Texas Instruments

INA101AM - Very High Accuracy Instrumentation Amplifier | Texas Instruments

MPN: INA101AM ✓ Nakahanda
±20 V Vdss TO-100-10 Package
MOQ: 1 |

INA101AM Ulas

Texas Instruments INA101AM is a very high accuracy instrumentation amplifier designed for low-level signal amplification and general-purpose data acquisition. It integrates three precision operational amplifiers and laser-trimmed metal-film resistors on a monolithic integrated circuit, providing differential input amplification with high input impedance, low offset voltage, low drift, and strong common-mode rejection. The verified distributor data identifies the device as a single-circuit instrumentation amplifier in a TO-100-10 package, and the available ordering information indicates operation from approximately 5 V to ±20 V depending on the supply configuration.

An instrumentation amplifier is a specialized differential amplifier optimized for measuring small differential signals that are superimposed on a much larger common-mode voltage. Its internal resistor network and matched amplifiers provide predictable gain, high input impedance, and accurate rejection of common-mode interference. This makes the INA101AM suitable for sensor interfaces, strain gauges, thermocouples, RTDs, bridge transducers, and general instrumentation systems where signal integrity and measurement stability are important.

The INA101AM datasheet highlights very low drift of 0.25 mV/°C maximum, low offset voltage of 25 mV maximum as identified in the verified distributor result, low nonlinearity of 0.002%, low noise of 13 nV/√Hz, and high common-mode rejection of 106 dB at 60 Hz. The available technical reference also describes a bandwidth of approximately 300 kHz and a high input impedance of 10 GΩ. These specifications support precision amplification of low-level sensor signals while preserving fast transient response.

The monolithic three-op-amp architecture and laser-trimmed resistors reduce component count and simplify instrumentation-amplifier implementation. The INA101AM is intended for applications requiring accurate differential measurement, including industrial process control, test and measurement equipment, medical instrumentation, load-cell interfaces, and remote sensor acquisition. The TO-100-10 mechanical package supports through-hole assembly and provides a practical option for legacy and industrial equipment designs.

A key design consideration is ensuring that input common-mode voltage and supply voltage remain within the datasheet limits. The gain-setting resistor and external input and feedback components should be selected with suitable tolerance and stability. Input filtering, guarding, grounding, and keeping sensor wiring away from high-current conductors can further improve repeatability and rejection of unwanted interference.

This product page consolidates the verified Texas Instruments, DigiKey, Mouser, and distributor information with practical application guidance, package details, and engineering-oriented selection information for engineers evaluating the INA101AM.

Mga alternatibo na pwedeng ilagay na INA101AM — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.

Variante sa Seri na ito

Katulad na modelo sa serye na katugma sa pagpasok INA101AM (parehas na form factor at footprint) — pagkakaiba sa Package, Mounting Type, Bandwidth, Input Impedance, Architecture.

Texas Instruments
Package: 14-CDIP (0.300", 7.62 mm)
Mounting Type: Through Hole
Bandwidth: 300 kHz
Ikabit sa INA101AM →
Texas Instruments
Package: 16-SOIC (DW / SOL-16)
Mounting Type: Surface Mount
Bandwidth: 25 kHz
Ikabit sa INA101AM →
Texas Instruments
Package: TO-100-10, through-hole
Ikabit sa INA101AM →

INA101AG

✅ Drop-In
Texas Instruments
📦 14-pin ceramic DIP
Instrumentation Amplifier · 1 · 25 uV · 0.25 uV/C · 0.002% · 13 nV/rtHz · 106 dB at 60 Hz · 10^10 ohm

Magkontak para sa presyo

Tingnan ang Datasheet →

INA101SM

✅ Drop-In
Texas Instruments
📦 SOIC-16
Very high accuracy instrumentation amplifier · 1 circuit · 3 precision operational amplifiers with laser-trimmed metal-film resistors · 25 uV max · 0.25 uV/°C max · 0.002% · 13 nV/√Hz · Specified at 60 Hz

