Texas Instruments

INA125TDA2 - 10000:1 Instrumentation Amplifier | Texas Instruments

MPN: INA125TDA2 ✓ Active
10000 Vdss Rectangular bare die Package
MOQ: 1 |

INA125TDA2 Overview

The Texas Instruments INA125TDA2 is a single-circuit instrumentation amplifier with an integrated precision voltage reference, a maximum voltage gain of 10000, and a 17-terminal bare-die package. It is designed for precision measurement systems that require differential signal amplification, high common-mode rejection, and adjustable gain. The device also provides a nominal gain-bandwidth product of 0.15 MHz and maximum nonlinearity of 0.004%.

An instrumentation amplifier is a precision analog amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal architecture is designed to provide high input impedance, controlled differential gain, and strong rejection of common-mode interference. This makes instrumentation amplifiers distinct from general-purpose operational amplifiers and places them within the amplifier IC hierarchy used for sensor conditioning, bridge excitation, and high-precision signal acquisition.

Key characteristics include a maximum voltage gain of 10000, minimum common-mode rejection ratio of 107 dB, nominal bandwidth of 0.15 MHz, and maximum nonlinearity of 0.004%. The integrated precision voltage reference supports applications that need a controlled reference in addition to differential amplification. The single-circuit implementation also reduces the number of separate amplifiers needed for one measurement channel.

The INA125 architecture supports programmable gain through external components and is suited to analog front ends where signal gain must be selected according to sensor output and input range. Its high common-mode rejection is valuable when a low-level sensor signal is measured in the presence of system-level interference. Because the INA125TDA2 is supplied as bare die, final package options, pin assignments, bonding details, and production integration requirements must be confirmed directly with Texas Instruments before a PCB or multichip-module design is released.

Typical applications include bridge-based pressure and force measurement, precision current sensing, laboratory instrumentation, industrial sensor interfaces, and medical monitoring circuits. In a bridge circuit, the device can amplify the small differential bridge voltage while rejecting much of the common excitation voltage and its associated noise. The integrated reference can also support excitation or signal-conditioning systems that require a stable, controlled reference.

The most important design consideration is package integration because INA125TDA2 is a die rather than a standard molded package. Designers should obtain the manufacturer’s die-product documentation and bonding information before assigning pads, defining the footprint, or estimating assembly yield. Input filtering, reference bypassing, gain-setting resistors, and output settling should also be evaluated against the selected gain and measurement bandwidth.

This page combines the identified electrical characteristics with application guidance, design considerations, sourcing information, and a transparent assessment of replacement options. The absence of confirmed pin-to-pin alternatives is itself important because a functionally similar amplifier in a different package is not a drop-in replacement.

Drop-in alternatives for INA125TDA2 — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

No drop-in alternatives available for this product.

Request Alternatives

INA125TDA2 Maximum Ratings & Electrical Characteristics

Product Type Instrumentation amplifier with precision voltage reference
Amplifier Circuit Count 1 circuit
Maximum Voltage Gain 10000
Maximum Nonlinearity 0.004%
Minimum Common-Mode Rejection Ratio 107 dB
Nominal Bandwidth 0.15 MHz
Package Form Rectangular bare die
Terminal Count 17 terminals
Terminal Form No lead
Reference Integrated precision voltage reference

INA125TDA2 rectangular bare die Pin Configuration Guide

Pin configuration for INA125TDA2 (rectangular bare die package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.

rectangular bare die package pinout diagram for INA125TDA2

No detailed pinout data available for INA125TDA2.

Refer to the datasheet for full pin configuration.

Typical Applications

INA125TDA2 is suitable for 6 applications: Bridge-Based Pressure Measurement, Precision Current Sensing, Laboratory Measurement Instrumentation, Industrial Sensor Signal Conditioning, Medical Monitoring Signal Chain, Precision Reference and Gain Stage.

