AD549LHZ - Electrometer Op Amp with Low Input Bias | Analog Devices
MPN: AD549LHZ ✓ Hoạt độngAD549LHZ Tóm tắt
An electrometer operational amplifier is a specialized type of operational amplifier optimized for exceptionally low input bias current. Within the signal-chain hierarchy, it provides the gain and input buffering required by high-impedance sensors, charge-measurement circuits, photodetectors, and laboratory instrumentation. Unlike a general-purpose operational amplifier, an electrometer amplifier minimizes current entering its input terminals so that source impedance and leakage effects remain small relative to the measured signal.
The AD549 family combines low input current with precision DC characteristics. Analog Devices identifies Topgate JFET technology as the process responsible for the ultralow input current, while laser trimming of input offset voltage and offset-voltage drift improves precision at the factory level. The result is an amplifier suited to applications where current leakage, offset error, or temperature-dependent drift can obscure a small sensor signal. The LHZ ordering code identifies the 8-pin TO-99 package configuration.
At the circuit level, the AD549LHZ operates as a conventional precision operational amplifier with feedback-defined gain. Its low input current is especially important when the source is a photodiode, ionization chamber, electrochemical sensor, or other high-impedance transducer. The 1 MHz gain-bandwidth product permits useful signal bandwidth, although noise, input capacitance, stability, and output-drive conditions still determine the practical operating bandwidth. Bypass capacitors and careful guarding around sensitive input nodes are therefore more important than treating the wide bandwidth as a reason to omit layout discipline.
Typical uses include pH and ion-selective measurement, photovoltaic and radiation-detection instrumentation, charge-sensitive preamplifiers, low-current sensors, laboratory amplifiers, and precision bridge front ends. In these systems, the amplifier converts a weak current or high-impedance voltage into a usable analog signal while introducing less input-current error than a conventional amplifier. The metal-can package also supports applications where through-hole assembly and a stable industrial component format are preferred.
Designers should evaluate leakage, guarding, connector cleanliness, board contamination, and the bias current flowing through feedback resistors. A practical rule is to keep the highest-impedance node physically small, avoid exposed conductors near the inputs, and route guard structures where appropriate. The amplifier, its resistor network, and the sensor interface should also be checked for temperature gradients because those factors can dominate the final measurement uncertainty.
This page combines the AD549 architecture, package information, replacement analysis, and application guidance into an engineering-focused selection resource. It highlights where the AD549LHZ is appropriate, which same-package alternatives may fit different precision or qualification requirements, and which layout and sourcing details should be confirmed before production release.
Bộ thay thế dễ dàng lắp đặt cho AD549LHZ — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với AD549LHZ (cùng hình factor và footprint) — khác nhau ở Package Type, Slew Rate, Amplifier Type, Mounting Type, Number of Channels.
AD549JHZ
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →AD549JH
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →AD549SH/883B
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
OPA128KM
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
AD549LHZ Tỷ lệ tối đa & tính chất điện
| Product Type | Single-circuit electrometer operational amplifier |
| Input Device Technology | Topgate JFET |
| Gain-Bandwidth Product | 1 MHz |
| Number of Circuits | 1 circuit |
| Amplifier Type | Electrometer operational amplifier |
| Hộp | TO-99-8 metal can |
| Số lượng chân | 8 pins |
| Kiểu lắp đặt | Through-hole |
Cấu hình chân AD549LHZ
| Chân 1 | NC — Not connected |
| Chân 2 | IN- — Inverting input |
| Chân 3 | IN+ — Non-inverting input |
| Chân 4 | V- — Negative supply |
| Chân 5 | NC — Not connected |
| Chân 6 | OUT — Output |
| Chân 7 | V+ — Positive supply |
| Chân 8 | NC — Not connected |
Ứng dụng tiêu biểu
AD549LHZ phù hợp cho 6 Áp dụngs: Photodiode Signal Conditioning, pH and Ion-Selective Measurement, Ionization Chamber Readout, Electrochemical Sensor Interface, Low-Current Charge Amplifier, Precision Laboratory Instrumentation.
Photodiode Signal Conditioning
The AD549LHZ is appropriate for converting photodiode current into a voltage because its very low input bias current reduces the error introduced at the high-impedance input. It can be configured with a feedback resistor and optional capacitor to provide useful conversion gain and bandwidth. The 1 MHz gain-bandwidth product provides bandwidth for many optical-sensing systems, although the exact response depends on photodiode capacitance and feedback impedance. Keep the input trace short, protect it from contamination, and use guarding where leakage could affect the measurement.
