OPA228UA - 33 MHz Precision Op Amp | Texas Instruments
MPN: OPA228UA ✓ Hoạt độngOPA228UA Tóm tắt
An operational amplifier, or op amp, is an analog integrated circuit that amplifies the voltage difference between its inverting and non-inverting inputs while using negative feedback to establish gain and bandwidth. Within the broader power-management and signal-chain hierarchy, an op amp is a precision analog IC used for buffering, amplification, filtering, current sensing, instrumentation, and actuator control.
Key characteristics include a 33 MHz bandwidth and 10 V/µs slew rate, allowing the OPA228UA to support closed-loop gains of 5 or greater. Its precision-oriented architecture also makes it useful where DC offset, bias behavior, noise, and common-mode performance influence measurement accuracy. The device is available in the 8-SOIC package identified as OPA228UA by Texas Instruments.
The OPA228 belongs to a family of precision, low-noise operational amplifiers designed for both AC and DC applications. Unlike unity-gain-stable members of the related family, the OPA228 is optimized for gain settings of 5 or higher, helping preserve useful bandwidth in instrumentation chains. The wide bandwidth and high slew rate support faster settling in communications, test equipment, and sensor-interface circuits.
Typical applications include low-level sensor amplification, precision current measurement, active filters, data-conversion front ends, laboratory instrumentation, and industrial control loops. The device can be paired with external resistors for gain-setting or filtering and with external circuitry for offset and bias-current compensation when the application requires the highest precision.
Designers should check the closed-loop gain, output-voltage swing, common-mode range, supply voltage, capacitive-load stability, and noise-gain requirements before finalizing the circuit. Input and output routing should minimize parasitic capacitance and sensitive-input leakage, while power-supply bypassing should be placed close to the device. Stable operation near the gain limit requires reviewing the manufacturer’s stability and frequency-response guidance.
Bộ thay thế dễ dàng lắp đặt cho OPA228UA — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
OPA228UB
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
OPA228UC
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
OP37UA
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
OP37UB
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
OP37UC
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
OPA228UA Tỷ lệ tối đa & tính chất điện
| Product Type | High-precision operational amplifier |
| Amplifier Count | 1 circuit |
| Gain-Bandwidth Product | 33 MHz |
| Slew Rate | 10 V/µs |
| Minimum Recommended Closed-Loop Gain | 5 |
| Noise Performance | Low noise |
| DC Performance | High precision |
| AC Performance | Wide bandwidth |
| Hộp | 8-SOIC |
| Package Width | 3.90 mm |
| Kiểu lắp đặt | Surface mount |
| Số lượng chân | 8 pins |
Cấu hình chân OPA228UA
| Chân 1 | OFFSET NULL — Offset-voltage null adjustment terminal |
| Chân 2 | INVERTING INPUT — Inverting input terminal |
| Chân 3 | NON-INVERTING INPUT — Non-inverting input terminal |
| Chân 4 | V- — Negative supply terminal |
| Chân 5 | OFFSET NULL — Offset-voltage null adjustment terminal |
| Chân 6 | OUTPUT — Amplifier output terminal |
| Chân 7 | V+ — Positive supply terminal |
| Chân 8 | NC — Not connected |
Ứng dụng tiêu biểu
OPA228UA phù hợp cho 6 Áp dụngs: Precision Sensor Signal Conditioning, Data-Conversion Front End, Industrial Current Measurement, Active Analog Filters, Test and Measurement Equipment, Communications Receive Chain.
Precision Sensor Signal Conditioning
The OPA228UA fits low-level sensor front ends that require accurate DC amplification without sacrificing usable bandwidth. Its 33 MHz gain-bandwidth product and 10 V/µs slew rate support closed-loop gains of 5 or greater, while the family’s precision DC characteristics help reduce offset-related measurement error. The amplifier can condition strain-gauge, pressure, temperature, and bridge outputs before conversion or digitization. Because the device is optimized for gain above unity, the engineer should calculate the complete noise gain, confirm that the sensor source impedance remains compatible, and verify common-mode and output-swing limits. Placement close to the sensor reduces parasitic pickup and allows the low-noise signal path to remain compact.
Được đề xuất
Data-Conversion Front End
The OPA228UA can provide the gain and drive immediately preceding an analog-to-digital converter when the converter requires a low-impedance input. A 33 MHz gain-bandwidth product and a 10 V/µs slew rate allow the amplifier to preserve the speed of the signal chain, while high-precision DC behavior helps reduce gain and offset error before conversion. This is especially useful for medium- to high-speed industrial acquisition systems. The amplifier should be configured for the required signal gain and noise gain, and the output must remain within the converter’s input range. Board-level evaluation should also account for settling time, converter acquisition time, clock coupling, and the need for suitable termination or filtering between the amplifier and ADC.
Được đề xuất
Industrial Current Measurement
OPA228UA is appropriate for precision current-measurement amplifiers built around a low-value shunt resistor. The device’s low-noise, high-precision positioning supports accurate amplification of small shunt voltages, while its 10 V/µs slew rate helps reproduce rapidly changing current waveforms. It can be used in power monitoring, motor-control feedback, laboratory instrumentation, and industrial process controls. The gain resistor network should be checked for source impedance, resistor tolerance, and thermal-coefficient effects because these can dominate the final accuracy. The amplifier’s common-mode range must include the shunt voltage, and the design must avoid driving the input stage beyond its permitted operating region. Kelvin connections and guarded PCB routing improve practical measurement performance.
