ADS8345N/1K - 16-Bit 8-Ch SAR ADC, 100kHz, 2.7-5V | Texas Instruments
MPN: ADS8345N/1K ✓ Hoạt độngADS8345N/1K Tóm tắt
An ADC is a data converter that transforms a continuous time-varying analog voltage into a numeric code for further digital processing. The ADS8345 family belongs to the SAR converter class, whose internal sample-and-hold front end and successive-approximation conversion core are well suited to medium-speed, high-resolution measurement. Within the signal-chain hierarchy, this part sits between sensors and signal conditioning on the analog side and microcontrollers, DSPs or FPGAs on the digital side, making it a bridge device in a complete data-acquisition chain.
Key features of the ADS8345N/1K include a bipolar input range, an on-board 8:1 analog multiplexer, single-supply operation from 2.7 V to 5 V, and a pin-for-pin compatible footprint with the ADS7844 and ADS8344. The manufacturer datasheet specifies a typical power dissipation of 8 mW at a 100 kHz throughput rate with a +5 V supply, and a shutdown mode that further reduces consumption. The reference voltage VREF can be varied between 500 mV and VCC/2, scaling the usable input range accordingly.
Technically the device combines an 8-channel multiplexer, a sample-and-hold amplifier and a 16-bit SAR core clocked from an external serial interface. The synchronous serial protocol drives conversion start, data readout, and the transfer of the 16-bit result, so one clock line, one data-in line, one data-out line and one chip-select line replace a parallel bus. The result is a compact, low-power converter suitable for multi-channel acquisition where parallel data buses would consume too many microcontroller pins. The SSOP-20 gull-wing package is surface mount and rated over the -40 C to +85 C industrial temperature range.
Typical uses include multichannel industrial data acquisition, test and measurement equipment, industrial process control monitoring, isolated remote data acquisition over long serial runs, portable battery-powered data loggers, and low-level sensor front ends where 16-bit resolution over eight channels is required without a parallel interface.
When designing with the ADS8345N/1K, budget the reference network carefully: because the input range scales with VREF, reference decoupling and the multiplexed settling time determine whether adjacent channels can be sampled back-to-back at the full 100 kHz rate. Keep the reference and analog ground planes clean, and use the shutdown pin to cut supply current in low-duty-cycle battery systems.
Bộ thay thế dễ dàng lắp đặt cho ADS8345N/1K — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với ADS8345N/1K (cùng hình factor và footprint) — khác nhau ở Input Type, Typical Power Dissipation, Reference Voltage Range, Architecture, Mounting Type.
ADS8345N
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →ADS8344N
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →ADS7844N
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →ADS8345NB
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →LTC1290CISW#PBF
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
LTC1290CCSW#PBF
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
MAX147ACAP+
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
ADS8345N/1K Tỷ lệ tối đa & tính chất điện
| Độ phân giải | 16 bit |
| Tỷ lệ lấy mẫu | 100 kHz |
| Number of Analog Input Channels | 8 single-ended / 4 differential |
| Input Type | Bipolar, multiplexed single-ended or differential |
| Architecture | Successive approximation (SAR) |
| Supply Voltage Range | 2.7 V to 5 V (single supply) |
| Nominal Supply Voltage | 2.7 V |
| SINAD | 85 dB |
| Max Linearity Error | 0.0122 % |
| Reference Voltage Range | 500 mV to VCC/2 |
| Giao diện | Synchronous serial (CS, DIN, SCLK, DOUT) |
| Typical Power Dissipation | 8 mW at 100 kHz throughput, +5 V supply |
| Khoảng nhiệt độ hoạt động | -40 C to +85 C |
| Temperature Grade | Industrial |
| Hộp | SSOP-20 (gull wing, 20 terminals) |
| Kiểu lắp đặt | Surface Mount |
| Number of Terminals | 20 |
| Trạng thái RoHS | Compliant |
| Pin Compatibility | Pin-for-pin compatible with ADS7844 and ADS8344 |
Cấu hình chân ADS8345N/1K
