Analog Devices

AD549JHZ - 250 fA Electrometer Op Amp | Analog Devices

MPN: AD549JHZ ✓ Aktif
1.00 mV for AD549J grade Vdss 250 fA for AD549J grade Id TO-99-8 hermetic package Package
MOQ: 1 |

AD549JHZ Genel Bakış

The Analog Devices AD549JHZ is a single-channel electrometer operational amplifier with a maximum input bias current of 250 fA, a maximum input offset voltage of 1.00 mV, and a maximum offset-voltage drift of 15 μV/°C. It is supplied in an 8-pin hermetic TO-99 package and operates from ±5 V to ±18 V. The AD549JHZ is the AD549J grade, distinguished from the AD549K and AD549L grades by their progressively tighter input-bias-current and offset-voltage limits.

An electrometer operational amplifier is a precision voltage amplifier designed to minimize input current while maintaining accurate DC operation. This places it in the operational-amplifier hierarchy within analog ICs and power-management instrumentation: operational amplifier → precision operational amplifier → electrometer amplifier → analog signal-chain IC. Such amplifiers are used when the source resistance, leakage current, or required measurement resolution would cause excessive error in a conventional voltage-feedback amplifier.

The AD549 uses Analog Devices Topgate JFET technology to achieve its ultralow input bias current. Its input offset voltage and input offset-voltage drift are laser trimmed for precision performance, while bias current is guaranteed over the common-mode range. These characteristics make the device suitable for pH electrodes, ion-selective electrodes, photodiodes, charge-sensitive measurement circuits, high-impedance sensors, and precision current-to-voltage conversion.

The device provides a gain-bandwidth product of 1 MHz and a slew rate of 3 V/μs. Its bandwidth is sufficient for low-frequency precision signal processing, while the 1 MHz value also supports modest-bandwidth applications such as active filters and buffered sensor stages. Because an electrometer amplifier prioritizes input-current performance over wide bandwidth, applications should account for its gain-bandwidth limit when defining closed-loop bandwidth or settling time.

Typical uses include pH and electrochemical analysis, gas and chemical sensors, photodiode current measurement, electrometer-compatible instrumentation, precision integrators, and low-droop sample-and-hold circuits. The hermetic TO-99 construction can also suit precision laboratory and industrial equipment where environmental isolation and long-term stability are important design priorities.

Designers should keep leakage paths under control by using guarded PCB traces, clean connectors, suitable insulation, and careful biasing of the input network. A precision measurement design should also verify input common-mode range, output swing, noise, stability with the selected feedback network, and the power-supply arrangement under the manufacturer's recommended operating conditions.

This product page consolidates the AD549JHZ specifications, grade distinctions, verified drop-in alternatives, package information, and practical design guidance into an engineering-oriented selection resource. It also identifies which characteristics distinguish the J grade from the K and L grades, helping designers make a defensible precision-versus-requirement decision before layout work begins.

Drop-in alternatifler için AD549JHZ — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.

Bu Serideki Variantlar

Yedek parça uyumlu olan aynı serideki modeller AD549JHZ (aynı form faktörü ve ayağa oturma) — farklı olan Package, Package Type, Slew Rate, Amplifier Type, Number of Channels.

Analog Devices
Package Type: TO-99-8 hermetic
Slew Rate: 3 V/us
İle Karşılaştır AD549JHZ →
Analog Devices
Package Type: TO-99 hermetic, 8 pins
Slew Rate: 3 V/µs
Number of Channels: 1 amplifier
İle Karşılaştır AD549JHZ →
Analog Devices
Package: 8-pin hermetic TO-99
İle Karşılaştır AD549JHZ →
Analog Devices
Package: TO-99-8 metal can
İle Karşılaştır AD549JHZ →
Texas Instruments
Package: TO-99-8 metal can, 8 pins
Amplifier Type: Precision unity-gain differential amplifier
İle Karşılaştır AD549JHZ →

AD549KHZ

✅ Yerleştirme
Analog Devices
📦 TO-99-8 hermetic package
Electrometer operational amplifier · 1 amplifier · Monolithic voltage-feedback operational amplifier · 1 MHz · 3 V/µs · ±5 V to ±18 V · 100 fA · 0.50 mV

Fiyat için iletişime geçin

Veri Şablonunu Görüntüle →

AD549LHZ

✅ Yerleştirme
Analog Devices
📦 TO-99-8 hermetic package
Single-circuit electrometer operational amplifier · Topgate JFET · 1 MHz · 1 circuit · Electrometer operational amplifier

Fiyat için iletişime geçin

Veri Şablonunu Görüntüle →

AD549SH/883B

✅ Yerleştirme
📦 TO-99-8 hermetic package
Same AD549 electrometer architecture and 8-pin TO-99 format, with grade and screening differences requiring verification against the application specification.

