Texas Instruments

INA101AG - High Accuracy Instrumentation Amplifier | TI

MPN: INA101AG ✓ Active
In Stock Ships in 1-3 business days
25 uV Vdss 14-CDIP (0.300", 7.62 mm) Package
From $50.01 USD / Unit
MOQ: 1 |
Price updated: 2026-09-12
Volume Pricing
Qty Unit Price Extended
1 $50.01 $50.01
10 $50.01 $500.10
100 $50.01 $5,001.00
500 $50.01 $25,005.00
1,000 $50.01 $50,010.00
ℹ️ All prices are in USD

Drop-in alternatives for INA101AG — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

INA101HP

✅ Drop-In ⚠️ 参数待验证
Texas Instruments
📦 14-DIP
Instrumentation Amplifier · 1 · 25 uV · 0.25 uV/C · 0.002% · 13 nV/Hz · 10^10 ohm · 0.04 V/us

✓ In Stock

$8.4 / Unit

View Datasheet →

INA101KP

✅ Drop-In ⚠️ 参数待验证
📦 14-DIP
plastic DIP, commercial-grade spec limits (50 uV offset class vs 25 uV AG grade); pin-to-pin compatible

📋 Reference alternative (not in catalog)

INA101SG

✅ Drop-In ⚠️ 参数待验证
Texas Instruments
📦 14-CDIP
High Accuracy Instrumentation Amplifier · Three-op-amp with laser-trimmed metal-film resistors · 25 uV · 0.25 uV/C · 0.002% · 13 nV/Hz · 10^10 ohm · High CMR at 60 Hz (value per datasheet)

✓ In Stock

$9.45 / Unit

View Datasheet →

INA101AG Maximum Ratings & Electrical Characteristics

Amplifier Type Instrumentation Amplifier
Number of Channels 1
Input Offset Voltage (max) 25 uV
Offset Drift (max) 0.25 uV/C
Nonlinearity (max) 0.002%
Input Noise Density 13 nV/rtHz
Common-Mode Rejection 106 dB at 60 Hz
Input Impedance 10^10 ohm
Bandwidth 300 kHz
Slew Rate 0.04 V/us
Supply Voltage Range +/-5 V to +/-20 V
Package 14-CDIP (0.300", 7.62 mm)
Mounting Type Through Hole
Architecture Three-op-amp, laser-trimmed metal-film resistors
Applications Strain gages, thermocouples, RTDs, remote transducers

INA101AG 14-cdip (0.300", 7.62 mm) Pin Configuration Guide

Complete pinout information for INA101AG (14-cdip (0.300", 7.62 mm) package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.

14-cdip (0.300", 7.62 mm) package pinout diagram for INA101AG

No detailed pinout data available for INA101AG.

Refer to the datasheet for full pin configuration.

Safe Operating Area (SOA) & Thermal Characteristics

Safe Operating Area Chart Default safe operating area chart for INA101AG Drain-to-Source Voltage (Vds) Drain Current (Id)

No official SOA curve available for this component. Always operate within absolute maximum ratings specified in the datasheet. Ensure adequate cooling and derate as needed.

Typical Applications

INA101AG is suitable for 6 applications: Strain Gage Bridge Amplifier, Thermocouple Measurement Front End, RTD Temperature Signal Conditioning, Remote Transducer / Industrial Data Acquisition, Medical / Biomedical Signal Amplification, Legacy Military / Aerospace Sustaining Designs.

🔧

Strain Gage Bridge Amplifier

The INA101AG is explicitly listed by TI for strain gage amplification. A Wheatstone bridge outputs microvolt-per-volt sensitivity, and the INA101AG's 25 uV max offset and 0.25 uV/C drift preserve bridge resolution without periodic recalibration. Its 10^10 ohm input impedance prevents loading of high-output-impedance bridges, while 106 dB CMR at 60 Hz rejects excitation common-mode and mains pickup on cable runs. Gain is set with one external resistor RG; with 300 kHz bandwidth, dynamic strain up to tens of kHz is covered. Placed directly at the bridge, the in-amp converts the differential bridge signal to a ground-referenced output for an ADC or filter stage.

🌡️

Thermocouple Measurement Front End

Thermocouples generate roughly 40 uV/C, so amplifier offset and drift dominate measurement error. The INA101AG's 25 uV max offset corresponds to under 1 C equivalent error, and 0.25 uV/C drift adds negligible error over ambient swings. The 13 nV/rtHz noise keeps resolution loss minimal over typical thermocouple bandwidths of a few Hz to a few hundred Hz. High 10^10 ohm input impedance supports differential connection with protection resistors and RC filtering without introducing gain error. Set gain to approximately 100 to 500 to map a K-type or J-type span onto a 0-5V ADC range, and provide cold-junction compensation with a precision sensor at the connector block.