Magkontak para sa presyo

Tingnan ang Datasheet →

INA101KU

✅ Drop-In
Texas Instruments
📦 SOIC-16
Instrumentation Amplifier · 1 · 3-amplifier (three op amp) architecture · 25 uV max · 0.25 uV/C max · 0.002% max · 13 nV/Hz · High CMR at 60 Hz

Magkontak para sa presyo

Tingnan ang Datasheet →

INA101P

✅ Drop-In ⚠️ Mga Talaan Hindi Naiwerikmo
📦 DIP-14
14-pin through-hole package differs mechanically from INA101AM TO-100-10

📋 Alternatibo na Reference (hindi sa katalogo)

INA101U

✅ Drop-In ⚠️ Mga Talaan Hindi Naiwerikmo
📦 SOIC-16
Surface-mount package differs from INA101AM TO-100-10; family-level electrical alternative

📋 Alternatibo na Reference (hindi sa katalogo)

INA101AM Mga Pinakamataas na Rating at Electrical Characteristics

Product Type Instrumentation Amplifier
Number of Channels 1 channel
Architecture Three precision operational amplifiers with laser-trimmed metal-film resistors
Input Type Differential
Maximum Supply Voltage ±20 V
Offset Voltage 25 mV maximum
Input Drift 0.25 mV/°C maximum
Nonlinearity 0.002%
Density ng Noise 13 nV/√Hz
Common-Mode Rejection Ratio 106 dB at 60 Hz
Input Impedance 10 GΩ
Bandwidth Approximately 300 kHz
Packhaging TO-100-10
Uri ng Pagpapasok Through-hole
Application Areas Strain gauges, thermocouples, RTDs, remote sensors, and general-purpose data acquisition

Gabay sa Pin Configuration ng INA101AM to-100-10

Pin configuration para sa INA101AM (to-100-10 package). Ang analog component na ito ay may input, output, at power supply pins. Sumangguni sa datasheet ng manufacturer para sa offset null, compensation, at enable pin configurations. Perpekto para sa signal conditioning at amplifier circuits.

Pinout diagram ng to-100-10 package para sa INA101AM

Wala ng detalyadong pinout data na magagamit para sa INA101AM.

Sumangguni sa datasheet para sa buong pin configuration.

Tipikal na mga Gamit

INA101AM ay nararapat para sa 6 aplikasyons: Strain-Gauge Bridge Measurement, Thermocouple Signal Conditioning, RTD Temperature Measurement, Precision Data Acquisition, Medical and Diagnostic Instrumentation, Load-Cell and Force Measurement.

🏭

Strain-Gauge Bridge Measurement

The INA101AM fits strain-gauge front ends because its differential instrumentation-amplifier architecture rejects common-mode bridge excitation while presenting a verified 10 GΩ input impedance. Its 106 dB CMRR at 60 Hz and 13 nV/√Hz noise density help preserve the small millivolt-level changes produced by a resistive bridge. Place the device close to the bridge, use symmetric routing, and confirm the applicable gain equation and supply limits in the manufacturer datasheet before finalizing the resistor values.

🏭

Thermocouple Signal Conditioning

INA101AM can condition the low-level differential output of a thermocouple while rejecting common-mode voltage present on industrial wiring. Its high input impedance limits sensor-loading error, and its verified 25 mV maximum offset and 0.25 mV/°C maximum drift are important considerations for temperature measurement. The circuit also needs cold-junction compensation, input protection, and carefully selected gain so that the usable thermocouple range is not saturated.

🏭

RTD Temperature Measurement

The INA101AM is suitable for resistive temperature detector bridges because differential measurement reduces sensitivity to supply and ground disturbances encountered along remote sensor wiring. Its verified 106 dB common-mode rejection at 60 Hz supports stable operation in electrically noisy environments, while the approximately 300 kHz bandwidth provides ample response for typical thermal systems. Use a precision excitation source and calculate lead-wire compensation and self-heating before applying the available gain.

📟

Precision Data Acquisition

INA101AM provides a compact single-channel instrumentation front end for laboratory and industrial data-acquisition systems. Differential input handling, 10 GΩ input impedance, and 106 dB common-mode rejection are useful when the source is small and a substantial offset voltage exists between the two input nodes. The approximately 300 kHz bandwidth supports general-purpose acquisition rather than ultra-high-speed sensing, making system-level aliasing and reference accuracy central design considerations.

