INA333SHKQ - Zero-Drift Instrumentation Amplifier | Texas Instruments
MPN: INA333SHKQ ✓ Hoạt độngINA333SHKQ Tóm tắt
An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals while rejecting common-mode interference. Its internal differential architecture preserves signal integrity when the inputs share substantial common-mode voltage. Within the broader semiconductor hierarchy, an instrumentation amplifier belongs to the amplifier IC family and combines precision input, gain-setting, and differential-to-single-ended conversion functions in one device.
The INA333SHKQ supports closed-loop gains from 100 to 1000 V/V. At a gain of 100, the manufacturer lists a maximum input offset voltage of 25 µV, a typical drift of 0.2 µV/°C, and noise density of 55 nV/√Hz. Its listed common-mode rejection is at least 100 dB at a gain of 10. These characteristics make the amplifier suitable for bridge-based sensors where small millivolt-level differential outputs must be measured accurately.
The device operates from a single 1.8 V to 3.5 V supply according to the INA333 family specifications. Its rail-to-rail output stage permits the output voltage to approach the supply limits, improving utilization of low-voltage signal chains. A single external resistor sets the gain, simplifying implementation while preserving accurate differential amplification. The micro-power operating current supports battery-operated instrumentation where continuous sensor monitoring is required without excessive load.
Typical uses include pressure and force transducers, thermocouple and RTD interfaces, biomedical instrumentation, portable measurement systems, and industrial process-control equipment. The -55°C to +210°C operating range distinguishes the SHKQ grade from the standard commercial INA333 variants and supports use in high-temperature measurement environments.
When laying out an INA333SHKQ circuit, route the differential input and gain-resistor connections as short, symmetric traces, and place input filtering close to the source. Check common-mode input limits at the selected supply voltage because the allowable input range is not independent of supply. Confirm output headroom at the required gain and load, especially in low-voltage systems where rail-to-rail output behavior is important.
This page combines the high-temperature INA333SHKQ specifications with application guidance, package information, engineering design notes, and a careful drop-in replacement assessment. It is intended to help engineers determine whether the device fits a precision sensing application without overlooking gain, temperature, supply, or PCB-footprint constraints.
Bộ thay thế dễ dàng lắp đặt cho INA333SHKQ — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Không có bộ thay thế dễ dàng lắp đặt sẵn có cho sản phẩm này.
Yêu cầu các bộ thay thếINA333SHKQ Tỷ lệ tối đa & tính chất điện
| Product Type | Micro-power zero-drift instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Closed-Loop Gain Range | 100 to 1000 V/V |
| Điện áp cung cấp | 5 V typical |
| Input Offset Voltage at Gain 100 | 25 µV maximum |
| Input Offset Voltage Drift at Gain 100 | 0.2 µV/°C typical |
| Noise Density at Gain 100 | 55 nV/√Hz |
| Common-Mode Rejection at Gain 10 | 100 dB minimum |
| Input Bias Current | 2.0 µA typical |
| Slew Rate | 0.040 V/µs |
| Kiểu đầu ra | Rail-to-rail output |
| Khoảng nhiệt độ hoạt động | -55°C to +210°C |
| Package Type | 8-pin CFP (HKQ) |
| Số lượng chân | 8 pins |
| Manufacturer | Texas Instruments |
Hướng dẫn cấu hình chân INA333SHKQ 8-pin cfp (hkq)
Cấu hình chân cho INA333SHKQ (8-pin cfp (hkq) gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho INA333SHKQ.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
INA333SHKQ phù hợp cho 6 Áp dụngs: High-Temperature Pressure Transducers, Battery-Powered Sensor Interfaces, Biomedical and Diagnostic Sensing, RTD and Thermocouple Measurement, Industrial Process and Force Measurement, Precision Test and Measurement.
High-Temperature Pressure Transducers
The INA333SHKQ is appropriate for bridge-based pressure transducers that produce small differential signals but share a larger common-mode voltage. Its gain range of 100 to 1000 V/V provides substantial signal amplification, while the specified 100 dB minimum common-mode rejection at gain 10 supports rejection of common supply and ground disturbances. The -55°C-to-+210°C operating range is valuable in pressure-monitoring equipment installed near heated process equipment. A practical implementation places the bridge excitation and amplifier inputs close together, uses one accurate external gain resistor, and checks that the bridge midpoint remains inside the amplifier's allowable common-mode range.
Được đề xuất
Battery-Powered Sensor Interfaces
The INA333SHKQ fits portable sensing systems where energy use limits how aggressively the input stage can operate. Its micro-power architecture supports continuous monitoring of differential sensor outputs without adding the higher supply current associated with many general-purpose amplifier stages. Gains up to 1000 V/V allow weak bridge or transducer outputs to be amplified before conversion by an ADC. Because the part also offers rail-to-rail output, the signal can use much of a low-voltage supply range. Design the gain resistor for the required sensitivity, add input filtering matched to the sensor bandwidth, and account for amplifier and sensor current when calculating battery life.
