INA125TDA2 - 10000:1 Instrumentation Amplifier | Texas Instruments
MPN: INA125TDA2 ✓ Hoạt độngINA125TDA2 Tóm tắt
An instrumentation amplifier is a precision analog amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal architecture is designed to provide high input impedance, controlled differential gain, and strong rejection of common-mode interference. This makes instrumentation amplifiers distinct from general-purpose operational amplifiers and places them within the amplifier IC hierarchy used for sensor conditioning, bridge excitation, and high-precision signal acquisition.
Key characteristics include a maximum voltage gain of 10000, minimum common-mode rejection ratio of 107 dB, nominal bandwidth of 0.15 MHz, and maximum nonlinearity of 0.004%. The integrated precision voltage reference supports applications that need a controlled reference in addition to differential amplification. The single-circuit implementation also reduces the number of separate amplifiers needed for one measurement channel.
The INA125 architecture supports programmable gain through external components and is suited to analog front ends where signal gain must be selected according to sensor output and input range. Its high common-mode rejection is valuable when a low-level sensor signal is measured in the presence of system-level interference. Because the INA125TDA2 is supplied as bare die, final package options, pin assignments, bonding details, and production integration requirements must be confirmed directly with Texas Instruments before a PCB or multichip-module design is released.
Typical applications include bridge-based pressure and force measurement, precision current sensing, laboratory instrumentation, industrial sensor interfaces, and medical monitoring circuits. In a bridge circuit, the device can amplify the small differential bridge voltage while rejecting much of the common excitation voltage and its associated noise. The integrated reference can also support excitation or signal-conditioning systems that require a stable, controlled reference.
The most important design consideration is package integration because INA125TDA2 is a die rather than a standard molded package. Designers should obtain the manufacturer’s die-product documentation and bonding information before assigning pads, defining the footprint, or estimating assembly yield. Input filtering, reference bypassing, gain-setting resistors, and output settling should also be evaluated against the selected gain and measurement bandwidth.
This page combines the identified electrical characteristics with application guidance, design considerations, sourcing information, and a transparent assessment of replacement options. The absence of confirmed pin-to-pin alternatives is itself important because a functionally similar amplifier in a different package is not a drop-in replacement.
Bộ thay thế dễ dàng lắp đặt cho INA125TDA2 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Không có bộ thay thế dễ dàng lắp đặt sẵn có cho sản phẩm này.
Yêu cầu các bộ thay thếINA125TDA2 Tỷ lệ tối đa & tính chất điện
| Product Type | Instrumentation amplifier with precision voltage reference |
| Amplifier Circuit Count | 1 circuit |
| Maximum Voltage Gain | 10000 |
| Maximum Nonlinearity | 0.004% |
| Minimum Common-Mode Rejection Ratio | 107 dB |
| Nominal Bandwidth | 0.15 MHz |
| Package Form | Rectangular bare die |
| Terminal Count | 17 terminals |
| Terminal Form | No lead |
| Reference | Integrated precision voltage reference |
Hướng dẫn cấu hình chân INA125TDA2 rectangular bare die
Cấu hình chân cho INA125TDA2 (rectangular bare die gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho INA125TDA2.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
INA125TDA2 phù hợp cho 6 Áp dụngs: Bridge-Based Pressure Measurement, Precision Current Sensing, Laboratory Measurement Instrumentation, Industrial Sensor Signal Conditioning, Medical Monitoring Signal Chain, Precision Reference and Gain Stage.
Bridge-Based Pressure Measurement
The INA125TDA2 can condition the small differential output generated by a strain-gauge or resistive bridge while rejecting a much larger common-mode excitation voltage. Its maximum voltage gain of 10000 provides substantial amplification for low-level bridge outputs, and its minimum common-mode rejection ratio of 107 dB helps isolate the differential measurement from common-mode interference. The bare-die format makes this approach most appropriate when the sensor assembly or multichip module requires direct die integration rather than a conventional PCB footprint.
