INA2128UG4 - Dual Instrumentation Amplifier | Texas Instruments
MPN: INA2128UG4 ✓ 啟用中INA2128UG4 概覽
An instrumentation amplifier is a precision analog signal-conditioning IC that amplifies the voltage difference between two inputs while rejecting common-mode signals. Its internal three-op-amp architecture provides a practical combination of high input impedance, accurate differential gain, and common-mode rejection. This places the INA2128UG4 in the hierarchy of instrumentation amplifier, analog signal conditioner, amplifier IC, and semiconductor.
The principal features include a dual-channel configuration, low-power operation, user-programmable gain from 1 to 10,000 using one external resistor, and current-feedback input circuitry that maintains useful bandwidth at high gain. These characteristics suit sensor outputs, bridge-based measurements, biomedical instrumentation, and analog signal chains where small differential signals must be measured accurately in the presence of larger common-mode voltages.
The three-op-amp topology separates differential input handling from the gain-setting network, helping simplify circuit design and reduce external component count. A single gain resistor establishes the selected gain, while internal input and feedback stages provide the required signal amplification. The result is a versatile general-purpose instrumentation amplifier that can serve both precision measurement and general instrumentation applications.
Typical uses include pressure and temperature sensor interfaces, strain-gauge and Wheatstone bridge excitation, biomedical signal acquisition, current-shunt measurement, laboratory instrumentation, and low-level analog front ends. The dual architecture allows two independent sensor channels in one package, reducing board area when both channels are required.
Designers should place the gain-setting resistor close to the gain pins, observe the input and output common-mode limits, and decouple the supply pins according to the manufacturer datasheet. Input and output filtering should be selected for the required bandwidth because excessive capacitance can affect stability and phase margin. The operating temperature range also requires thermal verification for the complete board assembly.
This product page combines the INA2128UG4 device identity, package and gain details with practical application guidance, same-family alternatives, and a parameter-focused comparison. It is designed to help engineers locate the datasheet, verify pin compatibility, understand bandwidth constraints, and plan an instrumentation front end before requesting a quote.
直接替換替代品,適用於 INA2128UG4 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: INA2128UG4 (相同外形與佔位) — 差異在於 Architecture, Input Circuitry.
INA2128U
✅ 直接替換聯絡詢價
查看資料表 →INA2128U/1KE4
✅ 直接替換📋 參考替代品(不在目錄中)
INA2128U1G4
✅ 直接替換📋 參考替代品(不在目錄中)
INA2128UG4 最大額定值與電氣特性
| Product Type | Dual instrumentation amplifier |
| Architecture | Three-op-amp design |
| Number of Amplifier Channels | 2 channels |
| Gain Range | 1 to 10,000 |
| Gain Setting Method | 1 external resistor |
| Bandwidth at Gain 100 | 200 kHz |
| Input Circuitry | Current feedback |
| 工作溫度範圍 | -40°C to +85°C |
| 封裝 | 16-pin SOIC |
| 安裝類型 | Surface mount |
INA2128UG4 16-pin soic 腳位配置指南
INA2128UG4(16-pin soic 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA2128UG4.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA2128UG4 適用於 6 應用s: Bridge Sensor Measurement, Medical Signal Acquisition, Current-Shunt Monitoring, Industrial Sensor Interface, Test and Measurement Instrumentation, Audio and Analog Signal Conditioning.
Bridge Sensor Measurement
The INA2128UG4 is well suited to strain-gauge, pressure, and other bridge-based sensors because its differential input arrangement measures the small bridge imbalance while rejecting the larger common-mode voltage. A single external resistor per channel sets the gain from 1 to 10,000, allowing the circuit to amplify a millivolt-level sensor output to a usable ADC input range. The current-feedback architecture retains 200 kHz bandwidth at gain 100, which supports dynamic measurements better than a narrow-band fixed-gain amplifier. The main design consideration is common-mode and output-range verification across the full bridge excitation and sensor tolerance.
推薦
Medical Signal Acquisition
The INA2128UG4 can serve as the analog front end for low-level biomedical sensor signals when two isolated or related channels are required. Its instrumentation-amplifier architecture provides differential measurement and common-mode rejection, while the programmable 1-to-10,000 gain range allows one device family to cover multiple sensor amplitudes. At gain 100, the manufacturer specifies 200 kHz bandwidth, providing adequate margin for many physiological waveforms without requiring an extremely high-speed amplifier. Designers should verify input bias current, offset, noise, and the medical system's applicable safety requirements separately.