🏭

Bridge-Based Pressure Measurement

The INA125TDA2 can condition the small differential output generated by a strain-gauge or resistive bridge while rejecting a much larger common-mode excitation voltage. Its maximum voltage gain of 10000 provides substantial amplification for low-level bridge outputs, and its minimum common-mode rejection ratio of 107 dB helps isolate the differential measurement from common-mode interference. The bare-die format makes this approach most appropriate when the sensor assembly or multichip module requires direct die integration rather than a conventional PCB footprint.

⚡

Precision Current Sensing

INA125TDA2 is suitable for amplifying a low-level differential voltage produced by a current shunt, current transformer, or precision sensing element. The 107 dB minimum common-mode rejection ratio is valuable when the sensed voltage is much smaller than the supply or surrounding signal levels, while the 0.15 MHz nominal bandwidth supports measurement channels that do not require high-speed signal capture. System designers should verify the common-mode range and gain-dependent stability before finalizing the analog front end.

🔧

Laboratory Measurement Instrumentation

Laboratory front ends often combine adjustable amplification, accurate differential measurement, and a stable reference in a single signal-conditioning channel. The INA125TDA2 combines a maximum gain of 10000, 0.004% maximum nonlinearity, an integrated precision voltage reference, and strong common-mode rejection. Those characteristics make it relevant to bench instruments and precision test systems. Its 17-terminal bare-die construction requires a controlled die-integration process and manufacturer-approved assembly documentation.

🏭

Industrial Sensor Signal Conditioning

Industrial sensors can generate small differential outputs while the surrounding process equipment introduces large common-mode voltages. INA125TDA2 can provide the front-end gain, reaching 10000 maximum voltage gain, while its 107 dB minimum common-mode rejection ratio limits the influence of common-mode signals. The integrated precision reference supports controlled measurement-system architectures. Because the device is supplied as bare die, it is best suited to applications that already include qualified die bonding, inspection, and calibration capabilities.

💊

Medical Monitoring Signal Chain

INA125TDA2 may be considered for biomedical monitoring modules in which a small sensor voltage must be separated from a larger common-mode potential before digitization. Its 0.004% maximum nonlinearity supports precision signal conditioning, and its high common-mode rejection ratio helps protect weak sensor signals from common-mode interference. Medical designs must additionally validate input protection, patient isolation, leakage, noise, regulatory requirements, and the complete assembled system rather than relying on the amplifier specifications alone.

🧩

Precision Reference and Gain Stage

The integrated precision voltage reference makes INA125TDA2 more than a conventional differential gain stage. A measurement system can use the reference for controlled excitation, calibration, or signal-conditioning support while the amplifier handles a differential input. Its maximum voltage gain of 10000 and 0.15 MHz nominal bandwidth define the useful operating envelope for low-frequency precision measurements. External reference-decoupling and gain-setting components must follow the manufacturer’s recommended application circuit.

