MAX232EIPWR - 250kbps RS-232 Transceiver | Texas Instruments (Tape & Reel)
MPN: MAX232EIPWR ✓ Hoạt độngMAX232EIPWR Tóm tắt
An RS-232 transceiver is an interface IC that bridges the voltage-domain difference between a digital controller and a physical RS-232 link. In the signal hierarchy, the MAX232EIPWR belongs to the RS-232 transceiver class, which combines line drivers, line receivers, and charge-pump voltage generation within one interface package. Unlike a TTL/CMOS serial controller, this device does not implement a communication protocol; it converts logic levels and protects the physical interface.
Key electrical features include 5V operation, dual transmit and receive channels, 250kbps maximum data rate, and approximately ±9V RS-232 output levels. According to the MAX232E product page, all RS-232 pins provide 15kV human-body-model and IEC61000-4-2 air-gap discharge protection. The line-driver pins additionally provide 8kV IEC61000-4-2 contact-discharge protection, making the interface suitable for industrial equipment, service ports, and external cables where electrostatic discharge is a practical concern.
The integrated voltage generator eliminates the need for a separate negative supply rail. Four charge-pump capacitors allow the device to translate TTL/CMOS transmit inputs into RS-232 levels from one 5V supply. Each receiver converts a TIA/EIA-232-F input into a 5V TTL/CMOS signal, allowing a microcontroller, programmable logic controller, or test system to communicate over a legacy serial port without a separate level-shifting circuit.
Typical uses include industrial control-panel service ports, configuration and debug interfaces, laboratory equipment, point-of-sale systems, and legacy peripherals that retain an RS-232 connection. The 250kbps capability supports moderate-rate command and data links, although the connected software protocol must also be configured for the selected baud rate. Because RS-232 is a point-to-point, single-ended interface, ground reference and cable routing remain important in multi-device installations.
For PCB layout, place the charge-pump capacitors and the VCC bypass capacitor close to their associated pins, and route the RS-232 driver and receiver connections directly to the connector. Keep logic-side traces away from exposed cable-facing nets, provide a stable chassis or signal-ground connection strategy, and avoid long unprotected stubs. The integrated ESD protection reduces connector-side risk but does not eliminate the need for good mechanical grounding and cable management.
This page consolidates the verified MAX232E electrical characteristics, ordering information, protection ratings, application guidance, and interface design considerations into a practical engineering reference. It also distinguishes the MAX232EIPWR from related MAX232 and MAX3232E family members so engineers can assess pin compatibility, supply voltage, data rate, and package differences before approving a substitution.
Bộ thay thế dễ dàng lắp đặt cho MAX232EIPWR — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với MAX232EIPWR (cùng hình factor và footprint) — khác nhau ở Package, Maximum Data Rate, Product Type, Supply Voltage Range.
MAX3232EIPWG4
✅ Drop-In ⚠️ Thông số chưa được xác minhLiên hệ để biết giá
Xem tài liệu →MAX232EIPWR Thông số kỹ thuật
| Product Type | Dual RS-232 driver and receiver transceiver |
| Number of Channels | 2 channels |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Điện áp cung cấp | 5 V |
| Maximum Data Rate | 250 kbps |
| RS-232 Output Level | Approximately -9 V to +9 V |
| Receiver Input Level | TIA/EIA-232-F input converted to 5 V TTL/CMOS |
| On-Chip Voltage Generator | Yes, capacitive voltage generator using four capacitors |
| ESD Protection on RS-232 Pins | 15 kV HBM and 15 kV IEC61000-4-2 air-gap discharge |
| Contact Discharge Protection | 8 kV IEC61000-4-2 on RS-232 driver pins |
| Hộp | 16-pin TSSOP |
| Kiểu lắp đặt | Surface mount |
| Supply Topology | Single 5 V supply |
| Standard | TIA/EIA-232-F |
Hướng dẫn cấu hình chân MAX232EIPWR 16-pin tssop
Cấu hình chân cho MAX232EIPWR (16-pin tssop gói). Số thứ tự chân, chức năng và sơ đồ kết nối được xác định trong tài liệu thông số kỹ thuật của nhà sản xuất. Tham khảo nó để biết footprint và hướng dẫn hàn chính xác.
Không có dữ liệu chân cụ thể sẵn có cho MAX232EIPWR.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
MAX232EIPWR phù hợp cho 6 Áp dụngs: Industrial Controller Service Port, Point-of-Sale Terminal Interface, Laboratory Instrument Control, Legacy Peripheral Upgrade, Programmable Logic Debug Interface, Data Acquisition and Test System.
Industrial Controller Service Port
The MAX232EIPWR fits an industrial controller that retains an RS-232 configuration or service port alongside a modern microcontroller. Its two driver and two receiver channels support bidirectional console communication, while the single 5V supply avoids a separate negative rail. The 15kV HBM and IEC61000-4-2 air-gap protection ratings improve robustness on externally accessible RS-232 pins. Place the charge-pump capacitors and supply bypass capacitor close to the device, and connect the cable shield or signal ground according to the installation’s grounding strategy.
