ADE9153AACPZ-RL - Single-Phase Auto-Calibrating Meter IC | ADI
料号: ADE9153AACPZ-RL ✓ 量产中| 数量 | 单价 | 小计 |
|---|---|---|
| 1 | $5.8205 | $5.82 |
| 10 | $9.1323 | $91.32 |
| 100 | $9.1323 | $913.23 |
| 500 | $9.1323 | $4,566.15 |
| 1,000 | $9.1323 | $9,132.30 |
ADE9153AACPZ-RL 概述
An energy-metering IC is a specialized data-acquisition and power-management component. In the measurement hierarchy, it sits between analog signal conditioning, analog-to-digital conversion, and the embedded processing that calculates real energy, RMS quantities, and related billing information. Unlike a general-purpose ADC, the ADE9153A family is configured for voltage and current channels used in electricity meters. Its autocalibration function can calibrate both channels when a shunt resistor is used as the current sensor, without requiring an accurate external source or reference meter.
The verified sources identify the ADE9153AACPZ-RL as a single-phase meter IC with auto-calibration. Analog Devices also offers the EV-ADE9153ASHIELDZ evaluation shield for prototyping energy-measurement systems. The shield includes a shunt resistor for line-current measurement and supports Arduino Uno, Arduino Zero, and ESP8266 platforms, with an Arduino library and application examples available from the product page. These resources make the device suitable both for production meter designs and early firmware evaluation.
The 32-LFCSP package requires careful PCB layout, exposed-pad thermal management, and short analog routing around the voltage and current inputs. Digital communication and supply decoupling paths should be separated from sensitive analog nodes to preserve measurement quality. Because the supplied data does not state accuracy, channel resolution, clock frequency, output interface, or absolute maximum ratings, those parameters must be confirmed in the manufacturer datasheet before schematic sign-off.
Typical uses include single-phase residential electricity meters, compact energy monitors, smart plugs, industrial sub-metering units, and Arduino-based measurement prototypes. The -40°C to 85°C range supports deployments across commercial and industrial ambient conditions, while the 2.97 V to 3.63 V supply range fits a regulated 3.3 V system. The -RL suffix and verified packaging references identify the tape-and-reel ordering option for automated assembly.
For a new design, use the Analog Devices evaluation shield and library to validate signal scaling, calibration behavior, and host-interface requirements before committing to a production board. In production, reproduce the manufacturer's recommended grounding, input filtering, exposed-pad, and decoupling layouts exactly where possible. This page combines verified distributor data, official evaluation resources, and engineering-focused selection guidance without inventing unprovided performance values.
直接替换替代料: ADE9153AACPZ-RL ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADE9153AACPZ-RL (相同外形与封装尺寸) ——差异在于 Operating Temperature Range, Package, Product Type.
快速对比工具——选择替代料号进行并排对比:
该产品暂无直接替换替代料。
请求替代料ADE9153AACPZ-RL 最大额定值与电气特性
| Product Type | Single-phase energy-metering IC |
| Measurement Phase | 1 phase |
| Calibration Feature | Automatic current-channel and voltage-channel calibration |
| Supply Voltage Range | 2.97 V to 3.63 V |
| 工作温度范围 | -40°C to 85°C |
| 封装 | 32-LFCSP, 5 mm x 5 mm |
| Alternative Package Description | 32-WFQFN exposed pad, CSP |
| 安装类型 | Surface mount |
| Packaging Type | Tape and reel |
| Voltage Input | Mains line-voltage measurement channel |
| Current Input | Shunt-resistor line-current measurement channel |
| Autocalibration Requirement | No accurate source or accurate reference meter required when using a shunt resistor |
| Evaluation Accessory | EV-ADE9153ASHIELDZ |
| Evaluation Platform Support | Arduino Uno, Arduino Zero, ESP8266 |
| Software Support | Arduino library and application examples |
| Component Classification | Power Management IC |
| Functional Category | Data-acquisition ADC/DAC specialized meter IC |
ADE9153AACPZ-RL 32-wfqfn exposed pad, csp 引脚配置指南
ADE9153AACPZ-RL(32-wfqfn exposed pad, csp 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: ADE9153AACPZ-RL.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADE9153AACPZ-RL 适用于 6 应用s: Single-Phase Residential Electricity Meter, Smart Plug Energy Monitor, Industrial Sub-Metering Unit, Arduino-Based Energy Monitor, Compact Energy Monitoring Controller, Portable Energy Analyzer Prototype.
Single-Phase Residential Electricity Meter
The ADE9153AACPZ-RL fits a dedicated single-phase revenue meter because it combines voltage-channel and shunt-current measurement with automatic calibration. Its verified 2.97 V to 3.63 V supply range supports a regulated 3.3 V meter electronics section, while automatic gain calibration can reduce dependence on an accurate production source or reference meter. Place the sensitive current input close to its shunt and analog-ground network, isolate the mains sensing section, and validate calibration behavior over temperature and load. The 32-LFCSP package saves board area but requires exposed-pad land-pattern compliance and careful thermal review.
