MPX2202DP vs MPX2010DP Karşılaştırma
Ayrıntılı yan yana karşılaştırma MPX2202DP tarafından NXP Semiconductors ve MPX2010DP tarafından NXP SemiconductorsAnahtar özellikleri, elektriksel parametreleri, ambalajı, yaşam döngüsü durumu, fiyatlandırma ve mevcudiyeti karşılaştırarak tasarım gereksinimleriniz için en iyi bileşeni belirleyin.
Özellik Karşılaştırması
| Parametre | MPX2202DP | MPX2010DP |
|---|---|---|
| Marka | NXP Semiconductors | NXP Semiconductors |
| Kategori | Pressure Sensors | Pressure Sensors |
| Yaşam Döngüsü Durumu | Aktif | Aktif |
| Pressure Range | 0 to 200 kPa (0 to 29.01 PSI) | 0 to 10 kPa (0 to 1.45 PSI) |
| Pressure Type | Differential (dual port, tube inlet) | — |
| Besleme Gerilimi | 10 V typical | 10 V DC typical (max 16 V) |
| Full-Scale Span | 40 mV typical at 10 V supply | — |
| Offset | 0 mV typical | — |
| Linearity | 1.0% typical | ±0.05% (typ) |
| Pressure Hysteresis | 2.0% maximum | — |
| Temperature Compensated Range | 0 C to 85 C | — |
| Paket / Kas | 4-SIP Module (Case 867C) | — |
| Port Type | Dual tube, male, 0.19" (4.93 mm) tube | — |
| İşletim Sıcaklığı | -40 C to +125 C [DATA_NEEDED: confirm exact op-temp range from datasheet] | -40 °C to +125 °C |
| Çıkış Türü | Analog differential voltage | Analog voltage, Wheatstone bridge (mV level) |
| Technology | Silicon piezoresistive, on-chip temperature compensated and calibrated | Piezoresistive (silicon strain gauge bridge) |
| Montaj Türü | Through-hole (4-SIP tube inlet) | — |
| RoHS Durumu | RoHS compliant | Compliant |
| Duyarlılık Türü | — | Differential Pressure Sensor |
| Typical Full-Scale Span | — | 25 mV at 10 V excitation |
| Zero Pressure Offset | — | 0 mV nominally (±1.0 mV max) |
| Temperature Compensation | — | 0 °C to +85 °C (on-chip) |
| Response Time | — | 1.0 ms (typical) |
| Maximum Overpressure | — | 75 kPa |
| Burst Pressure | — | 200 kPa |
| Port Configuration | — | Dual ports (differential), 0.19 inch / 4.93 mm tubes |
| Package / Mounting | — | 4-SIP Module (through-hole with axial tubes) |
| Media Compatibility | — | Dry air or non-corrosive gas |