INA2126UG4 - 36V Dual Micropower Instrumentation Amplifier | TI
MPN: INA2126UG4 ✓ AktifINA2126UG4 Genel Bakış
An instrumentation amplifier is a signal-conditioning IC that amplifies the voltage difference between two input terminals while rejecting common-mode interference. The INA2126 belongs to the precision instrumentation amplifier hierarchy and supports accurate differential-signal acquisition. Its two-op-amp architecture combines low quiescent current with a wide operating-voltage range of ±1.35 V to ±18 V.
Key features include 175 µA of quiescent current per channel, 250 µV offset, and operation from a single 2.7 V supply or from dual ±18 V rails. The device is intended for low-level differential measurements where battery life, signal integrity, and compactness are important. Two channels in one package can reduce board area when multiple sensor inputs must be conditioned.
The 36 V maximum supply gives designers substantial transient and common-mode headroom in industrial environments, although the input common-mode range remains dependent on the selected supply and gain configuration. The precision-oriented internal architecture is intended to preserve small differential signals while reducing supply and common-mode errors. Designers should review gain, input range, output swing, and supply limits in the manufacturer datasheet before fixing system operating conditions.
Typical uses include bridge-sensor interfaces, current-shunt measurements, portable multimeter circuits, battery-powered sensor acquisition, medical monitoring equipment, and industrial process-control inputs. The low 175 µA-per-channel quiescent current is particularly valuable in portable systems where amplifier current directly affects available battery runtime.
Decoupling and layout are critical because the instrument-amplifier pins connect directly to low-level sensor signals. Place the supply bypass capacitor close to the positive and negative supply pins, connect the input return paths close to the amplifier, and use the differential inputs symmetrically. Validate the complete gain, common-mode range, output swing, noise, and settling-time combination on the target board.
Drop-in alternatifler için INA2126UG4 — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
Bu Serideki Variantlar
Yedek parça uyumlu olan aynı serideki modeller INA2126UG4 (aynı form faktörü ve ayağa oturma) — farklı olan Package, Mounting Type, Architecture, Channel Count, Quiescent Current.
INA2126U
✅ Yerleştirme ⚠️ Onaylanmamış ÖzelliklerFiyat için iletişime geçin
Veri Şablonunu Görüntüle →INA2126UI
✅ Yerleştirme ⚠️ Onaylanmamış Özellikler📋 Katalogda Olmayan Referans Alternatifi
INA2126UIT
✅ Yerleştirme ⚠️ Onaylanmamış Özellikler📋 Katalogda Olmayan Referans Alternatifi
INA2126UIR
✅ Yerleştirme ⚠️ Onaylanmamış Özellikler📋 Katalogda Olmayan Referans Alternatifi
INA126P
✅ Yerleştirme ⚠️ Onaylanmamış ÖzelliklerFiyat için iletişime geçin
Veri Şablonunu Görüntüle →INA2126UG4 Maksimum Değerlendirmeler & Elektriksel Özellikler
| Device Type | Dual precision instrumentation amplifier |
| Channel Count | 2 channels |
| Maximum Supply Voltage | 36 V |
| Supply Voltage Range | ±1.35 V to ±18 V |
| Single-Supply Minimum | 2.7 V |
| Durağan Akım | 175 µA per channel |
| Offset Voltage | 250 µV |
| Architecture | Two-op-amp instrumentation-amplifier design |
| Input Type | Differential |
| Signal Type | Low-level differential-signal acquisition |
| Paket | 16-pin SOIC, 3.90 mm width |
| Montaj Türü | Surface mount |
INA2126UG4 16-pin soic, 3.90 mm width Pin Yapısı Kılavuzu
INA2126UG4 (16-pin soic, 3.90 mm width paket) için pin yapısı. Bu analog bileşen, giriş, çıkış ve güç besleme pinleri içerir. Ofset null, telafi ve etkinleştirme pin yapılandırmaları için üretici veri kitapçığını referans alın. Sinyal işleme ve güç amplifikasyon devreleri için mükemmel bir bileşendir.
Ayrıntılı pin çıkış verisi mevcut değil: INA2126UG4.
Aşağıdaki veri sayfası tam pin konfigürasyonu için.
Tipik Uygulamalar
INA2126UG4 için uygundur 6 uygulamas: Battery-Powered Sensor Acquisition, Bridge-Sensor Signal Conditioning, Portable Multimeter Measurement, Current-Shunt Monitoring, Medical Monitoring Front End, Industrial Process Measurement.
Battery-Powered Sensor Acquisition
The INA2126UG4 fits battery-powered sensor nodes because each channel draws 175 µA of quiescent current and the device can operate from a 2.7 V single supply. Place the dual amplifier near the sensor interface, connect each differential input pair to the corresponding bridge or transducer, and use the available gain configuration to raise the small sensor voltage above the converter noise floor. The 36 V maximum supply also provides useful transient headroom in industrial sensor nodes. Its principal advantage over a discrete amplifier arrangement is the integrated common-mode rejection, gain control, and two-channel integration, which can reduce board area. Check the complete input common-mode range, output swing, settling behavior, and reference configuration against the actual sensor output before finalizing the gain.
Önerilen
Bridge-Sensor Signal Conditioning
The INA2126UG4 is appropriate for conditioning differential outputs from resistive bridges because it rejects common-mode voltage while preserving the smaller bridge differential signal. Its two channels allow two bridge elements to share one instrumentation-amplifier package, helping reduce board area in multi-axis force, pressure, or position sensors. The 175 µA-per-channel quiescent current supports portable test equipment, while the 36 V maximum supply provides margin for industrial excitation and transient environments. Configure the gain according to the manufacturer’s supported options and verify that the bridge excitation voltage remains inside the amplifier’s input common-mode range. Reference pins should be connected according to the datasheet for single-ended or differential output operation, and unused channel inputs must not be left floating.
