AD549JHZ - 250 fA Electrometer Op Amp | Analog Devices
MPN: AD549JHZ ✓ فعالAD549JHZ جائزہ
An electrometer operational amplifier is a precision voltage amplifier designed to minimize input current while maintaining accurate DC operation. This places it in the operational-amplifier hierarchy within analog ICs and power-management instrumentation: operational amplifier → precision operational amplifier → electrometer amplifier → analog signal-chain IC. Such amplifiers are used when the source resistance, leakage current, or required measurement resolution would cause excessive error in a conventional voltage-feedback amplifier.
The AD549 uses Analog Devices Topgate JFET technology to achieve its ultralow input bias current. Its input offset voltage and input offset-voltage drift are laser trimmed for precision performance, while bias current is guaranteed over the common-mode range. These characteristics make the device suitable for pH electrodes, ion-selective electrodes, photodiodes, charge-sensitive measurement circuits, high-impedance sensors, and precision current-to-voltage conversion.
The device provides a gain-bandwidth product of 1 MHz and a slew rate of 3 V/μs. Its bandwidth is sufficient for low-frequency precision signal processing, while the 1 MHz value also supports modest-bandwidth applications such as active filters and buffered sensor stages. Because an electrometer amplifier prioritizes input-current performance over wide bandwidth, applications should account for its gain-bandwidth limit when defining closed-loop bandwidth or settling time.
Typical uses include pH and electrochemical analysis, gas and chemical sensors, photodiode current measurement, electrometer-compatible instrumentation, precision integrators, and low-droop sample-and-hold circuits. The hermetic TO-99 construction can also suit precision laboratory and industrial equipment where environmental isolation and long-term stability are important design priorities.
Designers should keep leakage paths under control by using guarded PCB traces, clean connectors, suitable insulation, and careful biasing of the input network. A precision measurement design should also verify input common-mode range, output swing, noise, stability with the selected feedback network, and the power-supply arrangement under the manufacturer's recommended operating conditions.
This product page consolidates the AD549JHZ specifications, grade distinctions, verified drop-in alternatives, package information, and practical design guidance into an engineering-oriented selection resource. It also identifies which characteristics distinguish the J grade from the K and L grades, helping designers make a defensible precision-versus-requirement decision before layout work begins.
کے لیے ڈراپ اِن متبادل AD549JHZ — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔
اس سیریز میں مختلف ورژن
اسی سیریز کے ماڈلز جو ڈراپ اِن مطابقت رکھتے ہیں AD549JHZ (یکساں فارم فیکٹر اور فٹ پرنٹ) — میں مختلف Package, Package Type, Slew Rate, Amplifier Type, Number of Channels.
AD549KHZ
✅ ڈراپ-اِنقیمت کے لیے رابطہ کریں
ڈیٹا شیٹ دیکھیں →AD549LHZ
✅ ڈراپ-اِنقیمت کے لیے رابطہ کریں
ڈیٹا شیٹ دیکھیں →AD549SH/883B
✅ ڈراپ-اِن📋 حوالہ جاتی متبادل (کیٹلاگ میں نہیں)
AD549LH
✅ ڈراپ-اِنقیمت کے لیے رابطہ کریں
ڈیٹا شیٹ دیکھیں →OPA128LM
✅ ڈراپ-اِن📋 حوالہ جاتی متبادل (کیٹلاگ میں نہیں)
AD549JHZ زیادہ سے زیادہ ریٹنگز اور برقی خصوصیات
| Amplifier Type | Electrometer operational amplifier |
| Number of Channels | 1 channel |
| Input Bias Current Maximum | 250 fA for AD549J grade |
| Input Offset Voltage Maximum | 1.00 mV for AD549J grade |
| Input Offset Voltage Drift Maximum | 15 μV/°C |
| Gain-Bandwidth Product | 1 MHz |
| Slew Rate | 3 V/μs |
| Supply Voltage Range | ±5 V to ±18 V |
| Input Technology | Topgate JFET |
| Offset Adjustment Method | Laser trimmed |
| Package Type | TO-99-8 hermetic package |
| پنز کی تعداد | 8 pins |
| ماؤنٹنگ اسٹائل | Through-hole |
| Bias-Current Guarantee | Guaranteed over the common-mode voltage range |
| RoHS اسٹیٹس | unknown |
| REACH Status | unknown |
AD549JHZ to-99-8 hermetic package پن کنفیگریشن گائیڈ
AD549JHZ (to-99-8 hermetic package پیکیج) کے لیے پن کنفیگریشن۔ اس اینالاگ کمپوننٹ میں اِن پٹ، آؤٹ پٹ اور پاور سپلائی پنز شامل ہیں۔ آفسیٹ نل، کمپنسیشن اور اِن ایبل پن کنفیگریشنز کے لیے مینوفیکچرر کے ڈیٹا شیٹ سے رجوع کریں۔ سگنل کنڈیشننگ اور ایمپلیفائر سرکٹس کے لیے مثالی۔
کے لیے تفصیلی پن آؤٹ ڈیٹا دستیاب نہیں AD549JHZ.
