AD549JHZ - 250 fA Electrometer Op Amp | Analog Devices
Référence : AD549JHZ ✓ ActifAD549JHZ Présentation
An electrometer operational amplifier is a precision voltage amplifier designed to minimize input current while maintaining accurate DC operation. This places it in the operational-amplifier hierarchy within analog ICs and power-management instrumentation: operational amplifier → precision operational amplifier → electrometer amplifier → analog signal-chain IC. Such amplifiers are used when the source resistance, leakage current, or required measurement resolution would cause excessive error in a conventional voltage-feedback amplifier.
The AD549 uses Analog Devices Topgate JFET technology to achieve its ultralow input bias current. Its input offset voltage and input offset-voltage drift are laser trimmed for precision performance, while bias current is guaranteed over the common-mode range. These characteristics make the device suitable for pH electrodes, ion-selective electrodes, photodiodes, charge-sensitive measurement circuits, high-impedance sensors, and precision current-to-voltage conversion.
The device provides a gain-bandwidth product of 1 MHz and a slew rate of 3 V/μs. Its bandwidth is sufficient for low-frequency precision signal processing, while the 1 MHz value also supports modest-bandwidth applications such as active filters and buffered sensor stages. Because an electrometer amplifier prioritizes input-current performance over wide bandwidth, applications should account for its gain-bandwidth limit when defining closed-loop bandwidth or settling time.
Typical uses include pH and electrochemical analysis, gas and chemical sensors, photodiode current measurement, electrometer-compatible instrumentation, precision integrators, and low-droop sample-and-hold circuits. The hermetic TO-99 construction can also suit precision laboratory and industrial equipment where environmental isolation and long-term stability are important design priorities.
Designers should keep leakage paths under control by using guarded PCB traces, clean connectors, suitable insulation, and careful biasing of the input network. A precision measurement design should also verify input common-mode range, output swing, noise, stability with the selected feedback network, and the power-supply arrangement under the manufacturer's recommended operating conditions.
This product page consolidates the AD549JHZ specifications, grade distinctions, verified drop-in alternatives, package information, and practical design guidance into an engineering-oriented selection resource. It also identifies which characteristics distinguish the J grade from the K and L grades, helping designers make a defensible precision-versus-requirement decision before layout work begins.
Alternatives de remplacement direct pour AD549JHZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec AD549JHZ (même facteur de forme et même empreinte) — différant par Package, Package Type, Slew Rate, Amplifier Type, Number of Channels.
AD549KHZ
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →AD549LHZ
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →AD549SH/883B
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AD549LH
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →OPA128LM
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AD549JHZ Valeurs maximales et caractéristiques électriques
| Amplifier Type | Electrometer operational amplifier |
| Number of Channels | 1 channel |
| Input Bias Current Maximum | 250 fA for AD549J grade |
| Input Offset Voltage Maximum | 1.00 mV for AD549J grade |
| Input Offset Voltage Drift Maximum | 15 μV/°C |
| Gain-Bandwidth Product | 1 MHz |
| Slew Rate | 3 V/μs |
| Supply Voltage Range | ±5 V to ±18 V |
| Input Technology | Topgate JFET |
| Offset Adjustment Method | Laser trimmed |
| Package Type | TO-99-8 hermetic package |
| Nombre de broches | 8 pins |
| Style de montage | Through-hole |
| Bias-Current Guarantee | Guaranteed over the common-mode voltage range |
| Statut RoHS | unknown |
| REACH Status | unknown |
Guide de configuration des broches du AD549JHZ to-99-8 hermetic package
Configuration des broches du AD549JHZ (boîtier to-99-8 hermetic package). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour AD549JHZ.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AD549JHZ convient pour 6 applications: pH and Electrochemical Sensor Interface, Photodiode Current Measurement, Precision Transimpedance Amplifier, Precision Integrator and Low-Droop Sample-and-Hold, High-Impedance Instrumentation Buffer, Precision Laboratory Signal Conditioning.
pH and Electrochemical Sensor Interface
The AD549JHZ suits pH and electrochemical measurements because the 250 fA maximum input bias current produces very little loading on high-impedance electrodes. It can be used in a non-inverting buffer or transimpedance stage where preserving the small sensor current is more important than wide bandwidth. The 1 MHz gain-bandwidth product supports low-frequency chemical measurements, while the 15 μV/°C maximum offset drift supports stable DC behavior across temperature changes. Board-level leakage can still exceed the amplifier input current, so guarded traces, clean insulation, and careful connector selection remain essential to realizing the precision of the AD549J grade.
Recommandé
Photodiode Current Measurement
The AD549JHZ is useful for low-level photodiode current measurement because its 250 fA maximum input bias current limits the error introduced by the sensing node. It can be configured as a transimpedance amplifier for weak optical signals where feedback resistance is large and leakage must remain small. The 1 MHz gain-bandwidth product provides useful signal bandwidth, but photodiode capacitance and the 3 V/μs slew rate must be considered when selecting the feedback network. Guarded high-impedance traces and low-leakage board materials help preserve the measured current, making this device appropriate for laboratory photometry and precision industrial light sensors.
