INA129SJD - Precision Low-Power Instrumentation Amplifier | TI
MPN: INA129SJD ✓ Hoạt độngINA129SJD Tóm tắt
An instrumentation amplifier is a specialized amplifier category designed to amplify small differential signals while rejecting large common-mode voltages. INA129 belongs to the broader hierarchy of operational amplifiers, amplifier ICs, and analog signal-chain semiconductors. It is particularly useful when a sensor output is much smaller than the voltage referenced to ground and must be measured accurately in industrial, medical, or test equipment.
Key characteristics include a typical input bias current of 50 nA, a typical common-mode rejection ratio of 95 dB, and a slew rate of 4 V/µs. The INA129-HT family uses a gain equation compatible with the AD620, making it appropriate for designs based on familiar INA129 or AD620 gain-setting networks. The input stage also supports operation where transient voltage appears at the measurement inputs, while low quiescent current helps limit power consumption in continuously energized equipment.
The INA129SJD combines differential measurement capability with a low-power architecture suitable for battery-operated and space-constrained instruments. Its typical 700 µA supply current supports efficient operation when the amplifier remains active during long measurement intervals. Designers can use the external gain resistor to establish the required amplification while preserving the differential input arrangement and common-mode rejection characteristics.
Typical uses include bridge-strip and RTD sensor interfaces, isolated industrial monitoring, medical instrumentation, battery-powered data acquisition, and precision laboratory measurement. The high input impedance associated with the 50 nA typical bias current reduces loading on high-impedance sources. In systems with substantial ground offsets, the 95 dB typical common-mode rejection helps preserve measurement integrity.
When laying out the circuit, keep the input, feedback, and gain-resistor paths compact and electrically symmetric to minimize parasitic imbalance. Place input protection and filtering components only after checking their capacitance, leakage, and tolerance effects on input bias current and common-mode performance. Verify the power-supply arrangement against the ±18 V operating range and the ±40 V protected-input condition.
This product overview combines the manufacturer specifications with package information, application guidance, and compatible same-family options for engineers evaluating instrumentation-amplifier selections. The comparison and design notes emphasize practical fit, package compatibility, and the trade-offs between precision, protection, power, and gain functionality.
Bộ thay thế dễ dàng lắp đặt cho INA129SJD — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
INA128SJD
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
INA127SJD
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
INA126SJD
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
INA120SJD
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
INA129SJD Tỷ lệ tối đa & tính chất điện
| Amplifier Type | Precision instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Hộp | 8-CDIP (0.300 in, 7.62 mm) |
| Kiểu lắp đặt | Through-hole |
| Supply Voltage Range | ±18 V |
| Điện áp cung cấp | 700 µA typical |
| Điện áp yên tĩnh | 2 mA typical |
| Input Bias Current | 50 nA typical |
| Common-Mode Rejection Ratio | 95 dB typical |
| Input Protection Range | ±40 V |
| Slew Rate | 4 V/µs |
| Offset Voltage | 25 µV typical |
| Common-Mode Rejection at Gain 100 or Higher | 93 dB |
| Khoảng nhiệt độ hoạt động | -40 °C to +85 °C |
| Gain Equation | Compatible with the AD620 gain equation |
| RoHS Compliance | unknown |
| REACH Compliance | unknown |
| AEC-Q100 Qualification | unknown |
Hướng dẫn cấu hình chân INA129SJD 8-cdip (0.300 in, 7.62 mm)
Cấu hình chân cho INA129SJD (8-cdip (0.300 in, 7.62 mm) gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho INA129SJD.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
INA129SJD phù hợp cho 6 Áp dụngs: Bridge and Load-Cell Measurement, RTD Temperature Sensing, Battery-Powered Data Acquisition, Medical Signal Conditioning, Precision Test and Measurement, Industrial Process Monitoring.
Bridge and Load-Cell Measurement
The INA129SJD fits bridge-based sensor front ends that require differential excitation-signal measurement with substantial common-mode voltage. Its 95 dB typical common-mode rejection helps preserve small bridge differentials, while the 50 nA typical input bias current limits loading on the sensor and feedback network. The amplifier can be placed close to the bridge with the gain resistor and feedback components arranged symmetrically. A 4 V/µs slew rate supports measurement bandwidth, although the exact closed-loop bandwidth must be checked at the selected gain before setting the system sampling rate.
Được đề xuất
RTD Temperature Sensing
The INA129SJD is suitable for resistance-based temperature sensors when the measurement requires low input bias current and rejection of voltage common to both sensor leads. Its typical 50 nA bias current reduces the error introduced into a high-resistance RTD circuit, and the 95 dB typical common-mode rejection helps distinguish the small resistance-derived differential signal from ground offsets. Place the device near the RTD connections, keep input traces matched, and use high-quality resistors for excitation and gain-setting functions. Leakage from board contamination and protection components can dominate otherwise accurate RTD measurements.