Được đề xuất
Biomedical and Diagnostic Sensing
The INA333SHKQ can amplify small differential bio-sensor or diagnostic signals when the design requires its precision offset and drift characteristics. The listed 25 µV maximum input offset voltage at gain 100 and 0.2 µV/°C typical drift provide a useful starting point for determining whether gain-induced output error remains acceptable. Rail-to-rail output can improve signal utilization in compact, low-voltage instruments. Designers must still validate leakage, input protection, isolation, patient-safety requirements, and applicable medical standards for the complete system; the amplifier's temperature rating alone does not establish medical-system compliance.
Được đề xuất
RTD and Thermocouple Measurement
The INA333SHKQ is suitable for low-level temperature-sensor interfaces when the selected gain keeps the signal within the amplifier's input and output ranges. A gain of 100 produces meaningful amplification for millivolt-class RTD signals, while the instrumentation-amplifier architecture rejects common-mode noise encountered on shared sensor wiring. The 0.2 µV/°C typical drift at gain 100 is especially relevant when measuring small temperature changes over a wide ambient range. For thermocouples, confirm the cold-junction compensation and input polarity, while for RTDs apply excitation current and ratiometric calibration carefully. Input filtering should reject mains-frequency interference without removing the desired thermal response.
Được đề xuất
Industrial Process and Force Measurement
The INA333SHKQ supports precision industrial force, load-cell, and process-sensor interfaces where the transducer output is differential and relatively small. Gains from 100 to 1000 V/V allow the same amplifier family to cover different sensor sensitivities, while the high-temperature grade supports equipment operating near hot machinery or ovens. Maintain symmetry between input and return paths to prevent conversion of common-mode noise into differential error. Calibrate gain and offset over the expected temperature range, provide suitable surge and ESD protection at external connectors, and verify that the common-mode input never leaves its valid operating region during startup or sensor faults.
Được đề xuất
Precision Test and Measurement
The INA333SHKQ is useful in bench and laboratory instruments that amplify low-level differential sources before accurate conversion or comparison. The 100-to-1000 V/V gain range supports common probe and sensor sensitivities, while the maximum 25 µV offset specification at gain 100 helps constrain fixed error after amplification. For resistance or thermocouple measurements, thermal gradients between the amplifier and precision resistor network can create errors greater than the listed offset, so use low-drift gain components and minimize temperature differences. The rail-to-rail output helps preserve resolution in low-voltage test systems, but the designer should still confirm output swing at the selected load and gain.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho INA333SHKQ — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này |
|---|---|
| Brand | Texas Instruments |
| Package | 8-pin CFP (HKQ) |
| Product Type | Micro-power zero-drift instrumentation amplifier |
| Closed-Loop Gain Range | 100 to 1000 V/V |
| Supply Voltage | 5 V typical |
| Input Offset Voltage at Gain 100 | 25 µV maximum |
| Offset Drift at Gain 100 | 0.2 µV/°C typical |
| Noise Density at Gain 100 | 55 nV/√Hz |
| Common-Mode Rejection at Gain 10 | 100 dB minimum |
| Operating Temperature Range | -55°C to +210°C |
Bảo phân biệt quan trọng
- High-temperature operational range (vsINA333SKGD1)
- Integrated gain range for precision differential measurement (vsOPA333AIDR)
- Low offset specification at useful gain (vsOPA333AIDR)
Ghi chú thiết kế
Route the two differential inputs as short, closely matched traces and connect the gain-setting resistor directly across the designated gain pins. Avoid introducing unequal copper lengths, long loops, or ground-current paths between the source and amplifier. For bridge sensors, position input filtering close to the INA333SHKQ so that transient energy is shunted before reaching the amplifier. Keep sensitive signal returns away from switching-converter outputs and high-current power paths.
Verify the common-mode input range at the actual supply voltage and throughout startup, shutdown, and sensor-fault conditions. Rail-to-rail output does not imply that the input pins can tolerate every voltage reached on the external bus. Also calculate the offset contribution after multiplication by gain: 25 µV at gain 100 produces approximately 2.5 mV of output offset before calibration. Include offset drift of 0.2 µV/°C typical in long-distance or high-temperature measurements.
Place input and output bypass capacitors close to their associated pins and use a quiet ground reference for the analog path. Decouple the amplifier supply locally so that switching-node current does not flow through sensitive signal-return copper. Check the output-voltage headroom at the intended load and gain, particularly in low-voltage designs where the usable swing is limited by the output current and output configuration.
The INA333SHKQ supports a -55°C-to-+210°C operating range, but that rating does not remove thermal-design requirements from the assembled instrument. Minimize temperature gradients between the amplifier, gain resistor, reference elements, and sensor because drift in external components can dominate the amplifier's 0.2 µV/°C typical offset drift. For high-temperature equipment, provide thermal isolation from hot structures and evaluate long-term offset stability at the actual operating temperature.
Thông tin tuân thủ
The manufacturer identifies INA333SHKQ as a high-temperature INA333 grade, but no specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was included in the product information reviewed for this page.