Được đề xuất
Active Analog Filters
The OPA228UA can serve as the gain element in active low-pass, band-pass, and notch-filter circuits where both precision and bandwidth matter. Its 33 MHz gain-bandwidth product supports higher-frequency filter sections than a purely precision, narrow-band amplifier, while the 10 V/µs slew rate improves large-signal behavior. This makes it useful in sensor-filtering, communications receive chains, audio measurement, and laboratory signal conditioning. Component selection must account for the closed-loop gain and noise gain rather than signal gain alone. The practical limit on high-Q or high-order filters often comes from resistor and capacitor tolerances, parasitic capacitance, and the amplifier’s output-current capability. Prototype the filter and verify gain, phase, and stability across the intended frequency and output-amplitude range.
Được đề xuất
Test and Measurement Equipment
OPA228UA suits precision laboratory and production-test instruments that combine low-level DC measurements with modest AC bandwidth requirements. Its high-precision DC characteristics support accurate buffer and gain stages, while the 33 MHz bandwidth and 10 V/µs slew rate allow the amplifier to handle faster test signals than a conventional precision op amp optimized mainly for low frequency. Potential uses include source monitoring, programmable supplies, automated fixture interfaces, and general-purpose measurement front ends. The circuit should include adequate input and output range checks and should avoid excessive capacitive loading at the output. For sensitive instruments, guard shields and clean grounding can reduce leakage and ground-potential errors. The manufacturer’s bias-current compensation and offset-adjustment guidance should be followed where maximum DC accuracy is required.
Được đề xuất
Communications Receive Chain
OPA228UA can amplify small signals in communications and networking equipment when the receiver requires precise DC behavior and higher bandwidth than a conventional slow precision amplifier. Its 33 MHz gain-bandwidth product and 10 V/µs slew rate support closed-loop gains of 5 or greater, making it appropriate for intermediate-frequency and baseband conditioning stages. The device can help maintain signal amplitude and phase performance when the required gain is moderate and the operating frequency is well below the amplifier’s bandwidth. RF-adjacent circuits still require careful impedance matching, filtering, and shielding. Validate the complete gain, isolation, and distortion requirements rather than evaluating only the small-signal bandwidth. In a production design, compare the receive-chain gain, noise figure, and linearity with the complete signal path.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho OPA228UA — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | OPA228UB | OPA228UC | OP37UA | OP37UB | OP37UC |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices | Analog Devices | Analog Devices |
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Amplifier Count | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
| Application Class | General-purpose precision amplifier | General-purpose precision amplifier | General-purpose precision amplifier | Precision operational amplifier | Precision operational amplifier | Precision operational amplifier |
Bảo phân biệt quan trọng
- Higher nominal speed than the industry-standard replacement family (vsOP37UA)
- Designed for precision and bandwidth in the same amplifier (vsOP37UB)
- Same manufacturer family with temperature-grade ordering flexibility (vsOPA228UB)
Ghi chú thiết kế
The OPA228 is optimized for closed-loop gains of 5 or greater, so unity-gain operation should not be treated as interchangeable with a unity-gain-stable amplifier. Calculate both the signal gain and the noise gain, including feedback-network impedance and source impedance, before finalizing the circuit. In instrumentation designs, the feedback network must also be included in the noise analysis. If the required operating gain is below 5, select an amplifier explicitly designed for stable unity-gain operation rather than adding unnecessary compensation or reducing the feedback ratio.
Keep the non-inverting and inverting input routes short, isolate them from switching nodes, and avoid routing sensitive inputs beside high-impedance or high-voltage traces. Place supply-bypass capacitors close to pins 4 and 7 with a short return path to the device ground or supply-reference node. If offset trimming is used, connect the offset-null terminals through a clean potentiometer arrangement and keep the associated copper away from fast edges. Sensitive bridge or shunt measurements benefit from guarded layouts and a clean analog ground reference.
Treat the OPA228 as a high-speed precision amplifier even when the signal of interest is low frequency. Its 33 MHz gain-bandwidth product and 10 V/µs slew rate can excite parasitic capacitance through long PCB traces or connector leads. Terminate cables appropriately, add filtering only after accounting for the closed-loop gain, and validate phase margin using the complete source, feedback, and load network. For ADC front ends, check amplifier settling against the converter’s acquisition window and use the manufacturer’s output-capacitance guidance when driving long or capacitive loads.
Verify supply voltage, input common-mode range, output swing, and output-current capability under the actual load before enabling the amplifier. Estimated: if a 5 V supply drives a 3 V output at 10 mA, the amplifier’s quiescent and load-related dissipation must remain within the package thermal limits after adding supply-decoupling-network losses; the exact dissipation and junction temperature require the circuit’s actual supply and load values. Use short, low-inductance supply connections and decouple each supply pin according to the manufacturer guidance.
Thông tin tuân thủ
No explicit RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statement appears in the accessible manufacturer and distributor information.