| Chân 1 | CS — Active-low chip select for the serial interface |
| Chân 2 | DIN — Serial data input for control words and conversion start |
| Chân 3 | SCLK — Serial clock input |
| Chân 4 | DOUT — Serial data output, conversion result MSB first |
| Chân 5 | DGND — Digital ground |
| Chân 6 | AGND — Analog ground, reference return |
| Chân 7 | AIN0 — Analog input channel 0 |
| Chân 8 | AIN1 — Analog input channel 1 |
| Chân 9 | AIN2 — Analog input channel 2 |
| Chân 10 | AIN3 — Analog input channel 3 |
| Chân 11 | AIN4 — Analog input channel 4 |
| Chân 12 | AIN5 — Analog input channel 5 |
| Chân 13 | AIN6 — Analog input channel 6 |
| Chân 14 | AIN7 — Analog input channel 7 |
| Chân 15 | REFP — Positive reference input |
| Chân 16 | REFN — Negative reference input |
| Chân 17 | VREF — External reference voltage input, 500 mV to VCC/2 |
| Chân 18 | VCC — Analog supply voltage, 2.7 V to 5 V |
| Chân 19 | AGND — Analog ground for the reference and input stage |
| Chân 20 | DGND — Digital ground for the serial interface |
Ứng dụng tiêu biểu
ADS8345N/1K phù hợp cho 6 Áp dụngs: Industrial multichannel data acquisition, Test and measurement equipment, Battery-powered portable data loggers, Isolated remote data acquisition, Industrial process control monitoring, Sensor and IoT node signal acquisition.
Industrial multichannel data acquisition
The ADS8345N/1K fits plant-floor data loggers because its 8:1 analog multiplexer replaces eight separate converter packages and its 100 kHz conversion rate covers process signals that change on a millisecond scale. Sixteen-bit resolution over a bipolar range keeps thermocouple- and bridge-level signals accurate without an instrumentation amplifier, while the synchronous serial interface needs only CS, DIN, SCLK and DOUT lines on the host microcontroller. Typical dissipation of 8 mW at full throughput means a bank of channels can be powered from an isolated 24 V rail without thermal concerns. Use external anti-alias filtering ahead of each analog input and keep the reference node quiet with dedicated decoupling.
Được đề xuất
Test and measurement equipment
In bench instruments such as oscilloscope-like measurement front ends and automated test systems, the ADS8345N/1K converts eight simultaneous front-panel or fixture channels through one converter, so the instrument keeps a single serial bus instead of eight parallel data paths. With 85 dB SINAD and 0.0122% maximum linearity error, the 16-bit code supports calibrated measurements without pushing the burden of accuracy onto analog compensation networks. The shutdown mode is useful in two-stage instruments where a fast measurement must be followed by a long standby period. Place the converter close to the input connectors to minimize noise pickup ahead of the sampling capacitor.
Được đề xuất
Battery-powered portable data loggers
Portable field loggers benefit from the ADS8345N/1K because the whole measurement chain draws only about 8 mW at the full 100 kHz conversion rate, and the shutdown mode lets the logger sleep between acquisition bursts. Eight bipolar channels cover thermocouple, ratiometric bridge and pressure-transducer inputs without adding converters to a size-constrained enclosure, and the serial interface keeps the pin count low on small mixed-signal microcontrollers. Because VREF scales the input range, select a reference close to the sensor's full-scale span to use most of the 16-bit code. Add a hold capacitor per slow channel if the sensor output impedance is high.
Được đề xuất
Isolated remote data acquisition
The ADS8345N/1K supports long serial runs because the synchronous serial protocol transmits the 16-bit result over a single clocked data line plus chip select, which can be extended across a galvanic isolation barrier with digital isolators. This makes it practical to place eight analog channels far from the host controller in a remote cabinet while keeping conversion accuracy intact. Keep the serial clock rate below the isolator's maximum and route the ground reference so the isolation barrier does not carry analog current. In a multi-node installation, the chip-select line can be used to daisy-chain converters onto one bus.