What is the Texas Instruments INA125TDA2?
The INA125TDA2 is a single-circuit instrumentation amplifier with an integrated precision voltage reference and a maximum voltage gain of 10000. Texas Instruments identifies the part as a 17-terminal, no-lead rectangular bare die. According to the manufacturer product page for the INA125 family, its role is precision differential-signal conditioning with high common-mode rejection.
What are the key specifications of INA125TDA2 that engineers should know?
The principal INA125TDA2 specifications include 10000 maximum voltage gain, 107 dB minimum common-mode rejection ratio, 0.15 MHz nominal bandwidth, and 0.004% maximum nonlinearity. The Texas Instruments INA125 family also incorporates a precision voltage reference. The INA125TDA2 ordering configuration is supplied as a 17-terminal bare die rather than a molded leaded package.
Where can I download the INA125TDA2 datasheet PDF?
The official INA125TDA2 documentation is available through the Texas Instruments INA125 product page at https://www.ti.com/product/INA125. The page provides manufacturer product information, ordering information, and datasheet access. Use the orderable INA125TDA2 entry to confirm which document and package information apply specifically to the bare-die ordering code.
Where can I find the INA125TDA2 pinout?
The INA125TDA2 pinout must be obtained from the die-product information supplied by Texas Instruments because INA125TDA2 is a 17-terminal bare die rather than a standard molded package. Do not infer bonding-pad positions from the 17-terminal count alone. Request the applicable die drawing, pad identifiers, and assembly recommendations before creating the PCB footprint or wire-bond plan.
Can INA125TDA2 be used for bridge sensor measurements?
Yes, the INA125TDA2 is suitable for bridge sensor measurements when its input, supply, gain, and common-mode limits match the selected bridge and excitation scheme. Its 10000 maximum gain and 107 dB minimum common-mode rejection ratio support precision extraction of small differential bridge signals. The integrated precision voltage reference is also useful in measurement systems that need a controlled reference.
Where can I buy INA125TDA2 online?
Use the “Request a Quote” form on this page to request INA125TDA2 pricing, stock confirmation, packaging details, and production lead time. The INA125TDA2 is a bare-die ordering configuration, so assembly method, bonding requirements, and production quantity can affect the quotation. Confirm that the quoted item is exactly INA125TDA2 before releasing a purchase order.
What is the current price of INA125TDA2?
Submit the INA125TDA2 inquiry through the “Request a Quote” form on this page for a current unit-price quotation. Bare-die pricing can depend on order quantity, die orientation, assembly service, delivery schedule, and contractual terms. The request form provides the appropriate commercial channel without embedding a potentially stale price in this technical page.
What is the lead time for INA125TDA2?
The current lead time for INA125TDA2 should be confirmed through the “Request a Quote” form on this page. Because INA125TDA2 is a bare-die product, procurement timing may depend on wafer availability, die stock, customer assembly requirements, and production scheduling. Include the forecast quantity and required delivery date with the inquiry.
Is INA125TDA2 in stock?
Current INA125TDA2 stock status should be confirmed through the “Request a Quote” form on this page. A listing indicating immediate shipment does not establish availability for every quantity or assembly condition. Provide the required quantity, delivery date, and die-handling requirements so the supplier can confirm the appropriate production position.
What can replace INA125TDA2?
No confirmed pin-to-pin drop-in replacement for INA125TDA2 is identified in the cross-reference records reviewed for this part. The target is a 17-terminal bare die, so a different molded package cannot be treated as a drop-in alternative even if its instrumentation-amplifier specifications are similar. Use the “Request a Quote” form for original-device sourcing or ask Texas Instruments for approved die and assembly options.
Is there a Texas Instruments equivalent for INA125TDA2?
No distinct Texas Instruments ordering code is confirmed as a pin-compatible drop-in equivalent for INA125TDA2. Other INA125 package options may provide similar core functionality, but they do not share the target’s bare-die footprint and therefore are not drop-in replacements. Review the Texas Instruments INA125 ordering table for device variants and contact the manufacturer when a package migration or multichip-module redesign is acceptable.
When should I choose INA125TDA2 instead of another instrumentation amplifier?
Choose INA125TDA2 when the design specifically requires a 17-terminal bare-die implementation and can use its 10000 maximum gain, 107 dB minimum common-mode rejection ratio, and integrated precision reference. Do not select it for a conventional PCB assembly simply because another amplifier has similar headline specifications. The package and assembly requirements are more restrictive than the electrical function.
Is INA125TDA2 suitable for precision industrial measurement?
The INA125TDA2 is appropriate for precision differential measurement when its electrical limits satisfy the sensor and signal-chain requirements. Its 107 dB minimum common-mode rejection ratio and 0.004% maximum nonlinearity are useful in industrial measurement systems where common-mode interference and gain nonlinearity must be controlled. The bare-die format requires an approved integration and assembly method.
INA125TDA2 vs a molded-package instrumentation amplifier: which is better?
A molded-package instrumentation amplifier is better when board-level assembly, test access, and mechanical simplicity dominate the design. INA125TDA2 is better when the application specifically requires its bare-die format, 10000 maximum gain, 107 dB minimum common-mode rejection ratio, and integrated precision voltage reference. A molded alternative may require a different footprint and therefore is not a drop-in replacement.
What design information is needed before packaging INA125TDA2?
Before packaging INA125TDA2, obtain the manufacturer’s die drawing, pad or bonding information, terminal definitions, assembly guidance, and handling requirements. The 17-terminal count and bare-die description are not enough to define a footprint. Also verify the selected gain, reference configuration, supply limits, and external-component values against the INA125 manufacturer documentation.