💊

Medical and Diagnostic Instrumentation

The INA101AM can amplify small differential physiological or diagnostic sensor signals where high input impedance and common-mode rejection improve measurement integrity. Its verified 13 nV/√Hz noise density and 0.002% nonlinearity make it relevant to high-resolution front ends, although actual signal-chain suitability depends on the sensor bandwidth, electrode impedance, and safety isolation architecture. A medical design should separately validate patient protection, isolation, leakage current, and applicable regulatory requirements.

⚖️

Load-Cell and Force Measurement

INA101AM is appropriate for load-cell bridges that generate small differential voltages under excitation. The high common-mode rejection reduces errors from supply variation and cable-coupled interference, while high input impedance avoids significant bridge-loading error. For practical force systems, verify excitation voltage, full-scale output, amplifier gain, and input common-mode range against the load-cell manufacturer's specifications. Keep high-current motor wiring separate from the bridge leads to prevent unwanted thermal offsets.

What is the operating voltage of INA101AM?
The INA101AM supports bipolar supply operation and is identified in the verified technical references with a maximum supply voltage of ±20 V. The exact minimum, typical, and maximum supply limits should be confirmed against the Texas Instruments INA101 datasheet before final circuit design. The verified reference also describes operation from approximately 5 V to ±20 V across its supported supply configurations.
What are the key specifications of INA101AM that engineers should know?
The INA101AM is a one-channel, high-accuracy instrumentation amplifier with approximately 300 kHz bandwidth, 10 GΩ input impedance, 25 mV maximum offset voltage, 0.25 mV/°C maximum drift, 0.002% nonlinearity, and 13 nV/√Hz noise density. Its verified 106 dB common-mode rejection at 60 Hz makes it suitable for low-level differential sensor measurements.
What is INA101AM?
The INA101AM is a very high accuracy instrumentation amplifier from Texas Instruments. According to the manufacturer datasheet, it combines three precision operational amplifiers and laser-trimmed metal-film resistors on one monolithic integrated circuit. The INA101AM package is TO-100-10, and it is intended for instrumentation, sensor interfaces, and general-purpose data acquisition.
Where to download INA101AM datasheet PDF?
The official INA101AM datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/ina101.pdf. The verified manufacturer result identifies the document as the INA101 Very High Accuracy Instrumentation Amplifier datasheet. Use the manufacturer PDF for final pin assignments, supply limits, gain equations, and electrical test conditions.
Where can I find the INA101AM pinout?
The INA101AM pinout is found in the pin-configuration and package-drawing sections of the official Texas Instruments INA101 datasheet at https://www.ti.com/lit/ds/symlink/ina101.pdf. This page does not reproduce the pin assignment because a verified complete TO-100-10 pin table was not included in the supplied web data.
Is INA101AM suitable for strain-gauge measurements?
Yes, INA101AM is explicitly listed for strain-gauge applications in the verified Texas Instruments datasheet information. Its 106 dB common-mode rejection at 60 Hz, 10 GΩ input impedance, and 13 nV/√Hz noise density are valuable when the transducer output is small and the input common-mode voltage is substantial. Final gain and bridge-excitation values must be calculated from the complete datasheet.
Is INA101AM suitable for thermocouple and RTD interfaces?
Yes, the verified Texas Instruments material identifies thermocouples, RTDs, and remote sensors as INA101 applications. The instrumentation-amplifier architecture provides differential input measurement and high input impedance, while the 0.25 mV/°C maximum drift specification supports temperature-related measurement stability. Cold-junction compensation, sensor polarity, and input protection are external design requirements.
How does INA101AM compare with INA101AG?
INA101AM and INA101AG are related Texas Instruments instrumentation-amplifier orderings, but the verified comparison data identifies different mechanical packages: INA101AM is TO-100-10, while INA101AG is a 14-pin ceramic DIP. Consequently, INA101AG is not a true drop-in replacement for INA101AM without a PCB or package-level redesign, despite sharing the INA101 family.
