ADM2484EBRWZ vs ISO1450BDWR Karşılaştırma

Ayrıntılı yan yana karşılaştırma ADM2484EBRWZ tarafından Analog Devices ve ISO1450BDWR tarafından Texas InstrumentsAnahtar özellikleri, elektriksel parametreleri, ambalajı, yaşam döngüsü durumu, fiyatlandırma ve mevcudiyeti karşılaştırarak tasarım gereksinimleriniz için en iyi bileşeni belirleyin.

Analog Devices
ADM2484EBRWZ ADM2484EBRWZ - Isolated RS-485 Transceiver | Analog Devices

ADM2484EBRWZ - Isolated RS-485 Transceiver | Analog Devices

ADM2484EBRWZ ✓ Aktif

Özellik Karşılaştırması

Parametre ADM2484EBRWZ ISO1450BDWR
Marka Analog Devices Texas Instruments
Kategori RS-485/RS-422 Interface ICs
Yaşam Döngüsü Durumu Aktif Aktif
Birim Fiyat (USD) $3,10 —
Type Isolated RS-485/RS-422 Transceiver —
Number of Channels 3 —
Isolation Voltage 5000 Vrms —
Veri Hızı 500 kbps —
CMTI 25 kV/µs —
ESD Protection ±15 kV —
Supply Voltage (Logic) 3.3 V or 5 V —
Supply Voltage (Bus) 5 V —
Duplex Half/Full Half
Paket 16-SOIC (0.295", 7.50mm Width) SOIC-16 wide-body (DW), 16 pins
İşletim Sıcaklığı -40°C to +85°C -40C to +125C
Montaj Türü Surface Mount Surface Mount
RoHS Durumu Compliant Compliant
Number of Drivers/Receivers 1/1 —
Propagation Delay [DATA_NEEDED: Propagation delay] —
Fonksiyon — Isolated half-duplex RS-485 / RS-422 transceiver
Data Rate (max) — 50 Mbps
Isolation Voltage (rms) — 5 kVrms (reinforced)
Number of Drivers / Receivers — 1/1
Receiver Hysteresis — [DATA_NEEDED: receiver hysteresis voltage]
Supply Voltage VCC1 (logic side) — 3 V to 5.5 V
Supply Voltage VCC2 (bus side) — Internally generated by isolated DC-DC
Bus Pin ESD (IEC 61000-4-2) — ±16 kV (air / contact, per datasheet)
Bus Pin ESD (HBM) — ±4 kV
IEC 61000-4-4 EFT Immunity — ±4 kV
Surge Immunity — [DATA_NEEDED: IEC 61000-4-5 surge rating]
Unit Load — 1/8 (up to 256 nodes on bus)
Common-Mode Range — Wide common-mode bus voltage range (per datasheet)
Termal Kapatma — Yes
Current Limiting — Yes
Low-Power Standby — Yes
MSL Seviyesi — 3 (per JEDEC J-STD-020)
Compliance Standards — TIA/EIA-485-A, TIA/EIA-422, IEC 61000-4-2, IEC 61000-4-4

Dökümanlar & Kaynaklar

Tüm Ürünleri Gözden Geçir BOM Oluştur Teklif İsteyin