INA2128UG4 - Dual Instrumentation Amplifier | Texas Instruments
MPN: INA2128UG4 ✓ Hoạt độngINA2128UG4 Tóm tắt
An instrumentation amplifier is a precision analog signal-conditioning IC that amplifies the voltage difference between two inputs while rejecting common-mode signals. Its internal three-op-amp architecture provides a practical combination of high input impedance, accurate differential gain, and common-mode rejection. This places the INA2128UG4 in the hierarchy of instrumentation amplifier, analog signal conditioner, amplifier IC, and semiconductor.
The principal features include a dual-channel configuration, low-power operation, user-programmable gain from 1 to 10,000 using one external resistor, and current-feedback input circuitry that maintains useful bandwidth at high gain. These characteristics suit sensor outputs, bridge-based measurements, biomedical instrumentation, and analog signal chains where small differential signals must be measured accurately in the presence of larger common-mode voltages.
The three-op-amp topology separates differential input handling from the gain-setting network, helping simplify circuit design and reduce external component count. A single gain resistor establishes the selected gain, while internal input and feedback stages provide the required signal amplification. The result is a versatile general-purpose instrumentation amplifier that can serve both precision measurement and general instrumentation applications.
Typical uses include pressure and temperature sensor interfaces, strain-gauge and Wheatstone bridge excitation, biomedical signal acquisition, current-shunt measurement, laboratory instrumentation, and low-level analog front ends. The dual architecture allows two independent sensor channels in one package, reducing board area when both channels are required.
Designers should place the gain-setting resistor close to the gain pins, observe the input and output common-mode limits, and decouple the supply pins according to the manufacturer datasheet. Input and output filtering should be selected for the required bandwidth because excessive capacitance can affect stability and phase margin. The operating temperature range also requires thermal verification for the complete board assembly.
This product page combines the INA2128UG4 device identity, package and gain details with practical application guidance, same-family alternatives, and a parameter-focused comparison. It is designed to help engineers locate the datasheet, verify pin compatibility, understand bandwidth constraints, and plan an instrumentation front end before requesting a quote.
Bộ thay thế dễ dàng lắp đặt cho INA2128UG4 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với INA2128UG4 (cùng hình factor và footprint) — khác nhau ở Architecture, Input Circuitry.
INA2128U
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA2128U/1KE4
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
INA2128U1G4
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
INA2128UG4 Tỷ lệ tối đa & tính chất điện
| Product Type | Dual instrumentation amplifier |
| Architecture | Three-op-amp design |
| Number of Amplifier Channels | 2 channels |
| Gain Range | 1 to 10,000 |
| Gain Setting Method | 1 external resistor |
| Bandwidth at Gain 100 | 200 kHz |
| Input Circuitry | Current feedback |
| Khoảng nhiệt độ hoạt động | -40°C to +85°C |
| Hộp | 16-pin SOIC |
| Kiểu lắp đặt | Surface mount |
Hướng dẫn cấu hình chân INA2128UG4 16-pin soic
Cấu hình chân cho INA2128UG4 (16-pin soic gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho INA2128UG4.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
INA2128UG4 phù hợp cho 6 Áp dụngs: Bridge Sensor Measurement, Medical Signal Acquisition, Current-Shunt Monitoring, Industrial Sensor Interface, Test and Measurement Instrumentation, Audio and Analog Signal Conditioning.
Bridge Sensor Measurement
The INA2128UG4 is well suited to strain-gauge, pressure, and other bridge-based sensors because its differential input arrangement measures the small bridge imbalance while rejecting the larger common-mode voltage. A single external resistor per channel sets the gain from 1 to 10,000, allowing the circuit to amplify a millivolt-level sensor output to a usable ADC input range. The current-feedback architecture retains 200 kHz bandwidth at gain 100, which supports dynamic measurements better than a narrow-band fixed-gain amplifier. The main design consideration is common-mode and output-range verification across the full bridge excitation and sensor tolerance.
Được đề xuất
Medical Signal Acquisition
The INA2128UG4 can serve as the analog front end for low-level biomedical sensor signals when two isolated or related channels are required. Its instrumentation-amplifier architecture provides differential measurement and common-mode rejection, while the programmable 1-to-10,000 gain range allows one device family to cover multiple sensor amplitudes. At gain 100, the manufacturer specifies 200 kHz bandwidth, providing adequate margin for many physiological waveforms without requiring an extremely high-speed amplifier. Designers should verify input bias current, offset, noise, and the medical system's applicable safety requirements separately.
