TLE62512GXUMA3 - 1 MBd HS-CAN Transceiver, ISO 11898-5 | Infineon
MPN: TLE62512GXUMA3 ✓ Hoạt độngTLE62512GXUMA3 Tóm tắt
A CAN transceiver, also called a CAN physical-layer interface or CAN PHY, is the bridge between a microcontroller's CAN controller and a differential CAN bus. It converts logic-level TXD and RXD signals into the differential CANH and CANL bus pair and converts received bus levels back to digital logic. The Infineon TLE6251-2G family belongs to the high-speed CAN (HS-CAN) class of interface ICs, sitting at the physical layer of an automotive communication network.
Key features of the TLE62512GXUMA3 include very low power consumption in Sleep mode, bus wake-up capability, a local wake-up inhibit output to control external circuitry, and split termination to stabilize the recessive bus level. A separate failure diagnosis output gives the host microcontroller a hardware health check on the physical layer, and the device is optimized for low electromagnetic interference, which reduces the need for external shielding and filtering in the ECU.
Technically, the TLE6251-2G is positioned as the successor of the TLE6251G, with excellent passive behaviour in power down. This makes the part well suited to mixed power-supply HS-CAN networks where some nodes are unpowered at times while the bus remains active. The TLE6251G and the TLE6251-2G are pin compatible and function compatible, so the two devices can be used interchangeably on the same PCB land pattern. The separate VIO pin allows the transceiver to be interfaced to microcontrollers supplied from 3.3 V or 5 V without level-shifting logic.
Typical applications include electronic control units in body and powertrain domains, CAN gateways, climate control and comfort modules, sensor nodes in distributed vehicle networks, industrial CANopen and DeviceNet equipment, and diagnostic interfaces in workshop tooling.
When laying out the board, place the 100 nF and 1 uF supply decoupling capacitors directly at the VCC and VIO pins, and keep the CANH and CANL traces short, impedance-matched, and free of stubs. Use the split termination feature instead of fitting a single 60 ohm resistor so that split values can be tuned for EMC margin.
This page consolidates device specifications, drop-in alternatives from the same Infineon family, a parameter comparison, and practical layout guidance into a single engineering reference.
Bộ thay thế dễ dàng lắp đặt cho TLE62512GXUMA3 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với TLE62512GXUMA3 (cùng hình factor và footprint) — khác nhau ở Package, Product Type, Automotive Qualification, EMI Performance, Failure Detection.
TLE62512GXUMA1
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →TLE62512GXUMA2
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
TLE6251GXUMA2
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
TLE6251DXUMA2
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →TLE6251DXUMA1
✅ Drop-In ⚠️ Thông số chưa được xác minhLiên hệ để biết giá
Xem tài liệu →TLE62512GXUMA3 Thông số kỹ thuật
| Product Type | High-speed CAN transceiver (HS-CAN interface IC) |
| Data Transmission Rate | 1 MBd (1 Mbit/s) |
| Standard Compliance | ISO 11898-5 |
| Supply Voltage Range (VCC) | 4.75 V to 5.25 V |
| CAN Bus Voltage Range | 5.5 V to 18 V |
| Hộp | PG-DSO-14 (14-pin, 3.90 mm width) |
| Số chân | 14 pins |
| Kiểu lắp đặt | Surface Mount |
| Automotive Qualification | AEC-Q100 qualified |
| Trạng thái RoHS | RoHS compliant |
| Power-Down Behaviour | Passive behaviour in power down |
| Wake-Up Features | Bus wake-up and local wake-up inhibit output |
| Termination | Split termination to stabilize the recessive level |
| Diagnostics | Separate output for failure diagnosis |
| EMI Performance | Optimized for low electromagnetic interference |
| Sleep / Standby Control | Sleep and standby operating modes |
| Shipping Format | Tape & reel |
Hướng dẫn cấu hình chân TLE62512GXUMA3 pg-dso-14 (14-pin, 3.90 mm width)
Cấu hình chân cho TLE62512GXUMA3 (pg-dso-14 (14-pin, 3.90 mm width) gói). Số thứ tự chân, chức năng và sơ đồ kết nối được xác định trong tài liệu thông số kỹ thuật của nhà sản xuất. Tham khảo nó để biết footprint và hướng dẫn hàn chính xác.
Không có dữ liệu chân cụ thể sẵn có cho TLE62512GXUMA3.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
TLE62512GXUMA3 phù hợp cho 6 Áp dụngs: Automotive Body Control Unit CAN Interface, Powertrain and Chassis Network Node, CAN Gateway and Communication Hub, Industrial CANopen and DeviceNet Equipment, Vehicle Sensor and Actuator Node, Automotive Diagnostic and Workshop Interface.
Automotive Body Control Unit CAN Interface
The TLE62512GXUMA3 gives a body control unit a 1 MBd ISO 11898-5 physical layer for door, lighting, and climate subsystems sharing one HS-CAN backbone. Its passive behaviour in power down matters in mixed power-supply vehicles, where a gateway node may be asleep while others transmit, so an unpowered transceiver must not disturb the recessive bus level. The split termination option and the separate failure diagnosis output both help the ECU qualify EMC margin and confirm bus health at self-test time, while the 14-pin PG-DSO-14 package keeps the footprint compact for densely populated body modules.
Được đề xuất
Powertrain and Chassis Network Node
In a powertrain or chassis node, the TLE62512GXUMA3 links a controller to a noisy vehicle bus where radiated and conducted emissions are tightly constrained. The device is optimized for low electromagnetic interference, so the ECU can pass CISPR 25 style emissions testing with less external filtering, and the 1 MBd HS-CAN rate matches the throughput expected of powertrain messaging. AEC-Q100 qualification supports use in this domain, and the separate VIO input lets the transceiver interface with a lower-voltage domain logic without adding level shifters.