Önerilen
Portable Multimeter Measurement
The INA2126UG4 supports portable multimeter and handheld measurement designs where low standby power is necessary between readings. Its dual instrumentation-amplifier channels can condition two low-level differential inputs while the 175 µA-per-channel quiescent current limits continuous battery drain. A practical implementation places the amplifier close to the input selector and protection network, then routes its outputs to an ADC. The device’s 36 V maximum supply is useful when the input network includes protected higher-voltage ranges, although the selected operating mode must preserve the allowed input common-mode range and output swing. Low-level measurement accuracy also depends on the reference implementation, input protection leakage, resistor matching, and PCB leakage, so evaluate the complete analog path rather than relying on amplifier offset alone.
Önerilen
Current-Shunt Monitoring
The INA2126UG4 can measure the small differential voltage produced across a current-shunt resistor when the shunt signal lies within the amplifier’s permitted input range. The two channels allow simultaneous monitoring of two power or control paths, while the 36 V-class supply capability suits higher-voltage systems requiring input protection. Position the shunt and amplifier to minimize trace resistance and avoid common-mode copper mismatches, because those mismatches convert directly into measurement error. The 175 µA-per-channel idle current also makes the device practical in portable battery equipment. Before selecting the gain, confirm that both the shunt voltage and common-mode voltage satisfy the manufacturer’s operating limits, and verify output swing at the required load. Add input filtering carefully so that shunt inductance does not create unstable or excessively delayed measurements.
Önerilen
Medical Monitoring Front End
The INA2126UG4 can serve as the analog front end for low-level differential monitoring signals when its specified electrical limits match the sensing architecture. The dual-channel arrangement supports paired sensing paths, and the 175 µA-per-channel quiescent current is beneficial in compact monitoring equipment. Its precision instrumentation-amplifier topology is intended to reject common-mode interference present on long sensor connections. Nevertheless, medical-system designers must independently validate input limits, protection behavior, isolation boundaries, leakage, noise, and applicable quality requirements; the component’s instrumentation-amplifier role does not itself establish medical certification. Keep sensitive input traces short, guard them appropriately, use clean references, and confirm the achieved noise and accuracy at the intended gain and bandwidth before using the circuit for patient-connected measurements.
Önerilen
Industrial Process Measurement
The INA2126UG4 is suitable for industrial process-measurement inputs where a small differential voltage must be amplified in the presence of a larger common-mode potential. Its 36 V maximum supply provides useful operating headroom, and two channels can monitor related variables without requiring two separate instrumentation-amplifier packages. The 175 µA-per-channel quiescent current favors distributed low-power sensing nodes. Use short differential routes, a solid ground reference, and supply bypass capacitors close to the device, while avoiding long unprotected traces adjacent to switching equipment. Validate the selected gain against the input common-mode range and output swing, and account for offset and gain error at the actual temperature. If the source is a resistive sensor with a non-grounded output, verify the reference connection in the manufacturer’s typical application circuit before fabrication.
Önerilen
Önerilen Ürünler Özeti
Mühendislik referans verileri: INA2126UG4 — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Alternatiflerle Karşılaştırma
| Parametre | Bu Ürün | INA2126U | INA2126UI | INA126P |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC |
| Maximum Supply Voltage | 36 V | 36 V | 36 V | 36 V |
| Supply Voltage Range | ±1.35 V to ±18 V | ±1.35 V to ±18 V | ±1.35 V to ±18 V | ±1.35 V to ±18 V |
| Quiescent Current | 175 µA per channel | 175 µA per channel | 175 µA per channel | 175 µA per channel |
Ana Farklılayıcılar
- Two measurement channels in one package (karşılaştırma:INA126P)
- Low quiescent demand for portable systems (karşılaştırma:INA2126U)
- 36 V supply capability (karşılaştırma:INA2126UI)
Tasarım Notları
Route each differential input as a closely coupled pair and connect the pair to the amplifier input pins without long stubs. Place the supply bypass capacitor directly between the supply pins and ground, and keep the reference connections short. Differential input traces should avoid switching-node copper and noisy digital return paths because common-mode conversion and parasitic pickup can dominate the small signal being measured.
Check the selected gain against the complete input common-mode range and output-voltage swing before schematic sign-off. The 175 µA-per-channel quiescent current indicates low intrinsic demand, but the input bias current, output load, reference current, and protection-network leakage still affect accuracy. Use the manufacturer’s gain and reference configuration diagrams rather than connecting both reference pins or both channels in an assumed manner.
Do not treat the 36 V maximum supply rating as permission to exceed the input common-mode range. A high-side shunt or powered sensor can exceed the permitted input voltage even when the power rails are correct. Add protection appropriate to the signal source, verify absolute-maximum limits after transients, and ensure unused inputs are biased rather than left floating. Production substitutions should be checked against the complete ordering table.
For low-level measurements, minimize loop area around the sensor, shunt, amplifier, and reference network. Place analog return current away from switching-converter paths and avoid sharing narrow copper segments between high-current and signal returns. If the source is far from the amplifier, account for cable capacitance, shielding, and common-mode range before choosing the highest available gain, since excessive bandwidth can increase noise or instability.
Uyumluluk Bilgisi
Compliance declarations were not established for the exact INA2126UG4 ordering code. Check the current Texas Instruments product page and material-compliance documentation before release.