رجوع کریں ڈیٹا شیٹ مکمل پن کنفیگریشن کے لیے۔
عام استعمالات
AD549JHZ کے لیے موزوں ہے 6 ایپلیکیشنs: pH and Electrochemical Sensor Interface, Photodiode Current Measurement, Precision Transimpedance Amplifier, Precision Integrator and Low-Droop Sample-and-Hold, High-Impedance Instrumentation Buffer, Precision Laboratory Signal Conditioning.
pH and Electrochemical Sensor Interface
The AD549JHZ suits pH and electrochemical measurements because the 250 fA maximum input bias current produces very little loading on high-impedance electrodes. It can be used in a non-inverting buffer or transimpedance stage where preserving the small sensor current is more important than wide bandwidth. The 1 MHz gain-bandwidth product supports low-frequency chemical measurements, while the 15 μV/°C maximum offset drift supports stable DC behavior across temperature changes. Board-level leakage can still exceed the amplifier input current, so guarded traces, clean insulation, and careful connector selection remain essential to realizing the precision of the AD549J grade.
تجویز کردہ
Photodiode Current Measurement
The AD549JHZ is useful for low-level photodiode current measurement because its 250 fA maximum input bias current limits the error introduced by the sensing node. It can be configured as a transimpedance amplifier for weak optical signals where feedback resistance is large and leakage must remain small. The 1 MHz gain-bandwidth product provides useful signal bandwidth, but photodiode capacitance and the 3 V/μs slew rate must be considered when selecting the feedback network. Guarded high-impedance traces and low-leakage board materials help preserve the measured current, making this device appropriate for laboratory photometry and precision industrial light sensors.
تجویز کردہ
Precision Transimpedance Amplifier
The AD549JHZ fits precision transimpedance amplification because its 250 fA maximum bias current places little error current into the source branch. This matters when converting microampere or picoampere sensor currents into measurable voltages through a large feedback resistor. The 1 MHz gain-bandwidth product allows moderate closed-loop bandwidth, although the exact bandwidth must be recalculated with the feedback resistor and source capacitance. The amplifier's laser-trimmed offset voltage and specified drift of no more than 15 μV/°C support stable measurements, while clean layout around the high-impedance node remains essential.
تجویز کردہ
Precision Integrator and Low-Droop Sample-and-Hold
The AD549JHZ can be used in precision integration and low-droop sample-and-hold circuits where input leakage would otherwise charge or discharge the integrating capacitor. Its 250 fA maximum input bias current is especially useful with long integration intervals and high-value capacitors. The 1 MHz gain-bandwidth product and 3 V/μs slew rate permit practical settling for moderately fast analog signal processing, though the final timing must include op-amp noise and comparator or switch effects. Use low-leakage capacitors and guard structures around the summing node to preserve the benefit of the low input current.