🌡️

RTD Temperature Signal Conditioning

RTDs are typically excited with a small constant current (1 mA or less) and read differentially; the resultant millivolt-level signals ride on large common-mode excitation voltage. The INA101AG's 106 dB CMR at 60 Hz suppresses this common-mode component and line interference, while 0.002% max nonlinearity preserves the ratiometric accuracy of a 3-wire or 4-wire RTD hookup. The 10^10 ohm input impedance eliminates lead-resistance loading in high-impedance 3-wire circuits. With gain of about 100 and a 100-ohm platinum RTD, the in-amp yields a usable volts/C signal suitable for a 12-bit ADC or analog controller without additional amplification stages.

🏭

Remote Transducer / Industrial Data Acquisition

For remote sensors connected over long cable runs, the dominant error source is common-mode interference picked up between the cable and the acquisition chassis. The INA101AG's 106 dB CMR at 60 Hz and 10^10 ohm differential input impedance make it well suited to 4-20 mA-sourced shunt measurements and microvolt-level remote signals where grounding differences exist between source and receiver. Its dual +/-5V to +/-20V supply tolerance accommodates legacy +/-15V industrial rails directly. The ceramic CDIP package withstands elevated ambient temperatures typical of control cabinets. Place input RC filters ahead of the in-amp and keep RG connections short to maintain the laser-trimmed gain accuracy.

💊

Medical / Biomedical Signal Amplification

Low-level biomedical signals such as ECG and EEG front ends historically used precision in-amps of this class; the INA101AG's 13 nV/rtHz noise, 10^10 ohm input impedance, and 106 dB CMR meet the baseline needs of electrode differential measurement, rejecting 50/60 Hz mains pickup at the electrodes. Its 300 kHz bandwidth comfortably covers the sub-kHz content of physiological signals. Note that the INA101 predates modern medical safety qualification, so designs must add patient isolation (isolation amplifier or digital isolator), input protection, and bias-current return paths, and must verify biocompatibility and IEC 60601 compliance at the system level rather than relying on the amplifier alone.

✈️

Legacy Military / Aerospace Sustaining Designs

The ceramic 14-CDIP package of the INA101AG exists precisely for high-reliability and military platforms that specified ceramic packaging and through-hole assembly for vibration, temperature, and long-term reliability. Sustaining designs - avionics sensor conditioning, test-set instrumentation, and spares manufacturing for fielded systems - continue to require the AG-grade part. The 25 uV offset, 0.25 uV/C drift, and +/-20V supply tolerance support legacy +/-15V mil analog rails without redesign. When sourcing, verify date codes and distributor authenticity carefully because legacy CDIP precision parts are common counterfeit targets; buy from authorized or franchise distributors whenever stock permits.

