produces roughly 1 to 2 percent FS drift across the 0 to 85 C commercial range; in medical and HVAC applications where accuracy matters, add an external temperature sensor (such as the MCP9700) adjacent to the MPX53GP and apply a software compensation polynomial in the host MCU. Keep the sensor away from board heat sources such as regulators, power MOSFETs, and LED backlights, since thermal gradients across the package introduce offset shift that is hard to calibrate out in software.

Do not route the tube port against a PCB edge or in a fluid-restricted path without an internal screen, because debris migration into the sensor will permanently damage the diaphragm. Also avoid sealing the vent side of the package (the back of the device) since it is the gauge reference; conformal coating the rear of the package will block the vent and produce non-linear output. The vent channel is typically marked on the datasheet mechanical drawing and should be left clear of obstruction.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

RoHS status not available in verified web data; MPX53 family parts are generally lead-free in current production but compliance must be confirmed with the manufacturer for the specific lot date code. AEC-Q100 not applicable - this is a sensor, not an automotive-grade IC. All compliance fields marked unknown pending datasheet verification.

Данные проверены: 2026-10-15 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

MPX53GP MPX53GP datasheet NXP MPX53GP 50 kPa pressure sensor vented gauge pressure sensor 4-SIP MPX53GP ventilator pressure sensor MPX53GP vs MPX53DP MPX53GP drop-in replacement MPX53GP buy price stock uncompensated piezoresistive pressure sensor MPX53GP pinout 4-SIP low voltage 50 kPa sensor 3V supply

Связанные компоненты & термины

NXP Semiconductors Freescale Semiconductor Motorola MPX53GP MPX53DP MPXV53GC MPX53 MPX2010GP MPX2100AP piezoresistive pressure sensor Wheatstone bridge vented gauge uncompensated sensor pressure sensor IC MEMS 4-SIP package IEC 60601 RoHS REACH barometric pressure sensor altimeter CPAP ventilator
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