INA117KUG4 - ±200V Difference Amplifier | Texas Instruments
MPN: INA117KUG4 ✓ Hoạt độngINA117KUG4 Tóm tắt
A difference amplifier is an amplifier category that rejects a voltage common to both inputs and amplifies the voltage difference between them. The INA117 belongs to the precision instrumentation-amplifier hierarchy, combining a precision operational amplifier with an integrated thin-film resistor network. Its monolithic construction provides a fixed unity gain and eliminates the gain-setting resistors normally required around a conventional difference amplifier.
The principal feature is the INA117's high common-mode voltage range of ±200V. It can therefore sense a small differential voltage across high-side, low-side, or floating conductors without requiring the signal itself to remain close to ground. Other stated characteristics include 1 mV input offset voltage, 1.5 mA supply current, and operation from ±5V to ±18V dual supplies. The device also includes input protection for momentary input-voltage excursions.
Internally, the INA117 combines a precision op amp with matched thin-film resistors in one monolithic IC. This arrangement supports a unity gain of 1 dB, predictable differential response, and rejection of common-mode signals without external matched resistor networks. Its 200 kHz bandwidth is sufficient for many measurement and control loops, although the 2.6 V/µs slew rate means it should not be treated as a wide-band, high-speed instrumentation amplifier.
Typical uses include measuring small voltage drops across high-current shunts, detecting current in power-conversion systems, monitoring high-side sensor signals, and building isolated or floating measurement front ends. The device is also appropriate for laboratory and industrial equipment where a measurement input may exceed ordinary op-amp input ranges by a wide margin.
Designers should verify supply polarity, input-versus-supply limits, and the permitted instantaneous input voltage before connecting a high-energy circuit. The output reference determines the output voltage corresponding to zero differential input, so reference-ground and output-signal routing should be planned carefully. Because common-mode range does not eliminate all safety concerns, upstream resistors, clamps, or isolation may still be required.
This page combines the manufacturer's core specifications, orderable-package information, drop-in alternatives, comparison parameters, and practical design guidance to support faster component selection and PCB implementation.
Bộ thay thế dễ dàng lắp đặt cho INA117KUG4 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với INA117KUG4 (cùng hình factor và footprint) — khác nhau ở Operating Temperature Range, Package, Input Protection, Gain, RoHS Status.
INA117KU
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA149N
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →AD629ARZ-R7
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →AD8479
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
INA146UA
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA117KUG4 Tỷ lệ tối đa & tính chất điện
| Amplifier Type | Precision unity-gain difference amplifier |
| Number of Amplifiers | 1 circuit |
| Common-Mode Input Voltage Range | ±200 V |
| Input Offset Voltage | 1 mV |
| Maximum Gain | 1 dB |
| Gain | 1 unity |
| Bandwidth | 200 kHz |
| Slew Rate | 2.6 V/µs |
| Supply Voltage Range | ±5 V to ±18 V |
| Điện áp cung cấp | 1.5 mA |
| Khoảng nhiệt độ hoạt động | -40 °C to 85 °C |
| Hộp | 8-pin SOIC |
| Terminal Count | 8 terminals |
| Kiểu lắp đặt | Surface mount |
| Temperature Grade | Industrial |
| Internal Resistor Network | Thin-film resistor network |
| Input Protection | Protected against momentary input-voltage excursions |
| Trạng thái RoHS | Compliant |
| Trạng thái vòng đời | Active |
| Manufacturer Document Page Count | 17 pages |
Hướng dẫn cấu hình chân INA117KUG4 8-pin soic
Cấu hình chân cho INA117KUG4 (8-pin soic gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho INA117KUG4.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
INA117KUG4 phù hợp cho 6 Áp dụngs: High-Side Shunt Current Sensing, Power-Module Output Monitoring, Industrial Sensor Front End, High-Voltage Battery Monitoring, Laboratory Instrumentation, Motor Drive Feedback.
High-Side Shunt Current Sensing
The INA117KUG4 fits high-side shunt sensing when a small differential voltage appears across a current shunt while the shunt sits at a substantially higher common-mode voltage. Its ±200V common-mode range permits sensing without bringing the input close to ground, and its 1 mV input offset establishes the baseline accuracy relevant to millivolt-scale shunt drops. Place the amplifier across the shunt, provide ±5V to ±18V supplies, and route the output into an ADC or control comparator. Check the source-to-input protection limits and add series resistance or clamps where the bus can experience fast transients.
Được đề xuất
Power-Module Output Monitoring
INA117KUG4 can monitor a small output-voltage change across a high-current power module while the module's terminal voltage is far above system logic levels. The ±200V common-mode capability protects the measurement concept from ordinary rail voltages, while the 200 kHz bandwidth supports feedback loops and supervisory circuitry that do not require high-speed transient capture. Use the amplifier in unity-gain configuration across the relevant sense points and reference its output to the midpoint established by the REF connection. Validate saturation, output swing, and common-mode behavior across startup, shutdown, and full load conditions.
