ADE9153AACPZ-RL - Single-Phase Auto-Calibrating Meter IC | ADI
MPN: ADE9153AACPZ-RL ✓ NakahandaADE9153AACPZ-RL Ulas
An energy-metering IC is a specialized data-acquisition and power-management component. In the measurement hierarchy, it sits between analog signal conditioning, analog-to-digital conversion, and the embedded processing that calculates real energy, RMS quantities, and related billing information. Unlike a general-purpose ADC, the ADE9153A family is configured for voltage and current channels used in electricity meters. Its autocalibration function can calibrate both channels when a shunt resistor is used as the current sensor, without requiring an accurate external source or reference meter.
The verified sources identify the ADE9153AACPZ-RL as a single-phase meter IC with auto-calibration. Analog Devices also offers the EV-ADE9153ASHIELDZ evaluation shield for prototyping energy-measurement systems. The shield includes a shunt resistor for line-current measurement and supports Arduino Uno, Arduino Zero, and ESP8266 platforms, with an Arduino library and application examples available from the product page. These resources make the device suitable both for production meter designs and early firmware evaluation.
The 32-LFCSP package requires careful PCB layout, exposed-pad thermal management, and short analog routing around the voltage and current inputs. Digital communication and supply decoupling paths should be separated from sensitive analog nodes to preserve measurement quality. Because the supplied data does not state accuracy, channel resolution, clock frequency, output interface, or absolute maximum ratings, those parameters must be confirmed in the manufacturer datasheet before schematic sign-off.
Typical uses include single-phase residential electricity meters, compact energy monitors, smart plugs, industrial sub-metering units, and Arduino-based measurement prototypes. The -40°C to 85°C range supports deployments across commercial and industrial ambient conditions, while the 2.97 V to 3.63 V supply range fits a regulated 3.3 V system. The -RL suffix and verified packaging references identify the tape-and-reel ordering option for automated assembly.
For a new design, use the Analog Devices evaluation shield and library to validate signal scaling, calibration behavior, and host-interface requirements before committing to a production board. In production, reproduce the manufacturer's recommended grounding, input filtering, exposed-pad, and decoupling layouts exactly where possible. This page combines verified distributor data, official evaluation resources, and engineering-focused selection guidance without inventing unprovided performance values.
Mga alternatibo na pwedeng ilagay na ADE9153AACPZ-RL — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.
Variante sa Seri na ito
Katulad na modelo sa serye na katugma sa pagpasok ADE9153AACPZ-RL (parehas na form factor at footprint) — pagkakaiba sa Operating Temperature Range, Package, Product Type.
Wala ng magagamit na drop-in alternatibo para sa produkto na ito.
Hilingin ang AlternatiboADE9153AACPZ-RL Mga Pinakamataas na Rating at Electrical Characteristics
| Product Type | Single-phase energy-metering IC |
| Measurement Phase | 1 phase |
| Calibration Feature | Automatic current-channel and voltage-channel calibration |
| Supply Voltage Range | 2.97 V to 3.63 V |
| Hanay ng Temperature na Operasyon | -40°C to 85°C |
| Packhaging | 32-LFCSP, 5 mm x 5 mm |
| Alternative Package Description | 32-WFQFN exposed pad, CSP |
| Uri ng Pagpapasok | Surface mount |
| Packaging Type | Tape and reel |
| Voltage Input | Mains line-voltage measurement channel |
| Current Input | Shunt-resistor line-current measurement channel |
| Autocalibration Requirement | No accurate source or accurate reference meter required when using a shunt resistor |
| Evaluation Accessory | EV-ADE9153ASHIELDZ |
| Evaluation Platform Support | Arduino Uno, Arduino Zero, ESP8266 |
| Software Support | Arduino library and application examples |
| Component Classification | Power Management IC |
| Functional Category | Data-acquisition ADC/DAC specialized meter IC |
Gabay sa Pin Configuration ng ADE9153AACPZ-RL 32-wfqfn exposed pad, csp
Pin configuration para sa ADE9153AACPZ-RL (32-wfqfn exposed pad, csp package). Ang analog component na ito ay may input, output, at power supply pins. Sumangguni sa datasheet ng manufacturer para sa offset null, compensation, at enable pin configurations. Perpekto para sa signal conditioning at amplifier circuits.
Wala ng detalyadong pinout data na magagamit para sa ADE9153AACPZ-RL.
Sumangguni sa datasheet para sa buong pin configuration.
Tipikal na mga Gamit
ADE9153AACPZ-RL ay nararapat para sa 6 aplikasyons: Single-Phase Residential Electricity Meter, Smart Plug Energy Monitor, Industrial Sub-Metering Unit, Arduino-Based Energy Monitor, Compact Energy Monitoring Controller, Portable Energy Analyzer Prototype.
Single-Phase Residential Electricity Meter
The ADE9153AACPZ-RL fits a dedicated single-phase revenue meter because it combines voltage-channel and shunt-current measurement with automatic calibration. Its verified 2.97 V to 3.63 V supply range supports a regulated 3.3 V meter electronics section, while automatic gain calibration can reduce dependence on an accurate production source or reference meter. Place the sensitive current input close to its shunt and analog-ground network, isolate the mains sensing section, and validate calibration behavior over temperature and load. The 32-LFCSP package saves board area but requires exposed-pad land-pattern compliance and careful thermal review.