Được đề xuất
CAN Gateway and Communication Hub
A gateway that bridges CAN segments benefits from the TLE62512GXUMA3 because bus wake-up lets a sleeping gateway module be revived by traffic on any connected segment, while the local wake-up inhibit output controls the external circuitry that holds the gateway in reset or removes it from the bus. Passive behaviour in power down ensures that a gateway segment can be powered off during shutdown without corrupting the recessive level of the remaining active network. The 1 MBd ISO 11898-5 compliance makes it interoperable with legacy HS-CAN devices in mixed-generation vehicle fleets.
Được đề xuất
Industrial CANopen and DeviceNet Equipment
For industrial CANopen masters, remote I/O modules, and DeviceNet sensors, the TLE62512GXUMA3 provides a 1 MBd physical layer that meets ISO 11898-5 timing so it interoperates with a wide installed base of controllers. The separate VIO input is useful in factory equipment where the logic rail is 3.3 V while the transceiver core stays at 5 V, removing a discrete level-shifter stage from the board. Bus wake-up supports remote station reconnection, and the failure diagnosis output gives the PLC a hardware indication of bus health for maintenance logging.
Được đề xuất
Vehicle Sensor and Actuator Node
Distributed sensor nodes and actuator drivers in a vehicle often sit at the end of a CAN branch where space, cost, and standby current dominate. The TLE62512GXUMA3 combines a 14-pin PG-DSO-14 footprint with very low power consumption in Sleep mode, so a node that only wakes on bus traffic does not drain the vehicle battery. Local wake-up inhibit gives the node a way to mask its own wake path, avoiding a wake storm when several parked modules share a bus, and the small package leaves PCB area for the sensing and drive circuitry.
Được đề xuất
Automotive Diagnostic and Workshop Interface
Diagnostic tools that tap into an existing vehicle CAN network rely on a transceiver that behaves predictably and does not disturb the bus during connection or removal. The TLE62512GXUMA3 offers bus wake-up for triggering a diagnostic session on a sleeping vehicle network and a failure diagnosis output that indicates physical-layer faults to the tool firmware. Its low EMI behaviour reduces reflections on the stub connection used by workshop equipment, and the ISO 11898-5 compliance guarantees correct arbitration with the many legacy ECUs found across mixed vehicle generations.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho TLE62512GXUMA3 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | TLE62512GXUMA1 | TLE62512GXUMA2 | TLE6251GXUMA2 | TLE6251DXUMA2 | TLE6251DXUMA1 |
|---|---|---|---|---|---|---|
| Package | PG-DSO-14 | PG-DSO-14 - same | PG-DSO-14 - same | PG-DSO-14 - same | PG-DSO-14 - same | PG-DSO-14 - same |
| Brand | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies |
| Maximum Data Rate | 1 MBd | 1 MBd | 1 MBd | 1 MBd | 1 MBd | 1 MBd |
| Standard Compliance | ISO 11898-5 | ISO 11898-5 | ISO 11898-5 | ISO 11898-5 | ISO 11898-5 | ISO 11898-5 |
Bảo phân biệt quan trọng
- Improved passive behaviour in power down for mixed power-supply HS-CAN networks (vsTLE6251GXUMA2)
- Higher product grade within the same pin-compatible footprint (vsTLE62512GXUMA1)
- Local wake-up inhibit plus dedicated failure diagnosis output (vsTLE6251DXUMA2)
- 14-pin PG-DSO-14 with separate VIO logic input (vsTJA1057GTKZ)
Ghi chú thiết kế
Place the VCC and VIO decoupling capacitors immediately at the device pins rather than at the connector or regulator. Use a 100 nF ceramic capacitor in parallel with a 1 uF capacitor on each supply pin, with a short ground return and a solid ground plane directly under the transceiver. Keep the CANH and CANL traces as a tightly coupled differential pair with continuous reference plane underneath, avoid any stubs, and route the pair away from switching nodes and antenna feeds.
Use the split termination feature rather than a single 60 ohm resistor across CANH and CANL. The split network lets the recessive common-mode voltage be tuned, which reduces radiated emissions and improves immunity in the vehicle environment. Mount the termination network at the physical end of the bus only, not at every node, and keep the connection from the transceiver to the bus connector as short as possible to limit stub reflections that cause data errors at 1 MBd.
The VIO input may be tied to the microcontroller supply rail so that TXD and RXD logic levels match the MCU, while VCC stays at 5 V for the transceiver core. Do not leave VIO floating. In sleep designs, drive the sleep or standby control pin from the MCU so the node can be woken either by bus traffic or locally, and use the local wake-up inhibit output to prevent repeated wake attempts from masked nodes.
Do not substitute an 8-pin HS-CAN transceiver such as the TJA1057 family for the TLE62512GXUMA3. The competitor devices use a smaller SOIC-8 footprint with a different pin arrangement and a different VIO arrangement, so they are not drop-in and require a PCB respin. When upgrading within Infineon, verify the wake-up inhibit and failure diagnosis pin functions in the datasheet pin table before release, because the earlier TLE6251G generation behaves differently in power down.
Thông tin tuân thủ
RoHS compliance and automotive AEC-Q100 qualification are stated for the TLE6251-2G family and the TLE62512GXUMA3 listing. REACH, lead-free status, halogen-free status, and conflict-minerals declarations are not stated in the product documentation and are listed as unknown.