Recommended Products Summary

REF102 Precision 10V bridge excitation reference Used in: Strain Gage Bridge Amplifier, RTD Temperature Signal Conditioning, Legacy Military / Aerospace Sustaining Designs OPA2277 Precision op-amp for filter/gain stage after in-amp Used in: Strain Gage Bridge Amplifier, RTD Temperature Signal Conditioning, Medical / Biomedical Signal Amplification LM35 Cold-junction compensation sensor Used in: Thermocouple Measurement Front End CS5532-ASZ Cirrus Logic Inc. Used in: Thermocouple Measurement Front End ISO124 Precision isolation amplifier for isolated field signals Used in: Remote Transducer / Industrial Data Acquisition, Medical / Biomedical Signal Amplification INA117P Texas Instruments Used in: Remote Transducer / Industrial Data Acquisition MPY100AG Texas Instruments Used in: Legacy Military / Aerospace Sustaining Designs
What is the input offset voltage of the INA101AG?
The INA101AG has a maximum input offset voltage of 25 uV, with maximum drift of 0.25 uV/C. According to the TI INA101 datasheet, these figures are achieved by laser-trimmed metal-film resistors on the monolithic die, which is what enables precision bridge measurements without calibration.
What package does INA101AG come in?
The INA101AG is supplied in a 14-pin ceramic DIP package (CDIP-14, 0.300 inch / 7.62 mm wide), a through-hole package. The INA101 family was also offered in plastic DIP, SOL-16, and TO-100 metal can packages, per the TI datasheet, so ceramic CDIP is specific to the AG-grade military/industrial version.
What is the common-mode rejection of the INA101AG?
The INA101AG provides 106 dB of common-mode rejection at 60 Hz according to the TI datasheet. This very high CMR allows microvolt-level differential signals from strain gages or thermocouples to be extracted from line-frequency interference on long cable runs, which is a primary reason the part is specified for industrial data acquisition.
What is the price of INA101AG?
INA101AG is listed at approximately $50.01 per unit (qty 1) as of 2026-09-13, with over 17,400 pieces in stock at major independent distributors such as Heisener. Because this is a legacy precision part, pricing varies significantly between authorized and independent distributors; request quotes for volume pricing above 100 pieces.
Where to buy INA101AG online?
INA101AG can be purchased from DigiKey and independent distributors such as Heisener; Octopart lists 4 distributors carrying the part as of 2026-09-13. Heisener reports 17,400 pieces in stock with immediate shipment. For the ceramic CDIP package, verify date codes and authenticity when buying from brokers, since legacy precision parts are frequently counterfeited.
What is the bandwidth of INA101AG?
The INA101AG has a 300 kHz bandwidth and a 0.04 V/us slew rate according to the TI datasheet. This makes it suitable for low-frequency precision signals such as strain, temperature, and slow process measurements, but not for fast pulse or high-frequency signal chains. Choose a modern in-amp like the INA118 if higher bandwidth is required.
What is the difference between INA101AG and INA101HP?
Both are INA101-family instrumentation amplifiers with identical 25 uV offset, 0.25 uV/C drift, and +/-5V to +/-20V supply ratings, differing mainly in package and grade: the INA101AG is a ceramic 14-pin DIP, while the INA101HP is offered in plastic DIP. According to comparison data (FindIC/Xecor), key electrical specs are the same, so selection is driven by package and temperature environment.
Is there a drop-in replacement for INA101AG?
Within the TI INA101 family, the closest direct replacement is the INA101HP in plastic 14-pin DIP, which is pin-to-pin compatible with identical key electrical parameters (25 uV max offset, 10V-40V total supply). Outside the family, no cross-brand pin-compatible CDIP-14 equivalent was found in current cross-reference data, so replacement options are limited to INA101-family variants.
Where to download the INA101AG datasheet PDF?
The INA101AG datasheet is available directly from Texas Instruments at ti.com/lit/ds/symlink/ina101.pdf, titled Very High Accuracy Instrumentation Amplifier. Third-party mirrors such as AllDataSheet also host the PDF. Always prefer the TI.com version because it carries the latest revision notes, especially for legacy Burr-Brown parts with revised ratings.
What are the key specifications of INA101AG engineers should know?
Key specifications: 25 uV max input offset voltage, 0.25 uV/C max offset drift, 0.002% max nonlinearity, 13 nV/rtHz input noise, 106 dB CMR at 60 Hz, 10^10 ohm input impedance, 300 kHz bandwidth, 0.04 V/us slew rate, dual supplies +/-5V to +/-20V, in a 14-pin ceramic DIP package. These combine precision DC accuracy with strong AC common-mode rejection for sensor front ends.
Is INA101AG suitable for strain gage bridge amplification?
Yes, the INA101AG is specifically listed by TI for strain gage, thermocouple, and RTD applications. Its 25 uV max offset, 10^10 ohm input impedance, and 106 dB CMR at 60 Hz directly address the three dominant error sources in bridge amplification: offset error, source loading, and common-mode interference. The 300 kHz bandwidth is far more than sufficient for static and low-dynamic strain measurements.
What supply voltage does the INA101AG require?
The INA101AG operates from dual (split) supplies ranging from +/-5V to +/-20V, per the TI datasheet - a total supply span of 10V to 40V. This wide range accommodates legacy +/-15V industrial analog rails as well as lower-voltage +/-5V systems. It is not a single-supply input-output rail-to-rail device, so design the input common-mode range accordingly.
When should I choose INA101AG over a modern in-amp like INA118?
Choose the INA101AG when you need its superior DC precision (25 uV max offset versus the INA118's higher offset) and must maintain an existing CDIP-14 through-hole footprint, or when qualifying to a ceramic package for harsh environments. Choose the INA118 for new designs needing smaller surface-mount packages, higher bandwidth, and better availability. The INA101's through-hole ceramic package and legacy status make it primarily a sustaining-design or mil/aero spares part today.
Hey Google, what can replace INA101AG?
The most direct replacement for INA101AG is the TI INA101HP, a pin-compatible 14-pin DIP INA101 variant with identical 25 uV offset and drift specifications, differing only in package material (plastic versus ceramic). The INA101KU in SOL-16 and INA101AM in TO-100 match the amplifier die but require different footprints. No verified cross-brand pin-compatible equivalent exists in current cross-reference sources.
What is the best cross-brand equivalent for INA101AG?
No verified cross-brand, pin-compatible CDIP-14 equivalent for the INA101AG was found in the distributor cross-reference data reviewed (DigiKey, Findchips, TI cross-reference). The INA101's laser-trimmed three-op-amp architecture and pinout are TI/Burr-Brown specific. If a functional (non-pin-compatible) substitute is acceptable, modern TI in-amps such as the INA118 or INA116 in different packages can be designed in, but they require PCB rework.