How does INA101AM compare with INA101SM?
INA101SM belongs to the same Texas Instruments INA101 family and offers a different packaging option, but the supplied comparison information identifies INA101SM as a distinct package from the TO-100-10 INA101AM. It should therefore be treated as a functional family alternative, not a pin-to-pin drop-in replacement, unless a verified package drawing confirms the identical footprint.
When should I choose INA101AM over another instrumentation amplifier?
Choose INA101AM when the design needs a discrete, high-accuracy instrumentation amplifier in a TO-100-10 through-hole package and the verified 106 dB common-mode rejection, 10 GΩ input impedance, and approximately 300 kHz bandwidth are sufficient. Choose a surface-mount or newer low-noise alternative when board area, power consumption, or application-specific accuracy is more important than legacy through-hole compatibility.
What can replace INA101AM?
The verified cross-reference results identify functional equivalents from Analog Devices, Intersil, and National Semiconductor, but they do not provide verified TO-100-10 pin compatibility or complete parameter tables for those parts. The INA101AG, INA101SM, and INA101KU family alternatives use different packages. Therefore, no confirmed direct drop-in replacement is established by the supplied evidence.
Is INA101AM the same as INA101AG?
No, INA101AM and INA101AG are not mechanically interchangeable in the supplied comparison data. INA101AM is a 10-pin TO-100-10 part, whereas INA101AG is a 14-pin ceramic DIP. Their shared INA101 family identity does not make them pin-to-pin compatible, so INA101AG requires a different footprint and PCB layout.
Where to buy INA101AM online and what is its price?
The INA101AM is listed by DigiKey and Mouser with direct links to the Texas Instruments part. The supplied distributor snippets confirm availability or purchasing information but do not provide numeric price values, so the verified price is [DATA_NEEDED: current distributor price as of 2026-10-28]. Request a quotation from XAIPART for a current order quote.
What is the lead time for INA101AM?
The verified DigiKey result states that the INA101AM can be purchased and ships today, but no numeric factory or distributor lead time is included in the supplied data. Current lead time is therefore [DATA_NEEDED: numeric lead time as of 2026-10-28]. Confirm the quantity-dependent shipment schedule before committing an engineering schedule.
Is INA101AM in stock?
DigiKey's verified listing says “Buy now, ships today,” which indicates distributor availability for the INA101AM. The supplied data does not quantify the available stock quantity, so inventory level is [DATA_NEEDED: current stock quantity as of 2026-10-28]. Availability can change by quantity and purchasing account.
What is the best Analog Devices equivalent for INA101AM?
The supplied cross-reference results list Analog Devices among manufacturers offering functional equivalents, but they do not identify a candidate with a verified TO-100-10 footprint and pin-for-pin compatibility. No Analog Devices part can therefore be responsibly presented as a direct drop-in replacement from the supplied evidence. Compare the complete candidate datasheet for bandwidth, offset, drift, CMRR, noise, supply range, and package.

Impormasyon ng Talumpati sa Engineering for INA101AM — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.

Paunawang Hanapin

Choose INA101AM when the design needs a high-accuracy, single-channel instrumentation amplifier in a TO-100-10 through-hole package. Its verified 106 dB CMRR at 60 Hz, 10 GΩ input impedance, 13 nV/√Hz noise density, and approximately 300 kHz bandwidth are useful for strain gauges, RTDs, thermocouples, and general data acquisition. INA101AG may be appropriate when a 14-pin ceramic DIP is acceptable, while INA101SM, INA101KU, and INA101U are relevant when a surface-mount package is preferred. However, the verified information does not establish those orderings as pin-to-pin replacements for INA101AM. For a new compact design, compare a modern low-noise instrumentation amplifier for power consumption, package size, input common-mode range, and total cost. For an existing INA101AM PCB, preserve the TO-100-10 footprint and verify every electrical and mechanical detail before substituting a candidate.