Được đề xuất
Battery-Powered Data Acquisition
The INA129SJD fits portable acquisition systems where continuous amplifier power must remain low. Its 700 µA typical supply current reduces demand on the battery and power-conversion subsystem, while the instrumentation-amplifier configuration simplifies the acquisition of differential sensor outputs. The ±18 V supply capability supports bipolar-style laboratory rails, although lower-voltage operation may be used where signal levels permit. Design the analog filter and gain network to avoid excessive current, and use low-leakage input protection components if the source impedance is high.
Được đề xuất
Medical Signal Conditioning
The INA129SJD can be used in precision medical instrumentation when a differential bio-signal or sensor-derived voltage must be amplified before conversion. The 25 µV typical offset voltage supports low-level measurement, and the 95 dB typical common-mode rejection helps reject offsets shared by the sensing electrodes and analog front end. The 50 nA typical input bias current is advantageous for high-impedance sources. Actual medical suitability remains application-specific: validate leakage, safety isolation, noise, bandwidth, and applicable medical requirements rather than treating the amplifier grade alone as system certification.
Được đề xuất
Precision Test and Measurement
The INA129SJD is appropriate for laboratory instrumentation that measures low-level differential voltages while rejecting a larger common-mode reference. The 4 V/µs slew rate supports faster input transitions, and the AD620-compatible gain equation simplifies adaptation of designs using a familiar resistor-based gain network. Use the amplifier close to the source connector to minimize noise pickup, maintain symmetrical routing around the differential inputs, and select the external gain resistor for the required accuracy and stability. Check the applicable gain-bandwidth limit before selecting the maximum measurement rate.
Được đề xuất
Industrial Process Monitoring
The INA129SJD fits industrial monitoring systems that combine long sensor wiring with relatively small differential signals. The ±40 V input protection rating provides additional tolerance for transient voltage at the measurement inputs, while 95 dB typical common-mode rejection helps reject plant-level voltage offsets. Common-mode range, gain, bandwidth, and protection behavior must all remain within the final operating conditions. A shielded enclosure, protected input routing, and properly scaled gain network are important when the device is installed near motors, switching equipment, or other noisy industrial sources.
Được đề xuất
Dữ liệu tham khảo kỹ thuật cho INA129SJD — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | INA128SJD | INA127SJD | INA126SJD | INA120SJD |
|---|---|---|---|---|---|
| Package | 8-CDIP (0.300 in, 7.62 mm) | 8-CDIP (0.300 in, 7.62 mm) | 8-CDIP (0.300 in, 7.62 mm) | 8-CDIP (0.300 in, 7.62 mm) | 8-CDIP (0.300 in, 7.62 mm) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Number of Circuits | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
Bảo phân biệt quan trọng
- Lower-power INA129 architecture in the same DIP family (vsINA128SJD)
- Strong typical common-mode rejection (vsINA126SJD)
- Protected differential inputs for industrial environments (vsINA120SJD)
- Precision offset for low-level measurement (vsINA127SJD)
Ghi chú thiết kế
Route the two differential inputs as a closely matched pair and keep them away from clocks, switching nodes, and high-current return paths. Place the INA129SJD near the sensor or connector so that small sensor signals are amplified before board-level noise is picked up. Keep the gain-resistor and feedback connections short and symmetrical, because unequal parasitic capacitance can reduce common-mode rejection at higher frequencies.
Decouple each supply connection near the device with a local bypass capacitor selected for the required bandwidth and effective capacitance. Verify startup, output settling, and noise behavior with the actual source impedance because a large series impedance can create an additional pole. Keep the operating supply within ±18 V and distinguish that normal operating limit from the ±40 V protected-input condition.
Do not assume that every INA-series amplifier uses the same gain equation or gain range. The INA129-HT gain equation is compatible with the AD620, but INA120, INA126, INA127, and INA128 family members can differ in gain, bandwidth, offset, and supply-current behavior. Recalculate the external resistor and verify signal bandwidth whenever changing between family members.
For high-impedance sensors, minimize leakage from PCB contamination, connectors, protection devices, and flux residue. The 50 nA typical input bias current is a useful starting point, but error current can become significant when source resistance is high. Use guarding where appropriate and select low-leakage components whose capacitance does not unbalance the differential inputs.
Estimated power dissipation is calculated as P = (VS - VOUT) × IOUT plus internal bias current effects. For example, at 15 V supply, 5 V output, and 1 mA load, the voltage-drop loss is approximately 10 mW before reference and bias-current losses. Use the manufacturer's maximum power and junction-temperature ratings to determine whether the CDIP layout requires thermal copper or airflow.
Thông tin tuân thủ
The INA129 family is described by Texas Instruments as precision, low-power instrumentation amplifiers for operation from -40 °C to +85 °C. No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was identified in the cited product material.