Được đề xuất
Point-of-Sale Terminal Interface
A point-of-sale system can use the MAX232EIPWR to bridge a 5V controller to an RS-232 peripheral such as a receipt printer, customer display, or magnetic-stripe reader. Two channels allow separate transmit and receive paths without adding another transceiver. The integrated capacitive voltage generator produces the required bipolar RS-232 levels from the controller’s 5V supply. Keep the interface connector physically separated from high-current switching circuitry and verify that the peripheral’s electrical standard is TIA/EIA-232-F rather than RS-485.
Được đề xuất
Laboratory Instrument Control
The MAX232EIPWR can connect a laboratory instrument’s control board to a legacy RS-232 test fixture or service computer. Its 250kbps maximum data rate is suitable for command traffic and moderate measurement data, while the integrated voltage generator simplifies single-supply test equipment. ESD protection on the cable-facing pins helps laboratories where instruments are frequently connected and disconnected. For reliable measurements, use shielded cable, establish one reference ground, and avoid sharing noisy return paths between the interface and precision analog circuitry.
Được đề xuất
Legacy Peripheral Upgrade
The MAX232EIPWR allows a new digital controller to communicate with a legacy peripheral that exposes only an RS-232 connector. Because the receivers operate from the same 5V system used by many modern controllers, the interface can replace a more complex discrete level-shifting circuit. Verify the peripheral’s baud rate, logic polarity, handshake requirements, and connector pinout before connecting it. Software must also support the RS-232 protocol because the MAX232EIPWR performs only electrical level conversion and ESD protection.
Được đề xuất
Programmable Logic Debug Interface
The MAX232EIPWR can provide a simple two-channel console or programming interface for programmable logic or embedded-control boards. One pair of channels can carry serial commands and status information while another pair is available for auxiliary data or a second port. The 250kbps capability is substantially faster than the low-rate console links commonly used in RS-232 systems. Place the device near the connector, preserve the recommended charge-pump layout, and keep the logic-side interface away from the protected cable-side nets.
Được đề xuất
Data Acquisition and Test System
The MAX232EIPWR is useful in data-acquisition equipment that must retain an RS-232 link for calibration, logging, or external test commands. Its two full-duplex channels can operate on separate ports, and the integrated charge pump reduces external power-conversion complexity. The interface’s IEC61000-4-2 protection helps when the port is exposed to operator-accessible cables, although the overall enclosure still determines the final electrostatic-discharge environment. Use a dedicated return-ground path to keep interface transients away from measurement references.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho MAX232EIPWR — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | MAX3232EIPW | MAX232EIPWRR |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin TSSOP | 16-pin TSSOP | 16-pin TSSOP |
| Device Type | Dual RS-232 driver and receiver | Dual RS-232 driver and receiver | Dual RS-232 driver and receiver |
| Supply Voltage | 5 V | 5 V | 5 V |
| Maximum Data Rate | 250 kbps | 250 kbps | 250 kbps |
| Number of Channels | 2 | 2 | 2 |
| RS-232 Output Swing | Approximately ±9 V | Approximately ±9 V | Approximately ±9 V |
| Voltage Generator | Internal capacitive generator using four capacitors | Internal capacitive generator | Internal capacitive generator using four capacitors |
Bảo phân biệt quan trọng
- Integrated protected RS-232 interface in a single 5V part (vsMAX3232EIPW)
- Single-supply negative-rail generation (vsMAX232EIPWRR)
- Two-channel bidirectional connectivity (vsMAX3232EIPW)
Ghi chú thiết kế
Place the four charge-pump capacitors and the VCC bypass capacitor as close as practical to their specified pins. Keep the charge-pump loop compact because long traces and large loop area can increase radiated emissions. Follow the MAX232E datasheet for capacitor values and connections. Route the RS-232 connector nets directly to the transceiver, and keep those nets away from sensitive analog inputs and high-speed digital clocks.
Do not treat the RS-232 interface as a differential bus or connect it to an RS-485 receiver. MAX232EIPWR uses bipolar single-ended signaling and requires an RS-232-compatible receiver with the correct ground reference. Also verify the full device suffix before layout because package, temperature, and packing codes differ among MAX232E orderable configurations. Do not substitute a SOIC package for the specified 16-pin TSSOP without a PCB footprint change.
The on-chip capacitive voltage generator switches internally to create negative RS-232 voltage, so supply-current transitions and radiated noise deserve attention. Provide a low-impedance 5V connection, place the bypass capacitor adjacent to VCC, and avoid routing the charge-pump network beneath sensitive analog sections. At the cable interface, use a defined signal-ground or chassis-ground strategy appropriate to the equipment and keep exposed cable wiring short relative to the ESD-current path.
RS-232 is point-to-point, so each driver should connect to one receiving node and unused driver or receiver inputs should not be left as unterminated test points. Confirm the logic polarity of the connected controller, because the MAX232EIPWR provides voltage conversion rather than protocol inversion or configuration. Long cables can accumulate noise and reflections; use a quality shielded cable, maintain a continuous reference ground, and avoid daisy-chaining RS-232 ports.
Thông tin tuân thủ
The manufacturer documentation identifies IEC61000-4-2 air-gap and contact-discharge protection ratings. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not confirmed.