Ikabit sa Mga Alternatibo

Parametro Ito ang Producto INA101AG INA101SM INA101KU INA101P INA101U
Package TO-100-10 14-pin ceramic DIP SOIC-16 SOIC-16 DIP-14 SOIC-16
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Product Type Instrumentation Amplifier Instrumentation Amplifier Instrumentation Amplifier Instrumentation Amplifier Instrumentation Amplifier Instrumentation Amplifier
Number of Channels 1 channel 1 channel 1 channel 1 channel 1 channel 1 channel

Pangunahing mga Pagkakaiba

  • Verified high common-mode rejection (kumpara saINA101AG)
  • High input impedance for low-level sensing (kumpara saINA101SM)
  • Low-noise instrumentation amplification (kumpara saINA101KU)

Talaan ng Disenyo

Route the two differential inputs as a closely matched pair and keep them away from switching nodes, relay contacts, and high-current return paths. A grounded guard or shield can reduce capacitive pickup on long sensor cables. Check the complete Texas Instruments datasheet for the recommended input and gain-resistor layout before manufacturing, because the internal resistor network is sensitive to parasitic resistance and leakage.

Do not assume that a family member with the same INA101 designation is mechanically interchangeable. The verified INA101AM ordering uses TO-100-10, while INA101AG, INA101SM, INA101KU, INA101P, and INA101U use other package options identified in the comparison results. Confirm the physical dimensions, lead pitch, exposed connections, and complete electrical tables in each manufacturer datasheet before treating any candidate as a replacement.

Use clean, independently decoupled supply rails and follow the manufacturer's recommended bypass-capacitor arrangement. The INA101AM operates with bipolar supply voltages up to ±20 V according to the verified reference, but the usable input common-mode range must remain valid at the selected gain and supply voltage. Decoupling close to the device helps prevent supply ripple from converting into measurement error.

For sensor inputs below the millivolt range, input bias current, resistor leakage, thermoelectric effects, and connector contact resistance can be more important than the nominal 13 nV/√Hz noise density. Use low-leakage gain-setting resistors, stable low-noise references where applicable, and clean connector contacts. Evaluate drift and offset at the actual temperature range rather than relying only on the 25 mV and 0.25 mV/°C maximum ratings.

Impormasyon ng Pagsunod sa Kautusan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Walang Lead
Unknown
Walang Halogen
Unknown
Mga Conflict Mineral
Unknown

The supplied verified web data contains technical specifications, manufacturer links, and distributor listings but does not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. These fields remain unknown rather than inferred.

Data napatotohanan sa: 2026-10-28 — impormasyon na pinatunayan at pinapatakbo ng pangkat ng engineering ng XAIPART's component engineering team

Kaugnay na Hanapin

INA101AM INA101AM datasheet PDF Texas Instruments INA101AM INA101AM TO-100-10 instrumentation amplifier INA101AM 106 dB CMRR INA101AM 300 kHz bandwidth INA101AM strain gauge amplifier INA101AM thermocouple RTD interface INA101AM vs INA101AG INA101AM vs INA101SM INA101AM drop-in replacement INA101AM buy online INA101AM price and stock Where to find INA101AM pinout What can replace INA101AM

Mga kaugnay na Mga Komponente at mga Tuntunin

Texas Instruments INA101AM INA101 INA101AG INA101SM INA101KU INA101P INA101U instrumentation amplifier differential amplifier signal-conditioning IC amplifier IC integrated circuit semiconductor TO-100-10 through-hole package laser-trimmed metal-film resistor common-mode rejection ratio CMRR input impedance offset voltage input drift noise density strain gauge thermocouple RTD data acquisition DigiKey Mouser
Mabilis na Tanggap na RFQ
Ihanda ang buong detalye — ang aming pangkalakal na koponan ay tutugon sa loob ng 24 oras
Numero ng Parte Mga Tagagawa Pakete QTY Target na Halaga Pinalawak
✓
Quote na inilabas!

Ating tumugon sa iyong email sa loob ng 24 oras

1
RFQ Naisumite
2
Received na ang Kwaliksik
3
Nai-order
4
Pagbabayad
5
Inihanda
6
Naihanda
Tingnan ang Detalye ng RFQ