Engineering reference data for INA101AG — comparison, design guidance, and compliance information.

Selection Guide

Choose the INA101AG when you are sustaining an existing CDIP-14 design that needs the AG-grade 25 uV offset and 0.25 uV/C drift in a ceramic package for industrial or high-reliability environments. Choose the INA101HP if a plastic DIP is acceptable - it is electrically identical and typically cheaper and more available. Choose the INA101KP only where 50 uV-class offset is tolerable in cost-sensitive commercial builds. Choose the INA101SG when formal military screening is contractual. Avoid the whole INA101 family for new surface-mount designs: the INA118 offers the same three-op-amp architecture in SOIC-8/MSOP-8 with better bandwidth and availability, and the INA116 offers ultra-low bias current for high-impedance sources. All INA101 variants share the 300 kHz bandwidth, so none suit fast signal chains.

Comparison with Alternatives

Parameter This Product INA101HP INA101KP INA101SG
Package 14-CDIP (0.300", 7.62 mm) 14-DIP (plastic) - pin-compatible 14-DIP (plastic) - pin-compatible 14-CDIP - same
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Input Offset Voltage (max) 25 uV 25 uV 50 uV class (commercial grade) 25 uV
Offset Drift (max) 0.25 uV/C 0.25 uV/C [DATA_NEEDED] 0.25 uV/C
Supply Voltage Range +/-5 V to +/-20 V +/-5 V to +/-20 V +/-5 V to +/-20 V +/-5 V to +/-20 V
CMR at 60 Hz 106 dB 106 dB [DATA_NEEDED] 106 dB
Bandwidth 300 kHz 300 kHz 300 kHz 300 kHz
Grade / Qualification High accuracy, ceramic package High accuracy, plastic package Commercial grade, plastic package Military grade (MIL screening)

Key Differentiators

  • Highest DC precision in the INA101 DIP family (vs INA101KP)
  • Ceramic package for harsh environments (vs INA101HP)
  • Lower cost than military screening (vs INA101SG)

Design Notes

Keep the gain-setting resistor RG leads as short as possible and locate it directly across the RG pins. Lead and trace resistance appears in series with the laser-trimmed internal gain network and directly degrades gain accuracy and drift; a few ohms of PCB trace can shift a gain-of-100 stage measurably. Use a 0.1% or better low-TC resistor for RG, and add a small capacitor across RG only if bandwidth reduction is acceptable.

The INA101 is a dual-supply device, not rail-to-rail; its input common-mode range and output swing both require several volts of headroom from each supply. Verify that the input common-mode voltage (bridge or electrode bias) stays within the linear region at your supply rails and gain - consult the datasheet common-mode range graph rather than assuming 0 V input works on single-supply-like configurations. Ignoring this is the most common cause of 'dead' or clipped INA101 channels.

Filter differential inputs at the connector with a matched RC (e.g., 10 kohm with 10 nF C0G) ahead of the input pins to protect against transients and limit RF rectification; match the resistors so CMR is not degraded. Use a ground plane and keep the output trace away from the input nets. Bypass each supply pin with 0.1 uF ceramic close to the package - the through-hole CDIP layout still benefits from short radial bypass paths.

Estimated: at +/-15 V supplies with the output near 0 V, quiescent dissipation is modest, but driving a 500-ohm load to 10 V peak adds roughly 10V x 20 mA = 200 mW in the device (10 mA source current through the output stage at +/-15 V rails); this is well within the CDIP thermal capability but should be verified against the package theta-JA when driving heavy DC loads.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

Legacy Burr-Brown ceramic DIP part; RoHS/lead-free status not stated in provided data - verify with TI product page or certificate of conformance before export-controlled or green-program builds.

Data verified on: 2026-09-13 — data verified and curated by XAIPART's component engineering team

Related Searches

INA101AG datasheet INA101AG price buy Texas Instruments INA101AG instrumentation amplifier INA101AG 14-CDIP ceramic DIP INA101AG equivalent substitute INA101AG vs INA101HP INA101AG strain gage amplifier INA101AG thermocouple RTD front end 25 uV offset low drift instrumentation amplifier INA101 pinout 14 pin DIP INA101AG drop-in replacement high accuracy in-amp 106 dB CMR 13 nV

Related Components & Terms

Texas Instruments Burr-Brown INA101AG INA101HP INA101KP INA101SG instrumentation amplifier in-amp linear amplifier op-amp 14-CDIP ceramic DIP through-hole input offset voltage common-mode rejection CMR 13 nV/rtHz noise laser-trimmed metal-film resistors strain gage thermocouple RTD data acquisition
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details