推薦
Current-Shunt Monitoring
The INA2128UG4 is appropriate for measuring the differential voltage developed across a low-value current shunt. The amplifier converts the millivolt-scale shunt signal into a voltage suitable for an ADC, while its differential topology reduces disturbance from the supply rail and other shared signals. Two independent channels allow simultaneous measurement of a source and a reference load or two power rails. With gain adjustable from 1 to 10,000 and bandwidth of 200 kHz at gain 100, the device supports both slow power measurements and higher-bandwidth control loops when the complete signal chain permits.
推薦
Industrial Sensor Interface
The INA2128UG4 fits industrial sensor interfaces that combine a small differential signal with a substantially larger common-mode voltage. Its two channels reduce board area when monitoring two sensors, and the single-resistor gain setting simplifies calibration across different measurement ranges. The 200 kHz bandwidth at gain 100 allows the amplifier to preserve useful response for faster process-control signals while offering gains up to 10,000 for precision measurements. Layout should keep the gain resistor and feedback routing compact, and the completed circuit should be checked for supply variation, grounding, and common-mode excursions.
推薦
Test and Measurement Instrumentation
The INA2128UG4 is useful in laboratory and production-test front ends that measure small differential signals over a wide gain range. Its dual architecture can monitor two related nodes without duplicating the instrumentation amplifier, while the selectable 1-to-10,000 gain lets the same design cover low-level sensor outputs and larger differential test signals. Current-feedback input circuitry provides 200 kHz bandwidth at gain 100, making the device suitable for many bandwidth-oriented measurement setups. Gain accuracy, resistor tolerance, input noise, settling behavior, and output saturation must be evaluated against the measurement bandwidth and required uncertainty.
推薦
Audio and Analog Signal Conditioning
The INA2128UG4 can condition balanced or differential low-level audio signals where common-mode rejection and adjustable gain are important. The instrumentation-amplifier configuration accepts a differential source and provides a single-ended conditioned output, while two channels can process stereo or complementary signals. The 200 kHz bandwidth at gain 100 covers the full range of many audio-band applications, although the maximum gain of 10,000 should not be selected merely for headroom because bandwidth and noise performance change with gain. The design should include appropriate input filtering, grounding, and output-headroom checks.
推薦
推薦產品摘要
工程參考資料,適用於 INA2128UG4 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA2128U | INA2128U/1KE4 | INA2128U1G4 |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC |
| Product Type | Dual low-power instrumentation amplifier | Dual low-power instrumentation amplifier | Dual low-power instrumentation amplifier | Dual low-power instrumentation amplifier |
| Architecture | Three-op-amp design | Three-op-amp design | Three-op-amp design | Three-op-amp design |
| Amplifier Channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Gain Range | 1 to 10,000 | 1 to 10,000 | 1 to 10,000 | 1 to 10,000 |
| Bandwidth at Gain 100 | 200 kHz | 200 kHz | 200 kHz | 200 kHz |
| Gain Setting | 1 external resistor | 1 external resistor | 1 external resistor | 1 external resistor |
| Input Circuitry | Current feedback | Current feedback | Current feedback | Current feedback |
主要差異化特點
- Dual-channel integration in one package (對比INA2128U)
- Programmable gain spans four decades (對比INA2128U/1KE4)
- Useful bandwidth at high gain (對比INA2128U1G4)
- Compact surface-mount implementation (對比INA2128U)
設計說明
Place each gain-setting resistor close to the corresponding INA2128UG4 gain pins and keep the input traces short and symmetric. Current-feedback input circuitry can be sensitive to parasitic capacitance and unequal trace lengths, particularly at high gain. Route input and feedback connections away from switching nodes and keep the ground return beneath the analog signal path to reduce pickup and ground-potential errors.
Do not assume that every INA2128 ordering suffix is interchangeable without checking accuracy grade, qualification, and temperature coverage. Compare the exact ordering table for the INA2128UG4, INA2128U, INA2128U/1KE4, and INA2128U1G4. Also verify that the selected gain keeps both inputs and the output inside their common-mode and output-swing limits under minimum supply, maximum load, and worst-case sensor voltage.
Choose input filtering only after accounting for the 200 kHz bandwidth specified at gain 100. A low-pass filter with a corner too close to the required signal bandwidth can create phase error, while excessive input capacitance may alter stability or bandwidth. Evaluate the complete gain, noise, settling-time, and filter behavior rather than evaluating the gain resistor and input network independently.
Decouple each supply rail close to the device and follow the capacitor values and layout shown in the manufacturer datasheet. The INA2128UG4 is a dual low-power instrumentation amplifier, but its total supply demand and any nearby precision converter or reference can still introduce local noise. Keep sensitive gain and feedback nodes away from regulator switching loops and ensure the power source has adequate transient response during startup and load changes.
合規資訊
No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statement was identified for this ordering code. Confirm compliance using the manufacturer's current product documentation.