📋 Katalogda Olmayan Referans Alternatifi

AD549LH

✅ Yerleştirme
Analog Devices
📦 TO-99-8 hermetic package
Single electrometer operational amplifier · 1 amplifier · Topgate JFET · 1 MHz · Laser trimmed

Fiyat için iletişime geçin

Veri Şablonunu Görüntüle →

OPA128LM

✅ Yerleştirme
📦 TO-99-8 hermetic package
Maximum bias current improves from 250 fA to 75 fA and maximum offset voltage improves from 1.00 mV to 500 μV.

📋 Katalogda Olmayan Referans Alternatifi

AD549JHZ Maksimum Değerlendirmeler & Elektriksel Özellikler

Amplifier Type Electrometer operational amplifier
Number of Channels 1 channel
Input Bias Current Maximum 250 fA for AD549J grade
Input Offset Voltage Maximum 1.00 mV for AD549J grade
Input Offset Voltage Drift Maximum 15 μV/°C
Gain-Bandwidth Product 1 MHz
Slew Rate 3 V/μs
Supply Voltage Range ±5 V to ±18 V
Input Technology Topgate JFET
Offset Adjustment Method Laser trimmed
Package Type TO-99-8 hermetic package
Pin Sayısı 8 pins
Montaj Stili Through-hole
Bias-Current Guarantee Guaranteed over the common-mode voltage range
RoHS Durumu unknown
REACH Status unknown

AD549JHZ to-99-8 hermetic package Pin Yapısı Kılavuzu

AD549JHZ (to-99-8 hermetic package paket) için pin yapısı. Bu analog bileşen, giriş, çıkış ve güç besleme pinleri içerir. Ofset null, telafi ve etkinleştirme pin yapılandırmaları için üretici veri kitapçığını referans alın. Sinyal işleme ve güç amplifikasyon devreleri için mükemmel bir bileşendir.

to-99-8 hermetic package paket pin çizelgesi için AD549JHZ

Ayrıntılı pin çıkış verisi mevcut değil: AD549JHZ.

Aşağıdaki veri sayfası tam pin konfigürasyonu için.

Tipik Uygulamalar

AD549JHZ için uygundur 6 uygulamas: pH and Electrochemical Sensor Interface, Photodiode Current Measurement, Precision Transimpedance Amplifier, Precision Integrator and Low-Droop Sample-and-Hold, High-Impedance Instrumentation Buffer, Precision Laboratory Signal Conditioning.

🧪

pH and Electrochemical Sensor Interface

The AD549JHZ suits pH and electrochemical measurements because the 250 fA maximum input bias current produces very little loading on high-impedance electrodes. It can be used in a non-inverting buffer or transimpedance stage where preserving the small sensor current is more important than wide bandwidth. The 1 MHz gain-bandwidth product supports low-frequency chemical measurements, while the 15 μV/°C maximum offset drift supports stable DC behavior across temperature changes. Board-level leakage can still exceed the amplifier input current, so guarded traces, clean insulation, and careful connector selection remain essential to realizing the precision of the AD549J grade.

📷

Photodiode Current Measurement

The AD549JHZ is useful for low-level photodiode current measurement because its 250 fA maximum input bias current limits the error introduced by the sensing node. It can be configured as a transimpedance amplifier for weak optical signals where feedback resistance is large and leakage must remain small. The 1 MHz gain-bandwidth product provides useful signal bandwidth, but photodiode capacitance and the 3 V/μs slew rate must be considered when selecting the feedback network. Guarded high-impedance traces and low-leakage board materials help preserve the measured current, making this device appropriate for laboratory photometry and precision industrial light sensors.

⚡

Precision Transimpedance Amplifier

The AD549JHZ fits precision transimpedance amplification because its 250 fA maximum bias current places little error current into the source branch. This matters when converting microampere or picoampere sensor currents into measurable voltages through a large feedback resistor. The 1 MHz gain-bandwidth product allows moderate closed-loop bandwidth, although the exact bandwidth must be recalculated with the feedback resistor and source capacitance. The amplifier's laser-trimmed offset voltage and specified drift of no more than 15 μV/°C support stable measurements, while clean layout around the high-impedance node remains essential.