Recommandé
Precision Transimpedance Amplifier
The AD549JHZ fits precision transimpedance amplification because its 250 fA maximum bias current places little error current into the source branch. This matters when converting microampere or picoampere sensor currents into measurable voltages through a large feedback resistor. The 1 MHz gain-bandwidth product allows moderate closed-loop bandwidth, although the exact bandwidth must be recalculated with the feedback resistor and source capacitance. The amplifier's laser-trimmed offset voltage and specified drift of no more than 15 μV/°C support stable measurements, while clean layout around the high-impedance node remains essential.
Recommandé
Precision Integrator and Low-Droop Sample-and-Hold
The AD549JHZ can be used in precision integration and low-droop sample-and-hold circuits where input leakage would otherwise charge or discharge the integrating capacitor. Its 250 fA maximum input bias current is especially useful with long integration intervals and high-value capacitors. The 1 MHz gain-bandwidth product and 3 V/μs slew rate permit practical settling for moderately fast analog signal processing, though the final timing must include op-amp noise and comparator or switch effects. Use low-leakage capacitors and guard structures around the summing node to preserve the benefit of the low input current.
Recommandé
High-Impedance Instrumentation Buffer
The AD549JHZ works as the input stage of a high-impedance instrumentation buffer when the source impedance is high enough that conventional op-amp input currents would cause unacceptable error. Its 250 fA maximum input bias current and common-mode-range guarantee for bias current support reliable operation across the sensor's operating voltage. The 1 MHz bandwidth is ample for many temperature, humidity, chemical, and laboratory transducer signals. In a multi-amplifier instrumentation design, verify bias-current cancellation, common-mode limits, noise, and resistor matching rather than assuming the amplifier alone determines total accuracy.
Recommandé
Precision Laboratory Signal Conditioning
The AD549JHZ is appropriate for precision laboratory signal conditioning when slow-changing signals must be measured without significant current drawn from the source. Its low input current, 1.00 mV maximum offset voltage for the J grade, and hermetic 8-pin TO-99 package suit measurement modules intended for controlled environments. The 1 MHz gain-bandwidth product can support active filtering and moderate-frequency conditioning, but the gain error and settling must be checked at the intended operating frequency. Guarded boards, low-leakage connectors, and careful grounding complement the device's input characteristics.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AD549JHZ — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD549KHZ | AD549LHZ | AD549SH/883B | AD549LH | OPA128LM |
|---|---|---|---|---|---|---|
| Package | TO-99-8 hermetic package | TO-99-8 hermetic package | TO-99-8 hermetic package | TO-99-8 hermetic package | TO-99-8 hermetic package | TO-99-8 hermetic package |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Application Class | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Low-bias-current precision operational amplifier |
Principaux différenciateurs
- AD549 family architecture provides a practical precision upgrade path (vs AD549KHZ)
- The L grade offers the lowest stated AD549 bias-current limit (vs AD549LHZ)
- The cross-brand OPA128LM provides tighter published offset limits (vs OPA128LM)
Notes de conception
Protect the input node from leakage with guarded traces, a guarded input structure, clean connectors, and low-contaminating PCB materials. The AD549JHZ permits 250 fA maximum input bias current, so a contaminated surface, flux residue, or unprotected solder trace can create an error comparable to or larger than the amplifier's specified input current. Keep the high-impedance input away from power-switching nodes, inductors, and grounded copper that could increase parasitic coupling.
Do not treat the 1 MHz gain-bandwidth product as the complete signal-bandwidth specification. The usable closed-loop bandwidth also depends on noise gain, feedback resistance, source capacitance, and the selected compensation network. Check settling time against the 3 V/μs slew rate and account for the 15 μV/°C maximum input-offset drift when defining the measurement accuracy over temperature.
Use the manufacturer's TO-99 pin-description table when assigning PCB holes and keep sensitive input traces short and appropriately guarded. Bypass power pins with the recommended local capacitance and route supply current away from the input node. Because the AD549JHZ is intended for high-impedance measurements, layout leakage and contamination may dominate the error budget even when the amplifier itself is precision trimmed.
Operate the AD549JHZ within its specified ±5 V to ±18 V supply range and verify output swing across the full signal range. For bipolar operation, ensure both supply rails are stable and referenced correctly. Use local decoupling to prevent supply disturbances from modulating the measured node, and account for the amplifier's quiescent and output-current behavior when sizing the supply for the selected feedback network.
Informations de conformité
The current manufacturer product page and datasheet identify the AD549 as a precision electrometer operational amplifier in a hermetic TO-99 package. A complete current RoHS, REACH, lead-free, halogen-free, and conflict-minerals declaration was not identified in the retrieved material; AEC-Q100 automotive qualification is not indicated for the standard AD549JHZ grade.