Được đề xuất
pH and Ion-Selective Measurement
The AD549LHZ suits pH and ion-selective sensor interfaces because chemical electrodes present extremely high source impedance, where input bias current can create a substantial error voltage. Its laser-trimmed offset characteristics support precision measurement, while the Topgate JFET input stage minimizes current drawn from the sensing electrode. The amplifier should be positioned near the sensor connector, with short input traces, clean insulation, and guarded interconnects. Supply decoupling and grounding must be designed to avoid adding noise directly to the high-impedance measurement node.
Được đề xuất
Ionization Chamber Readout
The AD549LHZ can serve as the first active element in an ionization-chamber or radiation-detector readout because very low input current preserves the small charge signal generated by the detector. Its 1 MHz gain-bandwidth product is sufficient for many charge-sensitive front ends when combined with an appropriate feedback network, but stray capacitance and feedback-resistor noise set practical sensitivity. The TO-99-8 metal can supports through-hole assembly in laboratory and industrial instruments. Guard the input and use low-leakage insulation around connectors and nearby surfaces.
Được đề xuất
Electrochemical Sensor Interface
The AD549LHZ is well matched to electrochemical sensors whose output may be represented as a very small current. Its low input bias current limits the error introduced by high-impedance transducers, while laser trimming improves the amplifier’s DC precision. In a typical transimpedance arrangement, the feedback resistor establishes current-to-voltage conversion and the amplifier supplies a buffered output for an ADC or controller. Select resistor values with both Johnson noise and leakage in mind, and avoid placing moisture, flux residue, or conductive contamination near the input node.
Được đề xuất
Low-Current Charge Amplifier
The AD549LHZ can be used in charge-sensitive and capacitive-sensor front ends where the input current is intentionally very small. The amplifier’s electrometer-grade input stage reduces the current drawn from the sensitive node, while its 1 MHz gain-bandwidth product allows the closed-loop response to be tailored with feedback components. Practical performance remains sensitive to input capacitance, feedback capacitor selection, board leakage, and the stability of the chosen noise gain. Use a short, guarded input route and avoid excessive bandwidth when it would amplify unwanted noise.
Được đề xuất
Precision Laboratory Instrumentation
The AD549LHZ is appropriate for precision laboratory instruments that measure high-impedance sources, leakage currents, or small sensor voltages. Its laser-trimmed input offset voltage and offset-voltage drift support repeatable bench measurements, while the TO-99-8 package offers a familiar through-hole mechanical format for custom analog boards. A practical implementation should isolate sensitive input wiring from power converters and motors, maintain stable grounding, and include provisions for input biasing or guarding. Confirm supply limits and electrical characteristics in the manufacturer datasheet before selecting operating points.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho AD549LHZ — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | AD549JHZ | AD549JH | AD549SH/883B | OPA128KM |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Package | TO-99-8 | TO-99-8 - same package | TO-99-8 - same package | TO-99-8 - same package | TO-99-8 - same package |
| Product Type | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Low-input-current precision operational amplifier |
| Circuit Count | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
| Mounting Style | Through-hole metal can | Through-hole | Through-hole | Through-hole | Through-hole |
Bảo phân biệt quan trọng
- Tighter precision trimming than AD549JHZ (vsAD549JHZ)
- Direct AD549-family continuity (vsAD549SH/883B)
- Established same-package precision alternative (vsOPA128KM)
Ghi chú thiết kế
Route the inverting input directly to the feedback resistor and minimize the area of the high-impedance node. Keep connectors, solder mask, and board surfaces clean and dry because contamination can create leakage paths that exceed the AD549LHZ input-current capability. Where practical, surround sensitive input routing with a guard driven by the amplifier’s inverting-input potential.
Do not assume that a low input bias current makes every leakage mechanism negligible. Connector insulation, flux residue, moisture, and contaminated PCB surfaces can produce errors in high-impedance circuits. Use suitable cleaning practices, low-leakage connectors, and a protective enclosure when the measurement environment is humid or dusty. Also confirm the exact pinout and null-terminal treatment in the manufacturer datasheet.
The 1 MHz gain-bandwidth product does not guarantee 1 MHz of useful signal bandwidth in every circuit. Source capacitance, feedback impedance, closed-loop noise gain, slew rate, and output loading influence stability and response. Start with conservative noise gain, evaluate the complete sensor-and-amplifier model, and add compensation components only after confirming the required phase margin.
Thông tin tuân thủ
No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status was identified for the exact AD549LHZ ordering code.