📊

Precision Integrator and Low-Droop Sample-and-Hold

The AD549JHZ can be used in precision integration and low-droop sample-and-hold circuits where input leakage would otherwise charge or discharge the integrating capacitor. Its 250 fA maximum input bias current is especially useful with long integration intervals and high-value capacitors. The 1 MHz gain-bandwidth product and 3 V/μs slew rate permit practical settling for moderately fast analog signal processing, though the final timing must include op-amp noise and comparator or switch effects. Use low-leakage capacitors and guard structures around the summing node to preserve the benefit of the low input current.

🏭

High-Impedance Instrumentation Buffer

The AD549JHZ works as the input stage of a high-impedance instrumentation buffer when the source impedance is high enough that conventional op-amp input currents would cause unacceptable error. Its 250 fA maximum input bias current and common-mode-range guarantee for bias current support reliable operation across the sensor's operating voltage. The 1 MHz bandwidth is ample for many temperature, humidity, chemical, and laboratory transducer signals. In a multi-amplifier instrumentation design, verify bias-current cancellation, common-mode limits, noise, and resistor matching rather than assuming the amplifier alone determines total accuracy.

🔬

Precision Laboratory Signal Conditioning

The AD549JHZ is appropriate for precision laboratory signal conditioning when slow-changing signals must be measured without significant current drawn from the source. Its low input current, 1.00 mV maximum offset voltage for the J grade, and hermetic 8-pin TO-99 package suit measurement modules intended for controlled environments. The 1 MHz gain-bandwidth product can support active filtering and moderate-frequency conditioning, but the gain error and settling must be checked at the intended operating frequency. Guarded boards, low-leakage connectors, and careful grounding complement the device's input characteristics.