Được đề xuất
Industrial Sensor Front End
The INA117KUG4 is suitable for industrial sensor interfaces in which a weak differential signal is superimposed on a high common-mode potential. Its fixed unity gain simplifies signal-path design, while the integrated thin-film resistor network avoids matching four external precision resistors around a conventional difference amplifier. The 1 mV input offset and 1.5 mA supply current support low-power instrumentation, and the industrial temperature specification covers -40 °C to 85 °C. Because sensor wiring can introduce ground differences and transients, use protected routing and verify that the sensor output remains within the amplifier's allowable common-mode and supply limits.
Được đề xuất
High-Voltage Battery Monitoring
INA117KUG4 can support high-voltage battery-pack monitoring when each measurement point shares a high common-mode voltage relative to the measurement electronics. The ±200V common-mode range is relevant to pack-level sensing, and unity-gain differential measurement rejects much of the voltage common to the two taps. The 200 kHz bandwidth is appropriate for slow balancing and supervisory functions rather than fast pulse-current analysis. Verify the maximum instantaneous input voltage, supply arrangement, and output operating range against the battery system's worst case, and provide protection against load dump or switching transients.
Được đề xuất
Laboratory Instrumentation
INA117KUG4 fits laboratory measurement equipment that must observe a small differential signal riding on a large common-mode voltage. The unity-gain architecture produces a direct differential measurement, while the integrated precision network improves repeatability compared with an unmatched discrete implementation. Its 200 kHz bandwidth handles many general-purpose instrument signals but not high-frequency waveform analysis. For instrument-grade results, verify input bias effects, output-noise behavior, settling time, and reference accuracy using the manufacturer test conditions. A shielded PCB layout and quiet reference return are especially important when resolving millivolt-level signals.
Được đề xuất
Motor Drive Feedback
INA117KUG4 can measure motor-drive feedback signals when the shunt or sensing network introduces a small differential voltage on a switching or elevated common-mode node. The ±200V common-mode range offers substantial headroom for bus-related measurement, while the 2.6 V/µs slew rate and 200 kHz bandwidth are appropriate for many current-control loops. Place the inputs close to the shunt and keep them away from switching-node copper to limit capacitive coupling. Validate the amplifier against the drive's switching edges, overshoot, and operating-temperature range, since common-mode rating alone does not guarantee immunity to high dv/dt events.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho INA117KUG4 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | INA117KU | INA149 | AD629 | AD8479 | INA146UA |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices | Analog Devices | Texas Instruments |
| Package | SOIC-8 | SOIC-8 | SOIC-8 | SOIC-8 | SOIC-8 | SOIC-8 |
| Amplifier Type | Precision unity-gain difference amplifier | Precision unity-gain difference amplifier | High-common-mode difference amplifier | High-voltage difference amplifier | Difference amplifier | Difference amplifier |
Bảo phân biệt quan trọng
- Very high common-mode measurement range (vsAD629)
- Fixed unity gain with integrated thin-film network (vsINA146UA)
- Direct high-side shunt sensing capability (vsAD8479)
- Low 1.5 mA supply current (vsINA149)
Ghi chú thiết kế
The INA117KUG4 requires both positive and negative supply rails in the stated operating configuration of ±5V to ±18V. Confirm the output swing at the selected supply voltage and load before using the device with a zero-centered input. The REF terminal establishes the output level for zero differential input; connect it to a low-impedance reference appropriate to the ADC or control system rather than allowing it to float.
A ±200V common-mode rating does not mean the device can safely tolerate ±200V continuously under every fault condition. Review the absolute-maximum input voltage, momentary input-protection behavior, and supply limits in the manufacturer datasheet. Add input series resistance and suitable clamping where the measured node can experience load dump, inductive kick, or other energy outside normal operating limits.
Route the two differential inputs as a compact pair directly from the shunt or sensing nodes, with minimal loop area and no switching-node copper beneath them. Keep the reference and output traces away from high-current return paths to prevent coupling. Because the device is designed around a thin-film resistor network and precision input offset, asymmetric routing and ground-potential differences can degrade the measured differential signal.
The 200 kHz bandwidth is adequate for many measurement loops but not for arbitrary high-frequency transients. Establish an anti-aliasing filter appropriate to the intended signal bandwidth and use the 2.6 V/µs slew rate to check output-moving requirements. For fast-switching systems, measure input-to-output response and common-mode behavior on the actual PCB because parasitic capacitance can introduce errors that are not apparent from the low-frequency gain specification.
Thông tin tuân thủ
RoHS-compliant status is stated in the orderable-product information. The industrial-temperature INA117KUG4 is not identified as an AEC-Q100-qualified automotive device. No separate REACH, halogen-free, or conflict-minerals declaration is stated.