Inirekomenda
Smart Plug Energy Monitor
The ADE9153AACPZ-RL can support compact smart-plug energy monitoring when a shunt resistor measures line current and a protected divider senses line voltage. Its automatic calibration is useful in high-volume assemblies where reducing manual gain adjustment improves consistency. The verified 3.3 V-compatible supply range simplifies integration with embedded control logic, and the 5 mm by 5 mm LFCSP helps limit PCB area. However, the IC does not replace the fuse, surge protection, galvanic-isolation strategy, safety-approved enclosure, or regulatory validation required for a mains-connected product.
Inirekomenda
Industrial Sub-Metering Unit
For industrial single-phase sub-metering, the ADE9153AACPZ-RL provides a specialized metering front end with autocalibrated voltage and current channels. The verified -40°C to 85°C operating range covers many commercial and industrial environments, while automatic calibration can reduce per-unit alignment effort. The design should provide isolated sensing, surge protection, local regulation, and a communication interface appropriate to the installation. Engineers should confirm metering accuracy, channel bandwidth, clock requirements, and output protocol in the manufacturer documentation before selecting the part for billing-grade use.
Inirekomenda
Arduino-Based Energy Monitor
The ADE9153AACPZ-RL is well suited to an Arduino-based energy monitor because Analog Devices offers the EV-ADE9153ASHIELDZ with an onboard current shunt. The verified manufacturer information states compatibility with Arduino Uno, Arduino Zero, and ESP8266 platforms and provides an Arduino library plus application examples. This combination shortens firmware bring-up and lets developers evaluate scaling, readings, and calibration before designing a custom board. The shield should be treated as an evaluation platform, not as a substitute for production safety, isolation, and enclosure engineering.
Inirekomenda
Compact Energy Monitoring Controller
The ADE9153AACPZ-RL can serve as the measurement engine in a compact energy-monitoring controller that must acquire both voltage and line-current information. Its single-phase specialization avoids carrying unnecessary multiphase circuitry, and its 32-LFCSP package supports denser assemblies than larger leaded or high-pin-count meter packages. The verified supply range and broad operating-temperature interval support industrial control boards. Layout must keep switching regulators and digital interfaces away from the analog inputs, while firmware must confirm that autocalibration events are interpreted correctly by the host or display system.
Inirekomenda
Portable Energy Analyzer Prototype
The ADE9153AACPZ-RL is useful in a portable single-phase energy-analyzer prototype built around the Arduino ecosystem. The verified availability of a library and application examples for Arduino Uno, Arduino Zero, and ESP8266 accelerates data acquisition, while autocalibration helps simplify initial characterization of the voltage and shunt-current channels. Designers should use an appropriately protected, isolated sensing arrangement rather than exposing evaluation hardware to unrestricted mains energy. The 32-LFCSP footprint also supports compact prototypes, although layout should begin from Analog Devices' package and reference guidance.
Inirekomenda
Buod ng mga Inirekomendang Produkto
Impormasyon ng Talumpati sa Engineering for ADE9153AACPZ-RL — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.
Paunawang Hanapin
Ikabit sa Mga Alternatibo
| Parametro | Ito ang Producto |
|---|---|
| Brand | Analog Devices |
| Package | 32-LFCSP, 5 mm x 5 mm |
| Product Type | Single-phase energy-metering IC |
| Supply Voltage | 2.97 V to 3.63 V |
| Operating Temperature | -40°C to 85°C |
| Autocalibration | Voltage-channel and current-channel automatic calibration |
| Current-Sensing Method | Shunt resistor |
| Evaluation Platform | EV-ADE9153ASHIELDZ for Arduino Uno, Arduino Zero, and ESP8266 |
Pangunahing mga Pagkakaiba
- Integrated metrology purpose (kumpara saGeneral-purpose ADC)
- Production calibration simplification (kumpara saManually calibrated meter implementation)
- Compact dedicated package (kumpara saLarger discrete energy-measurement front end)
Talaan ng Disenyo
Keep the voltage and current inputs short, guarded, and away from switching nodes and high-current return paths. Follow the manufacturer's recommended analog grounding and exposed-pad land pattern; the supplied sources confirm a 32-LFCSP, 5 mm by 5 mm package but do not provide the full land pattern. Treat the mains divider and shunt network as high-energy, high-voltage nodes, and keep copper under the IC limited as required by the complete safety design.
Power the ADE9153A from a regulated source within the verified 2.97 V to 3.63 V range. Place local decoupling at the supply pins using the manufacturer's recommended capacitance and ESR characteristics, which are not provided in the supplied data and must be taken from the datasheet. Keep the analog supply return continuous through the exposed-pad region and isolate switching-node currents from the measurement reference path.
Do not assume that autocalibration eliminates the need for a sound shunt and voltage-divider design. Verify polarity, scaling, gain constants, calibration timing, and meter constants in firmware with known test conditions. The supplied search results confirm automatic calibration for voltage and current channels, but they do not provide accuracy limits, resolution, or calibration equations; obtain those values from the manufacturer datasheet before production use.
Impormasyon ng Pagsunod sa Kautusan
The supplied sources do not provide explicit compliance declarations. No compliance status has been inferred from the package, manufacturer, or distributor listings.