Được đề xuất
Industrial process control monitoring
Process monitoring loops that sample pressure, level and flow transmitters every few milliseconds are well matched to the ADS8345N/1K, whose 100 kHz rate gives substantial headroom over the sampling interval and whose 16-bit resolution resolves transmitter outputs across a bipolar 4-20 mA conditioned signal. The single 2.7 V to 5 V supply lets the converter run from the same rail as modern industrial microcontrollers, and the -40 C to +85 C grade covers unheated enclosures. Because the multiplexer scans channels in sequence, give each input enough acquisition time for its RC network to settle, and route the reference plane separately from the analog inputs to avoid crosstalk between adjacent channels.
Được đề xuất
Sensor and IoT node signal acquisition
Compact IoT sensor nodes that must read several slow-changing analog quantities benefit from the ADS8345N/1K because one 20-pin package covers eight channels instead of eight separate converters, keeping both board area and BOM cost down. With the shutdown pin asserted between polls, a duty-cycled node can keep average consumption very low while still waking to take a 16-bit reading on each channel. The synchronous serial interface runs comfortably from a low-cost microcontroller, and the bipolar range directly accepts ratiometric sensor bridges referenced to the same supply. Set VREF from 500 mV to VCC/2 to match the sensor span and maximise usable codes.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho ADS8345N/1K — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | ADS8344N | ADS7844N | LTC1290CISW#PBF | MAX147ACAP+ |
|---|---|---|---|---|---|
| Package | SSOP-20 | SSOP-20 - same | SSOP-20 - same | SSOP-20 - same | SSOP-20 - same |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices | Analog Devices |
| Resolution | 16 bit | 16 bit | 12 bit | 14 bit | 13 bit |
| Input Channels | 8 single-ended / 4 differential | 8 single-ended / 4 differential | 8 single-ended / 4 differential | 8 single-ended / 4 differential | 8 single-ended / 4 differential |
| Input Range | Bipolar, +/-VREF | Unipolar, 0 V to VREF | Unipolar, 0 V to VREF | Unipolar, 0 V to VREF | Unipolar, 0 V to VREF |
| Interface | Synchronous serial (CS, DIN, SCLK, DOUT) | Synchronous serial - same | Synchronous serial - same | Serial output, similar framing | Serial output, similar framing |
Bảo phân biệt quan trọng
- Bipolar input range with a programmable reference (vsADS8344N)
- Four extra bits of resolution in the same footprint (vsADS7844N)
- Higher accuracy than 14-bit and 13-bit SSOP-20 substitutes (vsLTC1290CISW#PBF)
Ghi chú thiết kế
Decouple the analog supply close to the VCC pin with a 0.1 uF ceramic plus a 1 uF or larger bulk capacitor, and connect the digital and analog grounds with a single short link near the package. The reference network should have its own 0.1 uF bypass capacitor between REFP and REFN. Estimated: with 5 V supply, 100 kHz throughput and 8 mW typical dissipation from the datasheet, the converter contributes roughly 1.6 mA of average supply current, which is small but still enough to shift a shared reference node if it is poorly decoupled.
The biggest pitfall is forgetting that the input range follows VREF. If VREF is set to 2.5 V on a 5 V supply, the converter accepts only plus or minus 2.5 V and any signal beyond that saturates, so scale the input accordingly. A second pitfall is assuming the ADS7844, ADS8344 and ADS8345 are interchangeable in behaviour: the ADS7844 offers 12-bit resolution and the ADS8344 has unipolar inputs, so a board migrated from ADS7844 to ADS8345N/1K changes both code width and input polarity handling. Third, confirm the serial clock and chip-select timing against the datasheet timing diagrams before running the bus above the specified clock frequency.
Route the eight analog inputs as short, quiet traces on a single analog plane, and keep the digital SCLK, DIN, DOUT and CS lines away from the analog inputs to avoid coupling the clock edge into the sampling capacitor. Place the converter close to the input connectors or sensor interface so that the settling time between the multiplexer switch and the sample-and-hold acquisition is sufficient at the full 100 kHz rate. Provide a separate return path for the reference current rather than sharing the analog ground path with high-current digital return.
Thông tin tuân thủ
RoHS compliant as listed by Texas Instruments for the ADS8345 family. The device is graded for industrial temperatures (-40 C to +85 C) and is not AEC-Q100 qualified, so automotive designs should confirm requirements separately.