What are the key specifications of AD549JHZ that engineers should know?
The AD549JHZ is a single-channel electrometer operational amplifier with 250 fA maximum input bias current, 1.00 mV maximum input offset voltage, 15 μV/°C maximum offset drift, 1 MHz gain-bandwidth product, and 3 V/μs slew rate. According to the Analog Devices AD549 datasheet, it uses Topgate JFET technology, is laser trimmed, and operates from ±5 V to ±18 V in an 8-pin hermetic TO-99 package.
What is the input bias current of AD549JHZ?
The AD549JHZ has a maximum input bias current of 250 fA because it is the AD549J grade. Analog Devices specifies the lower AD549K grade at 100 fA maximum and the AD549L grade at 60 fA maximum. Bias current is guaranteed over the device's common-mode voltage range, making the J grade appropriate when measured leakage can affect the accuracy of high-impedance source measurements.
Where can I download the AD549JHZ datasheet PDF?
The official AD549JHZ datasheet PDF is available from Analog Devices through the AD549 data-sheet link on this page. The document describes the device as a monolithic electrometer operational amplifier using Topgate JFET technology. For a complete implementation, use the manufacturer's pin-description table, electrical-characteristics tables, and application guidance rather than relying only on distributor summaries.
Where can I find the AD549JHZ pinout?
Use the pin-description table and package drawing in the Analog Devices AD549 datasheet to assign the eight TO-99 leads. The product is packaged as TO-99-8 and is pin compatible with standard FET and electrometer operational amplifiers, as stated on the manufacturer's AD549 product page. Confirm the exact lead numbering against the drawing before assigning PCB pads or probing the device.
AD549JHZ vs AD549KHZ - which is better for precision measurements?
The AD549KHZ is preferable when tighter DC error specifications justify selecting the K grade. The AD549JHZ permits 250 fA maximum bias current and 1.00 mV maximum offset voltage, whereas the AD549K grade permits 100 fA maximum bias current and 0.50 mV maximum offset voltage. Both are AD549 family members in the same TO-99 footprint, but the exact K-grade offset-drift limit should also be checked against the application requirements.
AD549JHZ vs AD549LHZ - what is the difference?
The AD549LHZ offers tighter electrometer-grade precision than the AD549JHZ. The AD549JHZ permits 250 fA maximum bias current, while the AD549L grade permits 60 fA maximum; the L grade is also the tighter offset-voltage grade. According to the comparison information for these devices, both retain the same core architecture, TO-99 package, and pinout, making grade selection a specification decision rather than a footprint change.
When should I choose AD549JHZ over AD549KHZ or AD549LHZ?
Choose the AD549JHZ when its 250 fA maximum input bias current and 1.00 mV maximum offset voltage satisfy the measurement error budget. Move to the AD549KHZ for a 100 fA maximum bias-current limit and 0.50 mV maximum offset voltage, or to the AD549LHZ for the 60 fA maximum AD549L grade. The tighter grades reduce input-current and DC-offset errors but require a quantified benefit from the additional precision.
What is the best drop-in replacement for AD549JHZ?
The AD549KHZ is the closest same-family drop-in choice when a tighter input-bias-current and offset-voltage grade is acceptable. It uses the same AD549 architecture and TO-99 footprint, but improves the stated maximum bias current from 250 fA to 100 fA and maximum offset voltage from 1.00 mV to 0.50 mV. Validate supply range, common-mode range, offset drift, and pin numbering in the manufacturer documentation before substitution.
Can OPA128LM replace AD549JHZ in an existing design?
The OPA128LM can be considered as a cross-brand, pin-compatible electrometer-amplifier alternative for designs using an 8-pin TO-99 footprint, subject to a complete electrical review. Published comparison information identifies a maximum bias current of 75 fA and maximum offset voltage of 500 μV for the OPA128. Confirm its supply voltage, common-mode range, offset drift, noise, and exact pin assignment before approving the substitution.
Is AD549JHZ suitable for pH electrodes and electrochemical sensors?
The AD549JHZ is suitable for pH electrodes and electrochemical sensors because its 250 fA maximum input bias current minimizes the error introduced by extremely high source impedances. Its guaranteed input-bias behavior over the common-mode range and laser-trimmed offset voltage support accurate DC measurements. The complete sensor system should still be evaluated for leakage, guard-ring construction, noise, settling time, and electrode input capacitance.
Where can I buy AD549JHZ online?
Use the Request a Quote form on this page to request AD549JHZ availability, current lead time, and commercial terms. The manufacturer offers the AD549 in a hermetic TO-99 package, and the exact AD549JHZ ordering code should be retained for traceability. Share the target quantity and required delivery location with the supplier so the quote reflects the correct order configuration.
What is the price of AD549JHZ?
The current commercial price for AD549JHZ is handled through the Request a Quote form on this page. The form allows the quantity and currency context to be specified without publishing a stale figure. For comparison purposes, AD549JHZ is a single-channel precision amplifier in a hermetic TO-99-8 package, so request a quote for the exact ordering code rather than a generic AD549 variant.
What is the lead time for AD549JHZ?
Request the current AD549JHZ lead time and available quantity through the Request a Quote form on this page. Lead time can vary with order volume, package configuration, and inventory status, so it should be confirmed for the exact AD549JHZ ordering code. If production continuity matters, include the intended annual usage and requested delivery schedule in the inquiry.
Is AD549JHZ in stock?
AD549JHZ availability should be confirmed through the Request a Quote form on this page. Enter the required quantity and, when applicable, the production schedule so the supplier can return current stock and lead-time information for the exact MPN. A distributor listing indicates that the part is marketed, but only a current quotation establishes the supply position for a particular order.
What design considerations matter for an AD549JHZ high-impedance measurement circuit?
An AD549JHZ measurement circuit should minimize leakage into the input node and account for its 1 MHz gain-bandwidth product when setting signal bandwidth. Use guarded traces, clean connectors, suitable insulation, and leakage-resistant PCB materials. Also verify input capacitance, noise, output swing, and feedback-network stability, because a 250 fA bias-current specification alone does not guarantee complete sensor-system accuracy.
Is AD549JHZ RoHS compliant and qualified for automotive use?
The AD549JHZ is an industrial or instrumentation-focused electrometer operational amplifier, but its RoHS, REACH, and AEC-Q100 status should be confirmed from the current Analog Devices product documentation. The verified manufacturer material identifies the hermetic TO-99 package and precision electrical characteristics but does not provide a complete current compliance declaration. Use the product page and the relevant declaration for production release.

Mühendislik referans verileri: AD549JHZ — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.

Seçim Kılavuzu

Choose the AD549JHZ when a single-channel electrometer amplifier with a 250 fA maximum input bias current is sufficient and the 1.00 mV maximum offset voltage meets the measurement budget. Select the AD549KHZ when 100 fA and 0.50 mV limits justify the tighter K grade, or the AD549LHZ when the 60 fA AD549L grade is needed for picoamp-scale current measurements. The AD549SH/883B may suit screened or grade-specific requirements, but its detailed limits should be checked against the production specification. For a cross-brand option, evaluate the OPA128LM, whose published 75 fA bias-current and 500 μV offset-voltage limits are tighter than those of the J grade. All listed options use the TO-99-8 format, but engineers should still verify supply range, common-mode range, noise, offset drift, stability, and exact pin assignment before replacing AD549JHZ.