Engineering reference data for INA125TDA2 — comparison, design guidance, and compliance information.

Selection Guide

Choose INA125TDA2 only when a bare-die instrumentation-amplifier implementation is required and the design can support die bonding or multichip-module assembly. Its defining benefits are a maximum voltage gain of 10000, minimum common-mode rejection ratio of 107 dB, maximum nonlinearity of 0.004%, nominal bandwidth of 0.15 MHz, and an integrated precision voltage reference. For ordinary PCB-based products, a molded-package instrumentation amplifier will usually simplify assembly, inspection, replacement, and mechanical design, even when its electrical specifications are comparable. Because no pin-compatible alternative for the 17-terminal bare-die footprint was confirmed, changing packages should be treated as a redesign rather than a substitution. Obtain the manufacturer’s die, pin, ordering, and assembly documentation before committing the design, and use the Request a Quote form for commercial availability and production scheduling.

Comparison with Alternatives

Parameter This Product
Package 17-terminal rectangular bare die, no lead
Brand Texas Instruments
Product Type Instrumentation amplifier with precision voltage reference
Circuit Count 1 circuit
Maximum Voltage Gain 10000
Maximum Nonlinearity 0.004%
Minimum Common-Mode Rejection Ratio 107 dB
Nominal Bandwidth 0.15 MHz
Terminal Count 17 terminals
Reference Integrated precision voltage reference

Design Notes

Do not create a conventional PCB footprint from the 17-terminal count alone. INA125TDA2 is a bare die, so obtain the manufacturer’s die drawing and terminal map before defining copper, bonding pads, or assembly keepouts. The package library uses a generic diagram only because no public molded-package pinout applies to this ordering configuration.

Treat the reference and gain-setting nodes as sensitive analog nodes. Keep external gain-setting and reference-bypass components close to the device where the die-level assembly permits, and route them away from high-current switching paths. Verify settling and bandwidth at the selected gain because the device’s nominal bandwidth is 0.15 MHz and its usable bandwidth can vary with gain.

A similar instrumentation amplifier in a molded package is not a drop-in replacement for INA125TDA2. Package migration changes the mechanical footprint, assembly process, thermal behavior, and possibly the available ordering configuration. Select a substitute only after comparing the complete pin function, gain range, common-mode limits, reference implementation, supply requirements, and assembly method.

Calculate the die-level power dissipation from the actual supply voltage, output voltage, and load current, then verify that the assembled module can remove the resulting heat. The available information identifies a bare-die package but does not establish a final junction-to-ambient thermal resistance. Use the package assembly and thermal information for the selected die configuration before assigning the maximum permissible dissipation.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

Compliance status was not identified in the product information for the INA125TDA2 die ordering configuration.

Related Searches

INA125TDA2 datasheet INA125TDA2 datasheet pdf INA125TDA2 pinout INA125TDA2 bare die INA125TDA2 equivalent INA125TDA2 replacement INA125TDA2 cross reference Texas Instruments INA125TDA2 INA125TDA2 price INA125TDA2 stock INA125TDA2 application circuit INA125TDA2 packaging

Related Components & Terms

Texas Instruments INA125TDA2 INA125 instrumentation amplifier precision voltage reference differential amplifier analog signal conditioning amplifier IC semiconductor common-mode rejection ratio CMRR maximum voltage gain gain-bandwidth product nonlinearity bridge sensor strain gauge current shunt industrial measurement medical monitoring laboratory instrumentation bare die 17-terminal no-lead package Texas Instruments cross-reference search precision measurement
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details