Precision Current Sensing
INA125TDA2 is suitable for amplifying a low-level differential voltage produced by a current shunt, current transformer, or precision sensing element. The 107 dB minimum common-mode rejection ratio is valuable when the sensed voltage is much smaller than the supply or surrounding signal levels, while the 0.15 MHz nominal bandwidth supports measurement channels that do not require high-speed signal capture. System designers should verify the common-mode range and gain-dependent stability before finalizing the analog front end.
Laboratory Measurement Instrumentation
Laboratory front ends often combine adjustable amplification, accurate differential measurement, and a stable reference in a single signal-conditioning channel. The INA125TDA2 combines a maximum gain of 10000, 0.004% maximum nonlinearity, an integrated precision voltage reference, and strong common-mode rejection. Those characteristics make it relevant to bench instruments and precision test systems. Its 17-terminal bare-die construction requires a controlled die-integration process and manufacturer-approved assembly documentation.
Industrial Sensor Signal Conditioning
Industrial sensors can generate small differential outputs while the surrounding process equipment introduces large common-mode voltages. INA125TDA2 can provide the front-end gain, reaching 10000 maximum voltage gain, while its 107 dB minimum common-mode rejection ratio limits the influence of common-mode signals. The integrated precision reference supports controlled measurement-system architectures. Because the device is supplied as bare die, it is best suited to applications that already include qualified die bonding, inspection, and calibration capabilities.
Medical Monitoring Signal Chain
INA125TDA2 may be considered for biomedical monitoring modules in which a small sensor voltage must be separated from a larger common-mode potential before digitization. Its 0.004% maximum nonlinearity supports precision signal conditioning, and its high common-mode rejection ratio helps protect weak sensor signals from common-mode interference. Medical designs must additionally validate input protection, patient isolation, leakage, noise, regulatory requirements, and the complete assembled system rather than relying on the amplifier specifications alone.
Precision Reference and Gain Stage
The integrated precision voltage reference makes INA125TDA2 more than a conventional differential gain stage. A measurement system can use the reference for controlled excitation, calibration, or signal-conditioning support while the amplifier handles a differential input. Its maximum voltage gain of 10000 and 0.15 MHz nominal bandwidth define the useful operating envelope for low-frequency precision measurements. External reference-decoupling and gain-setting components must follow the manufacturer’s recommended application circuit.
Dữ liệu tham khảo kỹ thuật cho INA125TDA2 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này |
|---|---|
| Package | 17-terminal rectangular bare die, no lead |
| Brand | Texas Instruments |
| Product Type | Instrumentation amplifier with precision voltage reference |
| Circuit Count | 1 circuit |
| Maximum Voltage Gain | 10000 |
| Maximum Nonlinearity | 0.004% |
| Minimum Common-Mode Rejection Ratio | 107 dB |
| Nominal Bandwidth | 0.15 MHz |
| Terminal Count | 17 terminals |
| Reference | Integrated precision voltage reference |
Ghi chú thiết kế
Do not create a conventional PCB footprint from the 17-terminal count alone. INA125TDA2 is a bare die, so obtain the manufacturer’s die drawing and terminal map before defining copper, bonding pads, or assembly keepouts. The package library uses a generic diagram only because no public molded-package pinout applies to this ordering configuration.
Treat the reference and gain-setting nodes as sensitive analog nodes. Keep external gain-setting and reference-bypass components close to the device where the die-level assembly permits, and route them away from high-current switching paths. Verify settling and bandwidth at the selected gain because the device’s nominal bandwidth is 0.15 MHz and its usable bandwidth can vary with gain.
A similar instrumentation amplifier in a molded package is not a drop-in replacement for INA125TDA2. Package migration changes the mechanical footprint, assembly process, thermal behavior, and possibly the available ordering configuration. Select a substitute only after comparing the complete pin function, gain range, common-mode limits, reference implementation, supply requirements, and assembly method.
Calculate the die-level power dissipation from the actual supply voltage, output voltage, and load current, then verify that the assembled module can remove the resulting heat. The available information identifies a bare-die package but does not establish a final junction-to-ambient thermal resistance. Use the package assembly and thermal information for the selected die configuration before assigning the maximum permissible dissipation.
Thông tin tuân thủ
Compliance status was not identified in the product information for the INA125TDA2 die ordering configuration.