Alternatiflerle Karşılaştırma

Parametre Bu Ürün AD549KHZ AD549LHZ AD549SH/883B AD549LH OPA128LM
Package TO-99-8 hermetic package TO-99-8 hermetic package TO-99-8 hermetic package TO-99-8 hermetic package TO-99-8 hermetic package TO-99-8 hermetic package
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Texas Instruments
Application Class Electrometer operational amplifier Electrometer operational amplifier Electrometer operational amplifier Electrometer operational amplifier Electrometer operational amplifier Low-bias-current precision operational amplifier

Ana Farklılayıcılar

  • AD549 family architecture provides a practical precision upgrade path (karşılaştırma:AD549KHZ)
  • The L grade offers the lowest stated AD549 bias-current limit (karşılaştırma:AD549LHZ)
  • The cross-brand OPA128LM provides tighter published offset limits (karşılaştırma:OPA128LM)

Tasarım Notları

Protect the input node from leakage with guarded traces, a guarded input structure, clean connectors, and low-contaminating PCB materials. The AD549JHZ permits 250 fA maximum input bias current, so a contaminated surface, flux residue, or unprotected solder trace can create an error comparable to or larger than the amplifier's specified input current. Keep the high-impedance input away from power-switching nodes, inductors, and grounded copper that could increase parasitic coupling.

Do not treat the 1 MHz gain-bandwidth product as the complete signal-bandwidth specification. The usable closed-loop bandwidth also depends on noise gain, feedback resistance, source capacitance, and the selected compensation network. Check settling time against the 3 V/μs slew rate and account for the 15 μV/°C maximum input-offset drift when defining the measurement accuracy over temperature.

Use the manufacturer's TO-99 pin-description table when assigning PCB holes and keep sensitive input traces short and appropriately guarded. Bypass power pins with the recommended local capacitance and route supply current away from the input node. Because the AD549JHZ is intended for high-impedance measurements, layout leakage and contamination may dominate the error budget even when the amplifier itself is precision trimmed.

Operate the AD549JHZ within its specified ±5 V to ±18 V supply range and verify output swing across the full signal range. For bipolar operation, ensure both supply rails are stable and referenced correctly. Use local decoupling to prevent supply disturbances from modulating the measured node, and account for the amplifier's quiescent and output-current behavior when sizing the supply for the selected feedback network.

Uyumluluk Bilgisi

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Kadmiyumdan Arınmış
Unknown
Klorofillerden Arınmış
Unknown
Çatışma Minerali
Unknown

The current manufacturer product page and datasheet identify the AD549 as a precision electrometer operational amplifier in a hermetic TO-99 package. A complete current RoHS, REACH, lead-free, halogen-free, and conflict-minerals declaration was not identified in the retrieved material; AEC-Q100 automotive qualification is not indicated for the standard AD549JHZ grade.

Veri doğrulanma tarihi: 2026-11-25 — XAIPART bileşen mühendislik ekibi tarafından doğrulanmış ve derlenmiş veri

İlgili Aramalar

ad549jhz datasheet AD549JHZ datasheet pdf AD549JHZ TO-99-8 pinout AD549JHZ 250 fA input bias current AD549JHZ electrometer operational amplifier Analog Devices AD549JHZ AD549JHZ drop-in replacement AD549JHZ vs AD549KHZ AD549JHZ vs OPA128LM AD549JHZ price AD549JHZ stock AD549JHZ pH electrode amplifier AD549JHZ photodiode transimpedance AD549JHZ application circuit what can replace AD549JHZ

İlgili Bileşenler ve Terimler

Analog Devices AD549 AD549JHZ AD549KHZ AD549LHZ AD549SH/883B AD549LH OPA128LM Texas Instruments electrometer operational amplifier precision operational amplifier analog signal-chain IC Topgate JFET JFET TO-99-8 hermetic package TO-99 package through-hole package input bias current input offset voltage input offset voltage drift gain-bandwidth product slew rate transimpedance amplifier pH electrode electrochemical sensor
Hızlı Teklif RFQ
Detayları tam doldurun — satış ekibimiz 24 saat içinde yanıt verecek
Parça Numarası Üretici Paket QTY Hedef Fiyat Genişletilmiş
✓
Teklif gönderildi!

24 saat içinde e-postanıza yanıt vereceğiz

1
RFQ Gönderildi
2
Teklif Alındı
3
Sipariş Yerleştirildi
4
Ödeme
5
Gönderildi
6
Teslim Edildi
RFQ Detaylarını Görüntüle