Được đề xuất
Current-Shunt Monitoring
The INA2128UG4 is appropriate for measuring the differential voltage developed across a low-value current shunt. The amplifier converts the millivolt-scale shunt signal into a voltage suitable for an ADC, while its differential topology reduces disturbance from the supply rail and other shared signals. Two independent channels allow simultaneous measurement of a source and a reference load or two power rails. With gain adjustable from 1 to 10,000 and bandwidth of 200 kHz at gain 100, the device supports both slow power measurements and higher-bandwidth control loops when the complete signal chain permits.
Được đề xuất
Industrial Sensor Interface
The INA2128UG4 fits industrial sensor interfaces that combine a small differential signal with a substantially larger common-mode voltage. Its two channels reduce board area when monitoring two sensors, and the single-resistor gain setting simplifies calibration across different measurement ranges. The 200 kHz bandwidth at gain 100 allows the amplifier to preserve useful response for faster process-control signals while offering gains up to 10,000 for precision measurements. Layout should keep the gain resistor and feedback routing compact, and the completed circuit should be checked for supply variation, grounding, and common-mode excursions.
Được đề xuất
Test and Measurement Instrumentation
The INA2128UG4 is useful in laboratory and production-test front ends that measure small differential signals over a wide gain range. Its dual architecture can monitor two related nodes without duplicating the instrumentation amplifier, while the selectable 1-to-10,000 gain lets the same design cover low-level sensor outputs and larger differential test signals. Current-feedback input circuitry provides 200 kHz bandwidth at gain 100, making the device suitable for many bandwidth-oriented measurement setups. Gain accuracy, resistor tolerance, input noise, settling behavior, and output saturation must be evaluated against the measurement bandwidth and required uncertainty.
Được đề xuất
Audio and Analog Signal Conditioning
The INA2128UG4 can condition balanced or differential low-level audio signals where common-mode rejection and adjustable gain are important. The instrumentation-amplifier configuration accepts a differential source and provides a single-ended conditioned output, while two channels can process stereo or complementary signals. The 200 kHz bandwidth at gain 100 covers the full range of many audio-band applications, although the maximum gain of 10,000 should not be selected merely for headroom because bandwidth and noise performance change with gain. The design should include appropriate input filtering, grounding, and output-headroom checks.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho INA2128UG4 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | INA2128U | INA2128U/1KE4 | INA2128U1G4 |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC |
| Product Type | Dual low-power instrumentation amplifier | Dual low-power instrumentation amplifier | Dual low-power instrumentation amplifier | Dual low-power instrumentation amplifier |
| Architecture | Three-op-amp design | Three-op-amp design | Three-op-amp design | Three-op-amp design |
| Amplifier Channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Gain Range | 1 to 10,000 | 1 to 10,000 | 1 to 10,000 | 1 to 10,000 |
| Bandwidth at Gain 100 | 200 kHz | 200 kHz | 200 kHz | 200 kHz |
| Gain Setting | 1 external resistor | 1 external resistor | 1 external resistor | 1 external resistor |
| Input Circuitry | Current feedback | Current feedback | Current feedback | Current feedback |
Bảo phân biệt quan trọng
- Dual-channel integration in one package (vsINA2128U)
- Programmable gain spans four decades (vsINA2128U/1KE4)
- Useful bandwidth at high gain (vsINA2128U1G4)
- Compact surface-mount implementation (vsINA2128U)
Ghi chú thiết kế
Place each gain-setting resistor close to the corresponding INA2128UG4 gain pins and keep the input traces short and symmetric. Current-feedback input circuitry can be sensitive to parasitic capacitance and unequal trace lengths, particularly at high gain. Route input and feedback connections away from switching nodes and keep the ground return beneath the analog signal path to reduce pickup and ground-potential errors.
Do not assume that every INA2128 ordering suffix is interchangeable without checking accuracy grade, qualification, and temperature coverage. Compare the exact ordering table for the INA2128UG4, INA2128U, INA2128U/1KE4, and INA2128U1G4. Also verify that the selected gain keeps both inputs and the output inside their common-mode and output-swing limits under minimum supply, maximum load, and worst-case sensor voltage.
Choose input filtering only after accounting for the 200 kHz bandwidth specified at gain 100. A low-pass filter with a corner too close to the required signal bandwidth can create phase error, while excessive input capacitance may alter stability or bandwidth. Evaluate the complete gain, noise, settling-time, and filter behavior rather than evaluating the gain resistor and input network independently.
Decouple each supply rail close to the device and follow the capacitor values and layout shown in the manufacturer datasheet. The INA2128UG4 is a dual low-power instrumentation amplifier, but its total supply demand and any nearby precision converter or reference can still introduce local noise. Keep sensitive gain and feedback nodes away from regulator switching loops and ensure the power source has adequate transient response during startup and load changes.
Thông tin tuân thủ
No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statement was identified for this ordering code. Confirm compliance using the manufacturer's current product documentation.