تجویز کردہ
High-Impedance Instrumentation Buffer
The AD549JHZ works as the input stage of a high-impedance instrumentation buffer when the source impedance is high enough that conventional op-amp input currents would cause unacceptable error. Its 250 fA maximum input bias current and common-mode-range guarantee for bias current support reliable operation across the sensor's operating voltage. The 1 MHz bandwidth is ample for many temperature, humidity, chemical, and laboratory transducer signals. In a multi-amplifier instrumentation design, verify bias-current cancellation, common-mode limits, noise, and resistor matching rather than assuming the amplifier alone determines total accuracy.
تجویز کردہ
Precision Laboratory Signal Conditioning
The AD549JHZ is appropriate for precision laboratory signal conditioning when slow-changing signals must be measured without significant current drawn from the source. Its low input current, 1.00 mV maximum offset voltage for the J grade, and hermetic 8-pin TO-99 package suit measurement modules intended for controlled environments. The 1 MHz gain-bandwidth product can support active filtering and moderate-frequency conditioning, but the gain error and settling must be checked at the intended operating frequency. Guarded boards, low-leakage connectors, and careful grounding complement the device's input characteristics.
تجویز کردہ
تجویز کردہ پروڈکٹس کا خلاصہ
کے لیے انجینئرنگ ریفرنس ڈیٹا AD549JHZ — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔
انتخاب کی گائیڈ
متبادلات کے ساتھ موازنہ
| پیرامیٹر | یہ پروڈکٹ | AD549KHZ | AD549LHZ | AD549SH/883B | AD549LH | OPA128LM |
|---|---|---|---|---|---|---|
| Package | TO-99-8 hermetic package | TO-99-8 hermetic package | TO-99-8 hermetic package | TO-99-8 hermetic package | TO-99-8 hermetic package | TO-99-8 hermetic package |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Application Class | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Low-bias-current precision operational amplifier |
اہم امتیازی خصوصیات
- AD549 family architecture provides a practical precision upgrade path (بمقابلہAD549KHZ)
- The L grade offers the lowest stated AD549 bias-current limit (بمقابلہAD549LHZ)
- The cross-brand OPA128LM provides tighter published offset limits (بمقابلہOPA128LM)
ڈیزائن نوٹس
Protect the input node from leakage with guarded traces, a guarded input structure, clean connectors, and low-contaminating PCB materials. The AD549JHZ permits 250 fA maximum input bias current, so a contaminated surface, flux residue, or unprotected solder trace can create an error comparable to or larger than the amplifier's specified input current. Keep the high-impedance input away from power-switching nodes, inductors, and grounded copper that could increase parasitic coupling.
Do not treat the 1 MHz gain-bandwidth product as the complete signal-bandwidth specification. The usable closed-loop bandwidth also depends on noise gain, feedback resistance, source capacitance, and the selected compensation network. Check settling time against the 3 V/μs slew rate and account for the 15 μV/°C maximum input-offset drift when defining the measurement accuracy over temperature.
Use the manufacturer's TO-99 pin-description table when assigning PCB holes and keep sensitive input traces short and appropriately guarded. Bypass power pins with the recommended local capacitance and route supply current away from the input node. Because the AD549JHZ is intended for high-impedance measurements, layout leakage and contamination may dominate the error budget even when the amplifier itself is precision trimmed.
Operate the AD549JHZ within its specified ±5 V to ±18 V supply range and verify output swing across the full signal range. For bipolar operation, ensure both supply rails are stable and referenced correctly. Use local decoupling to prevent supply disturbances from modulating the measured node, and account for the amplifier's quiescent and output-current behavior when sizing the supply for the selected feedback network.
تعمیل کی معلومات
The current manufacturer product page and datasheet identify the AD549 as a precision electrometer operational amplifier in a hermetic TO-99 package. A complete current RoHS, REACH, lead-free, halogen-free, and conflict-minerals declaration was not identified in the retrieved material; AEC-Q100 automotive qualification is not indicated for the standard AD549JHZ grade.