推荐
Smart Plug Energy Monitor
The ADE9153AACPZ-RL can support compact smart-plug energy monitoring when a shunt resistor measures line current and a protected divider senses line voltage. Its automatic calibration is useful in high-volume assemblies where reducing manual gain adjustment improves consistency. The verified 3.3 V-compatible supply range simplifies integration with embedded control logic, and the 5 mm by 5 mm LFCSP helps limit PCB area. However, the IC does not replace the fuse, surge protection, galvanic-isolation strategy, safety-approved enclosure, or regulatory validation required for a mains-connected product.
推荐
Industrial Sub-Metering Unit
For industrial single-phase sub-metering, the ADE9153AACPZ-RL provides a specialized metering front end with autocalibrated voltage and current channels. The verified -40°C to 85°C operating range covers many commercial and industrial environments, while automatic calibration can reduce per-unit alignment effort. The design should provide isolated sensing, surge protection, local regulation, and a communication interface appropriate to the installation. Engineers should confirm metering accuracy, channel bandwidth, clock requirements, and output protocol in the manufacturer documentation before selecting the part for billing-grade use.
推荐
Arduino-Based Energy Monitor
The ADE9153AACPZ-RL is well suited to an Arduino-based energy monitor because Analog Devices offers the EV-ADE9153ASHIELDZ with an onboard current shunt. The verified manufacturer information states compatibility with Arduino Uno, Arduino Zero, and ESP8266 platforms and provides an Arduino library plus application examples. This combination shortens firmware bring-up and lets developers evaluate scaling, readings, and calibration before designing a custom board. The shield should be treated as an evaluation platform, not as a substitute for production safety, isolation, and enclosure engineering.
推荐
Compact Energy Monitoring Controller
The ADE9153AACPZ-RL can serve as the measurement engine in a compact energy-monitoring controller that must acquire both voltage and line-current information. Its single-phase specialization avoids carrying unnecessary multiphase circuitry, and its 32-LFCSP package supports denser assemblies than larger leaded or high-pin-count meter packages. The verified supply range and broad operating-temperature interval support industrial control boards. Layout must keep switching regulators and digital interfaces away from the analog inputs, while firmware must confirm that autocalibration events are interpreted correctly by the host or display system.
推荐
Portable Energy Analyzer Prototype
The ADE9153AACPZ-RL is useful in a portable single-phase energy-analyzer prototype built around the Arduino ecosystem. The verified availability of a library and application examples for Arduino Uno, Arduino Zero, and ESP8266 accelerates data acquisition, while autocalibration helps simplify initial characterization of the voltage and shunt-current channels. Designers should use an appropriately protected, isolated sensing arrangement rather than exposing evaluation hardware to unrestricted mains energy. The 32-LFCSP footprint also supports compact prototypes, although layout should begin from Analog Devices' package and reference guidance.
推荐
推荐产品汇总
工程参考数据: ADE9153AACPZ-RL ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 |
|---|---|
| Brand | Analog Devices |
| Package | 32-LFCSP, 5 mm x 5 mm |
| Product Type | Single-phase energy-metering IC |
| Supply Voltage | 2.97 V to 3.63 V |
| Operating Temperature | -40°C to 85°C |
| Autocalibration | Voltage-channel and current-channel automatic calibration |
| Current-Sensing Method | Shunt resistor |
| Evaluation Platform | EV-ADE9153ASHIELDZ for Arduino Uno, Arduino Zero, and ESP8266 |
关键差异点
- Integrated metrology purpose (对比 General-purpose ADC)
- Production calibration simplification (对比 Manually calibrated meter implementation)
- Compact dedicated package (对比 Larger discrete energy-measurement front end)
设计说明
Keep the voltage and current inputs short, guarded, and away from switching nodes and high-current return paths. Follow the manufacturer's recommended analog grounding and exposed-pad land pattern; the supplied sources confirm a 32-LFCSP, 5 mm by 5 mm package but do not provide the full land pattern. Treat the mains divider and shunt network as high-energy, high-voltage nodes, and keep copper under the IC limited as required by the complete safety design.
Power the ADE9153A from a regulated source within the verified 2.97 V to 3.63 V range. Place local decoupling at the supply pins using the manufacturer's recommended capacitance and ESR characteristics, which are not provided in the supplied data and must be taken from the datasheet. Keep the analog supply return continuous through the exposed-pad region and isolate switching-node currents from the measurement reference path.
Do not assume that autocalibration eliminates the need for a sound shunt and voltage-divider design. Verify polarity, scaling, gain constants, calibration timing, and meter constants in firmware with known test conditions. The supplied search results confirm automatic calibration for voltage and current channels, but they do not provide accuracy limits, resolution, or calibration equations; obtain those values from the manufacturer datasheet before production use.
合规信息
The supplied sources do not provide explicit compliance declarations. No compliance status has been inferred from the package, manufacturer, or distributor listings.